This document appears to be the Exhibit C - Facility Security Level II Requirements for a federal contract opportunity. It outlines additional security requirements for a Facility Security Level II space, including specifications for facility entrances, lobbies, common areas, parking, security systems, building structure, and cybersecurity. Key details include:

The Lessor is responsible for providing countermeasures outlined in the document, as well as any additional items identified during a post-award risk assessment, which shall be priced as Building Specific Amortized Capital (BSAC). Requirements cover areas such as access control, screening, securing critical areas, restricting public access to building components, signage, landscaping, parking, security systems, building structure, and cybersecurity protections for building automation and control systems. The Lessor must also cooperate with the Facility Security Committee and implement construction security plans.

The related federal contract opportunity is for the Department of Veterans Affairs to lease medical office space for a Community Based Outpatient Clinic in Freeport, Illinois. The requirement is set aside for Service-Disabled Veteran-Owned Small Businesses, with a lease term of 20 years (10 years firm, 10 years soft), and an estimated award date before September 30, 2024.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDITIONAL SECURITY REQUIREMENTS –

FACILITY SECURITY LEVEL II

THESE PARAGRAPHS CONTAIN ADDITIONAL SECURITY REQUIREMENTS THAT

ACCOMPANY THE LISTED SPECIFICATIONS IN ATTACHMENT D OF THE AGENCY

SPECIFIC REQUIREMENTS, AND, UNLESS INDICATED OTHERWISE, ARE TO BE PRICED

AS PART OF THE BUILDING SPECIFIC AMORTIZED CAPITAL (BSAC).

NOTE THAT ITEMS IDENTIFIED AS “SHELL *” REPRESENT A LESSOR’S OBLIGATIONS

OR THE GOVERNMENT’S RIGHTS AND ARE NOT NECESSARILY ITEMS TO BE

CONSTRUCTED.

DEFINITIONS:

Definitions are the same as those used in the Lease unless re-defined in these Security Requirements.

DESIGN-BASIS THREAT – The Design-Basis Threat (DBT) is the profile and estimate of the threats to a Government facility across a range of specific undesirable events, and serves as the basis for determining appropriate security standards. The Lessor’s technical consultant(s) shall work in conjunction with the Government, including the Federal Protective Service (FPS), to apply the DBT to the post-award risk assessment. The risk assessment identifies recommended countermeasures and security design features that achieve the minimum baseline level of protection for a particular facility. The baseline level of protection may be further customized to address facility-specific conditions. The Lessor is responsible for providing countermeasure provisions outlined in this FSL document, as well as for additional items identified during the post-award risk assessment. Any additional countermeasures identified during this assessment shall be priced as BSAC.

I. FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-PUBLIC,

AND UTILITY AREAS.

A. FACILITY ENTRANCES AND LOBBY

1. EMPLOYEE ACCESS CONTROL AT ENTRANCES (SHELL)

The Lessor shall provide key or Physical Access Control System (PACS) for the entrance to this building and to doors identified by the Government as employee entrance doors.

B. SCREENING REQUIREMENTS

1. ACCOMODATION OF RETAIL/MIXED USE SPACE (SHELL)

The Lessor shall accommodate publicly accessible retail and mixed uses through such means as separating entryways.

C. COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS

1. SECURING CRITICAL AREAS (SHELL)

The Lessor shall secure areas designated as Critical Areas to restrict access to authorized personnel only, and post signage accordingly:

a. Roofs with HVAC systems and access to interior space from the roof shall also be secured with high-security (UL437) locks.

b. Lessor shall protect the ventilation equipment and system controls from unauthorized access.

2. PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD MEMBERS

The Government reserves the right to remove this countermeasure requirement, post-award, based on building-specific conditions. For measurement purposes, standoff shall be considered building support space and not ABOA.

a. RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL LOAD MEMBERS: For partitions separating public space from federal space, the Lessor shall use construction materials which have inherent ductility, and which are able to respond to load reversals. Alternatively, the Lessor can use a minimum standoff of at least 100 mm (4 inches).

b. RESTRICT CONTACT FROM MAIL AREA WITH PRIMARY VERTICAL LOAD MEMBERS: In the partitions that separate public mail screening and receiving areas from federal tenants, the Lessor shall use construction materials which have inherent ductility, and which are able to respond to load reversals.

Alternatively, the Lessor can use a minimum standoff of at least 150 mm (6 inches).

II. SITES AND EXTERIOR OF THE BUILDING

A. SIGNAGE

1. POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL (SHELL)

The Lessor shall not post sign(s) or otherwise identify the facility and parking areas as a Government, or specific Government tenant, occupied facility, including during construction, without written Government approval.

2. POSTING OF REGULATORY SIGNAGE (SHELL)

The Government may post or request the Lessor to post regulatory, statutory, sensitive areas and site-specific signage.

B. LANDSCAPING AND ENTRANCES

1. LANDSCAPING REQUIREMENTS (SHELL)

Landscaping shall be neatly trimmed to minimize the opportunity for concealment of individuals, packages/containers, and parking areas. If Landscaping exists, the Lessor shall provide trees, hedges, berms, or any combination of these to create buffer zones to separate public areas and other functions.

2. HAZMAT STORAGE (SHELL)

Where applicable, Lessor shall locate HAZMAT storage in a restricted area or storage container away from loading docks, entrances, and uncontrolled parking.

3. PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES (SHELL)

Trash receptacles, containers, mailboxes, FedEx-UPS boxes, vending machines, or other fixtures and/or features that could conceal packages, briefcases, or other portable containers shall be located away from building exterior and entry points.

C. PARKING

1. PUBLIC ACCESS TO GOVERNMENT PARKING AREAS (SHELL)

Lessor shall designate Government employee and visitor parking areas.

III. SECURITY SYSTEMS

A. SECURITY SYSTEM TESTING AND MAINTENANCE CRITERIA

The Lessor in consultation and coordination with a security provider, either internal or external, as determined by the Lease Contracting Officer, and the Government security representative shall implement a testing and preventive maintenance program for all security systems the Lessor has installed. Testing must be based on established, consistent, agency-specific protocols, to be determined at the time of design. All testing shall be documented. Operational performance testing shall be conducted annually, and functional testing shall be conducted more frequently, as determined by the Government.

Components which fail, either during testing or throughout the life of this lease shall be repaired or replaced by the Lessor within a reasonable timeframe as determined by the Government.

B. VIDEO SURVEILLANCE SYSTEM

The Lessor shall comply with FAR 52.204-25: Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment (Nov 2021). See https://www.acquisition.gov/far/part-52#FAR_52_204_25

C. INTRUSION DETECTION SYSTEM

Basic Security-in-Depth IDS shall be connected to and monitored at a central station operated by the Department of Homeland Security Mega Center. Emergency notification lists shall be coordinated with the monitoring station to include all applicable Government and lessor points of contact, including law enforcement (Federal Protective Service and facility security force). Monitoring shall be designed to facilitate a real-time detection of an incident, and to coordinate an active response to an incident. The Lessor must complete the Mega Center Alarm Requirements (MAR) application process specified by the Government to meet the monitoring requirements for a functional IDS. The Government creates an FPS monitoring account and works with the Lessor to complete the Mega Center Alarm Requirement (MAR) in conjunction with the installing security vendor. Components which fail or require maintenance, or which fail during testing shall be serviced in accordance with the Security System Maintenance Criteria listed above.

D. SECURITY SYSTEMS DESIGN

The Lessor, in consultation and coordination with security providers (internal or external) and the agency designated security representative, shall ensure at the time of system design, system construction, and throughout the term of the Lease, that alarm and PACS panel, VSS components, controllers, and cabling shall be secured from unauthorized physical and logical access.

IV. STRUCTURE

NOTE: FOR ADDITIONAL BLAST RESISTANT MEASURES REQUIRED IN NEW LEASE

CONSTRUCTION PROJECTS, REFER TO LEASE PARAGRAPH “SECURITY FOR NEW

CONSTRUCTION”.

A. WINDOWS

1. LOCK GROUND FLOOR WINDOWS

If the Government occupies ground floor space in the Building, the Lessor shall provide a means to lock all operable, ground floor windows with secure latches. As part of BSAC, any operable, ground floor windows shall be monitored via IDS.

B. BUILDING SYSTEMS

1. EMERGENCY GENERATOR PROTECTION (T.I.)

If an emergency generator is required by the Government, the Lessor shall locate it, either pre-existing or installed as part of Tenant Improvements, in a secure area, protected from unauthorized access and vehicle ramming, if outdoors. The emergency generator and its fuel tank must be located at least 25 feet from loading docks, entrances, and parking areas. Alternatively, if the 25-foot distance cannot be achieved, Lessor shall protect utilities in accordance with the post-award DBT analysis through a combination of standoff, hardening, and venting methods.

2. SECURING AIR INTAKE GRILLES

Lessor shall secure all accessible air intake grills from tampering or removal. Whenever possible, locate outdoor air intakes at least 30 feet above grade, and preferably at roof level.

V. OPERATIONS AND ADMINISTRATION

A. FACILITY SECURITY COMMITTEE (SHELL *)

The Lessor shall cooperate and work with the buildings Facility Security Committee (FSC) throughout the term of the Lease. The FSC is responsible for addressing facility-specific security issues and approving the implementation of security measures and practices.

The FSC consists of representatives of all Federal tenants in the facility, the security organization, and the leasing department or agency.

