This Statement of Objectives (SOO) outlines requirements for resurfacing flooring at the Fire Emergency Services facility at Buckley Space Force Base, with work to begin January 1, 2025. The project involves two main areas: a 975-square-foot garage/weightroom and a 5,995-square-foot Main Apparatus Bay. The related Sources Sought notice from the 460th Contracting Squadron seeks vendor responses by 4 PM MST on January 27, 2025.
The SOO specifies detailed flooring requirements including resistance to diesel fuel, hydraulic fluid, and hot tire pickup from 20+ ton fire trucks. The Main Apparatus Bay requires a double broadcast quartz system with 100% solid epoxy base/intermediate coats and gray polyaspartic final coating, plus safety red parking lines for 10 truck spaces (to be completed in 2 phases). The garage/weightroom area requires a decorative flake commercial grade system in black, white, gray and red with clear topcoat and silica for slip resistance, including installation of a Fire Department logo. Work must be completed within 120 days of order receipt during normal business hours (7AM-4PM Monday-Friday), and contractors must pass background checks for base access. Responses should be emailed to the provided Space Force contracting officers with company details including CAGE code and UEI number.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF OBJECTIVES
Complete resurfacing of Apparatus Bay Buckley Space Force Base (BSFB) CO 80011 1 January 2025
1. SCOPE:
The 460th Civil Engineering Squadron (CES) Fire Emergency Services has a requirement to complete new flooring scheme for their Apparatus Bay and garage/weightroom and other concrete surfaces.
2. REQUIRMENT:
Flooring consists of two areas. Area one of approximately 975 square feet (specification in Section D.) the garage/weightroom and area two Main Apparatus Bay floor is approximately 5995 square feet (specifications in Section B).
3. SPECIFICATIONS:
A. Floor coating scheme must be able to resist exposure to diesel fuel, hydraulic fluid, transmission fluid, and brake fluid. Main Apparatus Bay must not be susceptible to hot tire pickup from the fire trucks (apparatus), which weigh more than twenty tons. Paint must not bubble and lift wherever the tires come to rest in the bays leaving spots on the floor with bare concrete showing.
B. Floor coating scheme must be impact, wear, scratch, and abrasion resistant. Must be slip resistant even when wet and easy to clean and maintain. Profile the concrete with a combination of shotblasting and grinding all surfaces, creating a uniformed surface profile. Contractor must remove, repair, fill all control joints (coated to match floor) and repair and fill all concrete spalled areas. For Main Apparatus Bay the contractor must apply a double broadcast quarts system 100% sold epoxy for the base and intermediate coats followed by a grout coat tinted gray and an additional final coat also gray of high solid polyaspartic.
C. Main Apparatus Bay floor has painted back-up parking lines that will need to be installed. Once floor has cured mark out the parking lines for each vehicle parking area, sand area where lines will be installed prior to applying polyaspartic tinted safety red for the demarcation of those lines. Lay out the lines as the same manner as the current lines unless otherwise specified by FD prior to line installation.
Note: A total of 10 truck parking areas, the job will be split in half (2 phases), the contractor will only perform work on 5 truck parking areas at each phase of work.
D. In the garage, weightroom area and the Main Apparatus Bay along the south wall including the doorways and foundation wall on the south wall, and all platformed concrete north and south areas in the engine storage room (referred to as area one). A deco flake floor coating will need to be applied to create a more pleasant aesthetic and hide minor dirt, dust and debris. A full flake commercial grade system of black, white, gray and red and clear topcoat with silica to increase slip resistance of the finished floor must be applied. Contractor will lay a 36” x 42” Fire Department decal logo in the entrance from the main entrance area to the apparatus bay area. The Fire Department will supply the decal logo. The logo will be installed before final clear topcoat goes over the top of the full flake commercial grade system.
E. Contractor will do work during normal work hours 7AM-4PM Monday-Friday excluding Federal Holidays. Contractor will provide their own equipment, tools, materials, power and restrooms.
4. DELIVERY:
The contractor shall deliver/install floor covering scheme that meet the above requirements no more than 120 days after receipt of the order. Delivery address will be provided upon award. The Technician completing the install will be required to be able to pass a background check to enter BSFB. Items, when delivered, will be accepted and inspected by the government officials responsible for receiving the products and performing any required inspections. The quotes received assumes work to complete flooring is done during normal business hours during the negotiated maintenance window and in association with apparatus flooring project.
Main Apparatus Bay Quartz Floor This type of floor has colored sand media in the epoxy and is an aesthetically appealing floor. Used for commercial situations where there is heavy foot and/or vehicle traffic. It's approx. 1/8" thick and is typically done with a polyaspartic topcoat.
Install: Double broadcast quarts system 100% sold epoxy for the base and intermediate coats followed by a grout coat tinted gray and an additional final coat also gray of high solid polyaspartic.
Main Apparatus Backup Lines Painted back-up parking lines sand area where lines will be installed prior to applying polyaspartic tinted safety red for the demarcation of those lines.
Garage/Weightroom (some areas of main apparatus bay) A deco flake floor coating: A full flake commercial grade system of black, white, gray and red and clear topcoat with silica to increase slip resistance of the finished floor must be applied