Attachment_2_Statement_of_Work.pdf

PDF 76 KB Posted

Attached to
Dielectric/Load Testing, Digger Truck Federal contract opportunity
Solicitation number
FA2823-19-Q-4020
Issued by
Department of the Air Force Materiel Command Test Center

About this file

Attachment 2 Statement of Work

View the file

Other files for this federal contract opportunity

Other files attached to Dielectric/Load Testing, Digger Truck, newest first.
File Type Posted
FA2823-19-Q-4020_Combo__Modified.pdf PDF
Dielectric_Load_Testing_Q__A.pdf PDF
Attachment_3_Wage_Determination.pdf PDF
FA2823-19-Q-4020_Combo.pdf PDF
Attachment_1_Provision_and_Clauses.pdf PDF
Attachment_2_Statement_of_Work.pdf PDF
Attachment_1_Provision_and_Clauses.pdf PDF
FA2823-19-Q-4020_Combo.pdf PDF
Attachment_3_Wage_Determination.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK FOR BUCKET TRUCK AND HOT STICK TEST AND INSPECTION

Bucket Truck Testing and Inspections

The contractor shall perform the following services once a year on five (5) bucket trucks dielectric test as per ANSI A92.2 2009 and manufactures name plate includes Test of High Resistance Upper Controls, Insulated upper boom, Chasse (lower boom) Insulator, and bucket liner.

The bucket truck unit Inspection IAW ANSI A92.2 2009 and manufactures manual, includes removal of all inspection covers and visual checking all hydraulic hoes, hydraulic fittings, cables, insulating fiber rods, sheaves, cylinders, replacing inspection covers, Vacuum Test Atmosphere Vents, and providing us with a type written report and pictures.

The elevator unit inspection shall be IAW ANSI A92.2 2009 (Example 98’/65’, 105/70’,) and any unit over 90’ in platform.

Digger Derrick Truck Testing and Inspections

The contractor shall perform the following services once a year on three (3) digger trucks; Test as IAW ANSI A10.31 and manufactures name plate, includes removing of winch line from insulating section of unit boom, testing of insulted boom, install winch line back across boom tip sheave.

Digger Derrick Truck inspection shall be done IAW ANSI A10.31 and ASME – B320.5 and manufactures manual, includes removal of inspection covers and visual checking all hydraulic hoses, hydraulic fittings, cables, insulating fiber rods, sheaves, cylinders, critical welds, replacing inspection covers, and providing you with a type written report and pictures.

Hot Stick tests

The contractor shall perform the cleaning, waxing and testing on extendable/non extendable on ten (10) hot sticks and ten (10) switch sticks. @100KV /Ft for 5 mins.