Drawings.pdf
PDF 7 MB Posted
- Attached to
- Renovate 823 RHS Wash Rack Bldg 91144
- Solicitation number
- FA4417-15-R-0020
About this file
Drawing FTEV 09-1033
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions_ _Answers.pdf | ||
| FA4417-15-R-0020_Amendment_2.pdf | ||
| FA4417-15-R-0020_Amendment_1.pdf | ||
| Wage_Rates.pdf | ||
| FA4417-15-R-0020.pdf | ||
| Performance_Questionnaire.pdf | ||
| Specifications.pdf | ||
| Financial_reference.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHELTER
TEE
GOLF
S
S
WT-12
MT-12 WT-14
MT-14
MT-15
WT-15
WT-13
MT-13
WT-11
COURSE
SHELTER
TEE
SS
S
S
S
G-12
S
G-13
G-14S
G-11
S
G-3
SHELTER
TEE
G-10 S
S
SS
S
MT-11
S
MT-8
WT-8
MT-6
S
S
S s
MT-10
MT-1
WT-1
MT-6
WT-3
MT-2
WT-2MT-9
WT-9
MT-18
WT-18
WT-10
S
PRACTICE TEE
FAIRWAY
PRACTICE
S
S
G-8
G-5
M-3
S
S G-1
G-2
S
S
S
S
GREEN
PRACTICE
G-9 S
S S
S
S
G-18
SS
S
S
S
MT-8
WT-8 S
S
S S
S
S
S
S
S
WT-6
M-4
MT-16 WT-16
S
G-15
S
S
S
WT-17 MT-17
G-17
G-16
SS
S
B O U N D A R Y
B O U N D A R Y
BOUNDARY
R E S E R V A
TI
O N
RESERVATIONRESERVATION
R E S E R V A T I O N
R E S E R V A T I O N
HURLBURT
LAKE
STATIONSTATION
SUB-SUB-
TANK
TA
NK
OIL/WATER SEPARATOR
TANK
WATER
JP-4
TANKS
OI
L/
WA
TE
R
TA
NK
S
SE
PA
RA
TO
R
OIL/WATER
SEPARATORS
TANK
P.O.L.
PUMP HOUSE
TA
NK
TANKS
TANK
WATER
JP-4
CV-22 ADDI TION
In-process
HO
US
E
PU
MP
TA
NKWA
TE
R
PU
MP
TA
NKWA
TE
R
H
H
R O AD W
AY
R O AD W
AY
R O AD W
AY
R O AD W
AY
B
A-
A-
B
90734
PCC
ANTENNA
LOCALIZER
HO
US
E
PU
MP
TA
NKWA
TE
R
PU
MP
TA
NKWA
TE
R
TO
PENSACOLA
40 MILES
GULF OF MEXICO
SANTA ROSA ISLAND
ESTHER
MARY
FORT WALTON
BEACH
HURLBURT
FIELD
EGLIN AIR FORCE BASE
REGION
MAIN GATE BASE CIVIL
ENGINEERS
PASS
& I.D.
FIRE
DEPTCONTRACTING
SECURITY
POLICE
MLK JR BLVD
CONTRACTOR'S
ENTRANCE
HAUL ROUTE
91144
91145
91132
91124
91120
91101
FREEDOM WAY
INDEPENDENCE ROAD
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
PR
OJ
EC
T
MA
NA
GE
R
US
IN
G
AG
EN
CY
BI
O
- E
NV
IR
ON
ME
NT
AL
CE
O
CO
MM
UN
IC
AT
IO
N
EN
VI
RO
NM
EN
TA
L
FI
RE
C
HE
IF
MA
IN
TE
NA
NC
E
EN
GI
NE
ER
SA
FE
TY
SE
CU
RI
TY
P
OL
IC
E
O
SS
/C C
C O
VE
R
S H
EE
T
G1
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
REGIONAL MAPVICINITY MAP
SCALE: 1" = 1000'
LOCATION MAP
SCALE: 1" = 200'
SCALE: NTS
PROJECT LOCATION
PROJECT LOCATION
INDEX OF DRAWINGS
SHEET
NO. SHEET NAME
SUBMITTAL
DATE
GENERAL
G1 COVER SHEET
G2 PROJECT INFORMATION
CIVIL
C1.0 EXISTING SITE SURVEY
C1.1 EXISTING SITE, DEMOLITION & EROSION CONTROL PLAN
C2.0 SITE LAYOUT & DIMENSION PLAN
C2.1 DETAILS
C3.0 GRADING & DRAINAGE PLAN
STRUCTURAL
S0 GENERAL NOTES & WIND INFORMATION
S1 FOUNDATION PLAN
S2 ROOF FRAMING PLAN
S3 SECTIONS & DETAILS
ARCHITECTURAL
A1 NEW WORK FLOOR PLAN
A2 MEZZANINE PLAN
A3 REFLECTED CEILING PLAN
A4 ELEVATIONS
A5 ELEVATIONS
A6 SECTIONS
A7 FINISH SCHEDULE
PLUMBING
P0 PLUMBING LEGEND, NOTES, & ABBREVIATIONS
P1 PLUMBING DEMO PLAN
P2 PLUMBING NEW WORK PLAN
P3 MEZZANINE LEVEL PLUMBING NEW WORK PLAN
P4 PLUMBING DETAILS
ELECTRICAL
E0 ELECTRICAL LEGEND & NOTES
E1 ELECTRICAL DEMO PLAN
E2 ELECTRICAL LIGHTING PLAN
E3 ELECTRICAL POWER PLAN
FTEV 09-1033
RENOVATE 823 RHS WASH RACK BLDG 91144
HURLBURT FIELD, FL
S Y M B O L S L E G E N D
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION
ENLARGED CALLOUT
KEYNOTE; SEE GENERAL NOTE 8
ROOM IDENTIFICATION; SEE ROOM
FINISH SCHEDULE
DOOR IDENTIFICATION; SEE DOOR
SCHEDULE
WINDOW OR LOUVER IDENTIFICATION;
SEE WINDOW SCHEDULE
PARTITION TYPE; SEE WALL TYPE
SCHEDULE
ELEVATION
NORTH ARROW
REVISION SYMBOL AND BUBBLE
TITLE KEY
Name
1t
4A
1i
A101
SIM
A101
SIM___
1 View Name 1/8" = 1'-0"A102 A101
Name Elevation
0'4'8' 8' 16'
A101
A101
DETAIL NUMBER
GRAPHIC SCALE BAR
SHEET DRAWN ON
SHEET OF FIRST REFERENCE
DETAIL NUMBER
SHEET DRAWN ON
DETAIL NUMBER
SHEET DRAWN ON
DETAIL NUMBER
SHEET DRAWN ON
DETAIL NUMBER
SHEET DRAWN ON
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ACOUS ACOUSTICAL
ADJ ADJUSTABLE
AL ALUMINUM
AB ANCHOR BOLT
APPROX APPROXIMATELY
BD BOARD
BLDG BUILDING
BLK BLOCK
BM BEAM
BOD BOTTOM OF DECK
CB CATCH BASIN
CDS CONCEALED DOWNSPOUT
CG CORNER GUARD
CJ CONTROL JOINT
CMU CONCRETE MASONRY UNIT
CEM CEMENT
CLG CEILING
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
DBL DOUBLE
DTL DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DS DOWNSPOUT
DWGS DRAWINGS
EA EACH
EF EXHAUST FAN
EL ELEVATION
ELECT ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
A B B R E V I A T I O N S
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FND FOUNDATION
FFE FINISH FLOOR ELEVATION
FIN FINISH
FLR FLOOR
FLUOR FLUORESCENT
FT FOOT
FTG FOOTING
FP FILLER PANEL
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GEN GENERAL
GYP GYPSUM
GYP BD GYPSUM BOARD
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
INSUL INSULATION
INT INTERIOR
JT JOINT
LAM LAMINATE
LAV LAVATORY
LT WT LIGHT WEIGHT
MO MASONRY OPENING
MANUF MANUFACTURER
MAX MAXIMUM
MECH MECHANICAL
MTL METAL
MIN MINIMUM
OC ON CENTER
OH OPPOSITE HAND
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED,
OWNER INSTALLED
OPNG OPENING
OVH OVERHANG
PT PLATE
PLYWD PLYWOOD
R RADIUS
RO ROUGH OPENING
REINF REINFORCED
REQD REQUIRED
RET RETAINING
RM ROOM
SC SCUPPER
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SQ FT SQUARE FOOT
ST STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
T&G TONGUE AND GROOVE
TO TOP OF
TOD TOP OF DECK
TOG TOP OF GRADE
TOS TOP OF SLAB
TOW TOP OF WALL
TEL TELEPHONE
TYP TYPICAL
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
WWF WELDED WIRE FABRIC
WD WOOD
XPT EPOXY PAINT
1. DO NOT SCALE DRAWINGS; REFERENCE DIMENSIONS ON
DRAWINGS AND FIELD VERIFY ALL MEASUREMENTS.
2. UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FACE OF
STUD, COLUMN CENTERLINE, OR FACE OF EXISTING FINISH.
3. UNLESS NOTED OTHERWISE, ALL NEW WORK WHICH EXTENDS
OR INFILLS EXISTING WORK SHALL ALIGN WITH AND MATCH
EXISTING CONDITIONS.
4. ALL DISCREPANCIES OR CONFLICTING INFORMATION
BETWEEN EXISTING CONDITIONS, CONSTRUCTION DRAWINGS,
AND SPECIFICATIONS ARE TO BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT FOR RESOLUTION BEFORE
COMMITTING TO WORK OUTLINED.
5. KEYNOTE NUMBERING SEQUENCE FOUND ON ONE SHEET IS
INDEPENDANT FROM OTHER SHEETS IN THE SET.
