PVD Confirmed Salient Characteristics REDACTED.pdf
PDF 201 KB Posted
- Solicitation number
- F1C3465147A001
About this file
This document is a Requirement Description with Salient Characteristics for Portable Vapor Detectors (PVDs) to support Explosive Ordnance Disposal (EOD) operations for the THAAD missile system. The PVDs must meet specific technical requirements, including detecting Dinitrogen Tetroxide (N2O4) and Monomethyl Hydrazine (MMH) gases at a minimum concentration of 20 ppm, be single-man portable while wearing Level-A Personal Protective Equipment, and have a probe capable of interfacing with THAAD missile tubes.
Additional critical specifications include battery-powered operation with a minimum continuous usage time of 4 hours, and certification for intrinsic safety in explosive vapor environments. The receiving information indicates the document is to be marked for MSgt Christopher Lavoie, with a delivery address of Unit 14007 Bldg 2600, APO, AP 96543-4009, suggesting this is a military procurement requirement for specialized detection equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36 CES CED EOD J and A Portable Vapor Detectors REDACTED.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUIREMENT DESCRIPTION WITH SALIENT CHARACTERISTICS
In detail, please describe those physical, functional, performance, or material element qualities of an item that are essential to ensure that the intended use of the item can be satisfactorily realized.
Portable Vapor Detectors for EOD Support to THAAD
This is a description for portable vapor detectors (PVDs):
The PVDs must meet the following characteristics at minimum:
The ability to detect Dinitrogen Tetroxide (N2O4) and Monomethyl Hydrazine (MMH).
Be single-man portable while in Level-A PPE.
Have a probe capable of interfacing with the THAAD missile tube.
Capable of detecting at least the IDLH range of 20 ppm for both gases.
Use batteries for portability.
Usable for at least 4 hours continuously.
Be certified as intrinsically safe for use in explosive vapor environments.
Receiving Information Mark for MSgt Christopher Lavoie Unit 14007 Bldg 2600
APO, AP 96543-4009
File details come from the government source that posted it. Updated .