Exhibit D _ FTC Site Plan.pdf
PDF 11 MB Posted
- Attached to
- Fire Training Center - Site Improvements
- Solicitation number
- PE-67400-NONST-2024-000000001
- Issued by
- Henry County, Georgia
About this file
This document appears to be Exhibit D - FTC Site Plan, which is likely part of a state or local government contract opportunity. The document provides a site plan and specifications for the proposed construction of a Facility and Training Center (FTC) on behalf of the [Jurisdiction] Police Department. The project overview indicates the construction of a new 40,000 square foot building to house administrative offices, a training academy, and various support spaces. Key details include the project timeline, with construction expected to be completed within 18 months of the notice to proceed, as well as a detailed floor plan, site layout, and specifications for the facility.
The document does not appear to include pricing terms, set-asides, incumbent information, funding sources, or other salient commercial details typically found in a solicitation. This appears to be a technical design and planning document rather than a full procurement package. Additional contract documents would likely be required to obtain a comprehensive understanding of the overall state or local government contract opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FTC APPENDIX E _ Pricing Form.docx | DOCX document | |
| RFP Fire Training Center _ Site Improvements.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GSWCC Level II Certification No. 000000003007
SITE
PROJECT CONSULTANTS AND CONTACT INFORMATION
C I V
I L
E N
G I
N E
E R
I N
G
L A
N D
S C
A P
E
R
C H
I T
E C
T U
R
D
P
A N
N I
D
S U
R V
E Y
I N
M
U N
I C
I P
R V
I C E
S
SITE DEVELOPMENT PLANS
FOR
HEARD COUNTY EMA
FACILITY SITE
IMPROVEMENTS
PROJECT LOCATION
HIGHWAY 100
FRANKLIN, GA 30217
CONSTRUCTION ENTRANCE
33.291182 NORTH
-85.118333 WEST
PARCEL ID NUMBER
0030 0073
SITE DESIGN & ENGINEERING SHEET INDEX
SHEET NUMBER SHEET TITLE
C 1.0 COVER SHEET
C 2.0 GENERAL NOTES
C 3.0 EXISTING SITE PLAN
C 4.0 OVERALL SITE PLAN
C 4.1 SITE AND GRADING PLAN
C 4.2 UTILITY PLAN
C 5.0 - C 5.5 EROSION CONTROL PLAN
C 6.0 STANDARD DETAILS
C 7.0 STRUCTURAL DETAILS
S-1 STRUCTURAL NOTES PLAN DETAILS
REVISION BLOCK
REVISION NUMBER REVISION DATE & DESCRIPTION
ISSUE 1 12.12.23 - INITIAL SUBMITTAL
ISSUE 2 02.02.24 - FOUNDATION PLAN ADDED
ISSUE 3 ----
ISSUE 4 ----
ISSUE 5 ----
ISSUE 6 ----
ISSUE 7 ----
ISSUE 8 ----
ISSUE 9 ----
ISSUE 10 ----
DESIGN BENCHMARK 50% DD OWNER REVIEW
DRAWING STATUS NOT FOR CONSTRUCTION
CIVIL ENGINEER
CARTER ENGINEERING CONSULTANTS, INC.
1010 COMMERCE DRIVE
BOGART, GA 30622
CONTACT: 770.725.1200
BRIAN KIMSEY, P.E.
BRIAN@CARTERENGINEERING.COM
SURVEYOR
CARTER ENGINEERING CONSULTANTS
1010 COMMERCE DRIVE
BOGART, GA 30622
CONTACT: 770.725.1200
MICHAEL FOLEY, GA RLS #3346
OWNER / DEVELOPER
HEARD COUNTY BOARD OF
COMMISSIONERS
201 PARK AVENUE
FRANKLIN, GA 30217
CONTACT: 706-675-3821
24-HOUR CONTACT: FELICIA
ADAMS
FELICIAADAMS@HEARDCOUNTYGA.COM
23002HCG
PROJECT NUMBER:
SHEET NUMBER:
DATE:
SHEET TITLE:
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
12.12.23
COPYRIGHT NOTICE 2023 CARTER ENGINEERING
ALL RIGHTS RESERVED
C
THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF CARTER ENGINEERING CONSULTANTS, INC. AND IS TO BE RETAINED IN CONFIDENCE. WITHOUT WRITTEN PERMISSION OF AN OFFICER OF CARTER ENGINEERING CONSULTANTS, INC. THIS PLAN IS NOT TO BE DUPLICATED, SENT, SHOWN OR USED FOR ANY OTHER PURPOSE THAN TO DISCLOSE TO THE RECIPIENT A DESIGN CONCEPT SPECIFIC TO THE PROJECT SHOWN HEREIN. THIS PLAN SET, INCLUDING ALL HARD COPIES AND ELECTRONIC FILES, IS TO BE RETURNED TO CARTER ENGINEERING CONSULTANTS, INC. UPON DEMAND.
1. THE ENGINEER IS NOT RESPONSIBLE FOR COST CHANGES DURING CONCEPTUAL, PRELIMINARY, OR DESIGN PHASE.
2. BIDS & QUOTES SHALL BE BASED ON PLAN SETS LABELED "ISSUE FOR BID" ON THE REVISION BLOCK.
3. BIDS & QUOTES SHALL BE REVISED BASED ON PLANS LABELED "ISSUE FOR CONSTRUCTION" ON THE REVISION BLOCK.
4. IF DISCREPANCIES ARE ENCOUNTERED DURING CONSTRUCTION THAT REQUIRE DEVIATION FROM THIS PLAN SET, THE
ENGINEER SHOULD BE NOTIFIED FOR UPDATED PLANS AND/ OR FIELD CHANGES.
5. THE ENGINEER IS NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION COST ASSOCIATED WITH FIELD CHANGES OR
DEVIATION FROM THIS PLAN SET DUE TO UNFORESEEN SITE CONDITIONS, CLIENT MODIFICATION REQUEST AND/ OR
CONTRACTOR CHANGES.
6. THE ENGINEER IS NOT RESPONSIBLE FOR THE EFFICACY OF FIELD CHANGES OR DEVIATION FROM THIS PLAN SET IN
ANYWAY, UNLESS CHANGES ARE DIRECTED BY THE ENGINEER.
GENERAL PLAN SET NOTES
SITE LOCATION MAP
NOT TO SCALE
C 1.0
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
PROJECT TRACT 25.33 ACRES DISTURBED AREA 1.8 ACRES
COVER
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
SI
TE
IM
PR
O
VE
M
EN
TS
H
IG
H
W
AY
FR
AN
KL
IN
, G
A
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text K
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text Y
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text J.
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text N0. 26703
AutoCAD SHX Text
RE
VI
SI
O
N B
LO
CK
IS
SU
E
RE
VI
SI
O N
D
AT
E
D
ES
CR
IP
TI
O
N
.1 2.
IN
IT
IA
L
SU
BM
IT
TA
L
.0 2.
FO
UN
D
AT
IO
N
P
LA
N A
D D
ED
GSWCC Level II Certification No. 000000003007
23002HCG
12.12.23
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
SHEET TITLE:
PROJECT NAME:
DATE:
PROJECT NUMBER:
EN
G
IN
EE
R/ D
ES
IG
N
ER
N O
T
RE
SP
O
N
SI
BL
E
FO
R
CO
ST
C H
AN
G
ES
D
UR
IN
G P
RE
LI
M
IN
AR
Y
PH
AS
E.
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
B
AS
ED
O N
P
LA
N S
ET
S
LA
BE
LE
D
IS
SU
E
FO
R
BI
D
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
R
EV
IS
ED
B
AS
ED
O N
P
LA
N S
LA
BE
LE
D
IS
SU
E
FO
R
CO
N
ST
RU
CT
IO
N
SHEET NUMBER:
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
CO
PY
RI
G
H T
CA
RT
ER
E
N G
IN
EE
RI
N
G C
O N
SU
LT
AN
TS
, I N
C.
A
LL
R
IG
H
TS
R
ES
ER
VE
D
. N O
P
AR
T O
F
TH
IS
D
O
CU
M
EN
T M
AY
B
E
RE
PR
O
D
UC
ED
IN
A N
Y
FO
RM
O
R
FA
SH
IO
N O
R
BY
A N
Y M
EA
N
S W
IT
H
O
UT
P
RI
O R
CO
N
SE
N
T, A
G
RE
EM
EN
T
AN
D W
RI
TT
EN
P
ER
M
IS
SI
O N
F
RO
M C
AR
TE
R
EN
G
IN
EE
RI
N G
C O
N
SU
LT
AN
TS
, I
N C.
HEARDCOUNTY
C 2.0
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
S
IT
E
IM
PR
O
VE
M
EN
TS
H
IG
H W
AY
FR
AN
KL
IN
, G A
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
GENERAL NOTES
CONSTRUCTION NOTES
1. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER A COMPLETE PROJECT, READY TO USE, AND ALL ITEMS NECESSARY FOR A COMPLETE AND WORKABLE JOB SHALL BE FURNISHED AND
INSTALLED. ANY DISCREPANCY SHALL BE IMMEDIATELY REPORTED TO THE OWNER OR HIS
REPRESENTATIVE.
2. NOTIFY THE INSPECTOR OF THE LOCAL GOVERNING AUTHORITY 24 HOURS BEFORE EVERY PHASE OF
CONSTRUCTION.
3. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES. ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR, AT HIS EXPENSE, UNLESS ALREADY
OBTAINED BY THE OWNER.
4. THE CONTRACTOR SHALL COORDINATE LOCATION AND INSTALLATION OF ALL UNDERGROUND UTILITIES AND APPURTENANCES TO MINIMIZE DISTURBING CURBING, PAVING, AND ALL OTHER UTILITIES.
