Salient Characteristics.pdf
PDF 119 KB Posted
- Attached to
- 673 SFS Alarm Monitor Workstations
- Solicitation number
- F1W3SA4129AW01
About this file
This document appears to be a set of salient characteristics detailing the requirements for six (6) Vindicator Intrusion Detection System Administrator Workstations and three (3) AE SAW 2 Workstations, as well as associated supporting hardware, for use at Joint Base Elmendorf-Richardson (JBER). The workstations and hardware must be compatible with the Vindicator Intrusion Detection System software and operate on Windows 10 or newer, with specific hardware requirements including minimum 32GB RAM, RAID 1 processors, and 2U rack mount compatibility. Additionally, the document outlines requirements for three (3) AE VCC 2 Client Workstations, six (6) 24" Full HD monitors, three (3) Matrox Exo 3 High-Performance IP KVM Extenders, and other supporting cables and accessories. These components are required to maintain JBER's Electronic Intrusion Detection System and Electronic Entry Control Systems used at Protection Level facilities. The related federal contract opportunity, Solicitation Number F1W3SA4129AW01, is a pre-solicitation from the Department of the Air Force Pacific Air Forces for the 673 SFS Alarm Monitor Workstations.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Six (6) Vindicator Intrusion Detec�on System Administrator Worksta�ons with Associated Support Hardware.
• Three (3) AE SAW 2 Work Sta�ons:
o Must be on Non-Nuclear CMD Lis�ng o Must be compa�ble with the Vindicator Intrusion Detec�on System So�ware o Must operate on Windows 10 or newer OS o Minimum 32 Gb RAM o RAID 1 Processor o Compa�ble with 2U Rack Mount
• Three (3) AE VCC 2 Client Worksta�ons with Worksta�on Tower Chassis Upgrade:
o Must be on Non-Nuclear CMD Lis�ng o Must be compa�ble with the Vindicator Intrusion Detec�on System So�ware o Must operate on Windows 10 or newer OS o Minimum 32 Gb RAM o RAID 1 Processor o Compa�ble with 2U Rack Mount
• Six (6) Monitors:
o 24” Full HD 1080P, 1920x1080, w/VGA, HDMI, USB3.2 Gen 1 Upstream, 4x USB 3.2 Gen 1
Downstream
• Three (3) Matrox Ex�o 3 High-Performance IP KVM Extenders Transmiters
• Three (3) 6’ mini displayport to HDMI Cables o 4K 30 hz Monitor Adapter Cables – mDP, PC or Macbook to HDMI display
• Three (3) 10’ USB 2.0 Cer�fied A to B -M/M Cables
• Two (2) Matrox Ex�o 3 KVM Rack Moun�ng Kits
• One (1) Marox Ex�o 3 High-Performance IP KVM Extenders Receiver
• One (1) Monochroma�c Laser Jet Printer w/toner cartridge
• Three (3) 6’ VESA Cer�fied Mini DisplayPort to Display Port 1.4 Cables o 8K 60hz HDR – Super UHD mDP to DP 1.4 monitor video cables
Workstations are required for the monitoring, input and diagnostics required to maintain JBER's Electronic Intrusion Detection System and Electronic Entry Control Systems used at the Protection Level (PL) facilities at
JBER.
If not approved the capability to operate and maintain the Electronic Intrusion Detection System would not be compliant with DAFI 31-101, resulting in catastrophic base defense repercussions.
File details come from the government source that posted it. Updated .