This document is an attachment titled "Salient Characteristics" that provides specifications for a Hydraulic Compression Press being procured under Solicitation Number FA460824QC137. The press must have a 0.5 to 3 ton compression force, a 30" L-R x 30" F-B work area, a 48" open daylight, a 3.25" bore hydraulic clamp cylinder with a 24" stroke, and a 6.5" lower platen operating height. The hydraulic system must be self-contained with a 15-gallon reservoir, dual gear pump, and water-cooled heat exchanger. The control system must include an Allen Bradley MicroLogix 1400 programmable controller, operating buttons, and indicating lights. This procurement is a total small business set-aside with a size standard of 500 employees. Quotes are due by 12:00 PM CDT on Monday, July 29, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation FA460824QC137.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA460824QC137
Attachment 2
Salient Characteristics
CLAMP SPECIFICATIONS
• Down-acting Cylinder
• .5 - 3 ton compression force (adjustable)
• 30” L-R x 30” F-B work area
• Single opening with:
o 48” open daylight
• 3.25“ bore hydraulic clamp cylinder
• 24” stroke
• 6.5” lower platen operating height (approximate)
• Built-in lift truck tubes
HYDRAULIC SYSTEM
• Self-contained hydraulic system, including:
o 15-gallon reservoir with access panel and gauge for oil level and temperature indication o Dual gear pump system with energy-efficient TEFC motor o Water-cooled heat exchanger
CONTROL SYSTEM
• NEMA-rated electrical control enclosure, including:
o Allen Bradley MicroLogix 1400 programmable controller o Operating buttons, including two-hand “anti-tie-down” circuit for cycle initiation o Indicating lights
• 120/1/60 supply voltage
• Non-fused disconnect