ZIRCAR Insulation Specifications

2 inch thick high strength, high density insulation having a thermal conductivity of 0.12 W/m/K or less, a density of 0.76 g/cc or higher, a compressive strength of 1,000 psi or higher, a coefficient of thermal expansion of 5 x10^-6 per degree C or less, a flexural strength of 600 psi or greater at 5 mil deformation.

Operating temperature ranging from -40F to 200F or greater, screw holding strength @7/8 inch penetration of 200 lbs or greater. Material must be non-flammable, have high electrical resistance, must be non-hazardous once cut, fabricated and installed and must be chemically non-reactive with water, ammonia, oils and acids. QTY: 18 pieces. Mfg P/N: ZIRCAL-45, SS35 (OR EQUAL).