Attachment 1
57 KB Posted
- Attached to
- PURCHASE OF WINDOW COVERING INSTALL/REPLACEMENT
- Solicitation number
- F2W4A19013A001
About this file
Revised (Amendment 0001) - Change SOW 2 a) v) from "12 windows" to "24 windows " (highlighted in yellow).
Text of this file
Attachment 1
STATEMENT OF WORK
Window Covering Install/Replacement
Bldg 2040
1) General Requirements:
a) Contractor is responsible for all materials, labor, permits, management oversight, and equipment to accomplish the renovations.
b) The contractor is responsible for the removal of all debris, trash and construction residue to an off base location for proper disposal.
c) Contractor must abide by current NFPA, OSHA, International Building Code, Uniform Building
Code, DOD, US Air Force and Malmstrom AFB requirements.
d) Contractors shall be required to attend a Safety and an Infection Control Briefings prior to start of work. This will be provided by the government and lasts approximately 30 minutes.
e) Contractor must consider the impact their work will have on Patient Care and keep that impact to absolute minimum and will cone off area of work.
f) Work will be completed daily between the hours of 0700-1630, except for weekends and Federal
Holidays as approved in advance by Facility Manager or Administrator.
g) Contractor’s personnel shall; participate in fire drills and all other actual emergencies at the direction of the Facility Manager or the on-scene-commander, wear clinic identification badges at all time while within clinic.
h) Medical Group Facilities are “Zero Tobacco”. Smoking is allowed only in the designated smoking area behind the ambulance garage or private vehicle. Smoking is not allowed within 25 feet of any door.
i) Contractor will provide at no additional cost all appropriate manuals and warranty information for items installed.
j) Contractor will protect flooring from any damage.
k) Contractor will verify all measurements and colors prior to installation
2) Blinds Location and description
a) Lobby (On Attachment 2)
i) Cordless
ii) Match window frames in color
iii) Mounted within window frames
iv) Brand Name or Equal to Kirsch Cellular Shades
(1) Mosaic Collection,
(2) Spunlace Fabric,
(3) 7/16” Cell size,
(4) Semi-Opaque,
(5) 2.7-3.3 R-value,
(6) 50 Ultraviolet Protection Factor (UPF)
v) There are 24 windows with the following approximate dimensions. Contractor is responsible for verifying actual size prior to installation:
(1) 4 ea (34 ½”w x 50 ½” h)
(2) 4 ea (34 ½” x 24” )
(3) 4 ea (42 ½” x 50 ½”)
(4) 4 ea (42 ½ x 24”)
(5) 4 ea (36” x 50 ½”)
(6) 4 ea (36” x 24”)
b) Rooms (TriCARE waiting, Education Conf)
i) With cord
ii) Match color in Optometry
iii) Mounted outside of frame
iv) Brand Name or Equal to Kirsch Cellular Shades
(1) Mosaic Collection,
(2) Spunlace Fabric,
(3) 7/16” Cell size,
(4) Semi-Opaque,
(5) 2.7-3.3 R-value,
(6) 50 Ultraviolet Protection Factor (UPF)
v) Tricare there 3 windows with the following approximate dimensions. Contractor is responsible for verifying actual size prior to installation:
(1) 2 ea (42”w x 66” h)
(2) 1 ea (73 ½” x 86 ½”)
vi) Education there 4 windows with the following approximate dimensions. Contractor is responsible for verifying actual size prior to installation
(1) 1 ea (42”w x 54”h )
(2) 1 ea (84 ½” x 51 ¾”)
(3) 1 ea (84” x 53”)
(4) 1 ea (98 ½” x 82 ½”)
c) Office Blinds (On Attachment 2)
i) With cord
ii) Mounted inside frame when possible
iii) Brand Name or Equal to Kirsch Cellular Shades
(1) Mosaic Collection,
(2) Spunlace Fabric,
(3) 7/16” Cell size,
(4) Semi-Opaque,
(5) 2.7-3.3 R-value,
(6) 50 Ultraviolet Protection Factor (UPF)
iv) List of location and size attached
d) Door Blinds (On Attatchemnet 2)
i) With cord
ii) Mounted on window frame flush with top
iii) Brand Name or Equal to Kirsch Cellular Shades
(1) Mosaic Collection,
(2) Spunlace Fabric,
(3) 7/16” Cell size,
(4) Semi-Opaque,
(5) 2.7-3.3 R-value,
(6) 50 Ultraviolet Protection Factor (UPF)
iv) List of location and size attached
*NOTE: Contractor will verify all measurements and colors prior to installation.
Measurements listed are only for reference.
Other files
| File | Type | Posted |
|---|---|---|
| (SOW)-Attachment 1 .doc | DOC document | |
| (Room Count)-Attachment 2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .