Exhibit D Floor Plan.pdf
PDF 418 KB Posted
- Solicitation number
- DACA845250001500
About this file
This file contains architectural floor plans for a Navy Recruitment office buildout project at MBC Unit 204 in Ottoville, American Samoa. The plans consist of 4 sheets showing different layouts: floor plan, CCTV/intercom layout, data/power layout, and AC layout. The space includes a 415 sq ft main Navy office, 99 sq ft storage room, 49 sq ft exam room, 18 sq ft security room, and a 78 sq ft balcony.
The plans detail specific requirements including wire shelving in storage areas, louvered pocket doors, CAT-6/5 outlets for VOIP phones, a 42" monitor installation with power outlet behind it, a 24K BTU AC unit to cover both main office and security room, and CCTV camera placement for full office coverage. The contractor is identified as Tony's Construction of American Samoa, and the plans are dated July 24, 2024 for approval. The drawings include specific construction specifications like 5/8" Type X gypsum board and 3-5/8" metal studs at 16" on center.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DACA845250001500 RLP.pdf | ||
| Exhibit C Proposal to Lease.xlsx | XLSX spreadsheet | |
| Exhibit A Recruiting Form L100.pdf | ||
| Exhibit E Construction Specifications.pdf | ||
| Exhibit G Janitoiral Specifications.pdf | ||
| Exhibit B Form 3517B General Clauses.pdf | ||
| Exhibit H Certificate of Authorization.pdf | ||
| Exhibit J Seismic Forms.pdf | ||
| Exhibit I Agency Agreement.pdf | ||
| DACA845250001500 RLP.pdf | ||
| Exhibit F Construction Bid Worksheet.xlsx | XLSX spreadsheet |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NAVY OFFICE
415 SQFT
BALCONY
78 SQFT
UNIT 203
UNIT 205
9'16'
UP
LEGEND:
8" TYPE X GYP BD EA OR 1 SIDE 3-5/8" METAL STUDS @ 16" OC,
PAINT. ADDITIONAL 12" FROM EXISTING CEILING HEIGHT
EXISTING WALL
STORAGE ROOM
99 SQFT
EXAM ROOM
49 SQFT
'-4
5'
-6
5'
5'-7"
SECURITY
ROOM
18 SQFT
4'-6"
4'
DOCUMENT:
FOR APPROVAL
DRAWING NO:
BLDG. NAME
DRAWING TITLE:
LOCATION SITE:
PROJECT:
AS - BUILT
FOR DETAIL
FOR CONSTRUCTION
CONTRACTOR
CLIENT /OWNER
FL
FOR PRE-APPROVAL
DESIGN CONSULTANCY
TONY'S CONSTRUCTION
P.O. Box 5050
AMERICAN SAMOA
96799
NAVY RECRUITMENT
NAVY BUILDOUT PROJECT
MBC UNIT 204
OTTOVILLE, AMERICAN SAMOA
FLOOR PLAN
1/4
Wire Shelving per construction specs
Wire Shelving per construction specs j3pp9alc Callout louvered pocket door j3pp9alc Line j3pp9alc Line j3pp9alc Text Box
JP-8Z
PT-1210N
SMP5PM
NAVY OFFICE
415 SQFT
BALCONY
78 SQFT
MOSSOOI BUSINESS CENTER UNIT 204
P.O. BOX 5050 OTTOVILLE ROAD
PAGO PAGO, AS 96799
UNIT 203
UNIT 205
9'16'
UP
STORAGE ROOM
99 SQFT
EXAM ROOM
49 SQFT
'-4
5'
-6
5'
5'-7"
SECURITY
ROOM
18 SQFT
4'-6"
4'
42" MONITOR
JP-DV
AC-10S
EL-12S
JP-4MED
TRAINING GRAPHICS
EXTENDED CORDS
CUT-OFF
SWITCH
POWER OUTLET
BEHIND MONITOR
DOCUMENT:
FOR APPROVAL
DRAWING NO:
BLDG. NAME
DRAWING TITLE:
LOCATION SITE:
PROJECT:
AS - BUILT
FOR DETAIL
FOR CONSTRUCTION
CONTRACTOR
CLIENT /OWNER
FOR PROPOSAL
FOR PRE-APPROVAL
DESIGN CONSULTANCY
TONY'S CONSTRUCTION
P.O. Box 5050
AMERICAN SAMOA
96799
NAVY BUILDOUT PROJECT
MBC UNIT 204
OTTOVILLE, AMERICAN SAMOA
CCTV AND INTERCOM LAYOUT
2/4
FOR APPROVAL:
SIGN AND PRINT NAME
NAVY RECRUITMENT
1. Mark where you would like the entry phones. He has marked 1, but is that correct? Mark the location for the 2nd phone.
