This document contains the Salient Characteristics for a Temperature Controlled Emergency Safety Shower with Eye/Face Wash (240V) required by the Department of the Air Force, Air Mobility Command.

The key details are: The Eyewash station must meet or exceed ANSI Z358 standards to provide tepid water between 60-100°F and include a 79-gallon tank with a 3kW, 240V heater, a maximum 20 GPM flow rate, and stainless-steel inner pipework. The station will be installed on a concrete pad near building 907 and must carry a 1-year commercial warranty. The related federal contract opportunity, solicitation number F1M3E34116AQ01, is for the purchase of this Eyewash station or an "equal" product according to the attached Salient Characteristics. The contracting agency is the Department of the Air Force, Air Mobility Command.

View the file

Other files

File Type Posted
Combo Solicitation - FY24 Safety Shower.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS

Hughes TC100KS45G-2H (“or equal”) Temperature Controlled Emergency Safety Shower with Eye/Face Wash (240V)

I. GENERAL OVERVIEW.

628 CES Water and Fuels System Maintenance shop requires the purchase of the following Eyewash station to provide critical emergency safety equipment intended to mitigate eye injuries when control methods do not prevent exposure to a physical or chemical irritant or a biological agent. ANSI Z358 requires emergency shower and eyewash stations to provide tepid water in the range of 60 F to 100 F(16 C to 38 C). Temperatures that exceed this range can scald the injured person and cause a higher rate of chemical absorption by the skin. This Eyewash station will be utilized on a concrete pad at ground level near Pier by building 907. Eyewash station shall meet or exceed the requirements as stated within this document. Vendors shall provide product literature and warranty for all products within their submission. The government will not provide a lay down area for freight carrier, any overnight parking/storage will require advance permission from the government. Eyewash will carry a 1 year commercial warranty from the vendor. The vendor will repair or replace all items found defective at no cost to the government within that time frame.

II. SPECIFICATIONS.

At a minimum the equipment and accessories shall possess the following specifications:

- Specifications:

- 79 US gallon tank with 3kW,240V heater

- Maximum Water Flow : 20 GPM Shower

- Includes : 1 1/4 in Male NPT

- Mount Type : Floor Mount

- High flow rate thermostatically controlled mixing valve ensures the temperature is maintained at between 68–77-degree Fahrenheit

- Eye/face wash with integral lid ensures that the bowl remains clean and free from contamination.

- Stainless-steel inner pipework for improved corrosion resistance

- Primary Voltage Requirements:

- Primary voltage: 240V Single Phase, 60/50Hz