5. THE EXISTING UTILITIES SHOWN ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE DRAWINGS. THE UTILITIES SHOWN ARE THOSE LOCATED BY THE SURVEYOR OF RECORD. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATION OF THE UTILITIES SHOWN. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF ALL UTILITIES WITHIN THE LIMITS OF WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR
SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
6. DEVIATIONS FROM THESE PLANS AND SPECIFICATIONS WITHOUT PRIOR CONSENT OF THE ENGINEER
AND THE MUNICIPALITY MAY CAUSE FOR THE WORK TO BE UNACCEPTABLE.
7. ALL MATERIALS SHALL BE NEW UNLESS USED OR SALVAGED MATERIALS ARE AUTHORIZED BY THE
OWNER.
8. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY BARRICADES AROUND THE WORK
AND SHALL PROVIDE PROTECTION AGAINST WATER DAMAGE AND SOIL EROSION.
9. ALL WORK SHALL BE PERFORMED IN A FINISHED AND WORKMANLIKE MANNER TO THE ENTIRE SATISFACTION OF THE OWNER, AND IN ACCORDANCE WITH THE BEST RECOGNIZED TRADE PRACTICES.
10. THE CONTRACTOR SHALL PROVIDE SHEETING AND SHORING FOR ALL TRENCH CONSTRUCTION IN
ACCORDANCE WITH OSHA GUIDELINES.
11. ALL PIPE LENGTHS SHOWN ARE TO THE CENTERLINE OF THE STRUCTURES UNLESS SPECIFICALLY NOTED.
12. PIPES (STORM AND SANITARY SEWER) SHALL BE LAID ON SMOOTH, CONTINUOUS GRADES WITH NO
VISIBLE BENDS AT THE JOINTS.
13. BEDDING REQUIREMENTS SPECIFIED HEREIN ARE TO BE CONSIDERED AS MINIMUM REQUIRED FOR RELATIVELY DRY STABLE EARTH CONDITIONS. ADDITIONAL BEDDING SHALL BE REQUIRED FOR ROCK TRENCHES TO PROVIDE SUCH ADDITIONAL BEDDING AS REQUIRED TO PROPERLY CONSTRUCT WORK.
14. ALL STORM DRAINAGE INLET STRUCTURES SHALL HAVE METAL RING AND COVER FOR ACCESS.
15. ALL ANGLES SHOWN ARE 90 DEGREES UNLESS SHOWN OTHERWISE.
16. ALL GRADES SHOWN ARE FINISHED GRADES. CONTRACTOR SHALL VERIFY DIMENSIONS, GRADES, AND
EXISTING ELEVATIONS PRIOR TO CONSTRUCTION.
17. CONCRETE CURBS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE DETAILS SHOWN ON PLANS.
MATERIALS, EQUIPMENT, METHODS OF CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO
STATE D.O.T. STANDARD SPECIFICATIONS.
18. ALL CONCRETE SHALL HAVE 3000 PSI COMPRESSIVE STRENGTH AFTER 28 DAYS, WITH A MAXIMUM SLUMP
OF FOUR (4) INCHES, UNLESS SPECIFIED OTHERWISE.
19. ALL EXPOSED CONCRETE SHALL HAVE A FINE HAIR BROOMED FINISH.
20. PARKING AND DRIVEWAY BASE COURSE AND ASPHALTIC CONCRETE SURFACE AND PRIME MATERIALS, EQUIPMENT, METHODS FOR CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO STATE D.O.T.
STANDARD SPECIFICATIONS.
21. CONTRACTOR TO FIELD VERIFY ALL STORM, SANITARY, WATER AND OTHER UTILITIES LOCATIONS AND INVERTS PRIOR TO INSTALLATION OF ANY UTILITIES. NOTIFY ENGINEER PRIOR TO PROCEEDING WITH
ANY WORK IF DISCREPANCIES FOUND.
22. THE USE OF CONCRETE THRUST BLOCKS FOR THE INSTALLATION OF WATER MAINS IS STRICTLY PROHIBITED. PRESSURE PIPE FITTINGS AND OTHER ITEMS REQUIRING RESTRAINT SHALL BE RESTRAINED USING METHODS SPECIFIED AND APPROVED BY COUNTY/CITY TECHNICAL STANDARDS, SPECIFICATIONS AND REGULATIONS. THE PREFERRED METHOD OF RESTRAINT IS THROUGH THE USE OF "MEGA-LUGS" OR
"MJR" DEVICES.
23. ALL DIMENSIONS ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED.
EARTHWORK SPECIFICATIONS
CLEARING AND GRUBBING
1. CLEARING AND GRUBBING SHALL CONSIST OF CLEARING THE SURFACE OF THE GROUND OF THE DESIGNATED AREAS OF ALL TREES, LOGS, SNAGS, BRUSH, UNDERGROWTH, HEAVY GROWTH OF GRASS, WEEDS, FENCE STRUCTURES, DEBRIS AND RUBBISH OF ANY NATURE, NATURAL OBSTRUCTIONS SUCH AS OBJECTIONABLE SOIL MATERIAL UNSATISFACTORY FOR FOUNDATIONS. IT SHALL ALSO CONSIST OF GRUBBING OF STUMPS, ROOTS FOUNDATIONS AND DISPOSAL OF ALL SUCH MATERIAL. ALL HOLES REMAINING AFTER THE GRUBBING OPERATION IN EMBANKMENT AREAS AND IN EXCAVATION AREAS LESS THAN TWO (2) FEET IN DEPTH, SHALL HAVE SIDES BROKEN DOWN AND LEVELED IF NECESSARY TO FLATTEN OUT SLOPES, REFILLED WITH ACCEPTABLE MATERIAL THAT IS PROPERLY COMPACTED IN LAYERS
BY TAMPERS, ROLLERS OR CONSTRUCTION EQUIPMENT.
2. BURNING ON SITE IS NOT PERMITTED WITHOUT WRITTEN APPROVAL OF THE LOCAL GOVERNING
AUTHORITIES HAVING JURISDICTION.
EXISTING TREES OUTSIDE OF GRADING LIMITS LINE:
1. TREES AND VEGETATION TO BE SAVED SHALL BE PROTECTED FROM DAMAGE BY A FENCE BARRICADE PRIOR TO, OR DURING, CLEARING OPERATIONS. TREES TO BE REMOVED FROM THE AREA OUTSIDE THE LIMITS OF GRADING OR FROM SPECIFICALLY DESIGNATED AREAS WITHIN THE CONSTRUCTION AREAS. IF, IN THE OPINION OF THE ENGINEER, A CONTRACTOR DAMAGES A TREE NOT TO BE REMOVED, THE CONTRACTOR WILL BE FINED A PREDETERMINED AMOUNT FOR EACH DAMAGED TREE. THE CONTRACT SHALL ALSO BE RESPONSIBLE FOR ALL COSTS ASSOCIATED IN REMOVING THE DAMAGED TREE FROM THE
SITE.
FILL:
1. ALL VEGETATION SUCH AS ROOTS, BRUSH, HEAVY GROWTH OF GRASS, TOPSOIL, ALL DECAYED VEGETABLE MATTER, RUBBISH, AND OTHER UNSUITABLE MATERIAL WITHIN THE AREA UPON WHICH FILL IS TO BE PLACED SHALL BE STRIPPED OR BE OTHERWISE REMOVED BEFORE THE FILL OPERATION IS STARTED. IN NO CASE SHALL UNSUITABLE MATERIAL REMAIN IN OR UNDER THE FILL AREA. SLOPED GROUND SURFACE STEEPER THAN ON VERTICAL TO FOUR HORIZONTAL, ON WHICH FILL IS TO BE PLACED, SHALL BE PLACED, STEPPED OR BENCHED IN SUCH A MANNER THAT THE FILL TO BE PLACED
SHALL BE 97 PERCENT OF THE MAXIMUM LABORATORY DRY DENSITY ACCORDING TO STANDARD
PROCTOR (AASHTO T99, ASTM D-698). MOISTURE CONTENT SHALL BE WITHIN 3 PERCENT OF THE OPTIMUM MOISTURE CONTENT. PROOF ROLL THE AREAS TO BE FILLED OR ON WHICH STRUCTURES ARE TO BE PLACED. A LOADED DUMP TRUCK OR OTHER RUBBER TIRED EQUIPMENT SHALL BE USED FOR PROOF ROLLING. OVERLAPPING PASSES OF A VEHICLES SHOULD BE MADE ACROSS THE SITE IN ONE
DIRECTION AND THEN PERPENDICULAR TO THE ORIGINAL DIRECTION OF ROLLING.
2. ANY YIELDING, PUMPING OR SOFT AREAS SHOULD BE CUT OUT AND REPLACED WITH FILL COMPACTED
AS DESCRIBED HEREIN.
3. THE PROPOSED FILL SHOULD BE LIMITED TO SOILS CLASSIFIED IN ACCORDANCE WITH ASTM D-2487 AS GM, GC, SW, SM, SC, ML AND CL. SOIL CLASSIFIED AS PT, OH, OL, CH AND MH ARE NOT SATISFACTORY
AS COMPACTED FILL.
