This document is a Request for Quote (RFQ) Notice for a fiber cable material and installation contract opportunity. The U.S. Air Force 460th Contracting Squadron at Buckley Space Force Base, CO is seeking a contractor to provide fiber cables and installation to establish a direct connection path for Standard Space Trainer (SST) workstations in Building 442 to the SST server in Building 447. The contractor must deliver the required fiber cabling and installation within 90 days after receipt of the order. Responses to the RFQ, including a statement of work, quote, warranty details, and company information, are due by 10:00 AM MDT on Monday, September 16, 2024. Questions from interested vendors are due by 10:00 AM MDT on Tuesday, September 10, 2024. The Performance Work Statement outlines the specific requirements for the fiber cable material and installation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SESAMI SST Fiber Cable Path & Room Layouts

Space Delta 4 Videmus Mundum

Bldg. 447 East Side Fiber Path

Run 36-strand single-mode fiber cable from Bldg. 447 Room S123 (IST Comm) through Room 030 (Core Node) to Bldg. 442, Room 510 (OBAC Equipment Room) Cable passes through Room 030, does not terminate in Room 030 Terminate in Bldg. 447, Room S123 to IST Cab 1, Patch Panel 2 (new patch panel needed at U40 of rack) using LC connections Terminate other end of cable at Bldg. 442, Room 510 to Rack 01B, U1 using LC connections Run 16-strand single-mode fiber cable from Bldg. 447, Room S123, to Bldg. 447, Room S122 (SST Server) Terminate in Room S123 to IST Cab 1, Patch Panel 2 using LC connections Terminate in Room S122 to SST Cab 8 using LC connections

Bldg. 447 West Side Fiber Path

Run 36-strand single-mode fiber cable from Bldg. 447 Room S123 (IST Comm) through Room 030 (Core Node) to Bldg. 442, Room 510 (OBAC Equipment Room) Cable passes through Room 030, does not terminate in Room 030 Runs through Protected Distribution System (PDS) conduit

Bldg. 442 SESAMI SST Fiber Path

From Bldg. 447 36-strand (18-pair) single-mode fiber cable ran from Bldg. 447, Room S123 (IST Comm) direct to Bldg. 442, Room 510 Annotated by red lines Runs through PDS conduit from facility exterior to Room 271 Opens into cable trays in Room 271 2-strand (1-pair) single-mode fiber cable ran from Bldg. 442, Room 510 (Rack 1B) direct to Bldg. 442, Room 300 (Rack 5164) Annotated by blue lines

Rack 5164

Bldg. 447 Room S122

PDS Conduit from Room S123 entry point into Room S122

16-strand fiber cable termination point (Rack 8)

Bldg. 447 Room S123

16-strand fiber cable termination point (S123 to S122 cable connection) PDS Conduit from Room S122 entry point into Room S123 36-strand fiber cable termination point (S123 to Bldg. 442 Room 510 cable connection) PDS Conduit from Room 030 entry point into Room S123

Bldg. 447 Room 030

PDS Conduit from Room S123 junction point into Room 030