Presolicitation Notice: FA301621R0022
This notice is posted in accordance with FAR 5.2.
This RESTRICTED ACQUISITION is set-aside for WOSB Small Businesses, prior to the closing date of the solicitation.
The NAICS code is 236220 and the Size Standard is $39.5M.
In accordance with FAR 4.1102 and DFARS 252.204-7004, Alternate A, System for Award Management
(SAM), contractor must be registered in SAM prior to award. Offerors may obtain information on registration at https://www.sam.gov.
SOLICITATION NUMBER: FA301621R0022
The contractor shall provide design and construction services to modify R6103 B3260 at JBSA - Ft Sam
Houston for the installation of an IPG Photonic Laser Model YLS-50000.2lll.
The Contractor shall modify R6103 as follows:
- seal existing 4" communication conduit into anechoic chamber. Bore and install an 8" PVC communication conduit in location specified by 711 HPW/OMT.
- provide an area covering the back right corner of the anechoic chamber (looking in from the door) that extends 3-ft on each side of the corner and a second section that covers 4 linear feet that can slide to any position along the 20-ft wall of the chamber, with the bottom resting on/supported by floor.
- provide Fine Grain Extruded Graphite plates, Grade GR060, by Graphtec LLC (or equal; comparable grades are CBY or G11). Plates to be 1" thick by 12" wide by 72" long/tall. Install plate's vertical (12" wide by 72" tall), 3 plates on left side of corner and 7 plates on the right side. Manufacture a frame to hold the panels that allows the ability to slide graphite plates right/left for future removal and replacement as necessary. Verify location with 802d CES project manager prior to securing.
- provide cement backer board on the interior anechoic chamber walls (except on ceiling).Replace any ceiling tiles affected by work completed within scope. Match existing ceiling tiles in the room. Install
Government provided IPG Photonics remote Air/Water model LC 340.01-A.3.6, 460V, 60Hz along exterior of facility.
- construct a chiller pad enclosure 4" concrete equipment pad, 3000 psi minimum, along south wall of facility where the enclosure shall be constructed of cinder block with a brick veneer finish to match existing. See concept drawings shown as attachments.
- install chillers on pad as per manufacturer's specifications. Refer to manufacturer's Pre-Installation
Guide and Operating Manual (attached to this SOW).
- provide netting at the top of the chiller enclosure preventing birds from netting and anti-rodent solution to prevent infestation.
- follow UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings, Section 3-3, Standard 2, and
Unobstructed Space, if directed by 802nd CES.
- install Government supplied IPG Photonics Laser Model YLS-50000 and Collimator in R6103. Refer to manufacturer's Pre-Installation Guide and Operating Manual (attached to this SOW).
- install IPG Collimator. Refer to manufacturer's Pre-Installation Guide and Operating Manual (attached to this SOW).
https://www.sam.gov/
- connect chilled water supply/return lines between (3) chillers to laser and collimator. Provide all piping, piping insulation, connections, appropriate water and chemicals as specified by laser manufacturer for chilled water loop. Provide pass through of appropriate size through exterior of facility and into anechoic chamber wall for chilled water supply/return water loop.
The Contractor shall modify HVAC as follows:
- provide and install two (2) articulating snorkel exhaust arms inside the anechoic chamber. Snorkel shall be of appropriate length and articulations (minimum 2 points) for suction end to reach entire surface area of graphite walls and at least 12 feet from graphite walls. Snorkel shall have appropriate aperture size, exhaust velocity, and filtration required to capture all chemicals/off gases. A pre-filter over aperture to protect snorkel is also required. Contact 802nd Bio-Environmental for additional guidelines.
- snorkel securely to ceiling and/or chamber wall per location specified. Verify the system conforms to appropriate occupational health standards, such as the recommendations of the American Conference of Governmental Industrial Hygienists, Association of Operating Room Nurses, American Society for
Laser Medicine and Surgery, Emergency Care Research Institute, or National Institute for Occupational
Safety and Health.
- provide on/off switch on chamber entrance wall for exterior exhaust. v. disconnect existing chamber exhaust from building manifold return. Combine snorkel and chamber exhaust and provide dedicated exhaust to facility exterior.
- confirm plume rise of exhaust meets environmental standards.
- construct a build in filtration system to meet environmental standards.
The Contractor shall modify electrical system as follows:
- provide new MCB panel board in R6103 for laser system power.
- feed new panel board from main electrical vault.
- provide surge protection for new panel board.
- CB shall have shunt trip and be connected to existing room EPO.
- provide new circuit breakers and disconnects for the laser system and all ancillary equipment.
- provide all conduit, fittings, and conductors required to provide power to new panel board and new equipment.
- provide clear lift cover over EPO.
There are no modifications to the fire protection system.
The location of the work will be on JBSA - Ft Sam Houston, TX.
The 502d Contracting Squadron intends to award a contract with a 120 calendar day period of performance.
The estimated magnitude of the entire contract IAW FAR 36.204(f) is between $500K and $1M.
NOTES:
1. The solicitation with official specification will be available on or about 29 Mar 2021, at http://beta.sam.gov, the tentative date for receipt of proposals is 29 Apr 2021. The period of performance is 120 calendar days.
2. Hard copies of the solicitation will not be provided. You may; however, download and print the file from the website http://beta.sam.gov.
3. Contractors shall be capable of securing bonding for the total proposed amount.
4. Contractors that are Debarred, Suspended, or Proposed for Debarment are excluded from receiving contracts. Agencies also shall not consent to subcontract with these contractors.
5. The Government reserves the right to cancel this solicitation, either before or after the closing date. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs.
6. The current status is Pre-Solicitation and its PSC code is: Z2JZ – Repair or Alteration of Miscellaneous Buildings.
7. The points of contact for this requirement are:
Contracting Officer Contract Specialist
Todd Martinez Robert Gallegos
210-671-7461 210-671-7461
1655 Selfridge Ave, Bldg 5450 1655 Selfridge Ave, Bldg 5450
San Antonio, TX 78236 San Antonio, TX 78236 todd.martinez.1@us.af.mil robert.gallegos.4@us.af.mil http://beta.sam.gov/ http://beta.sam.gov/ mailto:todd.martinez.1@us.af.mil mailto:robert.gallegos.4@us.af.mil
File details come from the government source that posted it. Updated .