23B0003 (DBEH 22-1580) Site Visit Roster.pdf

PDF 230 KB Posted

Attached to
DBEH 22-1580 Replace HVAC Controls Federal contract opportunity
Solicitation number
FA252123B0003
Issued by
Department of the Air Force Space Command

About this file

This solicitation is for a firm fixed price construction contract to replace HVAC controls at five facilities located at Cape Canaveral Space Force Station and Jonathan Dickinson Missile Tracking Annex in Florida. The work includes providing labor, equipment, and materials to replace HVAC controls with new automation servers, integrating them to the existing EMCS server, and providing graphical user interface screens, data logs, and alarms. The magnitude of construction is estimated between $500,000 and $1,000,000. This acquisition is being issued as a competitive set-aside for Service-Disabled Veteran-Owned Small Businesses. Funds are not presently available and any contract award would be contingent upon appropriation of funds. The solicitation number is FA252123B0003 and is issued by the Department of the Air Force Space Command.

View the file

Other files for this federal contract opportunity

Other files attached to DBEH 22-1580 Replace HVAC Controls, newest first.
File Type Posted
FA252123B0003 SF 1409 Abstract.pdf PDF
FA252123B0003 A003.pdf PDF
FA252123B0003 A003.pdf PDF
Attachment 26 WD FL20230001 (20230602).pdf PDF
FA252123B0003 A002.pdf PDF
Attachment 21 As Built DWG Facility 1428 CCSFS (Replace HVAC Fire Protection Elec Dist).pdf PDF
Attachment 23 As Built DWG Facility 55899 CCSFS (SOSF).pdf PDF
Attachment 24 Estimated Quantity of Devices.pdf PDF
Attachment 20 QA Government Responses.pdf PDF
Attachment 22 As Built DWG Facility 1606 CCSFS (OEM).pdf PDF
FA252123B0003 A0001.pdf PDF
Attachment 25 WD FL20230001 (202305015).pdf PDF
Attachment 11 JDMTA As-Built Control Drawing 1.jpg JPG image
Attachment 17 JDMTA As-Built Control Drawing 7.jpg JPG image
Attachment 18 JDMTA As-Built Control Drawing 8.jpg JPG image
Attachment 4 GPP Certification (DBEH 22-1580).pdf PDF
Attachment 6 CECC Form 3052.xlsx XLSX spreadsheet
Attachment 7 QA Template.docx DOCX document
Attachment 8 Site Visit Rules.pdf PDF
Attachment 12 JDMTA As-Built Control Drawing 2.jpg JPG image
Attachment 19 Drawing 98K00034 (19990820).pdf PDF
FA252123B0003 (DBEH 22-1580).pdf PDF
Attachment 2 WD FL20230001.pdf PDF
Attachment 3 WD FL20230214.pdf PDF
Attachment 10 Answers to Questions from 22B0011.pdf PDF
Attachment 16 JDMTA As-Built Control Drawing 6.jpg JPG image
Attachment 1 SOW DBEH 22-1580 (20230313 (Rev 3)).pdf PDF
Attachment 5 Contractor Hazardous Waste Form.docx DOCX document
Attachment 9 Badge Request Form.pdf PDF
Attachment 13 JDMTA As-Built Control Drawing 3.jpg JPG image
Attachment 14 JDMTA As-Built Control Drawing 4.jpg JPG image
Attachment 15 JDMTA As-Built Control Drawing 5.jpg JPG image
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .