This document is Exhibit E - Drawings & Specifications for the Northwest Septic Lines contract opportunity issued by the University of Houston Victoria located in Victoria County, Texas. The contract requires the demolition and replacement of existing sanitary sewer lines, the addition of a canopy and drain to the west side door, flooring replacement, and the addition of a door from the library storage to the break room. No specific quantities or timelines are provided. The document contains technical drawings and specifications detailing the required work.
The pricing terms, set asides, and funding sources are not included in this Exhibit. It appears to be a technical document outlining the scope of work for the proposed project rather than contractual or financial details.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B O A R D O F R E G E N T S
OWNER / PROJ. MAN.
UNIVERSITY OF
HOUSTON-VICTORIA
3007 N BEN WILSON ST.
VICTORIA,TX. 77901
361-485-4550 P
CIVIL
DALLY + ASSOCIATES, INC.
9800 RICHMOND AVE
SUITE 460,
HOUSTON, TX. 787042
210-349-9098 P
STRUCTURAL
IES
10001 REUNION PLACE
SUITE 200, UNION SQUARE II
SAN ANTONIO, TX. 78216
210-349-9098 P
ARCHITECT
PBK ARCHITECTS
601 N.W. LOOP 410
SUITE 400
SAN ANTONIO, TX. 78216
210-829-0123 P 210-829-0578 F
MEPT
LEAF ENGINEERS
601 N.W. LOOP 410
SUITE 400
SAN ANTONIO, TX. 78216
210-638-7200 P
UNIVERSITY OF HOUSTON VICTORIA
R. VIC MORGAN
PRESIDENT
WAYNE B. BERAN
VICE PRESIDENT
ADMINISTRATION & FINANCE
MATTHEW ALEXANDER
DIRECTOR
CAPITAL PROJECTS
UNIVERSITY OF HOUSTON SYSTEM
RENU KHATOR
CHANCELLOR
JIM McSHAN
SENIOR VICE CHANCELLOR
ADMINISTRATION & FINANCE
NORTHWEST CAMPUS - SEWER RENOVATION
UNIVERSITY OF HOUSTON VICTORIA
04/30/2024
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
1604 EAST AIRLINE ROAD
VICTORIA, TEXAS 77901
PLAN
NORTH
NORTH
PROJECT LOCATION
SHEET NUMBER
SHEET DISCIPLINE TYPE
DISCIPLINE
A2.01A SEQUENCE (.01 - .99......etc.)
BUILDING AREA
0 GENERAL
1 SITE
2 FLOOR PLANS (Note: Flip Sheets are Schedules)
3 ROOF
4 ENLARGED PLANS
5 PLAN DETAILS
6 ELEVATIONS (Exterior and Interior)
7 PARTITION TYPES, WALL SECTIONS
8 CASEWORK, MILLWORK
9 DOORS, WINDOWS, FRAMES
10 CEILINGS
G GENERAL
C CIVIL
L LANDSCAPE
CA SPORTS
S STRUCTURAL
D DEMOLITION
A ARCHITECTURAL
M MECHANICAL
E ELECTRICAL
P PLUMBING
T TECHNOLOGY
DIMENSIONS
NOTE: all dimensions to face of wall unless otherwise noted
GRID LINE
FLOOR LINE
MATCH LINE
INTERIOR ELEVATION SYMBOL
DOOR DESIGNATION
EXTERIOR ELEVATION SYMBOL
PLAN OR DETAIL ENLARGED
DETAIL SECTIONS
AND VERTICAL SECTIONS
PARTITION TYPE
REVISION NUMBER
DETAIL ENLARGED
WINDOW DESIGNATION
EXISTING ELEVATION
FINISH GRADE ELEVATION
AREA DRAIN
PROPERTY LINE
NO.
NO.
A1.01 1
A1.01 12
10'-0".
6'-0". 4'-0".
18'-6"
SPOT COORDINATE
KEY NOTE
BREAK LINE
MATCH LINE
SEE XX/X-XXX
EQUIPMENT DESIGNATION
TOILET ACCESSORY SYMBOL
ROOM NAME AND NUMBER
SPOT ELEVATION
WHICH CONTINUATION
SHEET NUMBER ON
IS FOUND
PROPERTY LINE
FHC
FHC
FIRE HOSE CABINET
FEC
FEC
FIRE EXTINGUISHER CABINET
(RECESSED AND SURFACE MOUNTED)
(RECESSED AND SURFACE MOUNTED)
SHOWER HEAD
RTU
ROOF TOP UNIT
REFER TO MECHANICAL FOR
TYPE
F.D.
FLOOR SINK
FLOOR DRAIN
OVERFLOW DRAIN AND
ROOF DRAIN
F.S.
FENCING (WITH POSTS)
OVERFLOW DRAIN
ROOF DRAIN
EQ-#
TA-1
A-100
EXISTING PARTITION
NEW PARTITION
N - 58' 2" E - 150' 11"
A-100
SECTION CALLOUT SYMBOL
Name Elevation
1i
1t A
A101
Room name
A101
48"
48"
19"
48"
48"
27"
36"
48"
34"
28" - 34"
27"
27"
17"
17" - 19"
33" - 36"
MIRRORS: Max. Height to Bottom of Reflective Surface
TOILET PAPER DISPENSER: Height to Center of Roll (Max)
PAPER TOWEL DISPENSER: Height to Operating Mechanism
SWITCHES AND CONTROLS
Side Approach (Max)
Frontal Approach (Max)
DRINKING FOUNTAINS:
Knee Clearance (Min)
To Spout (Max)
Knee Clearance (Min)
Frontal Approach (Max)
SHELVES, DISPENSERS: Max. Height to Control Device
WATER CLOSET: To Top of Seat
URINAL: Max. To Rim of Basin
FIXED OR BUILT-IN:
Height of Tables or Counter:
Side Approach (Max)
Knee Clearance (Min)
LAVATORIES: Front Approach
To Top (Max)
Grab Bar Height
DESCRIPTION
To Faucet (Max)
44"Flush Control Height (Max)
44"Flush Control Height (Max)
40"At Lavatories and Counter Tops
35"Full Length
MIRRORS: Min. Height to Top of Reflective Surface
74"Full Length
25"
Ages: 13 - Adult (Grades 8 and Above)
EXIT
0"
M
A X
M
IN
5"
9" 12"
T Y
P
IC
A L
M
A X
EQ EQ
FIRE ALARM (COMBINATION
SPEAKER AND STROBE)
FIREMAN'S PHONE JACK
WALL MOUNTED EXIT LIGHT
LIGHT SWITCH AND DIMMER
THERMOSTAT OR OTHER
CONTROL DEVICE
ELECTRIC, TELEPHONE,
OR DATA RECEPTACLE
ALIGN ITEMS WHEN POSSIBLE
A T
C O
U N
T E
R S
M
A X
10 - 24"
OBSTRUCTION
MIN.
24"
ALIGN STACKED DEVICES
WHERE POSSIBLE
M
A X
SIGNAGE
18"
CLEAR SPACE AT
TACTILE SIGNAGE
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
4/30/2024 11:33:41 PM
A u to d e sk
D o cs
/U
H V
U
N R e n o va tio n /P
B K
U H
V N
W S
E W
E R
R
.r vt
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
G0.01
INDEX, DRAWING
CONVENTIONS, AND
LOCATION MAP
04/30/2024 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
K. BRITTAIN
C. WHITTINGSTALL
E A
S T
A
IR
L
IN
E R
O A
D
V
IC
T O
R
IA
T
E X
A S
G
.0
IN
D
E X
, D R
A W
IN
G
C O
N V
E N
T
IO
N S
, A N
D L
O C
A T
IO
N
M A
P
04/30/2024
A A.D. AREA DRAIN
A A.D.A. AMERICANS WITH DISABILITIES ACT
A A.D.A. 2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN
A A.D.A.A.G. AMERICANS WITH DISABILITIES ACT
ACCESSIBILITY GUIDELINES
A A.F.F. ABOVE FINISH FLOOR
A A.F.G. ABOVE FINISH GRADE
A A.H.J. ATHORITY HAVING JURISDICTION
A A/C AIR CONDITIONING
A ACC. ACCESSIBLE, ACCESSIBILITY
A ACP. ACOUSTICAL PANEL
A ACT. ACOUSTICAL TILE
A ADJ. ABADJUSTABLE
A ALT. ALTERNATE
A ALUM. ALUMINUM
A ASPH. ASPHALT
A ے ANGLE
B B.O.D. BOTTOM OF DECK
B B.U.R. BUILT-UP ROOF
B BD. BOARD
B BLDG. BUILDING
B BLK. BLOCK
B BM. BEAM
C C CHANNEL
C C.J. CONTROL JOINT
C C.M.U. CONCRETE MASONRY UNIT
C C.W. COLD WATER
C CAB, CABT CABINET
C CFMF COLD-FORMED METAL FRAMING
C CFSF COLD-FORMED STEEL FRAMING
C CL CENTERLINE
C CLG. CEILING
C CLR CLEAR
C COL. COLUMN
C COMP. COMPRESSIBLE
C CONC. CONCRETE
C COND. CONDITION
C CONT. CONTINUOUS
C CORR. CORRIDOR
C CPT. CARPET (ED)
C CT. CERAMIC TILE
C CTSK. COUNTER SINK
D D DRYER
D D.F. DRINKING FOUNTAIN
D D.P. DAMPPROOFING
D D.S. DOWN SPOUT
D DIA. DIAMETER
D DIM. DIMENSION
D DTL. DETAIL
D DWG. DRAWING
E E.J. EXPANSION JOINT
E E.Q. EQUAL
E EA. EACH
E EDF ELECTRIC DRINKING FOUNTAIN
E EL. ELEVATION (HEIGHT)
E ELEC. ELECTRICAL
E ELECT. ELECTRICAL
E ELEV ELEVATION (DRAWING)
E EQUIP EQUIPMENT
E EXIST EXISTING
E EXP EXPANSION
E EXT EXTERIOR
F F.E. FIRE EXTINGUISHER
F F.E.C. FIRE EXTINGUISHER CABINET
F F.H.C. FIRE HOSE CABINET
F FB. FACE BRICK
F FD. FLOOR DRAIN
F FIN. FINISH (ED)
F FIXT. FIXTURE
F FLR. FLOOR (ING)
F FLSHG. FLASHING
F FLUOR FLUORESCENT
F FRP FIBER REINFORCED PLASTIC
G G.B. GRAB BAR
G G.I. GALVANIZED IRON
G GA. GAUGE
G GALV. GALVANIZED
G GCMU GLAZED CONCRETE MASONRY UNIT
G GEN. GENERAL
G GEN. GENERAL
G GL. GLASS / GLAZING
G GL. GLASS
G GR. GRADE
G GTP. GLAZED TILE PAVER
G GYP. GYPSUM DRYWALL
H H.W. HOT WATER
H HM HOLLOW METAL FRAME
H HORIZ. HORIZONTAL
H HT. HEIGHT
I I.D. INSIDE DIAMETER
I I.P.S. IRON PIPE SIZE
I INSUL INSULATE (ED), (ION)
I INT. INTERIOR
J JT. JOINT
L L.P. LIGHT POLE
L LAM. LAMINATE (D)
L LAV. LAVATORY
L LT. LIGHT
L LT. WT. LIGHTWEIGHT
M M.O. MASONRY OPENING
M MAS. MASONRY
M MATL. MATERIAL (S)
M MAX. MAXIMUM
ARCHITECTURAL
A100 ARCHITECTURAL SITE PLAN - NEW
A101 COMPOSITE PLAN - FIRST FLOOR
A102 FLOOR PLAN, INTERIOR ELEVATIONS, PARTITION TYPES
A103 EXTERIOR ELEVATION, WALL SECTION, & SCHEDULES
A301 ROOF PLAN
GENERAL
G0.00 COVER SHEET
G0.01 INDEX, DRAWING CONVENTIONS, AND LOCATION MAP
ABBREVIATIONS DRAWING INDEX
SHEET NUMBERING
SITE LOCATION MAP
DEMOLITION
AD100 SITE DEMOLITION PLAN
AD101 ENLARGED DEMOLITION PLANS
PROXIMITY MAP
EAST AIRLINE ROAD
N O
R T
H L
A U
R E
N T
S T
R E
E T
DRAWING CONVENTIONS
M MB. MARKER BOARD
M MECH. MECHANICAL
M MEM MEMBRANE
M MEM. WP. MEMBRANE WATERPROOFING
M MEP MECHANICAL, ELECTRICAL,
PLUMBING
M MEPT MECHANICAL, ELECTRICAL,
PLUMBING, TECHNOLOGY
M MEZZ. MEZZANINE
M MFR. /
MANUF.