2. Coverage from the CCTV cameras. The back corner is a little weird, but I dont think we can go through the ceiling to put a camera facing the front door.
3. It looks like he has the 42' CCTV monitor in the correct location.
4. Do you need wood backing for an additional TV for the Navy? If so, where would you like that or will it be placed on a piece of furniture?
Hope they can so it will cover the entire office space, if not, relocate by test room facing the front door.
YES-50" will cover a lot of wall and loose space for the graphics
Please see comm install additional phone with extended cord.
WOOD BACKING ON
THIS WALL FOR TV
7/24/2024******** See attached updated entry system & CCTV/ NVR system components. I believe the older system components are referenced on the floor plan.
romeo.cruz1 Sticky Note 2ND Entry Phone with extended cable
BALCONY
78 SQFT
MOSSOOI BUSINESS CENTER UNIT 204
P.O. BOX 5050 OTTOVILLE ROAD
PAGO PAGO, AS 96799
UNIT 203
UNIT 205
9'16'
UP
STORAGE ROOM
99 SQFT
EXAM ROOM
49 SQFT
'-4
5'
-6
5'
5'-7"
SECURITY
ROOM
18 SQFT
4'-6"
4'
LEGEND:
DATA
QUAD ELECTRIC OUTLET
42" MONITOR
POWER OUTLET
BEHIND MONITOR
DOCUMENT:
FOR APPROVAL
DRAWING NO:
BLDG. NAME
DRAWING TITLE:
LOCATION SITE:
PROJECT:
AS - BUILT
FOR DETAIL
FOR CONSTRUCTION
CONTRACTOR
CLIENT /OWNER
FOR PROPOSAL
FOR PRE-APPROVAL
DESIGN CONSULTANCY
TONY'S CONSTRUCTION
P.O. Box 5050
AMERICAN SAMOA
96799
NAVY BUILDOUT PROJECT
MBC UNIT 204
OTTOVILLE, AMERICAN SAMOA
DATA AND POWER LAYOUT
3/4
FOR APPROVAL:
SIGN AND PRINT NAME
NAVY RECRUITMENT
1. Is this adequate data and electric outlets?
2. Do we need telephone lines? If so, where would you like those?
ADD CAT-6/5 OUTLET FOR VOIP
ADD CAT-6/5 OUTLET FOR VOIP
YES
No need since VOIP will be installed
7/24/2024
BALCONY
78 SQFT
MOSSOOI BUSINESS CENTER UNIT 204
P.O. BOX 5050 OTTOVILLE ROAD
PAGO PAGO, AS 96799
UNIT 203
UNIT 205
9'16'
UP
STORAGE ROOM
99 SQFT
EXAM ROOM
49 SQFT
'-4
5'
-6
5'
5'-7"
SECURITY
ROOM
18 SQFT
4'-6"
4'FC
U
K B
TU
A
CC
U
DOCUMENT:
FOR APPROVAL
DRAWING NO:
BLDG. NAME
DRAWING TITLE:
LOCATION SITE:
PROJECT:
AS - BUILT
FOR DETAIL
FOR CONSTRUCTION
CONTRACTOR
CLIENT /OWNER
FOR PROPOSAL
FOR PRE-APPROVAL
DESIGN CONSULTANCY
TONY'S CONSTRUCTION
P.O. Box 5050
AMERICAN SAMOA
96799
NAVY BUILDOUT PROJECT
MBC UNIT 204
OTTOVILLE, AMERICAN SAMOA
AC LAYOUT
4/4
FOR APPROVAL:
SIGN AND PRINT NAME
NAVY RECRUITMENT
1. Is this the correct location for the AC system? YES, bigger BTU (CAPACITY) so it will cover the Security room too.
7/24/2024
| PLAN 1 OF 4.pdf |
| Layout1 |
| PLAN 2 OF 4.pdf |
| Layout1 |
| PLAN 3 OF 4.pdf |
| Layout1 |
| PLAN 4 OF 4.pdf |
| Layout1 |
File details come from the government source that posted it. Updated .