G E N E R A L N O T E S
ARCHITECT
CALDWELL ASSOCIATES ARCHITECTS, INC
H. MILLER CALDWELL, JR., RA
116 NORTH TARRAGONA STREET
PENSACOLA, FLORIDA 32501
(850) 439-6576 phone
(850) 438-6537 fax
P R O J E C T T E A M
MECHANICAL/ELECTRICAL/PLUMBING
SCHMIDT CONSULTING GROUP
TODD NICHOLSON, PE
40 SOUTH PALAFOX
SUITE 3000
PENSACOLA, FLORIDA 32502
(850) 438-0050 phone
CIVIL
REBOL-BATTLE INC.
PAUL BATTLE, PE
214 EAST CHURCH STREET
PENSACOLA, FLORIDA 32502
(850) 438-0400 phone
STRUCTURAL
JOE DEREUIL ASSOCIATES, LLC
JOE DEREUIL, PE
301 WEST CERVANTES STREET
PENSACOLA, FLORIDA 32502
(850) 429-1951 phone
EARTH/COMPACT FILL
CAST-IN-PLACE/PRECAST
CONCRETE
MORTAR/GROUT (SECTION)
GYPSUM BOARD (ELEVATION)
FINISH GRADE WOOD
NOMINAL DRESSED BLOCKING
SHIM/FILLER BLOCKING WITH
BACKER ROD AND SEALANT
CMU (IN SECTION)
RIGID INSULATION
BATT INSULATION
PLYWOOD
GYPSUM BOARD
M A T E R I A L L E G E N D
APPLICABLE CODES
THE FOLLOWING CODES AND REVISIONS ARE APPLICABLE TO THIS
PROJECT:
INTERNATIONAL BUILDING CODE (IBC) 2012
INTERNATIONAL BUILDING CODE; EXISTING BUILDING (IBC-EB) 2012
INTERNATIONAL BUILDING CODE; PLUMBING (IBC-P) 2012
INTERNATIONAL BUILDING CODE; MECHANICAL (IBC-M) 2012
NATIONAL FIRE PROTECTION ASSOCIATION;
FIRE PROTECTION CODE (NFPA 101) 2012
S C O P E O F W O R K
BASE BID:
BASE BID SCOPE OF WORK INCLUDES PRESSURE
WASHING/BLASTING, MINOR REPAIR AND FINISH PAINTING OF
EXTERIOR AND INTERIOR WALLS; PRESSURE WASHING/BLASTING
AND FINISH PAINTING OF MEZZANINE AND ROOF DECK
COMPONENTS, ELEVATED PLATFORM AND RELATED
ACCESSORIES; DOOR PAINTING AND MINOR HARDWARE
REPLACEMENT; LOUVER REPLACMENT; TRENCH PIT AND
EQUIPMENT REMOVAL; PLUMBING EQUIPMENT REPLACEMENT
INCLUDING TRENCH DRAINS, OIL-WATER SEPARATOR, PRESSURE
WASHING SYSTEM; ELECTRICAL SYSTEM COMPONENT
REPLACEMENT INCLUDING PANELBOARDS, LIGHT FIXTURES AND
BRANCH WIRING; FIRE ALARM DEVICE REPLACEMENT.
REPLACEMENT OF DAMAGED CONCRETE PAVEMENTS AND SOD IN
ADJACENT UNPAVED AREAS IS ALSO INCLUDED IN BASE BID WORK.
FURNISH COMPLETE AS DEFINED IN THE DRAWINGS AND
SPECIFICATIONS.
BID OPTION #1:
BID OPTION SCOPE OF WORK INCLUDES A NEW STEEL ROOF
STRUCTURE CONSTRUCTED OVER THE EXISTING OPEN WASH BAY
COMPRISED OF FINISH PAINTED, REINFORCED CONCRETE PIERS;
FINISH PAINTED, STRUCTURAL STEEL FRAMING SYSTEM;
PREFINISHED, CORRUGATED ROOF DECK; PREFINISHED METAL
FASCIA PANEL CONSTRUCTION; PREFINISHED METAL GUTTERS,
DOWNSPOUTS AND FLASHINGS; NEW OVERHEAD LIGHTING.
FURNISH COMPLETE STRUCTURE AS DEFINED IN THE DRAWINGS
AND SPECIFICATIONS.
E N V I R O N M E N T A L C O N C E R N S
LEAD-BASED PAINT REMOVAL
LEAD-BASED PAINT HAS BEEN IDENTIFIED IN THE PAINT COATINGS
ON APPROXIMATELY (10) DIAGONAL ROOF ANGLE SUPPORTS,
MEZZANINE LADDER, AND YELLOW PAINT STRIPING ON THE
CONCRETE PAVEMENT IN THE COVERED WASH BAY. REFER TO
UNIVERSAL ENGINEERING SCIENCES LEAD-BASED SURVEY
REPORT NUMBER 1172395 DATED OCTOBER 30, 2014, PROVIDED
AS APPENDIX A OF THE PROJECT SPECIFICATIONS.
REMOVAL AND DISPOSAL OF ALL LEAD-BASED PAINT SHALL BE
PERFORMED IN ACCORDANCE WITH PROJECT SPECIFICATION
SECTION 01 56 00, PART 3; SECTION 3.10.C: LEAD BASED PAINT.
THIS WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL
APPLICABLE REQUIREMENTS OF THIS SPECIFICATION AND U.S.
ENVIRONMENTAL PROTECTION AGENCY, THE OCCUPATIONAL
SAFETY AND HEALTH ADMINISTRATION, THE NATIONAL INSTITUTE
FOR OCCUPATIONAL SAFETY AND HEALTH, AND OTHER FEDERAL,
STATE, COUNTY AND LOCAL AGENCIES.
OIL / WATER SEPARATOR EXCAVATION AND REMOVAL
A TOTAL OF FOUR SOIL SAMPLES WERE COLLECTED FROM THE
AREA OF THE EXISTING OIL WATER SEPARATOR. ANALYSIS OF
THESE SAMPLES FOR VOLATILE ORGANIC COMPOUNDS,
POLYNUCLEAR AROMATIC HYDROCARBONS, AND THE EIGHT
RESOURCE CONSERVATION AND RECOVERY ACT METALS DID NOT
IDENTIFY PETROLEUM CONSTITUENTS OR METALS AT
CONCENTRATIONS THAT EXCEEDED THEIR RESPECTIVE SOIL
CLEANUP TARGET LEVELS (SCTLS), AS ESTABLISHED BY THE
STATE OF FLORIDA. REFER TO UNIVERSAL ENGINEERING
SCIENCES SOIL SAMPLE ANALYTICAL REPORT NUMBER
1740.1400047.0000 DATED NOVEMBER 20, 2014, PROVIDED AS
APPENDIX B OF THE PROJECT SPECIFICATIONS.
PRIOR TO REMOVAL OF THE OIL/WATER SEPARATOR, ALL LIQUIDS
SHOULD BE REMOVED BY VACUUM TRUCK AND PROPERLY
DISPOSED. DURING THE EXCAVATION OF SOIL IN THE IMMEDIATE
AREA OF THE OIL/WATER SEPARATOR, ANY SOILS THAT EXHIBIT A
PETROLEUM ODOR OR VISUAL STAINING SHOULD BE
SEGREGATED FROM NON-IMPACTED SOILS IN AN AREA THAT WILL
NOT BE IMPACTED BY THE CONSTRUCTION ACTIVITIES, AND THAT
IS APPROVED BY THE HURLBURT FIELD ENVIRONMENTAL FLIGHT.
THESE SOILS SHALL BE PLACED ON PLASTIC SHEETING AND
COVERED WITH PLASTIC SHEETING. THE CONTRACTOR MUST
THEN CONTACT UNIVERSAL ENGINEERING SCIENCES (UES) FOR
THE COLLECTION OF WASTE CHARACTERIZATION SAMPLES FOR
ANALYSIS. THE REQUIRED ANALYSIS WILL BE DICTATED BY THE
SELECTED DISPOSAL FACILITY. ONCE THE WASTE
CHARACTERIZATION ANALYTICAL RESULTS ARE RECEIVED FROM
THE LABORATORY, UES WILL ARRANGE FOR THE TRANSPORT AND
DISPOSAL OF THE MATERIAL AT THE CONTRACTOR’S EXPENSE, IF
DETERMINED BY ANALYSIS TO BE REQUIRED.
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
G2
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
E X
I S
T I N
G
S
I T
E
S
U R
V E
Y
LEGEND
DESIGNED BY:
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P' D
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
GTP
PAB
X
I S
T I N
G
S
I T
E
D
E M
O L
I T
I O
N
E
R O
S I O
N
C
O N
T R
O L
P
L A
N
LEGEND
DESIGNED BY:
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P' D
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
GTP
PAB
SILT FENCE DETAIL
S I T
E
L
A Y
O U
T
D I M
E N
S I O
N
P
L A
N
DESIGNED BY:
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P' D
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
GTP
PAB
02 MAR 2015
LEGEND
BID OPTION 1
WITH COVERED WASH RACK
A A
B B
D
T A
I L
S
DESIGNED BY:
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P' D
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
GTP
PAB
02 MAR 2015
EXPANSION JOINT DETAIL
CONCRETE PAVEMENT SECTION
N.T.S.
A-A NEW REINFORCED CONCRETE PAVEMENT
SECTION
WITH MIFAB T2400
N.T.S.
B-B EXISTING SLAB REINFORCED CONCRETE PAVEMENT
SECTION
WITH MIFAB T2400
N.T.S.
