Exhibit L Program For Design.xls
XLS spreadsheet 168 KB Posted
- Attached to
- X1AA--New Replace Childress Clinic Lease
- Solicitation number
- 36C25721R0082
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Exhibit A GSA FORM 1364A.pdf | ||
| Exhibit J GSA Form12000.docx | DOCX document | |
| Exhibit C.1 Scope of Work Price List.xlsx | XLSX spreadsheet | |
| Exhibit E Wage Determination - Childress county.pdf | ||
| Exhibit I Security Requirements (Level II) 06.2018.pdf | ||
| Exhibit C Scope of Work.pdf | ||
| Exhibit G Rent table.xlsx | XLSX spreadsheet | |
| Exhibit F GSA1217 - Lessor Annual Cost Statement.pdf | ||
| Exhibit C.2 Childress Schedule B PACT 4292020.xls | XLS spreadsheet | |
| Exhibit B GSA FORM 1364A-1.pdf | ||
| Exhibit H 3516A Simplified Solicitation Provisions.pdf | ||
| RLP R100A Childress.pdf | ||
| Lease 36C25721L0008 L100A.docx | DOCX document | |
| Exhibit K GSA Form 3517B_Rev_10 2020.pdf | ||
| Exhibit I.1 Security Unit Price List FSL II 4 25 17.xlsx | XLSX spreadsheet |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C-Space Accounting Summary
| Space Program/Space Accounting Summary | ||||||||
| Department | Program Net Area NSF | Designed Net Area NSF | Variance | Program | Designed Dept. Gross DGSF | Actual Ratio Dept. Gross /Net | Building Gross Area BGSF | |
| Conversion | Dept. Gross DGSF | |||||||
| IT | 170 | -170 | 1.35 | 230 | 0.00 | |||
| GENRAL AND COMMON SPACE | 320 | -320 | 1.35 | 432 | 0.00 | |||
| PATEINT CARE | 1,118 | -1,118 | 1.35 | 1,509 | 0.00 | |||
| NON-PATEINT CARE | 230 | -230 | 1.35 | 311 | 0.00 | |||
| Department Total | 1,838 | 0 | -1,838 | 2,481 | 0 |
&L&"Arial,Bold"SOLICITATION FOR OFFERS&C&"Arial,Bold"CHILDRESS OUTPATIENT CLINIC CHILDRESS, TX&R&"Arial,Bold"SFO NO.
&L &"Arial,Bold"Lessor _____ Gov't ______&C&"Arial,Bold"Part V Schedule C Page 9 of 9&R &"Arial,Bold"_______ of _______ Pages &L&"Arial,Bold"SOLICITATION FOR OFFERS&C&"Arial,Bold"OUTPATIENT CLINIC [INSERT LOCATION OF FACILITY]&R&"Arial,Bold"SFO NO. V101-183R-xxx-xxx-xx &L &"Arial,Bold"Lessor _____ Gov't ______&C&"Arial,Bold"Part V Schedule C Page 9 of 9&R &"Arial,Bold"_______ of _______ Pages
C-SpaceProgram-Finish Schedule
| SPACE PROGRAM, ROOM FINISH, DOOR AND HARDWARE SCHEDULE | |||||||||||||||||||||||
| Department | Area | Room Code | Design Guide Plate | Room Number | Function | Qty | Net Area sf | Area m2 | Net Area m2 | Omitted Spaces | Lessor Space | Designed Net Area | Room # | Floor | Base | Wall | Wains | Ceiling | Height | Clg Height | Frame, Door & Size | HDW # | Notes, Air Changes |
| CHILDRESS OUTPATIENT CLINIC | |||||||||||||||||||||||
| IT | |||||||||||||||||||||||