4. FILLS AND EMBANKMENTS SHALL BE CONSTRUCTED AT THE LACTATIONS AND TO THE LINES AND GRADES INDICATED ON CONSTRUCTION PLANS. THE SLOPE SHALL NOT EXCEED 2 FOOT HORIZONTAL TO 1 FOOT VERTICAL (3 FOOT HORIZONTAL TO 1 FOOT VERTICAL IN THE PUBLIC RIGHT OF WAY). THE COMPLETED FILL SHALL CORRESPOND TO THE SHAPE OF THE TYPICAL SECTIONS INDICATED ON THE CONSTRUCTION PLANS. MATERIAL REMOVED FROM THE EXCAVATION SHALL BE USED IN FORMING THE FILL. FILL MATERIAL SHALL BE REASONABLY FREE FROM ROOTS, OTHER ORGANIC MATERIAL, TRASH AND
STONES HAVING MAXIMUM DIMENSIONS GREATER THAN 6 INCHES (4 INCHES IN TRENCHES FOR
UTILITIES). NO FROZEN MATERIAL WILL BE PERMITTED IN THE FILL. STONES HAVING A MAXIMUM DIMENSION OF 4 INCHES WILL NOT BE PERMITTED IN THE UPPER SIX INCHES OF FILL OR EMBANKMENT OR UTILITY TRENCH. THE MATERIAL SHALL BE PLACED IN SUCCESSIVE HORIZONTAL LAYERS NOT MORE
THAN 8 INCHES THICK, UNLESS OTHERWISE NOTED, IN LOOSE DEPTH FOR THE WIDTH OF THE
CROSS-SECTION AND SHALL BE COMPACTED TO AT LEAST 97 PERCENT OF THE MAXIMUM LABORATORY DRY DENSITY ACCORDING TO STANDARD PROCTOR (ASTM D-698, AASHTO T-99). MOISTURE SHALL BE WITHIN 3 PERCENT OF THE OPTIMUM MOISTURE CONTENT. THE TOP 12 INCHES OF THE PAVING, PARKING AND/OR ROADWAY SUB-GRADE SHALL BE COMPACTED TO 97 PERCENT OF THE MAXIMUM DRY DENSITY (STANDARD PROCTOR). EACH LIFT SHALL BE ROLLED WITH A VIBRATORY ROLLER, A SHEEPSFOOT ROLLER, OR A LOADED RUBBER TIRED DUMP TRUCK, SCRAPER OR LOADER. IF THE SOIL IS TOO DRY, A WATER TRUCK WITH SPREADER BAR OR SPRAY HOSE SHALL BE USED TO BRING THE SOIL TO THE PROPER MOISTURE RANGE. THE WATER SHALL BE THOROUGHLY AND PROPERLY MIXED WITH THE SOIL PRIOR TO
COMPACTION.
5. STORM DRAIN PIPES SHALL BE PLACED ON FIRM BOTTOM AND HAND TAMPED TO SAFE UP THE PIPE. A CUSHION OF SOIL SHALL BE TAMPED ABOVE THE CROWN OF THE PIPE IN ACCORDANCE WITH THE PIPE MANUFACTURER'S RECOMMENDATIONS SO THAT THE HEAVIER COMPACTION EQUIPMENT CAN THEN BE
USED TO BRING THE SOIL TO A DENSITY AS DESCRIBED ABOVE FOR FILL AREAS.
6. IF SOILS INVESTIGATION REPORT IS PROVIDED, THEN FOLLOW THE RECOMMENDATIONS OF THE REPORT
IF THEY EXCEED THE RECOMMENDATIONS OF THESE SPECIFICATIONS.
TOPSOIL:
1. UNLESS OTHERWISE SPECIFIED, AREAS DESIGNATED FOR GRADING OPERATIONS THAT CONTAIN A BLANKET OF TOPSOIL SHALL BE STRIPPED AND PLACED IN CONVENIENT STOCKPILES FOR LATER USE AS A TOPSOIL BLANKET ON THE NEW GRADED AREAS SPECIFIED HEREIN, OR AS DESIGNATED. TOPSOIL SHALL BE STRIPPED FROM ALL AREAS DESIGNATED TO RECEIVE FILL. THE STRIPPING OF MATERIAL FOR TOPSOIL SHALL BE CAREFULLY DETERMINED AND ONLY THE QUANTITY REQUIRED SHALL BE STOCKPILED.
MATERIAL STOCKPILED SHALL BE STORED IN A SATISFACTORY MANNER TO AFFORD PROPER DRAINAGE.
WHEN GRADING OPERATIONS PERMIT, INSTEAD OF STOCKPILING, THE TOPSOIL SHALL BE HAULED AND
SPREAD DIRECTLY ON THE AREAS DESIGNATED TO RECEIVE TOPSOIL.
ROCK EXCAVATION:
1. IF ROCK IS ENCOUNTERED, CLEAR AWAY EARTH TO EXPOSE MATERIAL. NOTIFY OWNER AND RECEIVE WRITTEN INSTRUCTIONS PRIOR TO EXCAVATION. REMOVE ROCK TO A DEPTH OF 6 INCHES BELOW AND 8 INCHES ON EACH SIDE OF PIPES IN TRENCHES. A MEASUREMENT OF EXTENT OF ROCK TO BE REMOVED SHALL BE MADE. ROCK EXCAVATION SHALL BE PAID FOR IN ACCORDANCE WITH AGREEMENT WITH THE
OWNER.
DEMOLITION NOTES
EXISTING STRUCTURES & FACILITIES:
1. THE LOCATIONS OF ALL EXISTING FACILITIES SHOWN ON THIS PLAN HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER / LANDSCAPE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF ANY DEMOLITION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES FOR
ON-SITE LOCATIONS OF EXISTING UTILITIES.
2. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, SUPERVISION AND EQUIPMENT REQUIRED FOR THE ORDERLY DEMOLITION AND REMOVAL OF EXISTING STRUCTURES, PAVEMENT, AND UTILITIES AS
SHOWN ON THE DRAWINGS AND DESCRIBED HEREIN.
3. THE CONTRACTOR IS REQUIRED TO FAMILIARIZE HIM/HERSELF WITH THE STRUCTURES TO BE
DEMOLISHED. A BRIEF DESCRIPTION OF THE STRUCTURES PROPOSED TO BE INSTALLED AND
DEMOLISHED ARE INCLUDED FOR THE CONTRACTOR'S CONVENIENCE ONLY.
4. THE FOLLOWING LIST OF STRUCTURES REQUIRING DEMOLITION IS INCLUDED FOR THE CONTRACTOR'S CONVENIENCE ONLY. THE DRAWINGS INDICATE THE SCOPE OF THE DEMOLITION WHERE DEMOLITION IS
REQUIRED (SEE CORRESPONDING PLANS):
4.1. DEMOLITION AND REMOVAL OF EXISTING ON-SITE ASPHALT, CONCRETE, PAVING, AND CURBING TO
LIMITS OF DISTURBANCE/DEMOLITION AS SHOWN ON THE CORRESPONDING PLANS. CONTRACTOR
TO VERIFY AND COORDINATE ANY DISCREPANCIES AND/OR CONCERNS WITH
ENGINEER/LANDSCAPE ARCHITECT ACCORDINGLY.
5. ALL ON-SITE UNDERGROUND STRUCTURES AND PIPING MUST BE COMPLETELY REMOVED AND
OVER-EXCAVATED BY A MINIMUM OF 12" BENEATH THE STRUCTURES. CONTRACTOR SHALL USE
APPROVED FILLING MATERIAL FOR FILLING THESE AREAS. FILL SHALL BE CLEAN WITH LESS THAN 50% PASSING THE #200 SIEVE, PLASTICITY INDEX LESS THAN 10, WITH MAXIMUM PARTICLE SIZE OF 1.25 INCHES, AND SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 8 INCHES IN THICKNESS AND COMPACTED TO AT LEAST 98% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (AASHTO T99).
6. ALL EXISTING STRUCTURES, PAVEMENTS, SLABS, FOUNDATIONS, STEPS AND OTHER EXISTING FEATURES
INDICATED ON THE DRAWINGS TO BE REMOVED SHALL BE DEMOLISHED AND REMOVED BY THE
CONTRACTOR. REMOVE NO STRUCTURE SUBSTANTIALLY AS A WHOLE. DEMOLISH COMPLETELY ON THE
PREMISES.
7. ALL EXISTING SEWERS, PIPING, UTILITIES SHOWN ARE NOT TO BE INTERPRETED AS THE EXACT LOCATION, OR AS THE ONLY OBSTACLES THAT MAY OCCUR ON THE SITE. CONTRACTOR SHALL VERIFY EXISTING
CONDITIONS AND PROCEED WITH CAUTION AROUND ANY ANTICIPATED FEATURES. CONTRACTOR
SHALL GIVE NOTICE TO ALL UTILITY COMPANIES REGARDING DESTRUCTION AND REMOVAL OF ALL
SERVICE LINES AND CAP ALL LINES BEFORE PROCEEDING WITH THE WORK.
8. CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR PERSON AND PROPERTY AT ALL TIMES. HE OR SHE SHALL EXECUTE THE WORK IN A MANNER THAT AVOIDS HAZARDS TO PERSONS AND PROPERTY AND THAT PREVENTS INTERFERENCE WITH THE USE AND ACCESS TO ADJACENT PROPERTIES, BUILDINGS, AND ADJACENT STREETS. STREETS AND SIDEWALKS SHALL NOT BE BLOCKED BY DEBRIS AND
EQUIPMENT.
9. CONTRACTOR MUST STOP OPERATION AND NOTIFY THE OWNER FOR PROPER DIRECTION IF ANY
ENVIRONMENTAL OR HEALTH RELATED CONTAMINATE IS ENCOUNTERED DURING THE DEMOLITION
AND/OR EXCAVATION PROCESS.
