Technical Requirements
SUBJECT: Government Technical Requirement Document: FLIR A6753sc brand name or equivalent MWIR and LWIR cameras
1. A requirement for a Commercial Off The Shelf (COTS) Midwave Infrared (MWIR) camera.
The camera must meet the following technical requirements.
a. The camera detector type must be Indium Antimonide (lnSb)
b. The camera must have a cold filter to limit the spectral range to 3.0 - 5.0 µm
c. The camera detector pitch must be III5 µm
d. The camera resolution must be 640 x 512
e. The camera must have a noise equivalent temperature difference (NETO) < 20 mK
f. The camera must have a frame rate > 120 Hz at full window
g. The camera must have an adjustable integration time
h. The camera must have a Gigabit Ethernet (GigE) output and be GigE Vision 2.0 compliant.
i. The camera must have a dynamic range 14 bits
j. The camera must include four (4) lenses.with an equivalent focal length (EFL) of
i. 13 mm
ii. 25 mm
iii. 100 mm
k. The camera must include a factory calibration from -20 to 350 °C for each lens.
I. The camera system must include a power supply
m. The camera system must include software to record calibrated camera movies
n. The camera system must include software for camera control features such as adjusting integration time and frame rate
o. The camera system must include an operation manual
p. The camera system must be delivered a Pelican style case
2. The has a requirement for a COTS Longwave Infrared (L WIR) camera. The camera must meet the following technical requirements.
a. The camera detector type must be Type II InAs/(In)GaSb Strained Layer Superlattice
(SLS) technology
b. The camera must have a cold filter to limit the spectral range to the longwave infrared, approximately 6.0 - 14.0 μm
c. The camera detector pitch must be 15 μm
d. The camera resolution must be 640 x 512
e. The camera must have a noise equivalent temperature difference (NETO) < 30 mK
f. The camera must have a frame rate > 120 Hz at full window
g. The camera must have an adjustable integration time
h. The camera must have a Gigabit Ethernet (GigE) output and be GigE Vision 2.0 compliant.
i. The camera must have a dynamic range ~ 14 bits
j. The camera must include four (4) lenses with an equivalent focal length (EFL) of
i. 13 mm
ii. 25 mm
iii. 100 mm
k. The camera must include a factory calibration from -20 to 650 °C for each lens.
l. The camera system must include a power supply
m. The camera system must include software to record calibrated camera movies
n. The camera system must include software for camera control features such as adjusting integration time and frame rate
o. The camera system must include an operation manual
p. The camera system must be delivered a Pelican style case