This document is a Questions and Answers file related to a Request for Quotation (RFQ) for the procurement of two low pressure air compressors for installation at Nellis Air Force Base in Nevada. The RFQ solicitation number is F3G2CA4194A001, and it is set aside for small businesses under NAICS code 333912. The anticipated contract type is Firm Fixed Price, and the compressors must be delivered within 5 weeks of contract award. The government requires the compressors to provide 100-125 PSI of output pressure and be able to operate in ambient temperatures up to 125°F. The contractor will be responsible for installation and initial startup of the compressors on a concrete pad at the base. Quotes are due by August 23, 2024, and the government will award a single contract to the lowest-priced, technically acceptable offer.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F3G2CA4194A001 - 57 MUNS Pad Compressor Questions & Answers

1. Does the requirement need a Rotary screw or Piston type air compressor?

Answer will be provided shortly.

2. Elevation above sea level where the compressor will operate (city or region)

- Nellis elevation is 1869FT above sea level

3. Inlet pressure

- Unknown for inlet. Output needs to be 100-125PSI

4. Max ambient temperature

- 125F

5. Will this unit be susceptible to all ambient conditions – extreme heat, rain, potential cold, blazing sun? The sun, rain and possible cold will be an issue.

- Since these are outdoor units with no structure surrounding it, they will be exposed to all the elements constantly.

6. Please state the min and max ambient temperatures that these units will see.

- Lowest is approx. 30F. highest is Approx 125F

7. What vehicle are you planning to have this installed on, and are you planning to bring it to vendor’s shop if the quote is approved?

- This is planned to be installed on a concrete pad.

- Do not plan on bringing to vendor’s shop. Will request a site visit if needed in the future

8. Who is responsible for installing power for the equipment and from where?

- “Lira Electric” is the preferred company to install power if required, but the preferred electrical power method is to use existing outlets.

-This is not the required source.

9. Will the owner have the power run to a certain point or will we (the contractor) need to run power from the main MCC over to the equipment?

- The contractor will be requested

10. Is this job tax exempt? If so, will a tax exempt certificate be provided once awarded?

- No

11. Is this job Net30?

- Yes

12. Will power be provided/ what power will be provided?

- 460 Hz / 3 phase 60 Hz power can be provided

13. Will there be running air lines/ air pipes?

- A flexible air hose will be used to power a pneumatic hoist

14. What is the amperage outlet provided at the outlet?

Answer will be provided shortly.

15. What is the size of the breaker & wire size?

Answer will be provided shortly.

16. Does the current compressor have any issues?

- There are no current compressors. New compressors are needed

17. Are there any moisture issues?

- No

18. Will air compressors be mounted to the pad?

- It is desired to not have the compressor mounted to the pad