T-2400 TRENCH DRAIN DETAIL
BUTT CONSTRUCTION JOINT DETAIL
DOWELED CONSTRUCTION JOINT
FOR CONCRETE PAVEMENT
CONCRETE SLAB DETAIL
CONTRACTION JOINT DETAIL
G R
A D
I N
G
D
R A
I N
A G
E
P
L A
N
DESIGNED BY:
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P' D
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
GTP
PAB
02 MAR 2015
LEGEND
BID OPTION 1
WITH COVERED WASH RACK
3.09 DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS APPROVED OR DIRECTED BY THE STRUCTURAL ENGINEER.
3.10 ALL REINFORCING STEEL PLACEMENTS SHALL BE REVIEWED BY A REGISTERED STRUCTURAL ENGINEER, OR BY A REPRESENTATIVE
RESPONSIBLE TO HIM. (RE: ACI 318 PAR. 1.3.1)
4.00 STRUCTURAL STEEL
4.01 STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC "SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS, ASD, LATEST EDITION.
4.02 SUBMIT SHOP DRAWINGS PREPARED IN ACCORDANCE WITH AISC MANUAL "DETAILING FOR STEEL CONSTRUCTION", LATEST EDITION. STEEL FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND
REVIEWED.
4.03 STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. STRUCTURAL STEEL SHAPES, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36 UNLESS NOTED OTHERWISE. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI, UNLESS NOTED OTHERWISE. STEEL PIPE SHALL CONFORM TO ASTM A501 OR ASTM A53, TYPE E OR S, GRADE B. ANCHOR BOLTS SHALL CONFORM TO ASTM
A36 UNLESS NOTED OTHERWISE.
4.04 BOLTS SHALL CONFORM TO ASTM A325, 3/4-INCH DIAMETER MINIMUM, UNLESS NOTED OTHERWISE. BOLTS IN BEARING CONNECTIONS SHALL BE DESIGNATED TYPE N, TENSIONED, SNUG-TIGHT AS DEFINED BY AISC. BOLTS IN MOMENT CONNECTIONS AND IN TRUSSES SHALL BE DESIGNATED SLIP- CRITICAL (SC). FULLY TENSION SLIP-CRITICAL CONNECTIONS WITH DIRECT TENSION INDICATOR WASHERS INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTION.
4.05 USE PRE-QUALIFIED WELDED JOINTS AS PER AISC, AND AWS D1.1 "STRUCTURAL WELDING CODE." USE ONLY CERTIFIED WELDERS; ALL ELECTRODES SHALL CONFORM TO AWS A5 GRADE E70XX. BARE ELECTRODE AND GRANULAR FLUX SHALL CONFORM TO AWS A5, F70 AWS FLUX
CLASSIFICATION. MINIMUM WELD SIZE TO BE 3/16" FILLET WELD, U.N.O.
4.06 CUTS, BOLTS, COPING, ETC. REQUIRED FOR WORK OR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP.
CUTS OR BURNING HOLES IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED.
4.07 SHOP CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS MAY BE WELDED OR BOLTED. FIELD CONNECTIONS NOT SPECIFICALLY
DETAILED ON THE DRAWINGS SHALL BE BOLTED, WHERE POSSIBLE.
4.08 FIELD SPLICES SHALL BE DESIGNED TO DEVELOP THE FULL CAPACITY OF MEMBER AT THE POINT OF SPLICE IN BENDING, SHEAR AND AXIAL
LOAD (COMPRESSION AND TENSION).
4.09 ALTERNATE CONNECTION DETAILS MAY BE USED IF SUCH DETAILS ARE SUBMITTED TO THE ENGINEER FOR REVIEW AND ACCEPTANCE IS GRANTED. HOWEVER, THE ENGINEER SHALL BE THE SOLE JUDGE OF ACCEPTABILITY AND THE CONTRACTOR'S BID SHALL ANTICIPATE THE USE OF THE SPECIFIC DETAILS SHOWN ON THE DRAWINGS. IN ANY EVENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN OF SUCH ALTERNATE
DETAILS, WHICH HE PROPOSES.
4.10 PROVIDE STIFFENER PLATES ON EACH SIDE OF WEB OF BEAM OR GIRDER AT POINTS OF CONCENTRATED LOADS. MINIMUM STIFFENER PLATE THICKNESS SHALL BE 1/2" OR FLANGE THICKNESS OF COLUMNS ABOVE OR BELOW, WHICHEVER IS THICKER.
4.11 FILLER BEAMS OR JOISTS SHOULD BE SPACED EQUALLY BETWEEN THE COLUMNS IF NOT SHOWN OTHERWISE ON THE DRAWINGS.
4.12 PROVIDE TEMPORARY BRACING OF STRUCTURAL FRAMING TO PROVIDE LATERAL SUPPORT UNTIL ALL PERMANENT BRACING MOMENT
CONNECTIONS AND FLOOR AND ROOF DECKS (DIAPHRAGMS) ARE COMPLETELY INSTALLED.
4.13 STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE MECHANICAL DRAWINGS AND DRAWINGS RELATED TO OTHER TRADES.
CONTRACTOR SHALL BE RESPONSIBLE TO CHECK AND COORDINATE DIMENSIONS, CLEARANCES, ETC. WITH THE WORK OF OTHER TRADES. THE STRUCTURAL STEEL CONTRACTOR SHALL PROVIDE FRAMING AROUND OPENINGS IN FLOOR AND ROOF SLAB AS INDICATED IN THE MECHANICAL
DRAWINGS.
4.14 THE STRUCTURAL STEEL CONTRACTOR SHALL PROVIDE WEB REINFORCEMENT AT OPENINGS IN STEEL BEAMS AND GIRDERS FOR MECHANICAL AND ELECTRICAL PENETRATIONS. WEB OPENINGS SHALL BE LOCATED IN THE MIDDLE 1/3 OF BEAM DEPTH. WEB REINFORCEMENT IS NOT REQUIRED FOR WEB OPENINGS LESS THAN 4" DIAMETER OR 3" X 3". A MAXIMUM OF ONE WEB OPENING IS PERMITTED FOR EACH BEAM NOT HAVING WEB
REINFORCEMENT.
4.15 STRUCTURAL STEEL CONTRACTOR SHALL COORDINATE THE BOTTOM OF BASE PLATE ELEVATION WITH THE TOP OF CONCRETE ELEVATION. IN CASE OF CONFLICT, THE CONTRACTOR SHALL MAKE ALLOWANCE IN HIS BID FOR MORE STRINGENT REQUIREMENTS.
4.16 PAINT STRUCTURAL STEEL IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. DO NOT PAINT STEEL SURFACES TO BE ENCASED IN CONCRETE OR RECEIVE SPRAYED ON FIREPROOFING, CONNECTIONS DESIGNATED AS SLIP CRITICAL, OR TO BE WELDED.
5.00 MASONRY
5.01 CONCRETE MASONRY DESIGN AND CONSTRUCTION SHALL CONFORM TO ACI 530, BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY
STRUCTURES AND ACI 530.1, SPECIFICATIONS FOR CONCRETE MASONRY CONSTRUCTION.
5.02 PROVIDE NORMALWEIGHT, HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING TO ASTM C90, fc' = 1900 PSI (NET), UNLESS
NOTED OTHERWISE.
5.03 PROVIDE MASONRY CONSTRUCTION WITH MINIMUM COMPRESSIVE STRENGTH, f'm = 1500 PSI.
5.04 PROVIDE TYPE "S" OR TYPE "M" MORTAR IN ACCORDANCE WITH ASTM C270, UNLESS NOTED OTHERWISE.
5.05 VERTICAL CELLS SHALL BE REINFORCED WITH #5 @24" O.C. MINIMUM, UNLESS NOTED OTHERWISE IN THE CONTRACT DRAWINGS. VERTICAL REINFORCING SHALL BE CONTINUOUS (LAPPED 48 BAR DIAMETERS AT SPLICES) AND HELD IN POSITION AT THE TOP AND BOTTOM OF THE GROUT
POUR. UNO, POSITION VERTICAL REINFORCING IN THE CENTER OF THE CELL.
5.06 PROVIDE GROUT FOR REINFORCED MASONRY IN ACCORDANCE WITH ASTM C476. GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE. GROUT SHALL BE FLUID CONSISTENCY. FLUID CONSISTENCY SHALL MEAN THAT CONSISTENCY AS FLUID AS POSSIBLE FOR POURING WITHOUT SEGREGATION OF THE CONSTITUENT PARTS. FILL ALL CELLS BELOW GRADE WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED AT THE TIME OF POURING BY VIBRATING AND THEN RECONSOLIDATED BY AGAIN PUDDLING LATER, BEFORE PLASTICITY IS LOST. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF THE GROUT
1-1/2 INCHES BELOW THE TOP OF THE UPPERMOST UNIT.
5.07 PROVIDE HORIZONTAL JOINT REINFORCEMENT COMPLYING WITH ASTM A82, NO. 9 GAUGE OR HEAVIER, ZINC COATED, PLACED 16 INCHES ON CENTER IN 8" NOMINAL CMU WALLS AND 8" ON CENTER IN 12" NOMINAL CMU WALLS, UNLESS NOTED OTHERWISE.
5.08 PROVIDE RUNNING BONDS WITH VERTICAL JOINTS LOCATED AT CENTER OF MASONRY UNITS IN THE ALTERNATE COURSE BELOW, UNLESS
NOTED OTHERWISE.
5.09 ALL MASONRY UNITS SHALL BE FREE OF EXCESSIVE DUST AND DIRT AT THE TIME THEY ARE LAYED BY THE MASON.
5.10 ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS IN ALL REINFORCED MASONRY WALLS SHALL BE FULLY BEDDED IN MORTAR. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM EACH FACE OF THE UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE
SHELLS, BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE VERTICAL COURSES.