MANUFACTURE (R)
M MH. MANHOLE
M MIN. MINIMUM
M MISC. MISCELLANEOUS
M MOD MODULAR
M MTL METAL
M MTP. METAL TOILET PARTITION
N N.D. NAPKIN DISPOSAL
N N.I.C. NOT IN CONTRACT
N N.T.S. NOT TO SCALE
N N.V. NAPKIN VENDOR
N NO. NUMBER
N NOM. NOMINAL
O O.C. ON CENTER (S)
O O.C.E.W. ON CENTER EACH WAY
O O.D. OUTSIDE DIAMETER
O O.F.C.I. OWNER FURNISHED, CONTRACTOR
INSTALLED
O O.H. OPPOSITE HAND
O OPNG. OPENING
O OPP. OPPOSITE
P P. LAM. /
PLAM
PLASTIC LAMINATE
P P.C. PRECAST
P P.H. PAPER HOLDER
P P.L. PROPERTY LINE
P P.P. POWER POLE
P P.W.B. PREFINISHED WALL BOARD
P PL. PLATE
P PLUMB. PLUMBING
P PLYWD. PLYWOOD
P POL. POLISHED
P PR. PAIR
P PREFIN. PRE-FINISHED
P PT PRESSURE-TREATED
P PT. POINT
P PTD. PAINTED
Q Q.T. QUARRY TILE
R R / RAD RADIUS
R RCP REFLECTED CEILING PLAN
R RD ROOF DRAIN
R RE. , REF. REFER TO / REFERENCE / SEE
R RECP. RECEPTACLE
R REINF. REINFORCE (D), (ING)
R REQ'D. REQUIRED
R RES. RESILIENT
R REV. REVISION (S), REVISED
R RF RECREATIONAL RESILIENT
FLOORING
R RPG. RELOCATABLE PAINTED GYPSUM
BOARD
R RSS. ROD STOCK AND SEALANT
S S.C. SEALED CONCRETE
S S.D. SOAP DISPENSER
S S.N.D. SANITARY NAPKIN DISPOSAL
S SCHED SCHEDULE
S SCPL SOLID CORE PLASTIC LAMINATE
S SECT SECTION
S SHT SHEET
S SIM SIMILAR
S SPC SPECIAL COATING SYSTEM
S SPEC SPECIFICATION (S)
S SQ. SQUARE
S SS / SS.
STL.
STAINLESS STEEL
S STL STEEL
S STRUC /
STRUCT
STRUCTURAL
S SUSP SUSPENDED
S SVDF SHEET VINYL DANCE FLOORING
S SVF SHEET VINYL FLOORING
T T.A.S. TEXAS ACCESSIBLITY STANDARDS
(2012)
T T.B. TACK BOARD
T T.D.R. TOWEL DISPENSER AND RECEPTACL
T T.O. TOP OF
T T.O.B. TOP OF (WOOD) BLOCKING
T T.O.M. TOP OF MASONRY
T T.O.P. TOP OF PARAPET
T T.O.S. TOP OF STEEL
T T.T.D. TOILET TISSUE DISPENSER
T TEL TELEPHONE
T TERR TERRAZZO
T THK THICK (NESS)
T TYP TYPICAL
U U.N.O. UNLESS NOTED OTHERWISE
U UR. URINAL
V V VENT
V V.C.T. VINYL COMPOSITION TILE
V V.I.F. VERIFY IN FIELD
V VENT. VENTILATING, VENTILATED
V VER. VERIFY
V VERT. VERTICAL
V VGB (PREFINISHED) VINYL CLAD GYPSUM
BOARD
V VWC VINYL WALL COVERING
W W WASHING MACHINE
W W.P. WATER PROOFING
W W.S. WEATHERSTRIP
W W.W. WATER WELL
W W.W.F. WELDED WIRE FABRIC
W W.W.M. WOVEN WIRE MESH
W W/ WITH
W WC WATER CLOSET
W WD WOOD
W WDW WINDOW
W WT WEIGHT
CIVIL
C1.00 DEMOLITION PLAN
C2.00 LAYOUT & UTILITY PLAN
C3.00 PAVING PLAN
C4.00 SWPPP PLAN
C5.00 SITE DETAILS
STRUCTURAL
S104 ENLARGED FIRST FLOOR FRAMING PLAN - AREA A
S105 PARTIAL FIRST FLOOR FRAMING PLAN - AREA B
S401 SECTIONS AND DETAILS
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
BUILDING ENVELOPE
BEAM
T 210-638-7200
1/4" = 1'-0"
21 ACCESSIBILE MOUNTING HEIGHTS
3/8" = 1'-0"
27 MISC MOUNTING HEIGHTS
ACCESSIBILITY GUIDELINES
PLUMBING
P-000 PLUMBING SYMBOLS AND ABBREVIATIONS
PUD-101 1ST LEVEL UNDERFLOOR PLUMBING DEMO PLAN - COMPOSITE
PU-101 1ST LEVEL UNDERFLOOR PLUMBING PLAN - COMPOSITE
P-301 PLUMBING ROOF PLAN
P-401 PLUMBING ENLARGED PLAN
PROJECT LIMITS
PROJECT SITE
ALTERNATES:
1. PREFABRICATED AVADEK CANOPY IN LIEU OF
STEEL FRAMING
No. Description Date
LEGEND
PROPOSED SAWCUT
DEMOLITION NOTES TO CONTRACTOR:
1. THE CONTRACTOR AND OWNER SHALL COORDINATE WITH
UTILITY SERVICE PROVIDERS FOR TERMINATION OF POWER AND
GAS SERVICES TO THE SITE OR NEW SERVICES. THIS WORK
SHALL BE PERFORMED BY THE UTILITY SERVICE PROVIDER AND
SHALL BE SCHEDULED AS ONE OF THE FIRST ITEMS OF
BUSINESS.
2. ALL SITE FEATURES NOT IDENTIFIED TO BE DEMOLISHED ARE TO
REMAIN AND SHALL BE PROTECTED-IN-PLACE.
3. ALL ITEMS DESIGNATED TO BE REMOVED SHALL BECOME THE
PROPERTY OF THE CONTRACTOR.
4. CONTRACTOR TO FOLLOW ALL RECOMMENDED SAFETY AND
DISPOSAL PROCEDURES INCLUDING BUT NOT LIMITED TO EPA,
TCEQ & OSHA.
5. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL DEBRIS
OFFSITE.
6. BACKFILL ALL VOIDS FROM REMOVED ITEMS WITH STRUCTURAL
FILL MATERIAL PLACED AND COMPACTED PER GEOTECHNICAL
REPORT.
7. WHEN EXISTING SIDEWALK IS CLOSED FOR CONSTRUCTION,
CONTRACTOR SHALL BARRICADE THAT AREA AND PROVIDE SAFE
ALTERNATE PATH FOR PEDESTRIANS WITH PROPER SIGNAGE.
8. CONTRACTOR SHALL REPAIR ANY ITEMS DAMAGED DURING
CONSTRUCTION TO THEIR ORIGINAL CONDITION.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING
POSITIVE DRAINAGE ON SITE DURING ALL CONSTRUCTION
ACTIVITIES.
10. THE CONTRACTOR SHALL ENTER AND EXIT THE SITE THROUGH
EXISTING DRIVEWAY.
11. CONTRACTOR SHALL NOTE ALL UTILITY PLUG LOCATIONS ON
FIELD RECORD DRAWINGS.
