Catheter_single_source_justification_FBO.pdf
PDF 258 KB Posted
- Attached to
- REBOA CATHETERS
- Solicitation number
- F2FF116223AW01
About this file
REBOA CATHETERS
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Single Source Justification (Simplified Acquisition)
Section A: General Contract Information
Contracting Activity: 1 SOCONS Purchase Request/
Identification Number:
Project/Program Name:
Resuscitative Endovascular Balloon Occlusion of the Aorta Catheter
(REBOA)
Item # ER7232A
Estimated Contract Cost
Total =
Section B: Description of the Supplies/Services Required
The need for a flexible catheter inserted through an introducer and into the femoral artery, maneuvering it into the aorta and inflating a balloon at its tip. This technique/ Endovascular Balloon Occlusion of the Aorta Catheter will be used in traumatic injured patients that are rapidly bleeding to death from injuries to their chest, abdomen or pelvis. This stops blood flow beyond the balloon, essentially halting any bleeding, while also stopping all blood flow distal to the balloon. The REBOA is the only FDA approved catheter of its kind that can be used outside the hospital, emergency room and clinical setting
Section C: Justification for Soliciting from a Single Source
Unique capabilities/supplies possessed by only one contractor as follows:
- Pryor Medical Devices is the sole provider and ONLY manufacture of the REBOA Catheter.
- Pryor Medical REBOA Catheter is the only FDA approved Resuscitative Endovascular Balloon Occlusion of the Aorta Catheter that can be used outside of Hospital, ER, and Clinical facilities.
- Special Operations Surgical Team (SOST) Surgeons/Emergency Physicians have received specialized REBOA Catheter placement/trauma applications training.
- Pryor Medical REBOA Catheter has great potential in stopping internal hemorrhage, increasing the chance of survivability of warriors suffering battlefield traumatic injuries
Section D: Efforts to Obtain Competition
Internet Search
- Currently, there is NO other Resuscitative Endovascular Balloon Occlusion of the Aorta Catheter that can be used during SOST missions, environments, and austere locations.
- There is NO other “FDA” Approved Resuscitative Endovascular Balloon Occlusion of the Aorta Catheter on the market.
- Market Research showed that Pryor Medical is sole provider of the ER-REBOA Catheter catalog number ER7232A
Section E: Steps to Preclude Future Single Source Awards
Through every available means, AFSOC/SG will continue to monitor market information and technical publications to determine whether any other source can meet our needs. In addition, minimum requirements for any future requirements as described herein will be shared with industry to encourage other manufacturers to begin producing similar compatible products.
Section F: Contracting Officer's Determination
I have determined, in accordance with FAR 13.106-1(b)(1)(SAP) that the circumstances of this contract action deem only one source is reasonably available.
Date
Typed Name and Rank/Grade of Requiring Activity CC
REBECCA W. CARTER, Lt. COL, USAF, BSC
Chief, Modernization Division
Signature of Commander
Date
Typed Name and Rank/Grade of Contracting Officer
Signature of Contracting Officer