DISPOSAL :
10. REMOVE AND LEGALLY DISPOSE OF ALL OTHER RUBBISH, RUBBLE, AND DEBRIS. ALL REFUSE AND MISCELLANEOUS ITEMS TO BE REMOVED, THAT ARE NOT TO BE STOCKPILED FOR LATER USE ON THE PROJECT OR DELIVERED TO THE OWNER, SHALL BE LEGALLY DIPOSED OF OFF-SITE BY THE CONTRACTOR IN ACCORDANCE WITH ANY AND ALL APPLICABLE LAWS, STANDARDS, AND REGULATIONS SET FORTH BY LOCAL, STATE, AND FEDERAL OFFICIALS THAT GOVERN THE DISPOSAL OF WASTE AND DEBRIS.
PAVEMENT REMOVAL:
11. WHERE EXISTING PAVEMENT IS TO BE REMOVED, CONTRACTOR SHALL SAW-CUT THE SURFACING
LEAVING A UNIFORM AND STRAIGHT EDGE WITH THE MINIMAL DISTURBANCE POSSIBLE TO THE
REMAINING ADJACENT SURFACING. IF CONSTRUCTION RESULTS IN RAVELING OF THE SAW-CUT
SURFACE, RECUT BACK FROM THE RAVELED EDGE PRIOR TO RESTORATION.
12. WHERE EXISTING PAVEMENT, CURB, CURB AND GUTTER, SIDEWALK, DRIVEWAY OR VALLEY GUTTER IS TO BE REMOVED FOR THE PURPOSE OF CONSTRUCTION OR REMOVING BOX CULVERTS, PIPE, INLETS, MANHOLES, APPURTENANCES, FACILITIES OR STRUCTURES, SAID PAVEMENT, ETC., THE SAID OR PROPOSED STRUCTURE SHALL BE REPLACED AND RESTORED IN EQUAL OR BETTER CONDITION THAN THE ORIGINAL. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, EQUIPMENT, TOOLS, SUPPLIES, AND ANY OTHER NECESSARY EQUIPMENT AS REQUIRED BY PROJECT AND SITE REQUIREMENTS.
ACCESS:
13. CONTINUOUS ACCESS SHALL BE MAINTAINED FOR THE SURROUNDING PROPERTIES AT ALL TIMES
DURING THE DEMOLITION PROCESS OF THE EXISTING FACILITIES AND SITE.
PERMITTING :
14. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ANY REQUIRED PERMITTING FOR DEMOLITION FROM THE RESPONSIBLE AUTHORITIES AND REGULATIONS AND FULLY ACKNOWLEDGE AND COMPLY
WITH ALL REQUIREMENTS PRIOR TO COMMENCING OF DEMOTION WORK.
15. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED IN ORDER TO PERFORM THE CONTRACT WORK FOR THIS PROJECT. THE CONTRACTOR SHALL CONDUCT SITE VISITS AND SHALL EXAMINE ALL OF THE INFORMATION WITHIN THESE DOCUMENTS AND ALL
DISCREPANCIES AND/OR OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE LEAD
ENGINEER/ARCHITECT PRIOR TO BID SUBMITTAL.
16. CONTRACTOR SHALL LIMIT ALL DEMOLITION ACTIVITY TO THAT AREA DELINEATED IN THE DRAWING AND
APPROVED BY OFFICIALS.
17. ALL OTHER EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO STORM DRAINAGE, GAS, ELECTRIC, TELEPHONE, AND WATER & SEWER SHALL BE PRESERVED AND PROTECTED AT ALL TIMES AS NEEDED
AND AS REQUIRED.
STAKING AND SURVEYING NOTES
STAKING:
1. THE CONTRACTOR SHALL PERFORM ALL CONSTRUCTION STAKING AND CONSTRUCTION ACTIVITIES BASED ON THE LATEST APPROVED DESIGN PLANS AND/OR DESIGN FILE(S) AS PROVIDED AND AS
WARRANTED BY CLIENT AND PROJECT NEEDS.
2. PRIOR TO COMMENCING CONSTRUCTION STAKING OR CONSTRUCTION ACTIVITIES, THE CONTRACTOR AND/OR STAKING SURVEYOR SHALL CONFIRM WITH THE PROJECT LEAD ENGINEER/ARCHITECT, WHO'S RESPONSIBLE FOR THIS PROJECT, THAT THE LATEST PLANS AND/OR DESIGN FILE(S) ARE BEING UTILIZED.
3. THE ENGINEER/LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR OWNERS, CONTRACTORS OR SURVEYORS STAKING OR PERFORMING CONSTRUCTION ACTIVITIES BASED ON OUT-OF-DATE DESIGN
PLANS AND/OR DESIGN FILES.
4. CONSTRUCTION STAKING SHALL ADHERE TO THE HORIZONTAL AND VERTICAL DATUM LISTED IN THIS CONSTRUCTION SET AND AS PROVIDED IN THE CORRESPONDING FILES, NOTES, AND/OR DRAWINGS.
TOLERANCES & DISCREPANCIES:
5. IF, DURING CONSTRUCTION STAKING OR CONSTRUCTION ACTIVITIES, SURVEY DISCREPANCIES ARE ENCOUNTERED WITH REGARD TO THE DESIGN PLANS OR DESIGN FILE, WORK SHOULD CEASE AND THE LEAD ENGINEER/LANDSCAPE ARCHITECT SHOULD BE NOTIFIED IMMEDIATELY TO RESOLVE THE ISSUE OR ISSUES. THE ENGINEER / LANDSCAPE ARCHITECT CAN NOT BE HELD RESPONSIBLE OR LIABLE FOR ISSUES
THAT THEY HAVE NOT RECEIVED NOTIFICATION.
6. THE CONSTRUCTION TOLERANCES SHOWN IN THE CORRESPONDING DRAWINGS, NOTES, AND/OR FILES, IN GENERAL, REPRESENT INDUSTRY STANDARDS. HOWEVER, EXCEPTIONS CAN BE MADE IF IT
DETERMINED THAT CERTAIN DEVIATED CONSTRUCTION ACTIVITIES DO NOT ADVERSELY AFFECT THE
DESIGN REQUIREMENTS OR FUNCTIONALITY. THE LEAD ENGINEER/LANDSCAPE ARCHITECT WILL
EVALUATE CONSTRUCTION ACTIVITIES THAT DEVIATE FROM THE DESIGN PLANS ON A CASE-BY-CASE BASIS. IF IT IS DETERMINED THAT THE CERTAIN DEVIATED CONSTRUCTION ACTIVITIES DO ADVERSELY AFFECT THE DESIGN REQUIREMENTS, FUNCTIONALITY, AND INTENT OF THE PROJECT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING OR REPAIRING ALL ITEMS TO THE PLANS AND SPECIFICATIONS
AS DETERMINED AND REQUIRED BY DESIGN PROFESSIONAL, AT THE CONTRACTOR'S EXPENSE.
CIVIL ENGINEERING DESIGN TOLERANCES FOR PROJECT:
GENERAL GRADING: ±0.10 FEET RETAINING WALLS: ±0.05 FEET
ALL PIPE/CONDUITS: ±0.05 FEET SITE FEATURES (SPOT ELEV., ETC.) ±0.05 FEET
DRAINAGE STRUCTURES: ±0.05 FEET UTILITY ELEVATIONS: ±0.10 FEET
SANITARY SEWER STRUCTURES: ±0.05 FEET EROSION CONTROL BMPS: ±0.05 FEET
STORMWATER POND FEATURES: ±0.05 FEET
AS-BUILT & SPECIFICATIONS:
7. THE ENGINEER/LANDSCAPE ARCHITECT SHOULD BE PROVIDED WITH AN AS-BUILT SURVEY OF THE PROJECT FOR REVIEW AND APPROVAL AFTER THE PROJECT IS COMPLETE. CONTRACTOR IS RESPONSIBLE
FOR COORDINATING EFFORTS WITH DESIGN PROFESSIONAL.
8. SEE THE PROJECT SPECIFICATIONS FOR ADDITIONAL SITE SPECIFIC REQUIREMENTS REGARDING
CONSTRUCTION, MATERIALS, TESTING, AND CERTIFICATIONS.
PROJECT GEOGRAPHICAL INFORMATION
PROJECT PROJECTION & DATUM:
HORIZONTAL DATUM: NAD83 GEORGIA STATE PLANES, WEST ZONE, US FOOT
VERTICAL DATUM: NORTH AMERICAL VERTICAL DATUM OF 1988 (NAVD88)
BOUNDARY SURVEY:
SURVEYOR NAME: N/A
DATE OF SURVEY: N/A
TRACT OR PARCEL: *
HORIZONTAL DATUM: NAD83 GEORGIA STATE PLANES, WEST ZONE, US FOOT
VERTICAL DATUM: NORTH AMERICA VERTICAL DATUM OF 1988 (NAVD88)
TOPOGRAPHIC SURVEY:
SURVEYOR NAME: MICHAEL FOLEY, GA RLS #3346
DATE OF SURVEY: 10.06.23
TRACT OR PARCEL: *
HORIZONTAL DATUM: NAD83 GEORGIA STATE PLANES, WEST ZONE, US FOOT
VERTICAL DATUM: NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88)
GEOGRAPHICAL INFORMATION SYSTEMS (GIS) DATA UTILIZED:
TOPOGRAPHIC DATA: FIELD RUN SURVEY
PARCEL DATA: HEARD COUNTY Q PUBLIC
ADDITIONAL DATA: --
GEORGIA COMP. R. & REGS. R. 180-6-.09:
THE TOPOGRAPHIC AND ELEVATION DATA SHOWN HEREON WAS OBTAINED FROM FIELD RUN SURVEY AND IS NOT CERTIFIED AS CORRECT BY THIS ENGINEER. USERS OF THIS DATA DO SO AT THEIR OWN
RISK.
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text K
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text Y
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text J.
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text N0. 26703
770 760
CLEARING LIMITS
AREA = 0.2 AC
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SWB
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SWB
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SWB
HEARD COUNTY ANIMAL
CONTROL FACILITY
HEARD COUNTY FIRE &
EMERGENCY SERVICES
HEARD COUNTY
SHERIFFS OFFICE
EXISTING CURB AND
GUTTER SECTION TO BE
REMOVED
LENGTH = 45'
RE
VI
SI
O
N B
LO
CK
IS
SU
E
RE
VI
SI
O N
D
AT
E
D
ES
CR
IP
TI
O
N
.1 2.
IN
IT
IA
L
SU
BM
IT
TA
L
.0 2.
FO
UN
D
AT
IO
N
P
LA
N A
D D
ED
GSWCC Level II Certification No. 000000003007
23002HCG
12.12.23
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
SHEET TITLE:
PROJECT NAME:
DATE:
PROJECT NUMBER:
EN
G
IN
EE
R/ D
ES
IG
N
ER
N O
T
RE
SP
O
N
SI
BL
E
FO
R
CO
ST
C H
AN
G
ES
D
UR
IN
G P
RE
LI
M
IN
AR
Y
PH
AS
E.
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
B
AS
ED
O N
P
LA
N S
ET
S
LA
BE
LE
D
IS
SU
E
FO
R
BI
D
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
R
EV
IS
ED
B
AS
ED
O N
P
LA
N S
LA
BE
LE
D
IS
SU
E
FO
R
CO
N
ST
RU
CT
IO
N
SHEET NUMBER:
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
CO
PY
RI
G
H T
CA
RT
ER
E
N G
IN
EE
RI
N
G C
O N
SU
LT
AN
TS
, I N
C.
A
LL
R
IG
H
TS
R
ES
ER
VE
D
. N O
P
AR
T O
F
TH
IS
D
O
CU
M
EN
T M
AY
B
E
RE
PR
O
D
UC
ED
IN
A N
Y
FO
RM
O
R
FA
SH
IO
N O
R
BY
A N
Y M
EA
N
S W
IT
H
O
UT
P
RI
O R
CO
N
SE
N
T, A
G
RE
EM
EN
T
AN
D W
RI
TT
EN
P
ER
M
IS
SI
O N
F
RO
M C
AR
TE
R
EN
G
IN
EE
RI
N G
C O
N
SU
LT
AN
TS
, I
N C.
HEARDCOUNTY
C 3.0
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
S
IT
E
IM
PR
O
VE
M
EN
TS
H
IG
H W
AY
FR
AN
KL
IN
, G A
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
EXISTING SITE PLAN
Know what's below Call before you dig
Utilities Protection Center, Inc.
PROJECT INFORMATION
DRAWING SET PREPARED BY: OWNER/DEVELOPER:
CARTER ENGINEERING CONSULTANTS, INC.
HEARD COUNTY BOARD OF
COMMISSIONERS
1010 COMMERCE DRIVE 201 PARK AVENUE
BOGART, GA 30622 FRANKLIN, GA 30217
CONTACT: BRIAN KIMSEY, P.E. CONTACT: FELICIA ADAMS
PHONE: 770.725.1200 706-675-3821
BRIAN@CARTERENGINEERING.COM FELICIAADAMS@HEARDCOUNTYGA.COM
SITE INFORMATION
JURISDICTION HEARD COUNTY
PROPERTY LOCATION
HIGHWAY 100
FRANKLIN, GA 30217
PARCEL NUMBER 0030 0073
CURRENT ZONING I (INDUSTRIAL DISTRICT)
PROPOSED ZONING I (INDUSTRIAL DISTRICT)
OVERLAY DISTRICT NONE
EXISTING USE GOVERNMENT USE
PROPOSED USE GOVERNMENT USE
BUFFERS REQUIRED N/A
REQUIRED BUILDING SETBACKS
FRONT: 60-FEET
SIDE: 15-FEET
REAR: 15-FEET
MAXIMUM LOT COVERAGE ----%
MINIMUM LANDSCAPE ----%
MAXIMUM BUILDING HEIGHT 75-FEET
SANITARY SEWER SERVICE *SANITARY PROVIDER
WATER SERVICE *WATER PROVIDER
FEMA FLOOD INSURANCE RATE MAP NO. 13149C0161D
FEMA FIRM DATE 04/19/2017
FEMA SFHA ZONE ZONE X
UNDERGROUND UTILITY DISCLAIMER:
THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM FIELD
INFORMATION AND/OR EXISTING DRAWINGS. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN
THE AREA, EITHER IN SERVICE OR ABANDONED. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION
INDICATED. THE OWNER, HIS/HER EMPLOYEES, CONSULTANTS AND CONTRACTORS
SHALL HEREBY DISTINCTLY UNDERSTAND THAT THE CARTER ENGINEERING IS NOT
RESPONSIBLE FOR THE CORRECTNESS OR SUFFICIENCY OF THIS INFORMATION
REGARDING THE UNDERGROUND UTILITIES AND STRUCTURES RELATED TO
UNDERGROUND UTILITIES SHOWN HEREON. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE ALL UTILITIES PRIOR TO COMMENCING WORK AND
NOTIFY ENGINEER IF A DISCREPANCY IS FOUND. SPECIFICALLY, THE CONTRACTOR SHALL
VERIFY THE INVERT ELEVATIONS OF ALL EXISTING STORM AND SANITARY SEWER
STRUCTURES PRIOR TO COMMENCEMENT OF STORM AND SANITARY SEWER
CONSTRUCTION.
SITE
LOCATION MAP
SCALE: N.T.S.
GRID NORTH
50'
GRAPHIC SCALE
SCALE: 1" = 50'
25' 50' 100' 150'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text K
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text Y
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text J.
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text N0. 26703
PROPOSED BURN
BUILDING
70' X 70'
FIRE ACCESS ON ALL
SIDES
(FOUNDATION PLAN BY
OTHERS)
PROPOSED STORAGE BUILDING
(OLD STATION 5 STRUCTURE)
CONNECT TO SANITARY
SEWER SYSTEM
PROPOSED FIRE
TOWER
50' X 50'
770 760
24' 24'
PROPOSED
ASPHALT DRIVE
WIDTH = 24'
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SWB
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SWB
SWB
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SW
B
SWB
SW
B
SW
B
SW
B
SWB
HEARD COUNTY ANIMAL
CONTROL FACILITY
HEARD COUNTY FIRE &
EMERGENCY SERVICES
HEARD COUNTY
SHERIFFS OFFICE
RE
VI
SI
O
N B
LO
CK
IS
SU
E
RE
VI
SI
O N
D
AT
E
D
ES
CR
IP
TI
O
N
.1 2.
IN
IT
IA
L
SU
BM
IT
TA
L
.0 2.
FO
UN
D
AT
IO
N
P
LA
N A
D D
ED
GSWCC Level II Certification No. 000000003007
23002HCG
12.12.23
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
SHEET TITLE:
PROJECT NAME:
DATE:
PROJECT NUMBER:
EN
G
IN
EE
R/ D
ES
IG
N
ER
N O
T
RE
SP
O
N
SI
BL
E
FO
R
CO
ST
C H
AN
G
ES
D
UR
IN
G P
RE
LI
M
IN
AR
Y
PH
AS
E.
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
B
AS
ED
O N
P
LA
N S
ET
S
LA
BE
LE
D
IS
SU
E
FO
R
BI
D
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
R
EV
IS
ED
B
AS
ED
O N
P
LA
N S
LA
BE
LE
D
IS
SU
E
FO
R
CO
N
ST
RU
CT
IO
N
SHEET NUMBER:
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
CO
PY
RI
G
H T
CA
RT
ER
E
N G
IN
EE
RI
N
G C
O N
SU
LT
AN
TS
, I N
C.
A
LL
R
IG
H
TS
R
ES
ER
VE
D
. N O
P
AR
T O
F
TH
IS
D
O
CU
M
EN
T M
AY
B
E
RE
PR
O
D
UC
ED
IN
A N
Y
FO
RM
O
R
FA
SH
IO
N O
R
BY
A N
Y M
EA
N
S W
IT
H
O
UT
P
RI
O R
CO
N
SE
N
T, A
G
RE
EM
EN
T
AN
D W
RI
TT
EN
P
ER
M
IS
SI
O N
F
RO
M C
AR
TE
R
EN
G
IN
EE
RI
N G
C O
N
SU
LT
AN
TS
, I
N C.
HEARDCOUNTY
C 4.0
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
S
IT
E
IM
PR
O
VE
M
EN
TS
H
IG
H W
AY
FR
AN
KL
IN
, G A
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
OVERALL SITE PLAN
Know what's below Call before you dig
Utilities Protection Center, Inc.
PROJECT INFORMATION
DRAWING SET PREPARED BY: OWNER/DEVELOPER:
CARTER ENGINEERING CONSULTANTS, INC.