EXISTING PAVEMENT TO BE REMOVED
EXISTING CONCRETE SIDEWALK
TO BE REMOVED
EXISTING
BUILDING
AIRLINE RD
124.21'
7.03'
13.82'
15.55'
6.00'
313.93'
51.78'
DEMOLITION PLAN
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
FO
R
BLU
EBEAM
LABELIN
G
/O C
R
Fi le
Pa th
Plot Stamp:
1"
0"
1/29/2024 1:43:21 PM
Au tod es k D oc s:/
/U
HV
_2
0_
UN
R en ov ati on
/P
BK
_2
9 -
U
HV
N W
S
EW
ER
_R
.rv t
N O
R
TH
W
ES
T C
A M
PU
S
- S
EW
ER
R
EN
O
VA
TI
O N
IS
SU
E
FO
R
CO
NS
TR
UC
TI
ON
2024/04/30 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
Author
Checker
E
AS
T
AI
RL
IN
E
RO
AD
VI
CT
OR
IA
, T
EX
AS
AXX
SAMPLE SHEET
No. Description Date
Houston, Texas 77042 t 713 337 8881
TEXAS REGISTERED ENGINEERING
FIRM F-3426
+ A S S O C I A T E S S T R U C T U R A L | C I V I L
9800 Richmond Avenue, Suite 460
D + A PROJECT No. C23-022-00
04/30/2024
C1.00
EXISTING TREE TO BE
REMOVED AND REPLACED.
GENERAL CONSTRUCTION NOTES :
1. ALL UNDERGROUND UTILITIES SHOWN ARE NOT GUARANTEED
TO BE COMPLETE OR DEFINITE, BUT WERE OBTAINED FROM THE
BEST INFORMATION AVAILABLE.
2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES IN THE
FIELD PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER IF
DISCREPANCIES OCCUR.
3. THE LOCATION OF ALL UTILITIES PRESENTED ON THESE
DRAWINGS IS SHOWN IN AN APPROXIMATE WAY ONLY. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION BEFORE
COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE
FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY
HIS FAILURE TO EXACTLY LOCATE AND PRESERVE THESE
UNDERGROUND UTILITIES.
4. CAUTION!!! THERE ARE OVERHEAD POWER LINES IN THE WORK
AREA. CONTRACTOR SHALL FOLLOW CITY, STATE AND FEDERAL
GUIDELINES WHEN WORKING AROUND EXISTING POWER LINES.
5. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS
REQUIRED PRIOR TO STARTING CONSTRUCTION.
6. ALL DIMENSIONS ARE TO FACE OF CURB OR EDGE OF PAVEMENT
UNLESS OTHERWISE NOTED.
7. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR
BUILDING DIMENSIONS.
8. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL
COORDINATE STAGING AND TRAFFIC CONTROL PLANS WITH
OWNER.
9. ALL DISTURBED AREAS NOT TO BE PAVED OR LANDSCAPED
SHALL BE SODDED UPON COMPLETION.
10. CONTRACTOR PERFORMING THE WORK SHALL BE RESPONSIBLE
FOR SECURING ALL UTILITY PERMITS, PRIOR TO INSTALLATION
OF ANY UTILITIES INCLUDING WATER, SEWER, ELECTRIC, CABLE
TELEVISION AND GAS.
SANITARY KEY NOTES:
PROPOSED SANITARY SEWER CLEANOUT.
CONNECT PROPOSED SANITARY SEWER LINE TO EXISTING
MANHOLE.
DRAINAGE KEY NOTES:
PROPOSED 7' TRENCH DRAIN. SEE DETAIL SHEET C5.00.
CONNECT TO EXISTING STORM PIPE
S1
S2
D1
D2
EXISTING
BUILDING
AIRLINE RD
EXISTING
BUILDING
AIRLINE RD
S1 S3
S1
S1
PROP. 155 LF OF 4" SDR
26 SAN. SWR. @ 1.0% S2
D1
PROP 22 LF
8" HDPE STM. SWR.
@1.00%
EXISTING 12" RCP
STM SWR.
EXISTING 6" STM SWR.
EXISTING 18" STM SWR.
D2
EXISTING GRATE INLET
TOP 99.01
12" FL 96.17 (N)
18" FL 95.67 (S)
EXISTING GRATE INLET
TOP 99.01
12" FL 97.01 (S)
- CONC. PAVEMENT -
PROP. 4" SAN
FL 95.38
PROP. 4" FL 92.63
PROP. 4" SAN
FL 94.50
8" FL 97.67
PROP. 123 LF OF 4" SDR
26 SAN. SWR. @ 1.0%
PROP. 148 LF OF 4" SDR
26 SAN. SWR. @ 1.0%
PROP. 111 LF OF 4" SDR
26 SAN. SWR. @ 1.0%
LAYOUT & UTILITY
PLAN
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
FO
R
BLU
EBEAM
LABELIN
G
/O C
R
Fi le
Pa th
Plot Stamp:
1"
0"
1/29/2024 1:43:21 PM
Au tod es k D oc s:/
/U
HV
_2
0_
UN
R en ov ati on
/P
BK
_2
9 -
U
HV
N W
S
EW
ER
_R
.rv t
N O
R
TH
W
ES
T C
A M
PU
S
- S
EW
ER
R
EN
O
VA
TI
O N
IS
SU
E
FO
R
CO
NS
TR
UC
TI
ON
2024/04/30 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
Author
Checker
E
AS
T
AI
RL
IN
E
RO
AD
VI
CT
OR
IA
, T
EX
AS
AXX
SAMPLE SHEET
No. Description Date
Houston, Texas 77042 t 713 337 8881
TEXAS REGISTERED ENGINEERING
FIRM F-3426
+ A S S O C I A T E S S T R U C T U R A L | C I V I L
9800 Richmond Avenue, Suite 460
D + A PROJECT No. C23-022-00
04/30/2024
C2.00
GENERAL CONSTRUCTION NOTES :
1. ALL UNDERGROUND UTILITIES SHOWN ARE NOT GUARANTEED TO
BE COMPLETE OR DEFINITE, BUT WERE OBTAINED FROM THE
BEST INFORMATION AVAILABLE.
2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES IN THE
FIELD PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER IF
DISCREPANCIES OCCUR.
3. THE LOCATION OF ALL UTILITIES PRESENTED ON THESE
DRAWINGS IS SHOWN IN AN APPROXIMATE WAY ONLY. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION BEFORE
COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE
FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY
HIS FAILURE TO EXACTLY LOCATE AND PRESERVE THESE
UNDERGROUND UTILITIES.
4. CAUTION!!! THERE ARE OVERHEAD POWER LINES IN THE WORK
AREA. CONTRACTOR SHALL FOLLOW CITY, STATE AND FEDERAL
GUIDELINES WHEN WORKING AROUND EXISTING POWER LINES.
5. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS
REQUIRED PRIOR TO STARTING CONSTRUCTION.
6. ALL DIMENSIONS ARE TO FACE OF CURB OR EDGE OF PAVEMENT
UNLESS OTHERWISE NOTED.
7. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR
BUILDING DIMENSIONS.
8. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL
COORDINATE STAGING AND TRAFFIC CONTROL PLANS WITH
OWNER.
9. ALL DISTURBED AREAS NOT TO BE PAVED OR LANDSCAPED
SHALL BE SODDED UPON COMPLETION.
10. CONTRACTOR PERFORMING THE WORK SHALL BE RESPONSIBLE
FOR SECURING ALL UTILITY PERMITS, PRIOR TO INSTALLATION OF
ANY UTILITIES INCLUDING WATER, SEWER, ELECTRIC, CABLE
TELEVISION AND GAS.
SAWCUT NOTES:
1. SAWCUT 2" MINIMUM DEPTH, EXPOSE AND CLEAN EXISTING
REINFORCING STEEL.
2. IF NO REINFORCING STEEL EXISTS, #5 HORIZONTAL DOWELS, 24"
LONG, GRADE 60, SHALL BE DRILLED AND EMBEDDED 12" INTO
THE CENTER OF EXISTING CONCRETE WITH EPOXY. AIR BLOW TO
CLEAN HOLE BEFORE EPOXY.
3. ALL REINFORCING STEEL SHALL BE PLACED 3" CLEAR
(2" ABSOLUTE MINIMUM) FROM EDGE OF CONCRETE.
LEGEND
PROPOSED CONCRETE PAVEMENT
SAWCUT LINE
PROPOSED CONCRETE SIDEWALK
PAVEMENT KEY NOTES:
PROPOSED ASPHALT PAVEMENT REPLACEMENT. MATCH
EXISTING PAVING ELEVATIONS.
PROPOSED CONCRETE SIDEWALK REPLACEMENT. MATCH
EXISTING PAVING ELEVATIONS.
P1
P2
EXISTING
BUILDING
AIRLINE RD
EXISTING
BUILDING
AIRLINE RD
- CONC. PAVEMENT -
P1
P2
P2
P1 P1
P2
PAVING PLAN
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
FO
R
BLU
EBEAM
LABELIN
G
/O C
R
Fi le
Pa th
Plot Stamp:
1"
0"
1/29/2024 1:43:21 PM
Au tod es k D oc s:/
/U
HV
_2
0_
UN
R en ov ati on
/P
BK
_2
9 -
U
HV
N W
S
EW
ER
_R
.rv t
N O
R
TH
W
ES
T C
A M
PU
S
- S
EW
ER
R
EN
O
VA
TI
O N
IS
SU
E
FO
R
CO
NS
TR
UC
TI
ON
2024/04/30 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
Author
Checker
E
AS
T
AI
RL
IN
E
RO
AD
VI
CT
OR
IA
, T
EX
AS
AXX
SAMPLE SHEET
No. Description Date
Houston, Texas 77042 t 713 337 8881
TEXAS REGISTERED ENGINEERING
FIRM F-3426
+ A S S O C I A T E S S T R U C T U R A L | C I V I L
9800 Richmond Avenue, Suite 460
D + A PROJECT No. C23-022-00
C3.00
LEGEND
INLET PROTECTION BARRIER
(STAGE II)
PROPOSED SILT SOCK
IPB
GENERAL CONSTRUCTION NOTES
1. ALL UNDERGROUND UTILITIES SHOWN ARE NOT GUARANTEED TO BE
COMPLETE OR DEFINITE, BUT WERE OBTAINED FROM THE BEST
INFORMATION AVAILABLE.
2. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES IN THE FIELD
PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER IF DISCREPANCIES
OCCUR.
3. THE LOCATION OF ALL UTILITIES PRESENTED ON THESE DRAWINGS IS
SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATION BEFORE COMMENCING WORK. HE
AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES
WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE
AND PRESERVE THESE UNDERGROUND UTILITIES.
4. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS REQUIRED
PRIOR TO STARTING CONSTRUCTION.
5. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL COORDINATE
STAGING AND TRAFFIC CONTROL PLANS WITH OWNER.
6. ALL DISTURBED AREAS SHALL BE SODDED UPON COMPLETION IF NOT
TO BE PAVED OR LANDSCAPED.
7. CONTRACTOR SHALL UTILIZE TEMPORARY EROSION CONTROL MAT OR
EQUAL DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR
ENSURING WATER QUALITY CONTROLS MEET TCEQ STANDARDS.
STABILIZED CONSTRUCTION ACCESSSC
SWPPP CONSTRUCTION NOTES :
1. ALL AREAS WHERE EXISTING VEGETATION AND GRASS COVER HAVE
BEEN BARED BY CONSTRUCTION SHALL BE ADEQUATELY BLOCK
SODDED OR HYDROMULCHED AND WATERED UNTIL GROWTH IS
ESTABLISHED. IN DEVELOPED AREAS WHERE GRASS IS PRESENT,
BLOCK SOD WILL BE REQUIRED. BARED AREAS SHALL BE SEEDED OR
SODDED WITHIN 14 CALENDAR DAYS OF LAST DISTURBANCE.
2. APPROVED EROSION CONTROL MEASURES MUST BE INSTALLED
DURING THE ENTIRE TIME THAT EARTH HAS BEEN BARED BY
CONSTRUCTION AND SHALL STAY IN PLACE UNTIL ACCEPTABLE
VEGETATIVE GROWTH IS ESTABLISHED AFTER CONSTRUCTION IS
COMPLETE AND THEN REMOVED BY CONTRACTOR.
3. ALL EROSION CONTROL MEASURES SHALL BE CLEANED AFTER EVERY
RAIN.
4. CONTRACTOR SHALL ENTER AND EXIT SITE FROM EXISTING DRIVEWAY.
EXISTING
BUILDING
OUR LADY OF VICTORY SCHOOL
CATHOLIC DIOCESE OF VICTORIA
AIRLINE RD
LOT 29
LOT 1
LOT 29
LOT 1
LOT 29
SC
IPB
IPB
EXISTING
BUILDING
OUR LADY OF VICTORY SCHOOL
CATHOLIC DIOCESE OF VICTORIA
AIRLINE RD
LOT 29
LOT 1
LOT 29
LOT 1
LOT 29IPB
IPB
SWPPP PLAN
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
FO
R
BLU
EBEAM
LABELIN
G
/O C
R
Fi le
Pa th
Plot Stamp:
1"
0"
1/29/2024 1:43:21 PM
Au tod es k D oc s:/
/U
HV
_2
0_
UN
R en ov ati on
/P
BK
_2
9 -
U
HV
N W
S
EW
ER
_R
.rv t
N O
R
TH
W
ES
T C
A M
PU
S
- S
EW
ER
R
EN
O
VA
TI
O N
IS
SU
E
FO
R
CO
NS
TR
UC
TI
ON
2024/04/30 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
Author
Checker
E
AS
T
AI
RL
IN
E
RO
AD
VI
CT
OR
IA
, T
EX
AS
AXX
SAMPLE SHEET
No. Description Date
Houston, Texas 77042 t 713 337 8881
TEXAS REGISTERED ENGINEERING
FIRM F-3426
+ A S S O C I A T E S S T R U C T U R A L | C I V I L
9800 Richmond Avenue, Suite 460
D + A PROJECT No. C23-022-00
C4.00
SITE DETAILS
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
FO
R
BLU
EBEAM
LABELIN
G
/O C
R
Fi le
Pa th
Plot Stamp:
1"
0"
1/29/2024 1:43:21 PM
Au tod es k D oc s:/
/U
HV
_2
0_
UN
R en ov ati on
/P
BK
_2
9 -
U
HV
N W
S
EW
ER
_R
.rv t
N O
R
TH
W
ES
T C
A M
PU
S
- S
EW
ER
R
EN
O
VA
TI
O N
IS
SU
E
FO
R
CO
NS
TR
UC
TI
ON
2024/04/30 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
Author
Checker
E
AS
T
AI
RL
IN
E
RO
AD
VI
CT
OR
IA
, T
EX
AS
AXX
SAMPLE SHEET
No. Description Date
Houston, Texas 77042 t 713 337 8881
TEXAS REGISTERED ENGINEERING
FIRM F-3426
+ A S S O C I A T E S S T R U C T U R A L | C I V I L
9800 Richmond Avenue, Suite 460
D + A PROJECT No. C23-022-00
C5.00
GENERAL DEMOLITION NOTES
1. DEMOLITION PLANS INDICATE SOME OF THE SCOPE-OF-WORK INVOLVED FOR THE DEMOLITION
PHASE OF THIS PROJECT. CONTRACTOR SHALL REVIEW ALL SHEETS FOR ADDITIONAL
DEMOLITION SCOPE.
2. CONTRACTOR SHALL VERIFY EXISTING SITE AND BUILDING CONDITIONS AND DIMENSIONS IN
THE FIELD PRIOR TO DEMOLITION ACTIVITIES AND WORK.
3. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES IN WRITING.
4. CONTRACTOR SHALL NOTIFY ARCHITECT AND OWNER OF ANY POSSIBLE ASBESTOS
CONTAINING MATERIALS DISCOVERED BEFORE PROCEEDING WITH WORK, PROTECT INTERIOR
CONSTRUCTION TO REMAIN DURING DEMOLITION AND CONSTRUCTION.
5. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS BEFORE COMMENCING WORK.
6. AFTER AWARD OF THE CONTRACT, CHANGE ORDER REQUESTS FOR ADDITIONAL MONEY WILL
NOT BE APPROVED IF THE WORK COULD HAVE BEEN ANTICIPATED DURING A SITE VISIT BY THE
CONTRACTOR.
7. CONTRACTOR SHALL NOT SCALE DRAWINGS.
8. CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY SHORING, TEMPORARY BRACING,
AND OR TEMPORARY SUPPORTS AS REQUIRED TO MAINTAIN STRUCTURAL INTEGRITY OF
EXISTING STRUCTURE TO REMAIN AND OR EXISTING BUILDING ELEMENTS TO REMAIN.
9. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES PRIOR TO
DEMOLITION ACTIVITIES AND WORK.
10. CONTRACTOR SHALL REMOVE TRASH AND DEBRIS REGULARLY AS NECESSARY TO ELIMINATED
INTERFERENCE WITH ROADS, STREET, WALKS, AND ALL OTHER ADJACENT FACILITIES.
11. CONTRACTOR SHALL REPAIR, REPLACE, OR PATCH EXISTING BUILDINGS, DRIVEWAYS,
SIDEWALKS, CANOPIES, AND OR PARKING AREAS DAMAGED, MODIFIED, AND OR DISTURBED BY
DEMOLITION WORK AT NO COST TO THE OWNER.
12. ALL EXISTING EQUIPMENT THAT REMAINS SHALL BE PROTECTED DURING DEMOLITION AND OR
CONSTRUCTION TO PREVENT DAMAGE. ANY DAMAGE TO REMAINING EXISTING EQUIPMENT
SUSTAINED DURING DEMOLITION AND OR CONSTRUCTION SHALL BE EQUIVALENTLY REPLACED
OR EQUIVALENTLY REPAIRED AT NO COST TO THE OWNER.
13. CONTRACTOR SHALL PROVIDE TRAFFIC HANDLING MEASURES TO PROTECT THE GENERAL
PUBLIC AT ALL TIMES, AS NECESSARY AND AS REQURED BY AUTHORITIES HAVING
JURISDICTION.
14. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY
AUTHORITIES HAVING JURISDICTION. PROVIDE TEMPORARY SERVICES DURING INTERRUPTIONS
TO EXISTING UTILITIES, AS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.
15. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED, RELOCATED, OR ABANDONED,
PROVIDE BYPASS CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE BEFORE PROCEEDING
WITH DEMOLITION.
16. CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES INCLUDING BUT NOT LIMITED TO THE
FOLLOWING: ELECTRIC, GAS, WATER, TELEPHONE, STORM SEWER, AND SANITARY SEWER FOR
FIELD LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITY LINES. PRIOR TO
COMMENCEMENT OF ANY DEMOLITION WORK, CONTRACTOR SHALL IDENTIFY ALL ELECTRICAL
CIRCUITS SERVICING THE AREA INVOLVED WITH THIS DEMOLITION. THOSE CIRCUITS SHALL
THEN BE LOCKED OUT AND TAGGED OUT IF THEY DO NOT SERVICE ANY OF THE REMAINING
BUILDING. THOSE CIRCUITS WHICH ARE IDENTIFIED TO SERVICE BOTH THE AREA TO BE
DEMOLISHED AND THE REMAINING BUILDING SHALL BE SPLIT SO AS TO KILL ALL ELECTRICAL
POWER TO THE AREA TO BE DEMOLISHED WHILE MAINTAINING POWER TO THE REMAINDER OF
THE BUILDING.
17. CONTRACTOR SHALL RELOCATE UTILITIES AND EQUIPMENT AS REQUIRED TO ACCOMMODATE
NEW HVAC, ELECTRICAL, PLUMBING, AND TECHNOLOGY REQUIREMENTS FOR NEW WORK.
18. PROTECT EXISTING SITE ELEMENTS AND EXISTING LANDSCAPING TO REMAIN. PROTECTION
SHALL INCLUDE BUT NOT BE LIMITED TO EXISTING TREES AND OTHER EXISTING VEGETATION
INDICATED TO REMAIN IN PLACE AGAINST UNNECESSARY CUTTING, BREAKING, OR SKINNING OF
ROOTS, SKINNING OR BRUISING OF BARK, SMOTHERING OF TREES BY STOCKPILING
CONSTRUCTION MATERIAL OR EXCAVATED MATERIAL WITHIN DRIP LINES.
