F3YCFA4072AC04 - Questions and Answers.pdf
PDF 90 KB Posted
- Attached to
- 38 CEIG Nellis Network Switches
- Solicitation number
- F3YCFA4072AC04
About this file
This document is a set of Questions and Answers related to a Request for Quotation (RFQ) for 38 Network Switches and Peripherals for Nellis Air Force Base. The solicitation number is F3YCFA4072AC04.
The key details are: the products must be brand new, not refurbished; there are no specific part numbers for the required patch cables, which can be another brand as long as they meet the specified parameters; the contract type will be Firm Fixed Price; the anticipated delivery is 90 days ARO to Nellis AFB, NV; the North American Industry Classification System (NAICS) code is 334111 with a small business size standard of 1,250 employees, and this is a Total Small Business Set-Aside requirement. Questions must be submitted by Monday, 22 April 2024, and quotes are due on Tuesday, 30 April 2024. The contract will be awarded to the lowest-priced, technically acceptable vendor. This is a new contract, with no incumbent.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ques�ons & Answer: F3YCFA4072AC04 - 38 CEIG Nellis Network Switches
1. I was wondering if the products being solicited have to be brand new or if they are able to be refurbished goods?
A: The products being solicited must be brand new.
2. Our Technical team is having trouble with CLIN 007 and 008. Would you know the MFR. name by chance? We're not finding anything with the listed Part # and Part Descrip�on.
A: There are no specific part numbers for patch cables. CLIN 7: 2M OM3 LC LC Duplex
Fiber Patch Cable, 2 mm Green Jacket (Must be TAA Compliant). CLIN 8: 3M OS2 Singlemode LC LC Fiber Patch Cables, 2 mm Green Jacket (Must be TAA Compliant)
3. This requirement is just to furnish the 8 CLINs in the quan�ty specified right? The only items that can be outside of the CISCO brand are the ones that say or Compa�ble with Cisco Systems listed in CLIN 0001- CLIN 0006.
A: Yes CLIN’s 007 and 008 are the only ones that can be another brand as long as they meet the parameters in the Part Descrip�on
4. Regarding CLIN 007 and 008 in items requested, does the cable jacket have to be PVC? Would Plenum be acceptable? Thanks for your help on this clarifica�on.
A: Yes has to be PVC cannot be plenum rated.
5. We would like to know if this is a brand new contract OR if there is (was) an incumbent performing these services.
A: This is a brand new contract.
File details come from the government source that posted it. Updated .