| IT | Voice/Data | Telecommunications Room (IT Closet) | 1 | 110 | AF | RB 4" | GWB-P | AT | 1 S | 3E | Walls to Deck or Hard Ceiling |
65-80°, 24/7, 2AC, N+1, 30-60% RH, 1hr Fire Rated, 3/4hr Fire Rated Door
| V.A. Dept. Total = | 170 | ||||||||||||||
| Omitted Areas = | 0 | ||||||||||||||
| Lessor Dept. Total = | 0 | ||||||||||||||
| GENERAL AND COMMON SPACES | |||||||||||||||
| Lobby | Waiting/Education | General Waiting Area/Patient Education | 1 | 100 | LVT | RB | GWB-P | AT-GWB | 10'-0" | 1/2 Q-T | 11 | 6AC | |||
| Lobby | Reception | Reception | 1 | 100 | LVT | RB 4" | GWB-P | AT-GWB | 10'-0" | 6AC | |||||
| Admin | Other | Alcove, Wheelchair/Stretcher | 2 | 50 | LVT | RB | GWB-P | AT | |||||||
| Lobby | Reception | Public Toilet Unisex | 1 | 70 | PT | RB | GWB-P | AT | 19 U | 3E | 10AC, Double NEG AIR, Exhausted | ||||
| V.A. Dept. Total = | 320 | ||||||||||||||
| Omitted Areas = | 0 | ||||||||||||||
| Lessor Dept. Total = | 0 | ||||||||||||||
| PATIENT CARE | |||||||||||||||
| Medical | Exam | Exam Room | 2 | 125 | LVT | RB | GWB-P | AT-GWB | Sliding dr | 6AC, STC 40 | |||||
| Medical | Exam | Women's Health Exam Room | 1 | 125 | LVT | RB | GWB-P | AT | Sliding dr | 6AC, STC 40 | |||||
| Medical | Exam | Women's Health Exam Room Toilet | 1 | 70 | PT | PT | GWB-P | PT 4'-0" | AT | 19 U | 2G | 10AC, Double NEG AIR, Exhausted | |||
| Admin | Other | Lounge, Clinical Staff | 1 | 200 | LVT | RB | GWB-P | AT | 1 S | SH-4 | 4AC | ||||
| Admin | Admin | Teamwork Zone | 1 | 400 | LVT | RB | GWB-P | AT | 1 S | 3E | 6AC | ||||
| Medical | Exam | Blood Specimen Collection Room | 1 | 73 | WSF | WSF 4" | GWB-SC | AT | 1 V | 4 | 6AC | ||||
| V.A. Dept. Total = | 1,118 | ||||||||||||||
| Omitted Areas = | 0 | ||||||||||||||
| Lessor Dept. Total = | 0 | ||||||||||||||
| NON-PATIENT CARE | |||||||||||||||
| Admin | Other | Clean Utility | 1 | 50 | WSF | WSF | GWB-SC | RWC 4'-0" | AT | 11 F-V | SH-3C | 4AC, POS AIIR | |||
| Admin | Admin | Soiled Linen Room | 1 | 50 | WSF | WSF 4" | GWB-SC | RWC 4'-0" | AT-SP | 9' | 11 V | SH-3C | 10 AC, Double NEG AIR, Exhausted | ||
| EMS | Custodial | HAC Closet | 1 | 60 | QT | QT 4" | GWB-SC | CT 4'-0" | AT, SP | 1 U | 5D | 10AC, Double NEG AIR, Exhausted | |||
| Admin | Other | Toilet, Clinical Staff | 1 | 70 | PT | PT | GWB-P | CT 4'-0" | AT | 19 U | 2G | 10AC, Double NEG AIR, Exhausted | |||
| V.A. Dept. Total = | 230 | ||||||||||||||
| Omitted Areas = | 0 | ||||||||||||||
| Lessor Dept. Total = | 0 |
&L&"Arial,Bold"SOLICITATION FOR OFFERS&C&"Arial,Bold"Childress Outpatient Clinic&R&"Arial,Bold"SFO NO.
&L&"Arial,Bold" ______Lessor Gov't_______&C&"Arial,Bold" Space Program, Room Finish, Door and Hardware--Schedule E&R&"Arial,Bold"Page &P of &N General Notes for Room Finish, Door and Hardware Schedule