19. CONTRACTOR SHALL REGRADE AND HYDROMULCH AREAS AFFECTED BY DEMOLITION.
20. OWNER HAS RIGHT OF FIRST REFUSAL OF ALL ITEMS REMOVED AS PART OF THE SCOPE OF
WORK, WHETHER IDENTIFIED AS SALVAGE OR NOT.
21. NOTIFY THE BUILDING OWNER OF ANY MATERIALS, FIXTURES, ETC. TO BE REMOVED THAT ARE
DEEMED SALVAGEABLE. TURN OVER ANY REQUESTED ITEMS TO THE BUILDING OWNER IN
GOOD AND CLEAN CONDITION.
22. ALL FURNITURE WILL BE REMOVED OR RELOCATED BY THE OWNER AS NECESSARY PRIOR TO
THE DEMOLITION WORK OF THIS PROJECT. CONTRACTOR SHALL COORDINATE WITH OWNER AS
REQUIRED.
23. REMOVE EXISTING CONSTRUCTION TO THE EXTENT INDICATED ON THE DRAWINGS. SHOULD
ANY DAMAGE OCCUR TO ANY EXISTING CONSTRUCTION TO REMAIN, THE CONTRACTOR SHALL
REPAIR THE DAMAGE TO MATCH EXISTING AND OR ADJACENT CONSTRUCTION AT NO COST TO
THE OWNER.
24. MAINTAIN ANY AND ALL EXISTING FIRE-RATED ASSEMBLIES THAT ARE TO REMAIN, AND THEIR ASSOCIATED FIRE-RATINGS, INCLUDING BUT NOT LIMITED TO ALL ASSOCIATED EXISTING FIRE-
RATED OPENINGS, ALL ASSOCIATED EXISTING FIRE-RATED PENETRATIONS, AND ALL
ASSOCIATED EXISTING FIRE-RATED FIRESTOPPING CONDITIONS.
25. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT CONFLICT
WITH THE INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, DETERMINE THE NATURE AND
EXTENT OF THE CONFLICT AND NOTIFY THE ARCHITECT IMMEDIATELY FOR RESOLUTION.
26. REMOVE, PATCH, AND REPAIR ALL ABANDONED ROOF PENETRATIONS RESULTING FROM WORK.
27. SAW-CUT AND REMOVE EXISTING FLOOR FINISHES AND FLOOR SLAB AS REQUIRED TO INSTALL
NEW FIXTURES, ITEMS, AND OR DEVISES FOR ALL SCOPE-OF-WORK PERTAINING TO NEW
MECHANICAL WORK, NEW PLUMBING UTILITIES, NEW PLUMBING WORK, NEW ELECTRICAL
WORK, AND NEW TECHNOLOGY WORK. SPLICE NEW REINFORCING BARS DOWELLED INTO
EXISTING CONCRETE AND PROVIDE NEW VAPOR RETARDER AND NEW CONTINUOUS
WATERSTOPS AT JOINT BETWEEN NEW CONCRETE FLOOR SLAB AND EXISTING CONCRETE
FLOOR SLAB. PATCH WITH NEW 3,500 PSI MINIMUM CONCRETE AND PREPARE FLOOR,
INCLUDING NEW CONCRETE, TO RECEIVE NEW FLOOR FINISHES. COORDINATE WITH
STRUCTURAL.
28. EXISTING WALLS (OR PORTIONS OF WALLS) TO BE REMOVED SHALL BE CUT FLUSH WHERE
INTERSECTING WITH WALLS TO REMAIN. REMAINING WALLS TO BE PATCHED AND FINISHED
SMOOTH.
29. NEW OPENING TO BE CUT IN EXISTING WALLS SHALL BE SAW-CUT AT LOCATIONS INDICATED TO THE HEIGHT AND WIDTH INDICATED. NEW LINTELS SHALL BE INSTALLED TO SUPPORT EXISTING
WALL CONSTRUCTION ABOVE AS INDICATED ON THE DRAWINGS, OR IF NOT INDICATED, AS
REQUIRED FOR NEW WALL CONSTRUCTION PER STRUCTURAL DRAWINGS. COORDINATE
LOCATIONS OF ALL NEW OPENINGS IN EXISTING WALLS AND PARTITIONS WITH ARCHITECTURAL
PLANS.
30. WHERE EXISTING WALL OPENINGS ARE TO BE NEWLY CLOSED-OFF, REMOVE ANY EXISTING
OPENING FRAME AND PATCH AND REPAIR EXISTING WALL TO MATCH EXISTING ADJACENT
MATERIALS AND FINISHES, UNLESS NOTED OTHERWISE.
31. WHERE EXISTING INTERIOR WALLS ARE REPLACED OR REMOVED, REMOVE MEPT SYSTEMS
BACK TO PANEL, OR MECHANICAL ROOM, OR FARTHEST POSSIBLE POINT WITHOUT DISTURBING
EXISTING CONSTRUCTION. REMOVE EXISTING MECHANICAL EQUIPMENT, RELOCATE POWER
PER MEPT DRAWINGS
32. REFER TO MEPT DRAWINGS FOR DEMOLITION OF MEPT SYSTEMS. IDENTIFY WORK REQUIRED
BY THIS CONTRACTOR WHICH MAY AFFECT DEMOLITION AND OR REPAIRS OF ARCHITECTURAL
ELEMENTS. COORDINATE WITH RELATED SUBCONTRACTORS THE EXTENT OF ALL DEMOLITION
WORK.
33. PATCH FLOORS, WALLS CEILINGS WHICH REMAIN AT LOCATIONS WHERE PIPES, CONDUITS, ETC.
ARE REMOVED AS REQUIRED TO MATCH EXISTING CONDITIONS OR TO RECEIVE NEW FINISHES.
34. WHERE EXISTING FINISH FLOOR IS REMOVED, PREPARE FLOOR SURFACE TO RECEIVE NEW
FLOORING.
35. ALL DASHED LINES ARE DEMOLITION LINES U.N.O.
EAST AIRLINE ROAD
A N.I.C.
B N.I.C.
C N.I.C.
D N.I.C.
COURTYARD
N.I.C.
EXTENTS OF SITE DEMOLITION, RE: CIVIL DRAWINGS
RE: C1.00 FOR TRENCHING DIMENSIONS
OUR LADY
OF VICTORY
CATHEDRAL
N.I.C.
NOT IN CONTRACT
DEMOLITION LEGEND
EXTENTS OF DEMOLITION
IN SCOPE
N
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
KEY PLAN
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
PLAN TRUE
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
NORTH:
4/30/2024 10:13:04 AM
A u to d e sk
D o cs
/U
H V
U
N R e n o va tio n /P
B K
U H
V N
W S
E W
E R
R
.r vt
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
AD100
SITE DEMOLITION
PLAN
04/30/2024 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
K. BRITTAIN
C. WHITTINGSTALL
E A
S T
A
IR
L
IN
E R
O A
D
V
IC
T O
R
IA
T
E X
A S
A D
S
IT
E D
E M
O L
IT
IO
N P
L A
N
04/30/2024
1" = 30'-0"
6 DEMOLITION SITE PLAN
PLAN
NORTH
NORTH
A
N.I.C.
B
N.I.C.
C
N.I.C.
D
N.I.C.
N .I
.C
EXIST. CANOPY
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
BUILDING ENVELOPE
BEAM
T 210-638-7200
REF.
NPQ
4.5
DEMO EXISTING FLOOR FINISH LIMITS OF FLOOR FINISH DEMO
LIMIT OF TRENCHING FOR NEW
SEWER CONNECTION
PARTIALLY DEMO EXISTING
FLOOR FINISH FOR
TRENCHING. VERIFY IN
FIELD.
CONTRACTOR TO PROVIDE
IAQ(INDOOR AIR QUALITY)
MEASURES AT ALL PHASES
OF CONSTRUCTION
PREPARE ARE FOR TRENCH DRAIN
RE: CIVIL DRAWINGS.
EXISTING
WOMEN'S
A101
EXISTING MEN'S
A100
V.I.F.
10'-4 3/8"
/8
APPROXIMATE LENGTH OF
EXISTING SEWER LINE LOCATION.
CONTRACTOR TO VERIFY.
RE: C1.00 FOR TRENCHING
DIMENSIONS
RE:2/A102 FOR INTENT
OF DESIGN
CONTRACTOR TO
DEMOLISH PORTION
OF FLOOR FINISH AND
WALL FINISH IF
NECESSARY
CONTRACTOR TO
DEMOLISH PORTION
OF FLOOR FINISH AND
WALL FINISH IF
NECESSARY
1439 SF
KINESIOLOGY
859 SF
CORRIDOR
EXISTING MEN'S
A100
EXISTING WOMEN'S
A101
100 SF
TOILET
PARTIALLY DEMO EXISTING
CEILING
FOR NEW DOOR FRAMING
PARTIALLY DEMO EXISTING
CEILING
FOR NEW DOOR FRAMING
AB
3'-4"
V.I.F.
8'-9 3/4"
V.I.F.
4'-6"
SALVAGE
EXISTING
APPLIANCES
PARTIALLY
DEMO EXISTING
COUNTERTOP.
A10220
EXISTING PLUMBING
FIXTURES AND ITS
CONNECTION TO
REMAIN AND
PROTECT IN ALL
PHASES OF
CONSTRUCTION.
CONTRACTOR TO
PROVIDE
IAQ(INDOOR AIR
QUALITY)
MEASURES.
02 41 00.S9
N
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
KEY PLAN
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
PLAN TRUE
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
NORTH:
4/30/2024 10:13:06 AM
A u to d e sk
D o cs
/U
H V
U
N R e n o va tio n /P
B K
U H
V N
W S
E W
E R
R
.r vt
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
AD101
ENLARGED
DEMOLITION PLANS
04/30/2024 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
K. BRITTAIN
C. WHITTINGSTALL
E A
S T
A
IR
L
IN
E R
O A
D
V
IC
T O
R
IA
T
E X
A S
A D
E N
L A
R G
E D
D E
M O
L
IT
IO
N
P L
A N
S
04/30/2024
A
N.I.C.
B
N.I.C.
C
N.I.C.
D
N.I.C.
N .I
.C
EXIST. CANOPY
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
BUILDING ENVELOPE
BEAM
T 210-638-7200
1/4" = 1'-0"
06 ENLARGED DEMOLITION FLOOR PLAN
1/4" = 1'-0"
03 ENLARGED DEMOLITION REFLECTED CEILING PLAN
1/4" = 1'-0"
24 ENLARGED DEMOLITION FLOOR PLAN
PLAN
NORTH
NORTH
PLAN
NORTH
NORTH
PLAN
NORTH
NORTH
LMNPQRS
4.5
E X
I S
T I N
G
T O
R
E M
A I N
C O
V E R
E D
S L A B
COURTYARD
N.I.C.
UNIT A
EXISTING COLUMN
(FIELD VERIFY)
EXISTING COLUMN
(FIELD VERIFY)SCAN THE SLAB FOR
GRADE BEAM ALONG
COLUMN GRID LINE
APPROXIMATE
EXTENT OF NEW
TRENCH, SEE
PLUMBING AND
ARCHITECTURE
DWGS FOR EXACT
LOCATIONS
S401
S401
ABOVE
S401
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
N
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
KEY PLAN
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
PLAN TRUE
BUILDING NUMBER
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
NORTH:
1233263
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
ISSUED FOR CONSTRUCTION
04/30/24
23059904/30/2024
4/26/2024 11:59:55 AM
C :\U se rs
\M ar is el a\ D oc um en ts
\3
3_ U
H V
P ha se
R en ov
C en tr al
S
_m ar is el am
1.
rv t
S104
ENLARGED FIRST
FLOOR FRAMING
PLAN - AREA A
UNIVERSITY OF HOUSTON VICTORIA
Author
Checker
E A
S T
A
IR
LI
N
E R
O A
D V ic to ria , T ex as
S
E N
L A
R G
E D
F
IR
S T
F L
O O
R F
R A
M
IN
G P
L A
N
A R
E A
A
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887 north
SCALE: 3/32" = 1'-0"
1 PARTIAL FIRST FLOOR FRAMING PLAN - AREA A
A
N.I.C.
B
N.I.C.
C
D
N .I
.C
EXIST. CANOPY
A
A
H B
B
C
C
D
D
E
E
F
F
G
G
H.1
H.1
4.5
1' -0
N.I.C.
OPEN
AREA
S
UNIT BUNIT B
NEW EXTERIOR COURTYARD
APPROXIMATE EXTEND OF
NEW TRENCH, SEE PLUMBING
AND ARCHITECTURE
DRAWINGS FOR EXACT
LOCATIONS
S401
LEGEND
- INDICATES NOT IN CONTRACT (N.I.C.)
- INDICATES EXISTING TO REMAIN,
AREA OF NEW WORK.
- INDICATES THE EXTENT OF
TRENCHING FOR NEW SEWER
CONNECTION.
north
SCALE: 3/32" = 1'-0"
1 PARTIAL FIRST FLOOR FRAMING PLAN - AREA B
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
N
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
KEY PLAN
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
PLAN TRUE
BUILDING NUMBER
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
NORTH:
1233263
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
ISSUED FOR CONSTRUCTION
04/30/24
23059904/30/2024
4/26/2024 11:59:56 AM
C :\U se rs
\M ar is el a\ D oc um en ts
\3
3_ U
H V
P ha se
R en ov
C en tr al
S
_m ar is el am
1.
rv t
S105
PARTIAL FIRST
FLOOR FRAMING
PLAN - AREA B
UNIVERSITY OF HOUSTON VICTORIA
Author
Checker
E A
S T
A
IR
LI
N
E R
O A
D V ic to ria , T ex as
S
P A
R T
IA
L
F
IR
S T
F L
O O
R F
R A
M
IN
G P
L A
N
A R
E A
B
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
A
N.I.C.
B
N.I.C.
C
D
N .I
.C
EXIST. CANOPY
PLAN NOTES:
1. SEE ARCHITECTURAL PLAN FOR NEW WORK.
AND MEP SERIES DWGS
VARIES, SEE PLAN
EXIST TOC EL=
-0'-0"
SAWCUT EXISTING
CONCRETE SLAB
AS REQD
FILL VOID W/ 3,000
PSI CONCRETE
IF PLASTIC SHEET VAPOR
RETARDER MEMBRANE IS
PRESENT, LAP 6" W/ NEW
10 MIL VAPOR RETARDER
AND TAPE SEAMS
BACKFILL & COMPACT WITH
EXCAVATED MATERIALS
T O
C
B E L O
W
BAR BEYOND
F
IE
L D
V E R
IF
Y
E X
IS
T S
L A B
T H
IC
K N E S S
DRILL 5/8"Ø BY 6" DEEP
HOLES AND NO LARGER,
CLEAN W/ COMP AIR AND
WIRE BRUSH. INSTALL
DOWELS W/ EPOXY
SEE PLUMBING OR OTHER
DISCIPLINE DWGS FOR PIPE
LOCATION AND ELEVATION
STOP SAWCUTS 6" SHORT OF GRADE
BEAMS WHERE PRESENT. LOCATE
GRADE BEAMS & POST TENSION
CABLES WITH GPR SCAN
(3)-#4 @ 12" OC MAX
#4 @ 12" OC MAX
STAGGER SIDES
THIS DETAIL APPLIES ONLY
IF GRADE SUPPORTED.
EXTEND NEW VAPOR
BARRIER AT LEAST 6"
UNDER THE EXISTING SLAB
EVEN IF EXISTING VAPOR
BARRIER IS NOT PRESENT
T H
IC
K N E S S
S L A B
B E A M
D E P T H
M
IN
N E W
C O
N C R
E T
B
L
W
B
T T O
M
O F P
IP
E
3'-0"
NEW PIPE
DRILL 8" & EPOXY
EMBED (2) #7 x
1'-4" 1'-
6"
EACH SIDE OF PIPE
CUT OUT & REMOVE BOTTOM
OF BEAM AND REBAR
ELEVATION
NOTES:
1. DETAIL FOR WHEN PIPE PENETRATIONS OCCUR IN THE
BOTTOM 6" OF AN EXISITING CONCRETE GRADE BEAM.
2. USE THIS DETAIL ONLY WHEN OPTIONS OF RAISING OR
LOWERING THE PIPE HAVE BEEN EXHAUSTED.
SECTION
A L L O
W E D
C O
R E H
O L E S
P
IP
P
N E T R
A T
IO
N
BEAM BOTTOM BARS
DO NOT CUT BARS
UNLESS ABSOLUTELY
NECESSARY,
SEE "ELEVATION"
BEAM TOP BARS
DO NOT CUT BARS
FILL BEAM VOID WITH
3000 PSI CONCRETE
THIS DETAIL APPLIES ONLY
IF GRADE SUPPORTED.
EXISTING
CONCRETE
SLAB AND
BEAM TO
REMAIN
CORE HOLE WHERE
APPLICABLE
6"
DO NOT CUT BEAM
TRENCH SLAB TO
BE REMOVED
FIELD VERIFY
1'-0"
F
IE
L D
V E R
IF
Y
4'-0" 3'-1 1/8"
Q
11 1/2" 2'-1 5/8"
BLDG LINE
BOS EL=
10'-0"
(FV)
EXISTING STEEL
LINTEL (FIELD VERIFY) BLDG LINE
3'-5"
2"
(FV)
5 1/2"
6"
1' -7
REMOVE ONLY
ENOUGH BRICK TO
INSTALL & WELD
CEILING
SOFFIT
NEW L6x6x3/8
TYP
3/16
S401
EXIST CONC
COLUMN
3/16
EXIST ROOFING
EXIST
STL BM
L5x5x3/8 x0'-8" LG
EXIST
ROOFJSTS401
TOS EL=
15'-0"
(FV)
L5x3x1/4
L2x2x3/16
Q
4.5
(FV)
11 1/2"
4"
BLDG LINE
SEALANT AS
SPECIFIED
ALL AROUND
COVER PL
1/2"x6"x9" T&B
3/16
L5x3x1/4 xCONT (LLV)
3/4"
EXISTING CONC
COL (12x12)
L6x6x3/8 x10" W/
(2)-1/2"Ø x 6" HILTI
KWIK BOLT TZ2
CARBON STEEL
ANCHORS
REMOVE ONLY ENOUGH
BRICK TO INSTALL &
WELD
S401
HSS6x3
1 1/2" 3 1/2"
3"
1 1 /2
1 1/4"Ø
STD PIPE
3/8" PL
1/4"Ø x 2" ZINC
CLEVIS PIN WITH
COTTER PIN, TYP
3/16
1' -0
9"
3" 3" 3"
L5x3x1/4
CUT OUT
FOR HSS
3/16
TYP
SEALANT AS
SPECIFIED
ALL AROUND
COVER (2)-
PL1/2"x6"x9"
JOINT AT
COVER PL
TYP
3/16
HSS, SEE PLAN
Q 3/4"
(FV)
11 1/2"
BLDG LINE
SEALANT AS
SPECIFIED
ALL AROUND
COVER PL
1/2"x6"x9" T&B
3/16
L5x3x1/4 xCONT (LLV)
REMOVE ONLY ENOUGH
BRICK TO INSTALL &
WELD
C6 HANGER
L6x6 x0'-8"
FACE OF BRICK
BELOW
4'-0"3'-1 1/8"
Q
11 1/2"2'-1 5/8"
BLDG LINE
BOS EL=
10'-0"
(FV)
EXISTING STEEL LINTEL
(FIELD VERIFY)
BLDG LINE
TOS EL=
15'-0"
(FV)
3'-5"
2"
(FV)
5 1/2"
6"
1' -7
REMOVE ONLY
ENOUGH BRICK TO
INSTALL & WELD
CEILING
SOFFIT
NEW
L6x6x3/8
S401
EXIST ROOFING
EXIST STL BM
L5x5x3/8 x0'-8" LG
EXIST
ROOFJST S401
C6x8.2 x3'-0"
3/16
TYP
3/16
1-12
TYP
1-12
TYP
Q
4.5
HSS6x3x3/16
H S S x x
HSS6x3x3/16
L2x2x3/16
L2x2x3/16
L2x2x3/16 L x x
A B
O V
E
1' -1
1/
1' -1
1/
S401
L6x6 (ABOVE)
C6 HANGER
3/16
5 1/2" 6"
S401
S401
S401
4'-0"
L x x 1/
L L V
B
E L O
W
D E C K
S P A N
L
1/ x
1/ x 1/
A
B O
V E
NOTE:
1. DECK SHALL BE 1/8" STEEL PLATE.
2. SLOPE STEEL STRUCTURE 1/4" PER
FOOT AWAY FROM THE BUILDING.
REFER TO ARCHITECTURAL DRAWING
FOR ALTERNATE CANOPY OPTION
Q
4.5
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
BUILDING NUMBER
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
1233263
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
ISSUED FOR CONSTRUCTION
04/30/24
23059904/30/2024
4/26/2024 11:59:59 AM
C :\U se rs
\M ar is el a\ D oc um en ts
\3
3_ U
H V
P ha se
R en ov
C en tr al
S
_m ar is el am
1.
rv t
S401
SECTIONS AND
DETAILS
UNIVERSITY OF HOUSTON VICTORIA
Author
Checker
E A
S T
A
IR
LI
N
E R
O A
D V ic to ria , T ex as
S
S E
C T
IO
N
S A
N D
D E
T A
IL
S
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
NO SCALE
1 DETAIL AT SAW CUT SLAB ON GRADE
NO SCALE
2 PIPE PENETRATION AT EXISTING CONCRETE BEAM
SCALE: 3/4" = 1'-0"
4 HEADER/SOFFIT SECTION
SCALE: 3/4" = 1'-0"
7 PLAN DETAIL
SCALE: 1" = 1'-0"
6 DETAIL
SCALE: 1 1/2" = 1'-0"
8 DETAIL
SCALE: 3/4" = 1'-0"
9 PLAN DETAIL
SCALE: 3/4" = 1'-0"
5 HEADER/SOFFIT SECTION
SCALE: 3/8" = 1'-0"
3 PLAN DETAIL AT RECESSED ENTRY
E. AIRLINE ROAD
EXISTING PARKING LOT
108,000 SF
EXISTING PARKING LOT
127,000 SF
EXISTING DRIVEWAY
APRON
EXISTING DRIVEWAY
APRON
E X
IS
T
IN
G
S
ID
E W
A
LK
EXISTING
COVERED
SLAB
EXISTING SIDEWALK
EXISTING SIDEWALK
EXISTING SIDEWALK
EXISTING PARKING LOT
C O
U R
T Y
A R
D
PATCH AND REPAIR AREAS WHERE TRENCHING OCCURS AND MATCH EXISTING,
RE: CIVIL DWGS.
A N.I.C.
B N.I.C.
C N.I.C.
D N.I.C.
COURTYARD
N.I.C.
OUR LADY
OF VICTORY
CATHEDRAL
N.I.C.
PATCH AND
REPAIR AREAS
WHERE
TRENCHING
OCCURS AND
MATCH EXISTING,
RE: CIVIL DWGS.
GENERAL ARCH SITE PLAN NOTES
1. REFER TO CIVIL DOCUMENTS
2. COORD. ALL SPOT ELEVATIONS AND DIMENSIONS WITH CIVIL, LANDSCAPE, AND
OR STRUCTURAL DOCUMENTS
3. PROVIDE AND INSTALL POSITIVE DRAINAGE AWAY FROM ALL BUILDINGS OF 1 %
MINIMUM, 2 % MAXIMUM AT ALL EXTERIOR PAVED PEDESTRIAN AREAS,
INCLUDING BUT NOT LIMITED TO, SIDEWALKS, PATIOS, STAIRS, PAVING, U.N.O.
4. PROVIDE AND INSTALL POSITIVE DRAINAGE AWAY FROM ALL BUILDINGS OF 5 %
FOR A HORIZ. DISTANCE OF 10 FEET AT ALL EXTERIOR NON-PAVED AREAS U.N.O
5. REFER TO CIVIL DOCUMENTS FOR CONCRETE SIDEWALK EXPANSION JOINTS AND
CONCRETE SIDEWALK CONTROL JOINTS
6. VERIFY AND CONFIRM ALL JOINT LAYOUTS AT ALL CONCRETE SIDEWALKS WITH
ARCH. PRIOR TO POURING OF CONCRETE
7. PROVIDE AND INSTALL CONCRETE SIDEWALK EXPANSION JOINTS AT AREAS NOT
SPECIFICALLY INDICATED AT 50 FEET ON-CENTER MAX. U.N.O.
8. PROVIDE AND INSTALL CONCRETE SIDEWALK CONTROL JOINTS AT AREAS NOT
SPECIFICALLY INDICATED AT DISTANCES EQUIVALENT TO SIDEWALK WIDTH, BUT
NOT TO EXCEED 10 FEET ON-CENTER MAX.
9. VERIFY ALL SITE SIGNAGE LOCATIONS WITH ARCH. PRIOR TO INSTALLATION OF
SITE SIGNAGE
LANDSCAPE AREAS
HEAVY DUTY ASPHALT
PROPERTY LINE
ASPHALT
FLATWORK
SITE GRAPHICS LEGEND
GRASS EXISTING STRUCTURE
TO REMAIN
N
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
KEY PLAN
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
PLAN TRUE
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
NORTH:
4/30/2024 10:13:06 AM
A u to d e sk
D o cs
/U
H V
U
N R e n o va tio n /P
B K
U H
V N
W S
E W
E R
R
.r vt
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
A100
ARCHITECTURAL SITE
PLAN - NEW
04/30/2024 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
Author
Checker
E A
S T
A
IR
L
IN
E R
O A
D
V
IC
T O
R
IA
T
E X
A S
A
A R
C H
IT
E
C T
U R
A L
S
IT
E P
L A
N
N E
W
04/30/2024
1" = 30'-0"
6 SITE PLAN - NEW
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
BUILDING ENVELOPE
BEAM
T 210-638-7200
A
N.I.C.
B
N.I.C.
C
N.I.C.
D
N.I.C.
N .I
.C
EXIST. CANOPY
' M
B
ABCDEFGHJKLMNPQRS
N.I.C.
4.5
COURTYARD
A N.I.C.
B N.I.C.
COURTYARD
C O
U R
T Y
A R
D
EXISTING OVERHEAD CANOPY TO REMAIN
LOCATION OF SEWER ROUTING TO
BE COORDINATED WITH LEAF AND
DALLY
A102
A102
PATCH AND REPAIR AREAS WHERE TRENCHING OCCURS AND MATCH EXISTING,
RE: CIVIL DWGS.
PATCH AND REPAIR AREAS
WHERE TRENCHING OCCURS
AND MATCH EXISTING,
RE: CIVIL DWGS.
N
SAN ANTONIO
601 N.W. Loop 410, Suite 400
San Antonio, TX 78216 210-829-0123 P 210-829-0578 F
TX Firm: BR 1608
ARCHITECT PBK Architects, Inc.
KEY PLAN
DATE PROJECT NUMBER
CLIENT
DRAWING HISTORY
PBK.com
DRAWN BY:
CHECKED BY:
PLAN TRUE
F O
R B
L U
E B
E A
M L
A B
E L
IN
G
/O C
R
F il e P a th
Plot Stamp:
1"
0"
NORTH:
4/30/2024 10:13:08 AM
A u to d e sk
D o cs
/U
H V
U
N R e n o va tio n /P
B K
U H
V N
W S
E W
E R
R
.r vt
N O
R T
H W
E S
T C
A M
P U
S
S E
W E
R R
E N
O V
A T
IO
N
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
A101
COMPOSITE PLAN -
FIRST FLOOR
04/30/2024 230599
UNIVERSITY OF HOUSTON VICTORIA
ISSUE FOR CONSTRUCTION
K. BRITTAIN
C. WHITTINGSTALL
E A
S T
A
IR
L
IN
E R
O A
D
V
IC
T O
R
IA
T
E X
A S
A
C O
M P
O S
IT
E
P L
A N
F
IR
S
T F
L O
O R
04/30/2024
1" = 20'-0"
6 COMPOSITE PLAN
PLAN
NORTH
NORTH
A
N.I.C.
B
N.I.C.
C
N.I.C.
D
N.I.C.
N .I
.C
EXIST. CANOPY
CIVIL
DALLY + ASSOCIATES
T 210-349-9098
LANDSCAPE
EDGELAND
T 512-476-2099
STRUCTURAL
IES
T 210-349-9098
MEPT
LEAF ENGINEERING
T 210-638-7200
TECHNOLOGY
COMBS CONSULTING GROUP
T 210-698-7887
BUILDING ENVELOPE
BEAM
T 210-638-7200
KEY NOTE LEGEND
KEYNOTE DESCRIPTION
/2
SOUND ATTENUATION, FIRE
BLANKET, OR THERMAL BATTS
WHERE INDICATED ON PLANS
CONTINUOUS SEALANT AT
BASE LAYER, BOTH SIDES.
STRIKE FLUSH WITH FACE
LAYER.
SOUND ATTENUATION, FIRE
BLANKET, OR THERMAL BATTS
WHERE INDICATED ON PLANS
CONTINUOUS SEALANT,
BOTH SIDES.
GALVANIZED STEEL EDGE TRIM, TYP.
COMPRESSED FIRE SAFING AT
RATED PARTITIONS; SOUND
ATTENUATION INSULATION AT
SOUND RATED PARTITIONS
AS NEEDED, TYP.
TAPE AND FLOAT JOINTS,
AND MATCH EXISTING
FINISH.
CONTINUOUS
GALVANIZED
STEEL CORNER
BEAD AS
NEEDED, TYP.
BASE TO MATCH
EXISTING, TYP.
BRACE FRAMING FOR 6" STUDS
STUD TYPE STUD PROP. SPACING MAX. LENGTH MISCELLANEOUS
SJ 20
(40 KSI)
(20 GA.)
1X = 1.787 IN^4
rx = 2.253 IN
A = 0.2148 IN^2
Sx = 0.539 IN^3
4.-0" O.C. 20'-0"
BRACE AT MID-
POINT FOR
LENGTHS OVER
20'-0"
BRACE FRAMING FOR 3 5/8" STUDS
SJ 20
(40 KSI)
(20 GA.)
1X = 0.541 IN^4
rx = 1.429 IN
A = 0.2136 IN^2
Sx = 0.273 IN^3
4.-0" O.C. 14'-0"
BRACE AT MID-
POINT FOR
LENGTHS OVER
14'-0"
STUD TYPE STUD PROP. SPACING MAX. LENGTH MISCELLANEOUS
HOW TO USE THIS SHEET
1. NOT EVERY PARTITION TYPE SHOWN IS NECESSARILY INTENDED FOR USE ON THIS
PROJECT, REFER TO FLOOR PLANS FOR REFERENCE MARKS INDICATING APPLICABLE
PARTITION TYPES.
2. REFER TO BRACING DETAILS FOR SUPPORT OF THE TOP OF EACH PARTITION TYPE AND
BRACING OF PARTITIONS THAT EXCEED LIMITING HEIGHT OF PARTITION TYPES.
3. REFER TO FINISH SCHEDULES FOR APPLIED FINISHES TO BOTH SIDES OF WALLS.
4. COORDINATE TOPS OF FINISHED WALLS WITH ADJACENT CEILING HEIGHTS PER
SCHEDULES, SECTIONS AND OR DETAILS.
5. CONSULT ARCH. FOR ANY DISCREPANCIES OR QUESTIONS REGARDING PARTITIONS
PRIOR TO INSTALLATION.
INTERIOR METAL STUD PARTITION NOTES
1. ALL METAL STUD PARTITIONS SHALL BE 25 GAUGE METAL STUDS AT 16" O.C. U.N.O., IF THE
LIMITING HEIGHT FOR A 25 GAUGE METAL STUD PARTITION IS EXCEEDED, INCREASE
GAUGE OF STUDS. NOTIFY ARCH. PRIOR TO INSTALLATION.
2. PROVIDE 20 GAUGE METAL STUDS, IN LIEU OF 25 GAUGE METAL STUDS, AT STUD WALL
WITH TILE FINISHES.
3. METAL STUD PARTITION BRACING
A. WHERE BRACING METHODS BETWEEN THIS SHEET AND STRUCT. CONFLICT, STRUCT.
SHALL OVERRIDE, NOTIFY ARCH. PRIOR TO INSTALLATION
B. PROVIDE INTERMEDIATE BRACING AT ALL METAL STUD PARTITIONS THAT EXCEED
THE VERTICAL LIMIT HEIGHT OF METAL STUDS
C. ALL BRACING SHALL BE AT STUD POINTS
4. SET ALL FLOOR TRACKS ON A CONTINUOUS RIBBON OF SEALANT.
5. USE CONT. DEEP LEG DEFLECTION TRACK AT TOP OF ALL PARTITION CONNECTIONS AT
TOP-OF-DECK LOCATIONS, REFER TO "TYP STUD FRAMING TO DECK" DETAIL.
6. PROVIDE TILE BACKER BOARDS FULL HEIGHT AT ALL PARTITIONS NOT AT SHOWERS, NOT
ADJACENT TO PLUMBING FIXTURES, AND WITHOUT TILE FINISHES IN ALL TOILET ROOMS.
7. RIGIDLY BRACE ALL DOOR FRAMES AT THE HEAD, HINGE, AND STRIKE SIDES, RIGIDLY
BRACE ALL WINDOW FRAMES AT THE HEAD, JAMBS, AND SILL.
8. LOCATE CONTROL JOINTS IN GYPSUM BOARD PARTITIONS AS FOLLOWS
A. PARTITIONS OR FURRING EXCEEDING 30'-0" SPANS HORIZ. AND OR VERT.
B. WHERE A PARTITION ABUTS A STRUCTURAL ELEMENT OR DISSIMILAR WALL
C. AT CHANGES WITHIN PLANE OF PARTITION
D. AT EXPANSION JOINTS
E. AT BOTH JAMBS OF INTERIOR AND EXTERIOR DOOR FRAMES AND WINDOW FRAMES,
ABOVE AND BELOW FOR FULL HEIGHT OF WALL
9. FIRE-RATED PARTITIONS
A. REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR DETAILED DESCRIPTIONS OF
FIRE-RATED PARTITIONS
B. PROVIDE TYPE "X" FIRE RESISTIVE GYPSUM BOARD, 5/8" THICK U.N.O.
C. FILL ALL GAPS AND DECK VOIDS WITH CONT. FIRESAFING INSUL.
D. SEAL BOTTOM OF PARTITION ON BOTH SIDES, PARTITION PERIMETER, AND ALL
PENETRATIONS WITH CONT. FIRE-RATED SEALANT
10.PARTITIONS WITH SOUND ATTENUATION BATT INSUL. BLANKETS
A. PROVIDE FULL THICK SOUND ATTENUATION BATT INSUL. BLANKETS FULL HEIGHT OF
PARTITION U.N.O.
B. FILL ALL GAPS AND DECK VOIDS WITH CONT. SOUND ATTENUATION SAFING INSUL.
C. TAPE AND BED OR CAULK ALL JOINTS BETWEEN GYPSUM BOARD PANELS
D. SEAL BOTTOM OF PARTITION ON BOTH SIDES, PARTITION PERIMETER, AND ALL
PENETRATIONS WITH CONT. ACOUSTICAL SEALANT (USE SEALANT INDICATED IN
ITEM ABOVE, IN LIEU OF ACOUSTICAL SEALANT, AT PARTITIONS DESIGNATED AS
FIRE-RATED PARTITIONS)
INTERIOR CMU PARTITION NOTES
1. CMU PARTITION BRACING
A. WHERE BRACING METHODS BETWEEN THIS SHEET AND STRUCT. CONFLICT, STRUCT.
SHALL OVERRIDE, NOTIFY ARCH. PRIOR TO INSTALLATION.
B. PROVIDE INTERMEDIATE BRACING AT ALL CMU PARTITIONS AT CONDITIONS AS
INDICATED ON THE "PARTITION TYPES-TYP CMU WALL BRACING" DETAIL.
2. REFER TO WALL SECTIONS FOR THE USE OF STARTER COURSES AT THE BASE OF
INTERIOR PARTITIONS.
3. PROVIDE CMU LINTELS FOR ALL OPENINGS IN INTERIOR CMU PARTITIONS, COORD. WITH
STRUCT. DOCUMENTS.
4. PROVIDE 3/4" SPACE BETWEEN TOP OF CMU PARTITION AND STRUCTURE AND OR DECK
ABOVE FOR POTENTIAL DEFLECTION, SEAL AS INDICATED ON PARTITION TYPE, OR AS
INDICATED IN THESE NOTES.
5. REFER TO STRUCT. DOCUMENTS FOR ALL REINFORCING, BOND BEAM LOCATIONS, AND
LINTEL SCHEDULES.
6. LOCATE CONTROL JOINTS IN CMU PARTITIONS AS FOLLOWS, U.N.O. BY STRUCT.
A. PARTITIONS EXCEEDING 25'-0" IN PLAN LENGTH
B. WHERE PARTITION ABUTS A STRUCTURAL ELEMENT OF DISSIMILAR WALL
C. AT EXPANSION JOINTS
D. REFER TO DETAILS FOR ADDITIONAL LOCATIONS
7. FIRE-RATED PARTITIONS
A. REFER TO THE UL FIRE RESISTANCE DIRECTORY FOR DETAILED DESCRIPTIONS OF
FIRE-RATED PARTITIONS
B. FILL ALL GAPS AND DECK VOIDS WITH CONT. FIRESAFING INSUL.
C. SEAL FIRE-RATED PARTITION PERIMETER AND ALL PENETRATIONS WITH CONT.
FIRE-RATED SEALANT
6" MTL. STUD TO DECK S6 NONE
ONE LAYER 5/8" TYPE "X"
GYP. BD.
6" THICK SOUND ATTENUATION
BLANKETS FULL HEIGHT OF
PARTITION
SCHEDULED
BASE
6" MTL STUD
TYPE FIRE RAT'G DESCRIPTION
CONT. ACOUSTICAL
SEALANT AND BACKER
ROD BOTH SIDES
DEFLECTION TRACK FILL
VOIDS AS REQ'D AT
CORRUGATED DECK
SCHEDULED
CEILING
METAL DECK
S6A ONE HOUR 6" MTL. STUD TO DECK (UL-U423)
FLOOR RUNNER W/CONT. ACOUST.
SEALANT ON BOTH SIDES
REFER TO TYP STUD
FRAMING TO DECK
DETAIL
CONT. FIRE-RATED
SEALANT AND BACKER
ROD BOTH SIDES AT "A"
7 1/4"
MTL DECK
SCREW FASTENERS, TYP
CONT 22 GA MIN GALV MTL
PLATE, SPAN TWO RIBS OF DECK
MIN WITH SCREW FASTENERS
ON EACH SIDE OF STUD
THIS DETAIL IS INTENDED TO
SHOW THE STUD FRAMING
CONNECTION TO DECK
CONDITION AND BRIDGING
INFORMATION ONLY AND
DOES NOT SHOW OTHER
ADDITIONAL INFORMATION,
REFER TO PARTITION TYPES
AND CEILING DETAILS FOR
ALL OTHER MATERIALS,
COMPONENTS, AND
ASSOCIATED INFORMATION
M
IN6
MTL STUD TO DECK ABOVE, LEAVE
1/2" MIN GAP AT TOP AT CONT
DEFLECTION TRACK CONDITIONS, DO
NOT ATTACH STUD TO CONT
DEFLECTION TRACK
ATTACH ANY BOARD ON EITHER
SIDE OF STUD NO CLOSER THAN
6" MIN TO TRACK, REFER TO
PARTITION TYPES
MTL CLIP ANGLE AT EACH STUD
CONT COLD-ROLLED MTL CHANNEL
BRIDGING AT 48" OC VERT MAX AND
WITHIN 18" VERT MAX OF TOP OF
STUD FRAMING AND WITHIN 18" VERT
MAX OF BOTTOM OF STUD FRAMING,
ATTACH TO EACH CLIP ANGLE
CONT MTL RUNNER TRACK AT CEILING
BULKHEAD FRAMING, DEEP LEG
DEFLECTION TRACK AT PARTITIONS
TO DECK FRAMING, SCREW ATTACH
TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .