This file contains architectural floor plans for a Navy Recruitment office buildout project at MBC Unit 204 in Ottoville, American Samoa. The plans consist of 4 sheets showing different layouts: floor plan, CCTV/intercom layout, data/power layout, and AC layout. The space includes a 415 sq ft main Navy office, 99 sq ft storage room, 49 sq ft exam room, 18 sq ft security room, and a 78 sq ft balcony.

The plans detail specific requirements including wire shelving in storage areas, louvered pocket doors, CAT-6/5 outlets for VOIP phones, a 42" monitor installation with power outlet behind it, a 24K BTU AC unit to cover both main office and security room, and CCTV camera placement for full office coverage. The contractor is identified as Tony's Construction of American Samoa, and the plans are dated July 24, 2024 for approval. The drawings include specific construction specifications like 5/8" Type X gypsum board and 3-5/8" metal studs at 16" on center.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAVY OFFICE

415 SQFT

BALCONY

78 SQFT

UNIT 203

UNIT 205

9'16'

UP

LEGEND:

8" TYPE X GYP BD EA OR 1 SIDE 3-5/8" METAL STUDS @ 16" OC,

PAINT. ADDITIONAL 12" FROM EXISTING CEILING HEIGHT

EXISTING WALL

STORAGE ROOM

99 SQFT

EXAM ROOM

49 SQFT

'-4

5'

-6

5'

5'-7"

SECURITY

ROOM

18 SQFT

4'-6"

4'

DOCUMENT:

FOR APPROVAL

DRAWING NO:

BLDG. NAME

DRAWING TITLE:

LOCATION SITE:

PROJECT:

AS - BUILT

FOR DETAIL

FOR CONSTRUCTION

CONTRACTOR

CLIENT /OWNER

FL

FOR PRE-APPROVAL

DESIGN CONSULTANCY

TONY'S CONSTRUCTION

P.O. Box 5050

AMERICAN SAMOA

96799

NAVY RECRUITMENT

NAVY BUILDOUT PROJECT

MBC UNIT 204

OTTOVILLE, AMERICAN SAMOA

FLOOR PLAN

1/4

Wire Shelving per construction specs

Wire Shelving per construction specs j3pp9alc Callout louvered pocket door j3pp9alc Line j3pp9alc Line j3pp9alc Text Box

JP-8Z

PT-1210N

SMP5PM

NAVY OFFICE

415 SQFT

BALCONY

78 SQFT

MOSSOOI BUSINESS CENTER UNIT 204

P.O. BOX 5050 OTTOVILLE ROAD

PAGO PAGO, AS 96799

UNIT 203

UNIT 205

9'16'

UP

STORAGE ROOM

99 SQFT

EXAM ROOM

49 SQFT

'-4

5'

-6

5'

5'-7"

SECURITY

ROOM

18 SQFT

4'-6"

4'

42" MONITOR

JP-DV

AC-10S

EL-12S

JP-4MED

TRAINING GRAPHICS

EXTENDED CORDS

CUT-OFF

SWITCH

POWER OUTLET

BEHIND MONITOR

DOCUMENT:

FOR APPROVAL

DRAWING NO:

BLDG. NAME

DRAWING TITLE:

LOCATION SITE:

PROJECT:

AS - BUILT

FOR DETAIL

FOR CONSTRUCTION

CONTRACTOR

CLIENT /OWNER

FOR PROPOSAL

FOR PRE-APPROVAL

DESIGN CONSULTANCY

TONY'S CONSTRUCTION

P.O. Box 5050

AMERICAN SAMOA

96799

NAVY BUILDOUT PROJECT

MBC UNIT 204

OTTOVILLE, AMERICAN SAMOA

CCTV AND INTERCOM LAYOUT

2/4

FOR APPROVAL:

SIGN AND PRINT NAME

NAVY RECRUITMENT

1. Mark where you would like the entry phones. He has marked 1, but is that correct? Mark the location for the 2nd phone.