5.11 PROVIDE VERTICAL CONTROL JOINTS BETWEEN REINFORCED MASONRY WALLS AND MASONRY PARTITION WALLS AND AS INDICATED IN THE
STRUCTURAL CONTRACT DRAWINGS.
1.00 GENERAL NOTES
1.01 THESE DRAWINGS ADDRESS ONLY THE STRUCTURAL DESIGN OF THE STRUCTURE. THE DIMENSIONAL LAYOUT OF THE STRUCTURE HAS BEEN DICTATED TO JOE DEREUIL ASSOCIATES IN ORDER TO PRODUCE STRUCTURAL DESIGN DOCUMENTS. NO REPRESENTATION IS MADE REGARDING
CODE CONFORMANCE OF NON-STRUCTURAL ASPECTS OF THE STRUCTURE.
1.02 ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE, 2012.
1.03 THE STRUCTURE HAS BEEN DESIGNED UTILIZING THE FOLLOWING REFERENCES:
A. UFC 1-200-01, “GENERAL BUILDING REQUIREMENTS”
B. UFC 3-301-01, “STRUCTURAL ENGINEERING”, 1 JUNE 2013
C. UFC 3-310-04, “SEISMIC DESIGN FOR BUILDINGS”
D. INTERNATIONAL BUILDING CODE, 2012 (STRUCTURAL)
E. ANSI/ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
F. ACI 318-11, BUILDING CODE REQUIREMENTS FOR CONCRETE STRUCTURES
G. AISC STEEL CONSTRUCTION MANUAL 14TH EDITION
1.04 WIND LOADS - STRUCTURE HAS BEEN DESIGNED TO CONFORM TO THE WIND PROVISIONS OF ASCE 7-10. SEE WIND PRESSURE DIAGRAM &
CHART FOR THE FOLLOWING:
A. BASIC WIND SPEED
B. WIND IMPORTANCE FACTOR & BLDG CATEGORY
C. WIND EXPOSURE CATEGORY
D. INTERNAL PRESSURE COEFFICIENT
E. COMPONENT & CLADDING WIND PRESSURES
1.05 DESIGN GRAVITY LOADS ARE AS FOLLOWS:
A. SUPERIMPOSED DEAD LOADS:
1. MECHANICAL, ELECTRICAL: 3 PSF
2. ROOFING: 5 PSF
B. LIVE LOADS: (MAY BE REDUCED PER CODE)
1. ROOFS: 20 PSF
1.06 DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR
TO THOSE SHOWN.
1.07 VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY STRUCTURAL ENGINEER OF ANY
DISCREPANCY.
1.08 THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. TAKE NECESSARY PRECAUTIONS TO PROTECT THE EXISTING STRUCTURE AND ITS FOUNDATION AND TO LIMIT, TO THE EXTENT POSSIBLE, THE EFFECTS CONSTRUCTION OF THE NEW STRUCTURE HAS ON THE EXISTING STRUCTURE.
1.09 COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL. NOTIFY STRUCTURAL ENGINEER OF ANY CONFLICT AND/OR OMISSION. CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. FOR ADDITIONAL OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS, SEE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS.
1.10 REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE STRUCTURAL ENGINEER. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION.
2.00 FOUNDATIONS AND SLAB-ON-GRADE
2.01 THE DESIGN OF FOUNDATIONS AND SLAB ON GRADE ARE BASED ON THE CRITERIA ESTABLISHED IN THE GEOTECHNICAL REPORT BY UNIVERSAL ENGINEERING SCIENCES, INC., PENSACOLA FL; UES PROJECT #1730.1400072.0000, DATED NOVEMBER 14, 2014. THE RECOMMENDATIONS
OF THAT REPORT SHALL BE CONSIDERED AN INTEGRAL PART OF THE CONTRACT DOCUMENTS.
2.02 SHALLOW FOUNDATIONS HAVE BEEN DESIGNED FOR AN ALLOWABLE NET SOIL BEARING PRESSURE OF 2,500 PSF.
2.03 CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY PROTECTING ALL EXCAVATION SLOPES.
2.04 DEWATER TO AT LEAST TWO FEET BELOW BOTTOM OF LOWEST FOUNDATION IF GROUNDWATER IS ENCOUNTERED.
3.00 REINFORCED CONCRETE
3.01 ALL CONCRETE WORK SHALL CONFORM TO ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315, DETAILING MANUAL. DETAIL ALL CONCRETE WALLS AND BEAMS ON THE SHOP DRAWINGS IN ELEVATION UNLESS SPECIFICALLY APPROVED OTHERWISE. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.
3.02 UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE THE FOLLOWING MINIMUM 28 DAY COMPRESSIVE
STRENGTH:
A. FOUNDATIONS 3000 PSI
B. PIERS 4000 PSI
3.03 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.
3.04 THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE OWNER'S TESTING LABORATORY.
RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH IS THE CONTRACTOR'S.
3.05 USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.
3.06 TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCE DURING ALL CONSTRUCTION ACTIVITIES. "STICKING” DOWELS INTO
WET CONCRETE IS NOT PERMITTED.
3.07 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED; STAGGER SPLICE WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION SPLICES (CLASS "B") UNLESS NOTED OTHERWISE. TERMINATE BARS WITH STANDARD
HOOKS.
3.08 REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS NOTED OTHERWISE (PER ACI 318-05 PAR.7.7.1):
A. CONCRETE AGAINST EARTH (NOT FORMED): 3"
B. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER:
1. #6 THROUGH #18 BARS: 2"
2. #5 BARS AND SMALLER: 1-1/2"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
1. SLABS AND WALLS: 1"
2. BEAMS (STIRRUPS) AND COLUMNS (TIES): 1-1/2"
6.00 COLD FORMED METAL FRAMING
6.01 COLD FORMED METAL STUDS: GALVANIZED STEEL PER ASTM A525, G60 COATING MEETING THE REQUIREMENTS OF ASTM A446 GRADE A, WITH A MINIMUM YIELD STRENGTH OF 33,000 PSI.
6.02 ALL STUDS INDICATED SHALL BE 18 GAGE MINIMUM AND HAVE 1-5/8” WIDE FLANGES WITH A ½” LIP AND SHALL BE SPACED AT 1’-4” O.C, UNLESS NOTED OTHERWISE. ALL TRACK INDICATED SHALL BE 18 GAGE MINIMUM AND HAVE 1-1/4” WIDE FLANGES.
6.03 CONNECTION REQUIREMENTS (MINIMUMS):
A. TRACK TO STEEL OPTIONS
1. 0.145” DIA. P.A.F.s @ 8” O.C. STAGGERED.
2. #12 HWH SELF TAPPING TEK SCREWS @ 8” O.C.
B. TRACK TO BLOCK – (2) 3/16” TAPCON SCREW ANCHORS AT EACH JOIST/STUD LOCATION EMBED 1¼” MINIMUM INTO BLOCK/GROUT.
C. TRACK TO CONCRETE OPTIONS:
1. 0.145” DIA. P.A.F.s @ 8” O.C. STAGGERED EMBED 1¼” MIN.
2. 3/16” TAPCON SCREW ANCHORS @ 8” O.C. EMBED 1¼” MIN.
D. STUD TO STUD OR JOIST TO JOIST: (4) #10 HWH SELF TAPPING TEK SCREWS, MIN.
E. STUD TO TRACK – (2) #10 HWH SELF TAPPING TEK SCREWS.
F. STUD TO STEEL OPTIONS
1. (2) 0.145" DIA. P.A.F.'s
2. (2) #12 HWH SELF TAPPING TEK SCREWS.
7.00 POST INSTALLED ANCHORS
7.01 ANCHOR BASIS OF DESIGN, FOR ALL POST INSTALLED ANCHORS ARE HILTI, INC PRODUCTS. CONTACT HILTI AT (800) 879-8000.
7.02 WHERE CALLED FOR IN THE CONSTRUCTION DRAWINGS, EPOXY (ADHESIVE) SHALL BE HILTI HIT-HY 200 OR EQUIVALENT SYSTEM.
PROVIDE GALVANIZED A-307 OR EQUIV. ALL-THREAD ROD AND GALV. WASHERS AND NUTS, TYPICAL.
7.03 WHERE CALLED FOR IN THE CONSTRUCTION DRAWINGS, EXPANSION (EXP.) ANCHORS SHALL BE GALVANIZED HILTI KWIK BOLT 3, INCLUDING NUT AND WASHER, WITH 4" EMBEDMENT INTO GROUT FILLED CMU OR CONCRETE. ANCHOR EDGE DISTANCE SHALL BE 4" MINIMUM AT ALL
LOCATIONS.
7.04 INSTALL ALL ANCHORS PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING.
7.05 THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE CONTRACTING OFFICER MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.
7.06 ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ANCHORS, ANCHOR EMBEDMENT, AND PROXIMITY OF ANCHORS TO EDGES OF CONCRETE AND/OR MASONRY. INSTALL ANCHORS IN ACCORDANCE WITH THE SPACING AND EDGE CLEARANCES INDICATED IN
THESE DRAWINGS.
WIND LOAD DETERMINATION ASSUMPTIONS - INTERNATIONAL BUILDING CODE 2012
ROOF SLOPE
145 C 17.5 0.5 ON 12 II OPEN
ULTIMATE DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING (PSF)
ROOF ZONE 3 ROOF ZONE 2 ROOF ZONE 1 WALL ZONE 4 WALL ZONE 5
77.5 -119.0 -60.1 60.2 -40.1 -40.1
> 24.7, < 98.7 59.2 -60.1 -60.1 60.2 -40.1 -40.1
38.8 -39.7 -39.7 60.2 -40.1 -40.1
-39.7
-39.7
-39.7
NOTES:
1. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED,
OTHERWISE USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.