1. Room areas are approximate where multiple rooms referenced
2. Provide Sound Control per VA specifications
3. All ceiling heights 9'-0" above finished floor unless noted otherwise.
4. Follow VA Sound Transmission Control Guidelines unless noted otherwise.
5. All room walls to extend 6" above the ceiling line unless noted otherwise.
6. Provide fire rated construction per code requirements.
7. All Acoustical ceiling tile 2x2 unless noted otherwise.
8. Partitions on both sides of major corridors shall be fixed full height to underside of floor/roof structure above.
9. Where ceramic tile is installed on walls, install on cement backer board, typical.
&L&"Arial,Bold"SOLICITATION FOR OFFERS&C&"Arial,Bold"OUTPATIENT CLINIC AUSTIN, TX&R&"Arial,Bold"SFO NO.V101-183R-xxx-xxx-xx &L&"Arial,Bold" ______Lessor Gov't_______&C&"Arial,Bold" Space Program, Room Finish, Door and Hardware--Schedule C Page &P of &N&R&"Arial,Bold" ___ of _____ Pages
Legend
| Designed to the PACT (Patient Aligned Care Team) Space Module, VA HVAC Design Manual, Office of Information and Technology Design Guide, VA Electrical Design Manual, VA Plumbing Design Manual, NFPA, NEC, and ASHRAE | ||
| DOOR & FRAME SCHEDULE NOTES AND LEGENDS | ||
| HW # | Single or Pair | Function |
| 1 | Single | Non-locking. May be push/pull, hospital latch, or latch set. |
| 2 | Single | Privacy. May be standard privacy, hospital privacy (double thumb turn), keyed indicator privacy, or staff key-only entry indicator privacy. |
| 3 | Single | Office. May include standard office with thumb turn or entry lock with thumb turn and deadlock |
| 4 | Single | Classroom. May include standard classroom, double-cylinder utility function (free egress always available), classroom hospital latch. |
| 5 | Single | Storeroom. May include standard storeroom, storeroom with deadbolt, institutional lock (lockable both sides). |
| 6 | Single | Panic. May include exit only, passage lever, lockable lever, storeroom lever, pull. |
| 7 | Single | Special. Could include roll-up doors, Won doors, operable partitions, sliding doors, ICU/CCU doors, folding doors, etc. |
| 8 | Pair | Non-locking. May be push/pull, hospital latch, or latch set. |
| 9 | Pair | Entry. May include entry lock with thumb turn and deadlock. |
| 10 | Pair | Classroom. May include standard classroom, double-cylinder utility function (free egress always available), classroom hospital latch. |
| 11 | Pair | Storeroom. May include standard storeroom, storeroom with deadbolt, institutional lock (lockable both sides). |
| 12 | Pair | Panic. May include exit only, passage lever, lockable lever, storeroom lever, pulls |
| 13 | Pair | Special. Could include sliding doors, folding doors, etc. |
| SH-1 | --- | Left blank at this time |
| SH-2 | Single | Monitored door. Alarm contacts only |
| SH-3 | Single | Electric lockset. |
| SH-4 | Single | Electric panic. |
| SH-5 | --- | Left blank at this time |
| SH-6 | --- | Left blank at this time |
| SH-7 | --- | Left blank at this time |
| SH-8 | --- | Left blank at this time |
| SH-9 | Pair | Electric lockset. |
| SH-10 | Pair | Electric lockset. |
| SH-11 | --- | Not in specification at this time |
| SH-12 | Pair | Controlled egress door. Audible alarm (may include alarm in panic bar) or delayed egress panic. |
| Section 08 71 00 Door Hardware of PG 18-1 Master Construction Specifications has full descriptions of each door hardware | ||
| Frame Type | Description | |
| 1 | HM 2" wide frame on jambs and header | |
| 2 | HM 2" wide frame on jambs and 4" header | |
| 3 | HM Galvanized 2" wide frame on jambs and header | |
| 4 | HM 2" wide frame on jambs and header- w/ sound proofing | |
| 5 | HM 2" wide frame on jambs and header- Lead Lined | |
| 6 | HM 2" wide frame on jambs and header- Galvanized | |
| 7 | Aluminum Storefront 2" nominal frame | |
| 8 | HM 2" wide frame on jambs and 4" header- Galvanized | |
| Door Type | Description | |
| 1 | Hollow Metal | |
| 2 | Wood Door- Solid Core | |
| 3 | Hollow Metal- Insulated Core | |
| 4 | Hollow Metal Galvanized- Insulated Core | |
| 5 | Wood Door- Lead Lined | |
| 6 | Aluminum Storefront with 1/4" tempered glazing | |
| 7 | Plastic Door with 12"x12" view panel | |
| See SD080000-01.01 For Door Type | ||
| Door Size | ||
| Mark | Width Height | |
| A | 547.2 mm (1'-6") 2032.0 mm (6'-8") | |
| B | 609.6 mm (2'-0") 2032.0 mm (6'-8") | |
| C | 660.4 mm (2'-2") 2032.0 mm (6'-8") | |
| D | 711.2 mm (2'-4") 2032.0 mm (6'-8") | |
| E | 762.0 mm (2'-6") 2032.0 mm (6'-8") | |
| F | 812.8 mm (2'-8") 2032.0 mm (6'-8") | |
| G | 863.6 mm (2'-10") 2032.0 mm (6'-8") | |
| H | 914.4 mm (3'-0") 2032.0 mm (6'-8") | |
| I | 965.2 mm (3'-2") 2032.0 mm (6'-8") | |
| J | 1016.0 mm (3'-4") 2032.0 mm (6'-8") | |
| K | 1117.6 mm (3'-8") 2032.0 mm (6'-8") | |
| L | 1168.4 mm (3'-10") 2032.0 mm (6'-8") | |
| M | 547.2 mm (1'-6") 2133.6 mm (7'-0") | |
| N | 609.6 mm (2'-0") 2133.6 mm (7'-0") | |
| O | 660.4 mm (2'-2") 2133.6 mm (7'-0") | |
| P | 711.2 mm (2'-4") 2133.6 mm (7'-0") | |
| Q | 762.0 mm (2'-6") 2133.6 mm (7'-0") | |
| R | 812.8 mm (2'-8") 2133.6 mm (7'-0") | |
| S | 914.4 mm (3'-0") 2133.6 mm (7'-0") | |
| T | 1016.0 mm (3'-4") 2133.6 mm (7'-0") | |
| U | 1066.8 mm (3'-6") 2133.6 mm (7'-0") | |
| V | 1117.6 mm (3'-8") 2133.6 mm (7'-0") | |
| W | 1168.4 mm (3'-10") 2133.6 mm (7'-0") | |
| X | 1219.2 mm (4'-0") 2133.6 mm (7'-0") | |
| Y | 914.4 mm (3'-0") 2438.4 mm (8'-0") | |
| Z | UNASSIGNED | |
| Door Application Codes | ||
| A | Laminated Glazing | |
| ADO | Automatic Door Operator (Swing or Slide) | |
| ADK | Audible Alarm (On Egress) | |
| CL | Stand-Alone Card Reader Lock | |
| CR | Card Reader | |
| D | Double Glazed Tempered Glazing | |
| DE | Delayed Egress | |
| DPS | Door Position Switch (Door Contact) | |
| H | Electric Hold-Open (Wall-Magnet Preferred, or Electro-Mechanical Closer-Holder) | |
| IC | Intercom | |
| ID | Integrated Door Assembly | |
| IL | Interlocked | |
| L | Louver | |
| LL | Lead-Lined Door | |
| LP | Light Proof Louver | |
| M | Mechanical Seal for Light Proof & Sound Retarding Door | |
| P | Panic Hardware | |
| PB | Stand-Alone Pushbutton Lock | |
| RF | Radiofrequency Shielded Door | |
| RR | Remote Release Button | |
| STC | Acoustic Door Assembly (Indicate STC Rating #) | |
| T | Tempered Glazing | |
| TL | Timer Lock (Electric Lock/Unlock of Door Using Electric Timer) | |
| U | Undercut 1" | |
| V | Lead Glass | |
| W | Fire rated Glazing | |
| General Door Notes | ||
| No. | Description | |
| 1 | Verify Quantities with final design | |
| 2 | Verify Door vision panels with final design | |
| 3 | Provide laminated or tempered safety glazing to comply with VA standards | |
| 4 | Use 36"w x 36"h glazing in door with Blind. | |
| 5 | Use 24"w x 36"h glazing in door. | |
| 6 | Use 4"w x 24"h fire rated glazing in door. | |
| 7 | Use metal security door. | |
| 8 | All window door vision glazing panels to be 9" W x 36" H unless noted otherwise | |
| Air Pressure Notes | ||
| Double Negative can be achieved when exhausted and/or returen air exceed air supply air flow. The ai deficiency infiltrates from the adjoining space. |
&LSOLICITATION FOR OFFERS&CCHILDRESS OUTPATIENT CLINIC
CHILDRESS, TX&RSF0 NO.
FINISH SCHEDULE ABBREVIATIONS
| ADO | Automatic Door Operator |
| AF | Access Flooring |
| AT | Acoustical Tile Ceiling Panels |
| AT-SP | Acoustical Ceiling (with sprayed plastic finish) |
| AWP | Acoustical Wall Panels |
| C | Concrete |
| CBB | Concrete Backer Board |
| CMU | Concrete Masonry Unit |
| CP | Carpet (Without Cushion Broadloom) |
| CPT | Carpet Tile |
| CT | Ceramic Tile |
| EPY | Epoxy (Coatings) |
| EXP | Exposed |
GL Glass (Glazing)
| GWB | Gypsum Wallboard Systems |
| HW | Hardware Set |
LN Linoleum LVT Luxury Vinyl Tile MAT Carpet Mat (Walk-Off Mat) NO Number PC Precast (Architectural Precast Concrete Pavers)
| P | Paint (Exterior, Interior, Transparent Finishes) |
| PRB | Profile Base |
PT Porcelain Tile (Floor and Base)
| QT | Quarry Tile |
| RB | Resilient Base ( Rubber, Vinyl) |
RES* Resinous Flooring RES-W* Resinous/Epoxy Wall/Ceiling
| RF | Rubber Flooring |
| RRF | Raised Rubber Flooring |
| RSF | Resilient Sheet Flooring (Chemically Welded Seems) |
| RWC | Rigid Wall Covering (Wall Protection Roll or Sheet) |
| S | Solid Surface |
| SC | High Build Glazed Coating (Special Coating) |
| SD | Static Dissipative |
| SF | Special Faced |
| SS | Stainless Steel |
| ST | Stone (cast) |
| SVT | Solid Vinyl Floor Tile |
| TER | Terrazzo, Poured |
| TT | Terrazzo Tile (Plastic Matrix) |
| VT | Vinyl Tile (High Content Vinyl) |
| VWC | Vinyl Wall Covering |
| WD | Wood |
| WSF | Welded Seam Sheet Resilient Flooring |
SUMMARY
| SCHEDULE E SUMMARY | |||||||||
| Achieved Net to Gross Factors T-M Schematics for Victoria OPC | |||||||||
| Departments | NSF Program Area | NSF Design Area | Variance | NUSF (Measured) | Additional BGSF | NUSF / Design NSF (F/D) | NUSF / NSF Program Area (F/C) | VA Net to Gross Factors | |
| ADMINISTRATIVE SERVICES | |||||||||
| IT | 170 | 0.00 | 0.00 | ||||||
| GENERAL AND COMMON SPACES | 320 | 0.00 | 0.00 | ||||||
| PATIENT CARE | 1,118 | 0.00 | 0.00 | ||||||
| NON-PATIENT CARE | 230 | 0.00 | 0.00 | ||||||
| 0.00 | 0.00 | ||||||||
| 0.00 | 0.00 | ||||||||
| 0.00 | 0.00 | ||||||||
| Mechanical Stacks & Shafts | 0.00 | 0.00 | |||||||
| Vertical Circulation | 0.00 | 0.00 | |||||||
| Other Circulation | 0.00 | 0.00 | |||||||
| Bldg. Equipment & Services | 0.00 | 0.00 | |||||||
| HAC | 0.00 | 0.00 | |||||||
| IDF | 0.00 | 0.00 | |||||||
| Special Systems/Signal | 0.00 | 0.00 | |||||||
| Mechanical Penthouses | 0.00 | 0.00 | |||||||
| Exterior Construction (Dock, Dumpsters, etc) | 0.00 | 0.00 | |||||||
| Exterior Walls | 0.00 | 0.00 | |||||||
| Department Total | 1,838 | - 0 | - 0 | - 0 | - 0 | ||||
| BOMA | 0 | ||||||||
| Building Total GSF | - 0 | DGSF to BGSF Factor | |||||||
| Bldg Net to Gross | 0.00 | 0.00 | |||||||
| 0.00 |
&L&"Arial,Bold"SOLICITION FOR OFFERS&C&"Arial,Bold"CHILDRESS OUTPATIENT CLINIC CHILDRESS, TX&R&"Arial,Bold"SFO NO.
&L&"Arial,Bold"_______Lessor Gov't_______&C&"Arial,Bold"Schedule E Summary Space Program, Room Finish, Door and Hardware Schedule&R&"Arial,Bold"Page &P of &N
File details come from the government source that posted it. Updated .