This document is an attachment titled "Salient Characteristics" that provides specifications for a Hydraulic Compression Press being procured under Solicitation Number FA460824QC137. The press must have a 0.5 to 3 ton compression force, a 30" L-R x 30" F-B work area, a 48" open daylight, a 3.25" bore hydraulic clamp cylinder with a 24" stroke, and a 6.5" lower platen operating height. The hydraulic system must be self-contained with a 15-gallon reservoir, dual gear pump, and water-cooled heat exchanger. The control system must include an Allen Bradley MicroLogix 1400 programmable controller, operating buttons, and indicating lights. This procurement is a total small business set-aside with a size standard of 500 employees. Quotes are due by 12:00 PM CDT on Monday, July 29, 2024.

View the file

Other files

File Type Posted
Combined Synopsis Solicitation FA460824QC137.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA460824QC137

Attachment 2

Salient Characteristics

CLAMP SPECIFICATIONS

• Down-acting Cylinder

• .5 - 3 ton compression force (adjustable)

• 30” L-R x 30” F-B work area

• Single opening with:

o 48” open daylight

• 3.25“ bore hydraulic clamp cylinder

• 24” stroke

• 6.5” lower platen operating height (approximate)

• Built-in lift truck tubes

HYDRAULIC SYSTEM

• Self-contained hydraulic system, including:

o 15-gallon reservoir with access panel and gauge for oil level and temperature indication o Dual gear pump system with energy-efficient TEFC motor o Water-cooled heat exchanger

CONTROL SYSTEM

• NEMA-rated electrical control enclosure, including:

o Allen Bradley MicroLogix 1400 programmable controller o Operating buttons, including two-hand “anti-tie-down” circuit for cycle initiation o Indicating lights

• 120/1/60 supply voltage

• Non-fused disconnect