B. CONSTRUCTION SECURITY PLAN (SHELL)

The Lessor shall develop and implement a construction security plan. The plan should specify who is responsible for the security of the site during each phase of the project until final completion. The construction security plan shall describe in detail, how the Government’s information, assets, equipment, and personnel will be protected during the construction process. (This shall include background checks, restrictions on accessibility, and escorts for the construction personnel). The required security measures will vary with the risk presented during the project. The Lessor shall also submit a security plan for all post-occupancy construction and alterations projects in the leased Space, throughout the term of this Lease.

VI. CYBERSECURITY (SHELL *)

A. Lessors are prohibited from connecting any portion of their building and access control systems (BACS) to any federally-owned or operated IT network. BACS include systems providing fire and life safety control, physical access control, building power and energy control, electronic surveillance, and automated HVAC, elevator, or building monitoring and control services (including IP addressable devices, application servers, or network switches).

B. In the event of a cybersecurity incident related to BACS, the Lessor shall initially assess the cyber incident, identify the impacts and risks to the Building and its occupants, and follow their organization’s cyber and IT procedures and protocols related to containing and handling a cybersecurity incident. In addition, the Lessor shall immediately inform the Lease Contracting Officer’s (LCO’s) designated representative, i.e., the Lease Administration Manager (LAM), about cybersecurity incidents that impact a federal tenant’s safety, security, or proper functioning.

C. Lessors are encouraged to put into place the following cyber protection measures to safeguard facilities and occupants:

1. Engineer and install BACS to comply with the Department of Homeland Security Industrial Control Systems Computer Emergency Response Team (DHS ICS- CERT) cyber security guidance and recommendations (https://ics-cert.us-cert.gov/Recommended-Practices).

2. Refer to the National Institute of Standards and Technology Cyber Security Framework (NIST-CSF) (https://www.nist.gov/cyberframework) and cybersecurity guidance in the DHS Commercial Facilities Sector-Specific Plan (https://www.dhs.gov/publication/nipp-ssp-commercial-facilities-2015) for best practices to manage cyber risks.

3. Encourage vendors of BACS to secure these devices and software through the following:

a. Develop and institute a proper Configuration Management Plan for the BACS devices and applications, so that the system can be supported.

b. Safeguard sensitive data and/or login credentials through the use of strong encryption on devices and applications. This means using NIST- approved encryption algorithms, secure protocols (i.e., Transport Layer Security (TLS) 1.1, TLS 1.2, TLS 1.3) and Federal Information Processing Standard (FIPS) 140-2 validated modules.

c. Disable unnecessary services in order to protect the system from unnecessary access and a potential exposure point by a malicious attacker. Examples include File Transfer Protocol-FTP (a protocol used for transferring files to a remote location) and Telnet (allowing a user to issue commands remotely).

Additionally, use of protocols that transmit data in the clear (such as default ZigBee) should be avoided, in favor of protocols that are encrypted.

d. Close unnecessary open ports to secure against unprivileged access.

e. Monitor and free web applications and supporting servers of common vulnerabilities in web applications, such as those identified by the (Open Web Application Security Project (OWASP) Top 10 Project (https://www.owasp.org/index.php/Category:OWASP_Top_Ten_Project).

f. Enforce Least Privilege, where proper permissions are enforced on a device or application so that a malicious attacker cannot gain access to all data.

Enforcing Least Privilege will only allow users to access data they are allowed to see. Additional information can be found at https://www.beyondtrust.com/blog/what-is-least-privilege/.

g. Protect against Insufficient User Access Auditing, where device or application does not have a mechanism to log/track activity by user. Enforce changing of factory default Username and Password to prevent unauthorized entry into the BACS system.

h. Use updated antivirus software subscription at all times. Kaspersky-branded products or services, prohibited from use by the Federal Government, are not to be utilized.

i. Conduct antivirus and spyware scans on a regular basis. Patching for workstations and server Operating System (OS), as well as vulnerability patching should follow standard industry best practices for software development life cycle (SDLC).

j. Discontinue the use of end of life (EOL) systems and use only applications/systems that are supported by the manufacturer.

k. Operating Systems must be supported by the vendor for security updates (e.g., do not use Windows Server 2003).

l. Proposed standard installation, operation, maintenance, updates, and/or patching of software shall not alter the configuration settings from the approved United States Government Configuration Baseline (USGCB) or tenant agency guidance (if applicable).

m. Disallow the use of commercially-provided circuits to manage building systems and install building systems on a protected network, safeguarded by the enterprise firewalls in place. Workstations or servers running building monitor and control systems are not connected and visible on the public internet.

n. Systems should have proper system configuration hardening and align with Center for Internet Security (CIS) benchmarks or other industry recognized benchmarks. Additional information can be found at https://www.cisecurity.org/cis-benchmarks/.