2. THE EDGE STRIP, a = 5.0 FT.
3. PRESSURES SHALL BE APPLIED IN ACCORDANCE WITH THE FIGURE SHOWN ON THIS SHEET.
< 24.7
> 98.7
WIND VELOCITY
(MPH)
EXPOSURE
CATEGORY
MEAN ROOF
HEIGHT (FT.)
RISK
CATEGORY
ENCLOSURE
CATEGORY
EFF.
AREA
(SQ. FT)
4. PRESSURES GIVEN ARE ULTIMATE LOADS TO BE USED WITH STRENGTH DESIGN. FOR SERVICE
LOADS TO BE USED WITH ALLOWABLE STRESS DESIGN, MULTIPLY THE PRESSURES BY 0.60.
SEE TABLES 2.3 AND 2.4 IN ASCE 7-10 FOR MORE INFORMATION ON LOAD COMBINATIONS.
59.2
59.2
38.8
38.8
38.8
38.8
60.2
60.2
60.2
WIND LOAD DIAGRAM
a a a a a a a a2
5 5
EXISTING
STRUCTURE
IA
R
E
OF
R C
SP
E C
IA
AN
N
P
ER
L O
AT
IO
M M
S
CO
D
DESIGNED BY:
A
IR
F O R C E S P E C
IA
L O P E R A T
IO
N S C
O M M A N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
A P P R O V E D
C H
IE
F E N G
IN
E E R
A P P R O V E D
C
IV
IL
E N G
IN
E E R
R E V
D A T E
D E S C R
IP
T
IO
N
A P P 'D
S P E C
IA
L O
P E R A T
IO
N S E N G
IN
E E R S Q U A D R O N
H U R L B U R T F
IE
L D F L O R
ID
A
S T A N D A R D D L A Y O U T (2 4" X 6"
G E
N E
R A
L N
O T
E S
W
IN
D
I N
F O
R M
A T
IO
N
S0
R E N O V A T E R H S W A S H R A C K
B U
IL
D
IN
G
FTEV 09-1033
JTG
JTG
A
2 3 4
B
S3EXISTING CONTINUOUS
FOUNDATION
CUT OUT EXISTING CMU WALL
AS REQUIRED TO INSTALL
NEW CONCRETE PIERS (TYP.)
'-0 /8
7"18'-7"11'-4"18'-7"7"
REINF. CONCRETE PIER (RCP14X14)
(TYP. X (4) LOCATIONS)
W8X24 COLUMN (TYP. X (4)
LOCATIONS)
EXISTING CMU
PILASTER (TYP.)
EXISTING TRENCH DRAIN
TO BE REMOVED AND
REPLACED WITH NEW
CONCRETE PAVEMENT;
SEE CIVIL
EXISTING WASH
RACK STRUCTURE
CONCRETE
PAVEMENT;
SEE CIVIL
TRENCH DRAIN;
SEE CIVIL
TRENCH DRAIN;
SEE CIVIL
3"
49'-8"
ExWF2.0ExWF2.0ExWF2.0
EXISTING 8" CMU SCREEN
WALL
EXISTING 12" CMU WALL
BID OPTION #1
EXISTING TRENCH DRAIN
TO BE REMOVED AND
REPLACED WITH NEW
CONCRETE PAVEMENT;
SEE CIVIL
BID OPTION #1
CONCRETE
PAVEMENT;
SEE CIVIL
2" CONCRETE TOPPING SLAB:
CONCRETE TOPPING SHALL BE A 3000 PSI FIBER
REINFORCED PEA-GRAVEL CONCRETE.
CONTROL JOINTS SHOULD OVERLAY EXISTING SLAB
JOINTS. ISOLATE TOPPING FROM WALLS WITH 1/2"
PREMOLDED JOINT FILLER. SEE NOTE 1 THIS SHEET
FOR EXISTING SLAB PREPARATION AND PROCEDURE.
POUR SLOPED SLAB
TRANSITION WITH
CIVIL SLAB
DN
FOUNDATION LEGEND AND NOTES
= TOP OF FOUNDATION REFERENCE ELEVATION(TOF = XX.XX')
= REINFORCED CONCRETE PIER; SEE SECTIONS IN S300
SERIES FOR REINFORCING
RCPXXX
LEGEND
= EXISTING CONTINUOUS WALL FOOTINGExWF2.0
NOTES
1. SURFACE PREPARATION FOR 2" TOPPING SLAB:
-WATERBLAST EXISTING SURFACE AT 4000 PSI
-WITHIN 30 MINUTES OF POURING TOPPING (HAVE CONCRETE TRUCK
READY): BRUSH ON A SLURRY COAT OF:
1 PART PORTLAND CEMENT
1 PART MASON’S SAND
ENOUGH WATER TO MAKE CREAMY
-POUR TOPPING SLAB
-CURE WITH CURING COMPOUND OR MOIST CURE
IA
R
E
OF
R C
SP
E C
IA
AN
N
P
ER
L O
AT
IO
M M
S
CO
D
DESIGNED BY:
A
IR
F O R C E S P E C
IA
L O P E R A T
IO
N S C
O M M A N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
A P P R O V E D
C H
IE
F E N G
IN
E E R
A P P R O V E D
C
IV
IL
E N G
IN
E E R
R E V
D A T E
D E S C R
IP
T
IO
N
A P P 'D
S P E C
IA
L O
P E R A T
IO
N S E N G
IN
E E R S Q U A D R O N
H U R L B U R T F
IE
L D F L O R
ID
A
S T A N D A R D D L A Y O U T (2 4" X 6"
F O
U N
D A
T
IO
N P
L A
N
S1
R E N O V A T E R H S W A S H R A C K
B U
IL
D
IN
G
FTEV 09-1033
JTG
JTG
02 MAR 2015
PLAN
NORTH
1/4" = 1'-0"S1
1 FOUNDATION PLAN
0 2' 4' 8'
SCALE 1/4":1'-0"
1'
ROOF FRAMING NOTES AND LEGEND
LEGEND
= BERRIDGE “DEEP-DECK” PREFINISHED, GALVANIZED 1 1/2"
STRUCTURAL 24 GA. METAL DECKING WITH CORRUGATED
PROFILE (OR EQUIVALENT), INSTALLED WITH PREFINISHED,
GASKETED FASTENERS. REFER TO ARCHITECTURAL FOR
INSTALLATION DETAILS AND FINISH REQUIREMENTS.
ROOF DECK MINIMUM SECTION PROPERTIES:
(fy > 40 ksi) ( TH= 0.024 in, I= 0.1073 in^4/ft)
INSTALLATION/ATTACHMENT REQUIREMENTS:
METAL DECK MANUFACTURER SHALL DESIGN FASTENER
TYPE, SIZE AND SPACING TO MEET WIND LOADS SPECIFIED
ON SHEET S0.
A
3 4
B
S3
'-0 /8
9"18'-7"11'-4"18'-7"9"
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
CS8x3.5x070
W X
W X
W X
W X
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
CS8x3.5x070 CS8x3.5x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ZS8x2.75x070
ROOF EDGE (TYP.) STEEL COLUMN
BELOW (TYP.)
STEEL BEAM TO
ATTACH TO EXISTING
CMU PILASTER (TYP.)
EXISTING WASH
RACK STRUCTURE
E Q
E Q
E Q
E Q
E Q
50'-0"
(TYP.)
2'-4" LAP
(TYP.)
2'-4" LAP
S2
S2
BID OPTION #1
(2) 3/4" DIA. BOLTS
8" Z-PURLIN;
SEE PLAN
STRUCTURAL
METAL ROOF DECK;
SEE PLAN
W12 BEAM; SEE PLAN
W12 BEAM; SEE
PLAN
NOTE:
USE SIMILAR
CONNECTION FOR
C-MEMBERS AT EAVES
A
A
SECTION A-A
1 1/4" 4" 1 1/4"
GL
(2) 3/4" DIA. BOLTS
W12 BEAM; SEE
PLAN
(8) 1/2" DIA. BOLTS
STRUCTURAL
METAL ROOF DECK;
SEE PLAN 1" 11" 4" 11" 1"
2'-4" LAP
2" 4"
2"
GL
(2) 3/4" DIA. BOLTS
W12 BEAM; SEE
PLAN
STRUCTURAL
METAL ROOF DECK;
SEE PLAN
8" 16 GA.
CLOSURE CHANNEL
9"
B.O. FASCIA
14'-10"
7/8" GALVANIZED METAL
FURRING @ 12" O.C.
2-1/2" 18 GA GALVANIZED METAL
FASCIA FRAMING @ 16" O.C.
ALUMINUM FASCIA PANEL;
SEE ARCH.
CONTINUOUS 2" x 2" 16 GA
GALVANIZED STEEL
ATTACHEMENT ANGLE
FASTENED @ 12" O.C.
V A R
IE
S
IA
R
E
OF
R C
SP
E C
IA
AN
N
P
ER
L O
AT
IO
M M
S
CO
D
DESIGNED BY:
A
IR
F O R C E S P E C
IA
L O P E R A T
IO
N S C
O M M A N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
A P P R O V E D
C H
IE
F E N G
IN
E E R
A P P R O V E D
C
IV
IL
E N G
IN
E E R
R E V
D A T E
D E S C R
IP
T
IO
N
A P P 'D
S P E C
IA
L O
P E R A T
IO
N S E N G
IN
E E R S Q U A D R O N
H U R L B U R T F
IE
L D F L O R
ID
A
S T A N D A R D D L A Y O U T (2 4" X 6"
R O
O F
F R
A M
IN
G
P L
A N
S2
R E N O V A T E R H S W A S H R A C K
B U
IL
D
IN
G
FTEV 09-1033
JTG
JTG
02 MAR 2015
1/4" = 1'-0"S2
1 ROOF FRAMING PLAN
PLAN
NORTH
0 2' 4' 8'
SCALE 1/4":1'-0"
1'
1" = 1'-0"S2
2 Z-PURLIN CONNECTION DETAIL (BID OPTION #1)
1" = 1'-0"S2
3 Z-PURLIN SPLICE DETAIL (BID OPTION #1)
1" = 1'-0"S2
4 RAKE EDGE DETAIL (BID OPTION #1)
SLAB ON GRADE
0"
EXISTING
FOUNDATION
-8"
A
TOP OF STEEL
16' - 0"
B
L3x3x1/4" ERECTION
SEAT, FAB. OPTION
W-SHAPE BEAM TO COLUMN
1/4
TOP PARAPET
18' - 8"
EXISTING FOOTING
1" THICK BASE PLATE W/
MIN. (4)-3/4" DIA. HEADED
ANCHOR BOLTS W/ MIN.12" EMBED.