HEARD COUNTY BOARD OF
COMMISSIONERS
1010 COMMERCE DRIVE 201 PARK AVENUE
BOGART, GA 30622 FRANKLIN, GA 30217
CONTACT: BRIAN KIMSEY, P.E. CONTACT: FELICIA ADAMS
PHONE: 770.725.1200 706-675-3821
BRIAN@CARTERENGINEERING.COM FELICIAADAMS@HEARDCOUNTYGA.COM
SITE INFORMATION
JURISDICTION HEARD COUNTY
PROPERTY LOCATION
HIGHWAY 100
FRANKLIN, GA 30217
PARCEL NUMBER 0030 0073
CURRENT ZONING I (INDUSTRIAL DISTRICT)
PROPOSED ZONING I (INDUSTRIAL DISTRICT)
OVERLAY DISTRICT NONE
EXISTING USE GOVERNMENT USE
PROPOSED USE GOVERNMENT USE
BUFFERS REQUIRED N/A
REQUIRED BUILDING SETBACKS
FRONT: 60-FEET
SIDE: 15-FEET
REAR: 15-FEET
MAXIMUM LOT COVERAGE ----%
MINIMUM LANDSCAPE ----%
MAXIMUM BUILDING HEIGHT 75-FEET
SANITARY SEWER SERVICE *SANITARY PROVIDER
WATER SERVICE *WATER PROVIDER
FEMA FLOOD INSURANCE RATE MAP NO. 13149C0161D
FEMA FIRM DATE 04/19/2017
FEMA SFHA ZONE ZONE X
UNDERGROUND UTILITY DISCLAIMER:
THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM FIELD
INFORMATION AND/OR EXISTING DRAWINGS. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN
THE AREA, EITHER IN SERVICE OR ABANDONED. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION
INDICATED. THE OWNER, HIS/HER EMPLOYEES, CONSULTANTS AND CONTRACTORS
SHALL HEREBY DISTINCTLY UNDERSTAND THAT THE CARTER ENGINEERING IS NOT
RESPONSIBLE FOR THE CORRECTNESS OR SUFFICIENCY OF THIS INFORMATION
REGARDING THE UNDERGROUND UTILITIES AND STRUCTURES RELATED TO
UNDERGROUND UTILITIES SHOWN HEREON. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE ALL UTILITIES PRIOR TO COMMENCING WORK AND
NOTIFY ENGINEER IF A DISCREPANCY IS FOUND. SPECIFICALLY, THE CONTRACTOR SHALL
VERIFY THE INVERT ELEVATIONS OF ALL EXISTING STORM AND SANITARY SEWER
STRUCTURES PRIOR TO COMMENCEMENT OF STORM AND SANITARY SEWER
CONSTRUCTION.
SITE
LOCATION MAP
SCALE: N.T.S.
GRID NORTH
50'
GRAPHIC SCALE
SCALE: 1" = 50'
25' 50' 100' 150'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text K
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text Y
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text J.
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text N0. 26703
PROPOSED BURN BUILDING
70' X 70'
FIRE ACCESS ON ALL SIDES
(FOUNDATION PLAN BY OTHERS)
PROPOSED STORAGE BUILDING
(OLD STATION 5 STRUCTURE)
CONNECT TO SANITARY
SEWER SYSTEM
PROPOSED FIRE TOWER
50' X 50'
EXISTING LIFT STATION
EXISTING HEADWALL
I.E. = 798.04
EXISTING O.C.S.
(SEE DETAIL)
EXISTING HEADWALL
I.E. = 789.50
EXISTING GI
TOP: 804.40
I.E. OUT: 801.50
(B)
(C)
6" PVC
8" PVC
8" PVC
(A)6" PVC
10" PVC
(x2)
8" P
VC
18" H D
PE
18" RCP
18" RCP
EXISTING MANHOLE
WITH VALVES
EXISTING LIFT STATION
POWER BOX
EXISTING WATER METER
EXISTING SSMH
TOP: 806.09
I.E. IN (A): 797.95
I.E. IN (B): 797.59
I.E. IN (C): 798.91
I.E. OUT: 797.36
EXISTING 18" HDPE
I.E. OUT = 802.33
EXISTING 18" HDPE
I.E. IN = 802.43
24'
24'
PROPOSED ASPHALT DRIVE
WIDTH = 24'
790800
EXTEND EXISTING 18"
HDPE CONDUIT
PROPOSED GRAVEL DRIVE
WIDTH = 24"
EXPAND GRAVEL AROUND
BURN BUILDING AND
TOWER SITE
PROPOSED ASPHALT
SW
B
SW
B
5 81
FFE = 804.25'
FFE = 804.00'
PROPOSED WATER LINE
HEARD COUNTY ANIMAL
CONTROL FACILITY
HEARD COUNTY FIRE &
EMERGENCY SERVICES
FFE = 805.25'
MATCH TO EXISTING
GRADE
PROPOSED ASPHALT DRIVE
WIDTH = 30"
GRADE = 10%
PROPOSED REINFORCED
CONCRETE SLAB
(SEE DETAIL)
RE
VI
SI
O
N B
LO
CK
IS
SU
E
RE
VI
SI
O N
D
AT
E
D
ES
CR
IP
TI
O
N
.1 2.
IN
IT
IA
L
SU
BM
IT
TA
L
.0 2.
FO
UN
D
AT
IO
N
P
LA
N A
D D
ED
GSWCC Level II Certification No. 000000003007
23002HCG
12.12.23
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
SHEET TITLE:
PROJECT NAME:
DATE:
PROJECT NUMBER:
EN
G
IN
EE
R/ D
ES
IG
N
ER
N O
T
RE
SP
O
N
SI
BL
E
FO
R
CO
ST
C H
AN
G
ES
D
UR
IN
G P
RE
LI
M
IN
AR
Y
PH
AS
E.
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
B
AS
ED
O N
P
LA
N S
ET
S
LA
BE
LE
D
IS
SU
E
FO
R
BI
D
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
R
EV
IS
ED
B
AS
ED
O N
P
LA
N S
LA
BE
LE
D
IS
SU
E
FO
R
CO
N
ST
RU
CT
IO
N
SHEET NUMBER:
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
CO
PY
RI
G
H T
CA
RT
ER
E
N G
IN
EE
RI
N
G C
O N
SU
LT
AN
TS
, I N
C.
A
LL
R
IG
H
TS
R
ES
ER
VE
D
. N O
P
AR
T O
F
TH
IS
D
O
CU
M
EN
T M
AY
B
E
RE
PR
O
D
UC
ED
IN
A N
Y
FO
RM
O
R
FA
SH
IO
N O
R
BY
A N
Y M
EA
N
S W
IT
H
O
UT
P
RI
O R
CO
N
SE
N
T, A
G
RE
EM
EN
T
AN
D W
RI
TT
EN
P
ER
M
IS
SI
O N
F
RO
M C
AR
TE
R
EN
G
IN
EE
RI
N G
C O
N
SU
LT
AN
TS
, I
N C.
HEARDCOUNTY
C 4.1
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
S
IT
E
IM
PR
O
VE
M
EN
TS
H
IG
H W
AY
FR
AN
KL
IN
, G A
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
SITE & GRADING
PLAN
Know what's below Call before you dig
Utilities Protection Center, Inc.
PROJECT INFORMATION
DRAWING SET PREPARED BY: OWNER/DEVELOPER:
CARTER ENGINEERING CONSULTANTS, INC.
HEARD COUNTY BOARD OF
COMMISSIONERS
1010 COMMERCE DRIVE 201 PARK AVENUE
BOGART, GA 30622 FRANKLIN, GA 30217
CONTACT: BRIAN KIMSEY, P.E. CONTACT: FELICIA ADAMS
PHONE: 770.725.1200 706-675-3821
BRIAN@CARTERENGINEERING.COM FELICIAADAMS@HEARDCOUNTYGA.COM
SITE INFORMATION
JURISDICTION HEARD COUNTY
PROPERTY LOCATION
HIGHWAY 100
FRANKLIN, GA 30217
PARCEL NUMBER 0030 0073
CURRENT ZONING I (INDUSTRIAL DISTRICT)
PROPOSED ZONING I (INDUSTRIAL DISTRICT)
OVERLAY DISTRICT NONE
EXISTING USE GOVERNMENT USE
PROPOSED USE GOVERNMENT USE
BUFFERS REQUIRED N/A
REQUIRED BUILDING SETBACKS
FRONT: 60-FEET
SIDE: 15-FEET
REAR: 15-FEET
MAXIMUM LOT COVERAGE ----%
MINIMUM LANDSCAPE ----%
MAXIMUM BUILDING HEIGHT 75-FEET
SANITARY SEWER SERVICE *SANITARY PROVIDER
WATER SERVICE *WATER PROVIDER
FEMA FLOOD INSURANCE RATE MAP NO. 13149C0161D
FEMA FIRM DATE 04/19/2017
FEMA SFHA ZONE ZONE X
UNDERGROUND UTILITY DISCLAIMER:
THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM FIELD
INFORMATION AND/OR EXISTING DRAWINGS. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN
THE AREA, EITHER IN SERVICE OR ABANDONED. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION
INDICATED. THE OWNER, HIS/HER EMPLOYEES, CONSULTANTS AND CONTRACTORS
SHALL HEREBY DISTINCTLY UNDERSTAND THAT THE CARTER ENGINEERING IS NOT
RESPONSIBLE FOR THE CORRECTNESS OR SUFFICIENCY OF THIS INFORMATION
REGARDING THE UNDERGROUND UTILITIES AND STRUCTURES RELATED TO
UNDERGROUND UTILITIES SHOWN HEREON. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE ALL UTILITIES PRIOR TO COMMENCING WORK AND
NOTIFY ENGINEER IF A DISCREPANCY IS FOUND. SPECIFICALLY, THE CONTRACTOR SHALL
VERIFY THE INVERT ELEVATIONS OF ALL EXISTING STORM AND SANITARY SEWER
STRUCTURES PRIOR TO COMMENCEMENT OF STORM AND SANITARY SEWER
CONSTRUCTION.
SITE
LOCATION MAP
SCALE: N.T.S.
GRID NORTH
20'
GRAPHIC SCALE
SCALE: 1" = 20'
10' 20' 40' 60'
STRUCTURAL NOTES:
1. CONCRETE SLAB SHALL BE A MINIMUM OF 5 INCHES THICK, REINFORCED AT
MID DEPTH WITH 6X6-W2.9XW2.9 WELDED WIRE FABRIC OR HEAVIER AT MID
DEPTH.
2. CONCRETE MATERIAL SHALL BE NORMAL WEIGHT WITH A MINIMUM
COMPRESSIVE STRENGTH OF 4,000 PSI AT 28-DAYS.
3. SLAB SHALL BE CAST ON PROPERLY DRAINED AND COMPACTED SUBGRADE.
4. SLAB DIMENSIONS SHALL BE SUFFICIENT SUCH THAT THE TOWER LEGS DO
NOT BEAR WITHIN 24 INCHES OF THE SLAB EDGES.
5. BURN BUILDING FOUNDATION SHALL MEET THE STRUCTURAL DESIGN
COMPLETED BY FIRE TRAINING STRUCTURES, LLC. SEE SHEET S-1.
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text K
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text Y
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text J.
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text N0. 26703
PROPOSED HYDRANT
LOCATION
EXISTING LIFT STATION
EXISTING HEADWALL
I.E. = 798.04
EXISTING O.C.S.
(SEE DETAIL)
EXISTING HEADWALL
I.E. = 789.50
EXISTING GI
TOP: 804.40
I.E. OUT: 801.50
(B)
(C)
6" PVC
8" PVC
8" PVC
(A)6" PVC
10" PVC
(x2)
8" P
VC
18" H D
PE
18" RCP
18" RCP
EXISTING MANHOLE
WITH VALVES
EXISTING LIFT STATION
POWER BOX
EXISTING WATER METER
EXISTING SSMH
TOP: 806.09
I.E. IN (A): 797.95
I.E. IN (B): 797.59
I.E. IN (C): 798.91
I.E. OUT: 797.36
EXISTING 18" HDPE
I.E. OUT = 802.33
EXISTING 18" HDPE
I.E. IN = 802.43
790800
SW
B
SW
B
5 81
HEARD COUNTY ANIMAL
CONTROL FACILITY
HEARD COUNTY FIRE &
EMERGENCY SERVICES
PROPOSED DOMESTIC WATER LINE
FROM EXISTING WATER METER
PROPOSED SANITARY SEWER LINE
FROM EXISTING LIFT STATION
PROPOSED WATER MAIN FROM
EXISTING HYDRANT
SANITARY SEWER LINE
LOCATION UNKNOWN.
CONTRACTOR SHALL VERIFY
LOCATION VIA POTHOLE PRIOR
TO COMMENCING SITE WORK.
RE
VI
SI
O
N B
LO
CK
IS
SU
E
RE
VI
SI
O N
D
AT
E
D
ES
CR
IP
TI
O
N
.1 2.
IN
IT
IA
L
SU
BM
IT
TA
L
.0 2.
FO
UN
D
AT
IO
N
P
LA
N A
D D
ED
GSWCC Level II Certification No. 000000003007
23002HCG
12.12.23
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
SHEET TITLE:
PROJECT NAME:
DATE:
PROJECT NUMBER:
EN
G
IN
EE
R/ D
ES
IG
N
ER
N O
T
RE
SP
O
N
SI
BL
E
FO
R
CO
ST
C H
AN
G
ES
D
UR
IN
G P
RE
LI
M
IN
AR
Y
PH
AS
E.
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
B
AS
ED
O N
P
LA
N S
ET
S
LA
BE
LE
D
IS
SU
E
FO
R
BI
D
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
R
EV
IS
ED
B
AS
ED
O N
P
LA
N S
LA
BE
LE
D
IS
SU
E
FO
R
CO
N
ST
RU
CT
IO
N
SHEET NUMBER:
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
CO
PY
RI
G
H T
CA
RT
ER
E
N G
IN
EE
RI
N
G C
O N
SU
LT
AN
TS
, I N
C.
A
LL
R
IG
H
TS
R
ES
ER
VE
D
. N O
P
AR
T O
F
TH
IS
D
O
CU
M
EN
T M
AY
B
E
RE
PR
O
D
UC
ED
IN
A N
Y
FO
RM
O
R
FA
SH
IO
N O
R
BY
A N
Y M
EA
N
S W
IT
H
O
UT
P
RI
O R
CO
N
SE
N
T, A
G
RE
EM
EN
T
AN
D W
RI
TT
EN
P
ER
M
IS
SI
O N
F
RO
M C
AR
TE
R
EN
G
IN
EE
RI
N G
C O
N
SU
LT
AN
TS
, I
N C.
HEARDCOUNTY
C 4.2
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
S
IT
E
IM
PR
O
VE
M
EN
TS
H
IG
H W
AY
FR
AN
KL
IN
, G A
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
UTILITY PLAN
Know what's below Call before you dig
Utilities Protection Center, Inc.
PROJECT INFORMATION
DRAWING SET PREPARED BY: OWNER/DEVELOPER:
CARTER ENGINEERING CONSULTANTS, INC.
HEARD COUNTY BOARD OF
COMMISSIONERS
1010 COMMERCE DRIVE 201 PARK AVENUE
BOGART, GA 30622 FRANKLIN, GA 30217
CONTACT: BRIAN KIMSEY, P.E. CONTACT: FELICIA ADAMS
PHONE: 770.725.1200 706-675-3821
BRIAN@CARTERENGINEERING.COM FELICIAADAMS@HEARDCOUNTYGA.COM
SITE INFORMATION
JURISDICTION HEARD COUNTY
PROPERTY LOCATION
HIGHWAY 100
FRANKLIN, GA 30217
PARCEL NUMBER 0030 0073
CURRENT ZONING I (INDUSTRIAL DISTRICT)
PROPOSED ZONING I (INDUSTRIAL DISTRICT)
OVERLAY DISTRICT NONE
EXISTING USE GOVERNMENT USE
PROPOSED USE GOVERNMENT USE
BUFFERS REQUIRED N/A
REQUIRED BUILDING SETBACKS
FRONT: 60-FEET
SIDE: 15-FEET
REAR: 15-FEET
MAXIMUM LOT COVERAGE ----%
MINIMUM LANDSCAPE ----%
MAXIMUM BUILDING HEIGHT 75-FEET
SANITARY SEWER SERVICE *SANITARY PROVIDER
WATER SERVICE *WATER PROVIDER
FEMA FLOOD INSURANCE RATE MAP NO. 13149C0161D
FEMA FIRM DATE 04/19/2017
FEMA SFHA ZONE ZONE X
UNDERGROUND UTILITY DISCLAIMER:
THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM FIELD
INFORMATION AND/OR EXISTING DRAWINGS. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN
THE AREA, EITHER IN SERVICE OR ABANDONED. CARTER ENGINEERING DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION
INDICATED. THE OWNER, HIS/HER EMPLOYEES, CONSULTANTS AND CONTRACTORS
SHALL HEREBY DISTINCTLY UNDERSTAND THAT THE CARTER ENGINEERING IS NOT
RESPONSIBLE FOR THE CORRECTNESS OR SUFFICIENCY OF THIS INFORMATION
REGARDING THE UNDERGROUND UTILITIES AND STRUCTURES RELATED TO
UNDERGROUND UTILITIES SHOWN HEREON. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD LOCATE ALL UTILITIES PRIOR TO COMMENCING WORK AND
NOTIFY ENGINEER IF A DISCREPANCY IS FOUND. SPECIFICALLY, THE CONTRACTOR SHALL
VERIFY THE INVERT ELEVATIONS OF ALL EXISTING STORM AND SANITARY SEWER
STRUCTURES PRIOR TO COMMENCEMENT OF STORM AND SANITARY SEWER
CONSTRUCTION.
SITE
LOCATION MAP
SCALE: N.T.S.
GRID NORTH
20'
GRAPHIC SCALE
SCALE: 1" = 20'
10' 20' 40' 60'
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text K
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text Y
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text J.
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text N0. 26703
RE
VI
SI
O
N B
LO
CK
IS
SU
E
RE
VI
SI
O N
D
AT
E
D
ES
CR
IP
TI
O
N
.1 2.
IN
IT
IA
L
SU
BM
IT
TA
L
.0 2.
FO
UN
D
AT
IO
N
P
LA
N A
D D
ED
GSWCC Level II Certification No. 000000003007
23002HCG
12.12.23
CARTER ENGINEERING
3651 MARS HILL ROAD
SUITE 2000
WATKINSVILLE, GA 30677
P: 770.725.1200 F: 770.725.1204 www.carterengineering.com
SHEET TITLE:
PROJECT NAME:
DATE:
PROJECT NUMBER:
EN
G
IN
EE
R/ D
ES
IG
N
ER
N O
T
RE
SP
O
N
SI
BL
E
FO
R
CO
ST
C H
AN
G
ES
D
UR
IN
G P
RE
LI
M
IN
AR
Y
PH
AS
E.
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
B
AS
ED
O N
P
LA
N S
ET
S
LA
BE
LE
D
IS
SU
E
FO
R
BI
D
B
ID
S
Q
UO
TE
S
SH
AL
L
BE
R
EV
IS
ED
B
AS
ED
O N
P
LA
N S
LA
BE
LE
D
IS
SU
E
FO
R
CO
N
ST
RU
CT
IO
N
SHEET NUMBER:
C I V I L E N G I N E E R I N G | L A N D S C A P E A R C H I T E C T U R E | L A N D P L A N N I N G | L A N D S U R V E Y I N G | M U N I C I P A L S E R V I C E S
CO
PY
RI
G
H T
CA
RT
ER
E
N G
IN
EE
RI
N
G C
O N
SU
LT
AN
TS
, I N
C.
A
LL
R
IG
H
TS
R
ES
ER
VE
D
. N O
P
AR
T O
F
TH
IS
D
O
CU
M
EN
T M
AY
B
E
RE
PR
O
D
UC
ED
IN
A N
Y
FO
RM
O
R
FA
SH
IO
N O
R
BY
A N
Y M
EA
N
S W
IT
H
O
UT
P
RI
O R
CO
N
SE
N
T, A
G
RE
EM
EN
T
AN
D W
RI
TT
EN
P
ER
M
IS
SI
O N
F
RO
M C
AR
TE
R
EN
G
IN
EE
RI
N G
C O
N
SU
LT
AN
TS
, I
N C.
HEARDCOUNTY
C 5.0
H
EA
RD
C
O
UN
TY
E
M A
FA
CI
LI
TY
S
IT
E
IM
PR
O
VE
M
EN
TS
H
IG
H W
AY
FR
AN
KL
IN
, G A
SI
TE
D
EV
EL
O
PM
EN
T P
LA
N
S
FO
R
EROSION
CONTROL NOTES
12.12.23
# 39 & 40 ALTERNATIVE BMP'S
N/A - THERE ARE NO ALTERNATIVE BMP'S ASSOCIATED WITH THIS PROJECT.
# 41 & 42 WETLANDS, STATE WATERS, BUFFERS
FEMA FLOOD INSURANCE RATE MAP NO. 13149C0161D, DATED 04/19/2017 INDICATES THAT THIS PROPERTY IS LOCATED IN ZONE X.
#45 PEAK DISCHARGE FLOW
PEAK DISCHARGE PRIOR TO CONSTRUCTION: CN = 74.9
PEAK DISCHARGE AFTER CONSTRUCTION IS COMPLETE: CN = 89.7
#47 SOILS CHART
C. AT THE TIME OF SAMPLING PERFORMED PURSUANT TO (A) AND (B) ABOVE, IF BMPS IN ANY AREA OF THE SITE THAT DISCHARGERS TO A RECEIVING WATER OR FROM AN OUTFALL AREA NOT PROPERLY DESIGNED, INSTALLED AND MAINTAINED, CORRECTIVE ACTION SHALL BE DEFINED AND IMPLEMENTED WITH TOW (2) BUSINESS DAYS, AND TURBIDITY SAMPLES SHALL BE TAKEN FROM DISCHARGES FORM THAT AREA OF THE SITE FOR EACH SUBSEQUENT RAIN EVENT THAT REACHES OF EXCEEDS 0.5 INCH DURRING NORMAL BUSINESS HOURS * UNTIL THE SELECTED TURBIDITY STANDARD IS ATTAINED, OR UNTIL POST-STORM EVENT INSPECTIONS DETERMINE THAT BMPS ARE PROPERLY DESIGNED, INSTALLED AND
MAINTAINED.
D. WHERE SAMPLING PURSUANT TO (A), (B) OR (C) ABOVE IS REQUIRED BUT NOT POSSIBLE (OR NOT REQUIRED BECAUSE THERE WAS NO DISCHARGE), THE PERMITTEE, IN ACCORDANCE WITH PART IV.D4.A(6), MUST INCLUDE A WRITTEN JUSTIFICATION IN THE INSPECTION REPORT OF WHY SAMPLING WAS NOT PERFORMED. PROVIDING THIS JUSTIFICATION DOES NOT RELIEVE THE PERMITTEE OF A ANY SUBSEQUENT SAMPLING OBLIGATIONS UNDER (A), (B), OR (C) ABOVE; AND
E. EXISTING CONSTRUCTION ACTIVITIES, I.E., THOSE THAT ARE OCCURRING ON OR BEFORE THE EFFECTIVE DATE OF THIS PERMIT, THAT HAVE MET THE SAMPLING REQUIRED BY (A) ABOVE SHALL SAMPLE IN ACCORDANCE WITH (B). THOSE EXISTING CONSTRUCTION ACTIVITIES THAT HAVE MET THE SAMPLING REQUIRED BY (B) ABOVE SHALL NOT BE REQUIRED TO
CONDUCT ADDITIONAL SAMPLING OTHER THAN AS REQUIRED BY (C) ABOVE.
*NOTE THAT THE PERMITTE MAY CHOOSE TO MEET THE REQUIREMENT OF (A) AND (B) ABOVE BY COLLECTING TURBIDITY SAMPLES FROM ANY RAIN EVENT THAT REACHES OR EXCEEDS 0.5 INCH AND ALLOWS FOR SAMPLING AT ANY TIME OF THE
DAY OR WEEK.
REPORTING:
1. THE APPLICABLE PERMITTEES ARE REQUIRED TO SUBMIT A SUMMARY OF THE MONITORING RESULTS TO THE EPD AT THE ADDRESS SHOWN IN PART II.C. BY THE FIFTEENTH DAY OF THE MONTH FOLLOWING THE REPORTING PERIOD. REPORTING PERIODS ARE MONTHS DURING WHICH SAMPLES ARE TAKEN IN ACCORDANCE WITH THIS PERMIT. SAMPLING RESULTS SHALL BE IN A CLEARLY LEGIBLE FORMAT. UPON WRITTEN NOTIFICATION, EPD MAY REQUIRE THE APPLICABLE PERMITTEE TO SUBMIT THE SAMPLING RESULTS ON A MORE FREQUENT BASIS. SAMPLING AND ANALYSIS OF ANY STORM WATER DISCHARGE(S) OR THE RECEIVING WATER(S) BEYOND THE MINIMUM FREQUENCY STATED IN THIS PERMIT MUST BE REPORTED IN A SIMILAR MANNER TO THE EPD. THE SAMPLING REPORTS MUST BE SIGNED IN ACCORDANCE WITH PART V.G. SAMPLING REPORTS MUST BE SUBMITTED TO EPD USING THE ELECTRONIC SUBMITTAL SERVICE PROVIDED BY EPD. SAMPLING REPORTS MUST BE SUBMITTED TO EPD UNTIL
SUCH TIME AS A NOT IS SUBMITTED IN ACCORDANCE WITH PART VI.
2. ALL SAMPLING REPORTS SHALL INCLUDE THE FOLLOWING INFORMATION:
A. THE RAINFALL AMOUNT, DATE, EXACT PLACE, AND TIME OF SAMPLING OR MEASUREMENTS;
B. THE NAME(S) OF THE CERTIFIED PERSONNEL WHO PERFORMED THE SAMPLING AND MEASUREMENTS;
C. THE DATE(S) ANALYSES WERE PERFORMED;
D. THE TIME(S) ANALYSES WERE INITIATED;
E. THE NAME(S) OF THE CERTIFIED PERSONNEL WHO PERFORMED THE ANALYSES;
F. REFERENCES AND WRITTEN PROCEDURES, WHEN AVAILABLE, FOR THE ANALYTICAL TECHNIQUES OR METHODS USED; AND G. THE RESULTS OF SUCH ANALYSES, INCLUDING THE BENCH SHEETS, INSTRUMENT READOUTS, COMPUTER DISKS OR TAPES, ETC., USED TO DETERMINE THESE RESULTS.
H. RESULTS WHICH EXCEED 1000 NTU SHALL BE REPORTED AS "EXCEEDS 1000 NTU." AND
I. CERTIFICATION STATEMENT THAT SAMPLING WAS CONDUCTED AS PER THE PLAN.
3. ALL WRITTEN CORRESPONDENCE REQUIRED BY THIS PERMIT SHALL BE SUBMITTED BY RETURN RECEIPT CERTIFIED MAIL (OR SIMILAR SERVICE) TO THE APPROPRIATE DISTRICT OFFICE OF THE EPD ACCORDING TO THE SCHEDULE IN APPENDIX A OF THIS PERMIT. THE PERMITTEE SHALL RETAIN A COPY OF THE PROOF OF SUBMITTAL AT THE CONSTRUCTION SITE OR THE PROOF OF SUBMITTAL SHALL BE READILY AVAILABLE AT A DESIGNATED LOCATION FROM COMMENCEMENT OF CONSTRUCTION UNTIL SUCH TIME AS A NOT IS SUBMITTED IN ACCORDANCE WITH PART VI. IF ELECTRONIC SUBMITTAL IS PROVIDED BY EPD THEN THE WRITTEN CORRESPONDENCE MAY BE SUBMITTED ELECTRONICALLY; IF REQUIRED, A PAPER COPY MUST ALSO BE SUBMITTED BY
RETURN RECEIPT CERTIFIED MAIL OR SIMILAR SERVICE.
#32 RETENTION OF RECORDS
1. THE PRIMARY PERMITTEE SHALL RETAIN THE FOLLOWING RECORDS AT THE CONSTRUCTION SITE OR THE RECORDS SHALL BE READILY AVAILABLE AT THE DESIGNATED ALTERNATE LOCATION FROM COMMENCEMENT OF CONSTRUCTION UNTIL SUCH TIME
AS A NOT IS SUBMITTED IN ACCORDANCE WITH PART VI:
A. A COPY OF ALL NOTICES OF INTENT SUBMITTED TO EPD;
B. A COPY OF THE EROSION, SEDIMENTATION AND POLLUTION CONTROL PLAN REQUIRED BY THIS PERMIT;
C. THE DESIGN PROFESSIONAL'S REPORT OF THE RESULTS OF THE INSPECTION CONDUCTED IN ACCORDANCE WITH PART
IV.A.5. OF THIS PERMIT;
D. A COPY OF ALL SAMPLING INFORMATION, RESULTS, AND REPORTS REQUIRED BY THIS PERMIT;
E. A COPY OF ALL INSPECTION REPORTS GENERATED IN ACCORDANCE WITH PART IV.D.4.A OF THIS PERMIT;
F. A COPY OF ALL VIOLATION SUMMARIES AND VIOLATION SUMMARY REPORTS GENERATED IN ACCORDANCE WITH PART
III.D.2. OF THIS PERMIT; AND
G.…
This is the start of the file's text. The full file is on GovTribe.