2. Coverage from the CCTV cameras. The back corner is a little weird, but I dont think we can go through the ceiling to put a camera facing the front door.

3. It looks like he has the 42' CCTV monitor in the correct location.

4. Do you need wood backing for an additional TV for the Navy? If so, where would you like that or will it be placed on a piece of furniture?

Hope they can so it will cover the entire office space, if not, relocate by test room facing the front door.

YES-50" will cover a lot of wall and loose space for the graphics

Please see comm install additional phone with extended cord.

WOOD BACKING ON

THIS WALL FOR TV

7/24/2024******** See attached updated entry system & CCTV/ NVR system components. I believe the older system components are referenced on the floor plan.

romeo.cruz1 Sticky Note 2ND Entry Phone with extended cable

BALCONY

78 SQFT

MOSSOOI BUSINESS CENTER UNIT 204

P.O. BOX 5050 OTTOVILLE ROAD

PAGO PAGO, AS 96799

UNIT 203

UNIT 205

9'16'

UP

STORAGE ROOM

99 SQFT

EXAM ROOM

49 SQFT

'-4

5'

-6

5'

5'-7"

SECURITY

ROOM

18 SQFT

4'-6"

4'

LEGEND:

DATA

QUAD ELECTRIC OUTLET

42" MONITOR

POWER OUTLET

BEHIND MONITOR

DOCUMENT:

FOR APPROVAL

DRAWING NO:

BLDG. NAME

DRAWING TITLE:

LOCATION SITE:

PROJECT:

AS - BUILT

FOR DETAIL

FOR CONSTRUCTION

CONTRACTOR

CLIENT /OWNER

FOR PROPOSAL

FOR PRE-APPROVAL

DESIGN CONSULTANCY

TONY'S CONSTRUCTION

P.O. Box 5050

AMERICAN SAMOA

96799

NAVY BUILDOUT PROJECT

MBC UNIT 204

OTTOVILLE, AMERICAN SAMOA

DATA AND POWER LAYOUT

3/4

FOR APPROVAL:

SIGN AND PRINT NAME

NAVY RECRUITMENT

1. Is this adequate data and electric outlets?

2. Do we need telephone lines? If so, where would you like those?

ADD CAT-6/5 OUTLET FOR VOIP

ADD CAT-6/5 OUTLET FOR VOIP

YES

No need since VOIP will be installed

7/24/2024

BALCONY

78 SQFT

MOSSOOI BUSINESS CENTER UNIT 204

P.O. BOX 5050 OTTOVILLE ROAD

PAGO PAGO, AS 96799

UNIT 203

UNIT 205

9'16'

UP

STORAGE ROOM

99 SQFT

EXAM ROOM

49 SQFT

'-4

5'

-6

5'

5'-7"

SECURITY

ROOM

18 SQFT

4'-6"

4'FC

U

K B

TU

A

CC

U

DOCUMENT:

FOR APPROVAL

DRAWING NO:

BLDG. NAME

DRAWING TITLE:

LOCATION SITE:

PROJECT:

AS - BUILT

FOR DETAIL

FOR CONSTRUCTION

CONTRACTOR

CLIENT /OWNER

FOR PROPOSAL

FOR PRE-APPROVAL

DESIGN CONSULTANCY

TONY'S CONSTRUCTION

P.O. Box 5050

AMERICAN SAMOA

96799

NAVY BUILDOUT PROJECT

MBC UNIT 204

OTTOVILLE, AMERICAN SAMOA

AC LAYOUT

4/4

FOR APPROVAL:

SIGN AND PRINT NAME

NAVY RECRUITMENT

1. Is this the correct location for the AC system? YES, bigger BTU (CAPACITY) so it will cover the Security room too.

7/24/2024

PLAN 1 OF 4.pdf
Layout1
PLAN 2 OF 4.pdf
Layout1
PLAN 3 OF 4.pdf
Layout1
PLAN 4 OF 4.pdf
Layout1