COLUMN SITS ON 1-1/2" GROUT
BED FOR LEVELING.
14"X14" CONCRETE PIER; W/ (4) #7
VERTICALS AND #3 TIES @ 10" O.C.;
PROVIDE (3) #3 TIES @ 3" O.C. TOP &
BOTTOM OF PIER; (SEE DETAIL ABOVE)
CONCRETE PAVEMENT;
SEE CIVIL
RCP14x14 PIER DETAIL
#3 TIES SPACED
PER NOTE BELOW
VERTICALS PER
NOTE BELOW
W8 COLUMN BASE PLATE GALVANIZED ANCHOR ROD
16'-9 1/2"
TOP OF STEEL
WORK POINT
WORK POINT
1' -2
1'-2"
TYP.
1 1/2" CLR.
4" T H R D
U .N .O
1/ 2" G R O U
THEAVY HEX NUTS T&B
2"x2" PLATE WASHER T&B
8"
9"
2 1/4" 4 1/2" 2 1/4"
1/ 4"
1/ 2"
1/ 4"
STEEL COLUMN;
SEE PLAN
STEEL BEAM;
SEE PLAN
Z-PURLINS;
SEE PLAN
ROOF DECK;
SEE PLAN 12
1/2
19'-0 3/8"
C-EAVE STRUT;
SEE PLAN
#5 U-BAR (ANCHOR
REINFORCEMENT)
3' -0
8"
DRILL & EPOXY DOWELS INTO
EXISTING CONCRETE FOOTING;
PROVIDE 9" EMBEDMENT
(G.C. VERIFY)
(2) L4x4x1/4 W/ (3) 3/4" DIA.
BOLTS TO BEAM AND (4) 3/4"
DIA. x 6" EXPANSION ANCHORS
INTO EXISTING CMU WALL
M
IN
1/ 4" T
Y P
3" T
Y P
W-SHAPE BEAM TO CMU WALL
1/4" CAP PLATE
ON COLUMN
M
IN
1/ 4" T
Y P
3" T
Y P
3/8"x4" SHEAR TAB
W/ MAX. NUMBER
OF 3/4" THRU-BOLTS
1 1/4" TYP.
G.C. TO GROUT SOLID IF
EXISTING CMU IS NOT
GROUT FILLED AT
ANCHOR LOCATIONS
1 1/4" TYP.
1 1/4" TYP.
EXISTING FOOTING
EXISTING CMU PILASTER
NOTE:
GRIND FACE OF EXISTING CMU
SMOOTH PRIOR TO INSTALLING
ANGLE CONNECTIONS (TYP.)
IA
R
E
OF
R C
SP
E C
IA
AN
N
P
ER
L O
AT
IO
M M
S
CO
D
DESIGNED BY:
A
IR
F O R C E S P E C
IA
L O P E R A T
IO
N S C
O M M A N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
A P P R O V E D
C H
IE
F E N G
IN
E E R
A P P R O V E D
C
IV
IL
E N G
IN
E E R
R E V
D A T E
D E S C R
IP
T
IO
N
A P P 'D
S P E C
IA
L O
P E R A T
IO
N S E N G
IN
E E R S Q U A D R O N
H U R L B U R T F
IE
L D F L O R
ID
A
S T A N D A R D D L A Y O U T (2 4" X 6"
S E
C T
IO
N
S
D E
T A
IL
S
S3
R E N O V A T E R H S W A S H R A C K
B U
IL
D
IN
G
FTEV 09-1033
JTG
JTG
02 MAR 2015
3/4" = 1'-0"S3
1 SECTION AT COLUMN (BID OPTION #1)
A42
A5
A4 1
A5
A6
A6
UP UP
EXISTING
50'-0"
'-8
EX
IS
TI
NG
'-0
EX
IS
TI
NG
'-8
EX
IS
TI
NG
W
A L L
/ N
EW
R
OO
F
ST
RU
CT
UR
E
(B
ID
O P T
IO
N
#1
'-0
WASH HALL
WASH HALL
CORR
WAITING
EQUIP.
BID OPTION #1
2020 20
1 2 3 4
18'-8" 11'-4" 18'-8" 8"
A
B
'-0
/8
1. SEE ADDITIONAL INFORMATION ON SHEET G2 FOR DESCRIPTION
OF BID OPTOIN #1.
2. SEE CIVIL AND PLUMBING DRAWINGS FOR ADDITIONAL TRENCH
DRAIN CLARIFICATOINS.
3. SEE ENVIRONMENTAL NOTES ON G2 FOR LEAD BASED PAINT
CONCERNS.
G E N E R A L N O T E S
CORR
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
N
EW
W O
R K
FL
O
O R
P
LA
N
A1
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
1/4" = 1'-0"A4 A1
1 FLOOR PLAN - BASE BID
TRUE
NORTH
PROJECT
NORTH 0'2'4' 4' 8'
K E Y N O T E S
1 PREPARE AND PAINT EXISTING GALVANIZED STEEL
DOOR WITH LOUVERS AND PREVIOUSLY PAINTED
FRAME
2 REMOVE EXISTING HOLLOW METAL DOOR AND
FRAME. REPLACE WITH NEW GALVANIZED STEEL
DOOR & FRAME IN EXISTING OPENING, WITH NEW
HARDWARE. DOOR OPENING HEIGHT AND WIDTH
TO BE VERIFIED IN FIELD AFTER NEW CONCRETE
FLOOR TOPPING IS POURED
3 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
LADDER
4 PREPARE AND PAINT PREVIOUSLY PAINTED
ELEVATED PLATFORM STRUCTURE WITH STAIRS
5 REMOVE EXISTING METAL WALL LOUVER AND
REPLACE WITH NEW 4'-0" X 4'-0" +/- PREFINISHED
METAL, STORMPROOF LOUVER. INSTALL WITH
PREFINISHED METAL SILL PAN FLASHING AND
BACKER ROD & SEALANT ALL AROUND. VERIFY
LOUVER SIZE IN FIELD.
6 REMOVE EXISTING A/C UNIT IN PREPARATION FOR
INSTALLATION OF NEW UNIT BY OTHERS (N.I.C.)
7 EXISTING CONCRETE SLAB TO REMAIN, PROVIDE
PRESSURE WASH CLEANING
8 REMOVE EXISTING VCT, RUBBER BASE, AND ALL
ADHESIVE TRACES IN PREPARATION FOR NEW
FINISHES
9 EXISTING GLASS BLOCK WINDOW TO REMAIN,
PROTECT (TYP.)
10 NEW TRENCH DRAIN SET IN CONCRETE; SEE CIVIL
AND PLUMBING
11 MAINTAIN EXISTING EDGE OF CONCRETE
PAVEMENT TO LOCATE NEW TRENCH DRAIN
12 EXISTING CONCRETE CONCRETE PAVEMENT TO
REMAIN
13 EXISTING CMU WALL TO REMAIN, PAINTED
14 EXISTING TRENCH DRAIN TO BE REMOVED, FILL IN
AND PREPARE SUBSTRATE FOR NEW CONCRETE
PAVEMENT
15 NEW CONCRETE PAVEMENT SLOPED TO DRAIN;
SEE CIVIL
16 SAWCUT EXISTING WALL AND CONSTRUCT NEW
CONCRETE PIER WITH STEEL COLUMN , PAINTED;
SEE STRUCTURAL (BID OPTION #1)
17 SAWCUT EXISTING CONCRETE SLAB FOR NEW
TRENCH DRAIN; SEE CIVIL
18 NEW 3" X 3" PREFINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK, SURFACE
DISCHARGE (BID OPTION #1)
19 NEW EQUIPMENT; SEE PLUMBING
20 NEW EXHAUST FLUES; SEE PLUMBING
21 NEW CONCRETE PAVEMENT
22 NEW 2" THICK HIGH STRENGTH CONCRETE FLOOR
TOPPING WITH CLEAR FLOOR SEALER. TERMINATE
AT DOOR THRESHOLD EDGE
23 CONTINUOUS TRENCH DRAIN (BID OPTION #1)
24 CLEANOUT; SEE PLUMBING
25 CONSTRUCTION JOINT IN PAVEMENT, TYP.
26 WARP CONCRETE UP TO MEET NEW FLOOR HEIGHT
IN ROOM 104 - WAITING (+0'-2")
1/4" = 1'-0"A4 A1
2 FLOOR PLAN - BID OPTION #1
0'2'4' 4' 8'
A6
A6
1 12
1 33
UP UP
MEZZANINE
PLATFORM
BID OPTION #1
6 66
1 2 3 4
A
B
1. SEE ADDITIONAL INFORMATION ON SHEET G2 FOR DESCRIPTION
OF BID OPTOIN #1.
2. SEE ENVIRONMENTAL NOTES ON G2 FOR LEAD BASED PAINT
CONCERNS.
G E N E R A L N O T E S
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
M
EZ
ZA
N
IN
E
PL
AN
A2
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
TRUE
NORTH
PROJECT
NORTH 0'2'4' 4' 8'
1/4" = 1'-0"A4 A2
1 MEZZANINE PLAN
K E Y N O T E S
1 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
TUBE RAILING SYSTEM
2 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
LADDER
3 PREPARE AND PAINT PREVIOUSLY PAINTED
ELEVATED PLATFORM STRUCTURE WITH STAIRS
4 OUTLINE OF NEW ROOF ABOVE (BID OPTION #1)
5 NEW STEEL COLUMN, PAINTED; SEE STRUCTURAL
(BID OPTION #1)
6 NEW EXHAUST FLUES; SEE PLUMBING
7 NEW 3" X 3" PREFINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK, SURFACE
DISCHARGE (BID OPTION #1)
8 EXISTING CONCRETE SLAB TO REMAIN, PROVIDE
PRESSURE WASH CLEANING
A6
A6
BID OPTION #1
6 66
1 2 3 4
A
B
1. SEE ADDITIONAL INFORMATION ON SHEET G2 FOR DESCRIPTION
OF BID OPTOIN #1.
2. SEE ENVIRONMENTAL NOTES ON G2 FOR LEAD BASED PAINT
CONCERNS.
G E N E R A L N O T E S
LIGHT FIXTURES; SEE
ELECTRICAL
L E G E N D I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
A3
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
TRUE
NORTH
PROJECT
NORTH 0'2'4' 4' 8'
1/4" = 1'-0"A4 A3
1 REFLECTED CEILING PLAN
K E Y N O T E S
1 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
BAR JOISTS, TYP.
2 PREPARE AND PAINT PREVIOUSLY PAINTED
GALVANIZED STEEL DECK
3 PREPARE AND PAINT EXISTING BAR JOIST, TYP.
4 PREPARE AND PAINT EXISTING GALVANIZED STEEL
DECK
5 NEW STEEL ROOF FRAMING, PAINTED; SEE
STRUCTURAL (BID OPTION #1)
6 NEW EXHAUST FLUES; SEE PLUMBING
01-Floor
Top of CMU 18'-8"
01.5-Mezzanine 9'-0"
11 12
15'-0"
1/2" / 1'-0"
4'-0"
16'-10" Top of Deck
A4 3___
A4
A6
BID OPTION #1
01-Floor 0"
Top of CMU 18'-8"
01.5-Mezzanine 9'-0"
15'-0"
4'-0"
1/2" / 1'-0"
A4 3 ___
A4
A6
BID OPTION #1
STEEL BEAM, BEYOND,
PAINTED; SEE
STRUCTURAL
REGLET
18'-0"
PREFINISHED,
GALVANIZED
CORRUGATED
STRUCTURAL METAL
ROOF DECK; SEE
CLARIFICATIONS IN
GENERAL NOTE #3
STEEL FRAMING,
PAINTED; SEE
STRUCTURAL
NEW REGLET WITH SEALANT
SET IN EXISTING COURSING
JOINT (CUT JOINT TO
RECIEVE REGLET)
EXISTING CONCRETE
MASONRY WALL
T.o.S 16'-9 1/2"
FACE OF PILASTER
BEYOND
PREFINISHED
GASKETED FASTENERS
@ 12" O.C.
PREFINISHED METAL
FLASHING SET IN
REGLET
FLASHING WITH REGLET
BEYOND @ PILASTER
6" MIN.
ROOFING
MANUFACTURER'S
PREFORMED
CLOSURE PIECE
BETWEEN RIBS
STEEL BEAM,
PAINTED; SEE
STRUCTURAL
B.O. FASCIA
15'-0"
STEEL FRAMING,
PAINTED; SEE
STRUCTURAL
PREFINISHED, GALVANIZED
CORRUGATED STRUCTURAL
METAL ROOF DECK; SEE
CLARIFICATIONS IN GENERAL
NOTE #3
STEEL COLUMN,
PAINTED; SEE
STRUCTURAL
5" x 5" PREFINISHED
METAL GUTTER
3" x3" PREFINISHED
METAL DOWNSPOUT
BEYOND
T.o.S 16'-0"
1"
1. REMOVE ALL EXISTING SURFACE MOUNTED WALL BRACKETRY,
SIGNAGE, AND OTHER MISCELLANEOUS COMPONENTS NOT
SHOWN ON THESE ELEVATIONS OR REQUIRED BY THE NEW
WORK. REPAIR ANY RELATED WALL DAMAGE TO MATCH
ADJACENT SURFACES.
2. SEE ADDITIONAL INFORMATION ON SHEET G2 FOR
DESCRIPTION OF BID OPTOIN #1.
3. THE PREFINISHED, GALVANIZED CORRUGATED METAL
ROOFING IDENTIFIED IN BID OPTION #1 DIFFERS FROM THE
HURLBURT BASE STANDARD STANDING SEAM METAL ROOFING
INCLUDED IN THE PROJECT SPECIFICATIONS, BUT HAS BEEN
PRE-APPROVED. THE BASIS OF DESIGN PRODUCT FOR USE IS
BERRIDGE “DEEP-DECK”, 24 GAGE PANEL WITH 1.5 INCH HIGH
PANEL PROFILE. AN APPROVED EQUAL PRODUCT MEETING
THE PERFORMANCE REQUIREMENTS OF THIS SPECIFIC
PANEL, INCLUDING WIND LOAD REQUIREMENTS INDICATED
ON THE DRAWINGS, IS ACCEPTABLE.
4. SEE ENVIRONMENTAL NOTES ON G2 FOR LEAD BASED PAINT
CONCERNS.
G E N E R A L N O T E S
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
EL
EV
AT
IO
N S
A4
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
1/4" = 1'-0"A1 A4
1 EXTERIOR ELEVATION - EAST
1/4" = 1'-0"A1 A4
2 EXTERIOR ELEVATION - WEST
0'2'4' 4' 8'
0'2'4' 4' 8'
K E Y N O T E S
1 REMOVE EXISTING A/C UNIT IN PREPARATION FOR
INSTALLATION OF NEW UNIT BY OTHERS (N.I.C.)
2 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
TUBE RAILING SYSTEM
3 PREPARE AND PAINT PREVIOUSLY PAINTED METAL
FASCIA PANELS
4 PREPARE AND PAINT PREVIOUSLY PAINTED
ELEVATED PLATFORM STRUCTURE WITH STAIRS
5 PREPARE AND PAINT PREVIOUSLY PAINTED SPLIT
FACE CMU WALLS
6 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
LADDER
7 PREPARE AND PAINT EXISTING GALVANIZED STEEL
DOOR WITH LOUVERS AND PREVIOUSLY PAINTED
FRAME
8 REPAIR DAMAGE TO STUCCO FINISH
9 REPAIR DAMAGE TO FASCIA EDGE AND METAL
PANEL FASCIA SYSTEM
10 PREPARE AND PAINT PREVIOUSLY PAINTED AND
STUCCO FINISHED CMU PILASTER
11 EXISTING SIGNAGE TO REMAIN, PROTECT
12 EXISTING METAL PARAPET FLASHING TO REMAIN
(UNPAINTED)
13 NEW STEEL COLUMN, PAINTED; SEE STRUCTURAL
(BID OPTION #1)
14 SAWCUT EXISTING WALL AND CONSTRUCT NEW
CONCRETE PIER WITH STEEL COLUMN , PAINTED;
SEE STRUCTURAL (BID OPTION #1)
15 NEW, PREFINISHED GALVANIZED STEEL FASCIA
PANEL SYSTEM (BID OPTION #1)
16 NEW 3" X 3" PREFINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK, SURFACE
DISCHARGE (BID OPTION #1)
17 REPAIR MINOR SETTLEMENT CRACKS IN JOINTS,
TYP.
3" = 1'-0"A4 A4
3 CANOPY / WALL DETAIL (BID OPTION #1)
3" = 1'-0"A4 A4
4 CANOPY EDGE DETAIL (BID OPTION #1)
0'2"4" 4" 8"
Top of CMU 18'-8"
01.5-Mezzanine 9'-0"
1 24
BID OPTION #1
121212
01-Floor 0"
Top of CMU 18'-8"
01.5-Mezzanine 9'-0"
1. REMOVE ALL EXISTING SURFACE MOUNTED WALL
BRACKETRY, SIGNAGE, AND OTHER MISCELLANEOUS
COMPONENTS NOT SHOWN ON THESE ELEVATIONS OR
REQUIRED BY THE NEW WORK. REPAIR ANY RELATED WALL
DAMAGE TO MATCH ADJACENT SURFACES.
2. SEE ADDITIONAL INFORMATION ON SHEET G2 FOR
DESCRIPTION OF BID OPTOIN #1.
3. THE PREFINISHED, GALVANIZED CORRUGATED METAL
ROOFING IDENTIFIED IN BID OPTION #1 DIFFERS FROM THE
HURLBURT BASE STANDARD STANDING SEAM METAL
ROOFING INCLUDED IN THE PROJECT SPECIFICATIONS, BUT
HAS BEEN PRE-APPROVED. THE BASIS OF DESIGN PRODUCT
FOR USE IS BERRIDGE “DEEP-DECK”, 24 GAGE PANEL WITH
1.5 INCH HIGH PANEL PROFILE. AN APPROVED EQUAL
PRODUCT MEETING THE PERFORMANCE REQUIREMENTS OF
THIS SPECIFIC PANEL, INCLUDING WIND LOAD
REQUIREMENTS INDICATED ON THE DRAWINGS, IS
ACCEPTABLE.
4. SEE ENVIRONMENTAL NOTES ON G2 FOR LEAD BASED PAINT
CONCERNS.
G E N E R A L N O T E S
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
EL
EV
AT
IO
N S
A5
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
1/4" = 1'-0"A1 A5
1 EXTERIOR ELEVATION - NORTH
1/4" = 1'-0"A1 A5
2 EXTERIOR ELEVATION - SOUTH
0'2'4' 4' 8'
0'2'4' 4' 8'
K E Y N O T E S
1 REMOVE EXISTING METAL WALL LOUVER AND
REPLACE WITH NEW 4'-0" X 4'-0" +/- PREFINISHED
METAL, STORMPROOF LOUVER. INSTALL WITH
PREFINISHED METAL SILL PAN FLASHING AND
BACKER ROD & SEALANT ALL AROUND. VERIFY
LOUVER SIZE IN FIELD.
2 REMOVE EXISTING A/C UNIT IN PREPARATION FOR
INSTALLATION OF NEW UNIT BY OTHERS (N.I.C.)
3 PREPARE AND PAINT PREVIOUSLY PAINTED SPLIT
FACE CMU WALLS
4 EXISTING GLASS BLOCK WINDOW TO REMAIN,
PROTECT (TYP.)
5 EXISTING METAL PARAPET FLASHING TO REMAIN
(UNPAINTED)
6 NEW PREFINISHED CORRUGATED METAL ROOF
PANEL (BID OPTION #1); SEE CLARIFICATIONS IN
GENERAL NOTE #3
7 NEW PREFINISHED METAL GUTTER (BID OPTION #1)
8 NEW 3" X 3" PREFINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK, SURFACE
DISCHARGE (BID OPTION #1)
9 NEW STEEL BEAM, PAINTED; SEE STRUCTURAL (BID
OPTION #1)
10 EXISTING WALL OPENING (TYP.)
11 NEW PREFINISHED METAL WALL FLASHING (BID
OPTION #1)
12 NEW EXHAUST FLUES; SEE PLUMBING
Top of CMU 18'-8"
01.5-Mezzanine 9'-0"
1 2 3 4
01-Floor 0"
Top of CMU 18'-8"
01.5-Mezzanine 9'-0"
7 7
B.O. FASCIA
15'-0"
7/8" GALVANIZED METAL
FURRING @ 12" O.C.
2-1/2" 20 GA GALVANIZED
METAL FASCIA FRAMING @ 16"
O.C.
STEEL BEAM, PAINTED; SEE
STRUCTURAL
ALUMINUM FASCIA PANEL
PREFINISHED, GALVANIZED
CORRUGATED STRUCTURAL
METAL ROOF DECK; SEE
CLARIFICATIONS IN GENERAL
NOTE #1
STEEL FRAMING, PAINTED;
SEE STRUCTURAL
HE
IG
HT
V
AR
IE
S
PREFINISHED GASKETED
FASTENERS @ 12" O.C.
3/8" DIAMETER WEEP HOLES @
12" O.C. IN WALL TRACK
CONTINUOUS 2" x 2" 16 GA
GALVANIZED STEEL
ATTACHEMENT ANGLE
FASTENED @ 12" O.C.
PREFINISHED METAL
FASCIA TRIM
EDGE OF CMU WALL BEYOND
CONTINUOUS 2" x 2" 16
GA GALVANIZED STEEL
ATTACHEMENT ANGLE
FASTENED @ 12" O.C.
PREFINISHED GASKETED
FASTENERS @ 12" O.C.
1. THE PREFINISHED, GALVANIZED CORRUGATED METAL
ROOFING IDENTIFIED IN BID OPTION #1 DIFFERS FROM THE
HURLBURT BASE STANDARD STANDING SEAM METAL ROOFING
INCLUDED IN THE PROJECT SPECIFICATIONS, BUT HAS BEEN PRE-
APPROVED. THE BASIS OF DESIGN PRODUCT FOR USE IS
BERRIDGE “DEEP-DECK”, 24 GAGE PANEL WITH 1.5 INCH HIGH
PANEL PROFILE. AN APPROVED EQUAL PRODUCT MEETING THE
PERFORMANCE REQUIREMENTS OF THIS SPECIFIC PANEL,
INCLUDING WIND LOAD REQUIREMENTS INDICATED ON THE
DRAWINGS, IS ACCEPTABLE.
2. SEE ENVIRONMENTAL NOTES ON G2 FOR LEAD BASED PAINT
CONCERNS.
G E N E R A L N O T E S
I A
R
E
OF
RC
SP
EC
IA
AN
N P
ER
L O
AT
IO
M M
SC
O
D
DESIGNED BY:
A
IR
F O
R C
E
SP
EC
IA
L O
PE
R
A
TI
O N
S C
O M
M A
N D
DATE:
DRAWN BY:
BUILDING NO:
PROJECT NO:
SHEET REF:
SHEET NO:
AP
PR
OV
ED
CH
IE
F
EN
GI
NE
ER
AP
PR
OV
ED
CI
VI
L E
NG
IN
EE
R
RE
V
DA
TE
DE
SC
RI
PT
IO
N
AP
P'D
S
P E
C
IA
L O
P E
R A
T
IO
N S
E N
G
IN
E E
R S
Q U
A D
R O
N H
U R
LB
U
R T
FI
EL
D , F
LO
R
ID
A
ST
AN
DA
RD
D
LA
YO
UT
(2 4"
X
SE
C
TI
O
N S
A6
RE
N
O
VA
TE
R
HS
W
A
SH
R A
C K
BU
IL
DI
N
G
FTEV 09-1033
AMT
MF
02 MAR 2015
1/4" = 1'-0"A1 A6
1 SECTION
1/4" = 1'-0"A1 A6
2 SECTION
0'2'4' 4' 8'
0'2'4' 4' 8'
K E Y N O T E S
1 PREPARE AND PAINT PREVIOUSLY PAINTED METAL
FASCIA PANELS
2 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
TUBE RAILING SYSTEM
3 REMOVE EXISTING A/C UNIT IN PREPARATION FOR
INSTALLATION OF NEW UNIT BY OTHERS (N.I.C.)
4 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
BAR JOISTS, TYP.
5 PREPARE AND PAINT PREVIOUSLY PAINTED STEEL
LADDER
6 PREPARE AND PAINT PREVIOUSLY PAINTED
GALVANIZED STEEL DECK
7 PREPARE AND PAINT PREVIOUSLY PAINTED SPLIT
FACE CMU WALLS
8 PREPARE AND PAINT PREVIOUSLY PAINTED
ELEVATED PLATFORM STRUCTURE WITH STAIRS
9 NEW TRENCH DRAIN SET IN CONCRETE; SEE CIVIL
AND PLUMBING
10 REPAIR MINOR SETTLEMENT CRACKS IN JOINTS,
TYP.
3" = 1'-0"A4 A6
3 CANOPY FASCIA DETAIL (BID OPTION #1)
FLOORS
SC SEALED CONCRETE
CONC CONCRETE
EX-CONC EXISTING CONCRETE
SG STEEL GRATE
WALLS
EX-CMU EXISTING PREVIOUSLY PAINTED CMU (SPLIT
FACE FINISH ON EXTERIOR WALLS)
EX-MFP EXISTING PREVIOUSLY PAINTED GALVANIZED
METAL FASCIA PANELS WITH EXPOSED
FRAMING
CEILING
EX-GMD EXISTING GALVANIZED METAL DECK
GMD PREFINISHED, GALVANIZED CORRUGATED
STRUCTURAL METAL ROOF DECK
A B B R E V I A T I O N S
F I N I S H I N D E X
FLOORS
CONCRETE
SC CONCRETE FLOOR SEALER
SOLVENT-BASED, CLEAR
WALLS
CMU, SMOOTH AND SPLIT-FACE
P-1 ACRYLIC LATEX, FLAT FINISH
COLOR: BASE STANDARD “LIGHT TAN”
FASCIA PANELS AND RELATED FRAMING
P-2 ACRYLIC LATEX, SEMI-GLOSS
COLOR: BASE STANDARD “LIGHT TAN”
CEILING
GALVANIZED METAL DECK
P-2 ACRYLIC LATEX, SEMI-GLOSS
COLOR: BASE STANDARD “LIGHT TAN”
STEEL FRAMING, INCLUDING BAR JOISTS
P-3 HIGH PERFORMANCE PAINT SYSTEM
CONSISTING OF ZINC RICH PRIMER,
EPOXY INTERMEDIATE COAT AND
FLOROPOLYMER POLYURETHANE
TOPCOAT, SEMI-GLOSS FINISH
COLOR: BASE STANDARD “LIGHT TAN”
DOORS
GALVANIZED METAL DOOR
P-4 ACRYLIC LATEX, SEMI-GLOSS
COLOR: BASE STANDARD “DARK BRONZE”
HOLLOW METAL DOOR FRAME
P-5 HIGH PERFORMANCE PAINT SYSTEM
CONSISTING OF ZINC RICH PRIMER,
EPOXY INTERMEDIATE COAT AND
FLOROPOLYMER POLYURETHANE
TOPCOAT, SEMI-GLOSS FINISH
COLOR: BASE STANDARD “DARK BRONZE”
STEEL ACCESSORIES, INCL. PLATFORM, STAIRS, LADDER, RAILINGS
P-3 HIGH PERFORMANCE PAINT SYSTEM
CONSISTING OF ZINC RICH PRIMER,
EPOXY INTERMEDIATE COAT AND
FLOROPOLYMER POLYURETHANE
TOPCOAT, SEMI-GLOSS FINISH
COLOR: BASE STANDARD “LIGHT TAN”
PREFINISHED METAL COMPONENTS (BID OPTION #1)
1. PREFINISHED, GALVANIZED CORRUGATED…
This is the start of the file's text. The full file is on GovTribe.