Exhibit C.pdf

PDF 756 KB Posted

Attached to
Locking Ring Billet
Solicitation number
SPMYM326Q1101
Issued by

About this file

This DD Form 1423-1 (Contract Data Requirements List) details data submission requirements for a Locking Ring Billet contract (PR No. 52744403) with multiple data items requiring vendor documentation. The five specific data items are: (C001) Certificate of Compliance for Quality, (C002) Chemical & Mechanical Certification Data/Report, (C003) Heat Treatment Results Test/Inspection Report, (C004) Non-Destructive Testing (UT) Procedure Approval, and (C005) UT Results/Report. Each data item must be submitted one time, with most submissions required to be made with the material or prior to specific testing, and distributed to the Purchasing Activity using codes 133.2 or 135T. The vendor must follow specific technical guidelines from referenced documents like NAVSEA technical publications and specific drawing notes, and submit quantitative test results in the units specified by the contract requirements.

View the file

Other files

File Type Posted
Security Agreement For NNPI.pdf PDF
Exhibit B.pdf PDF
RFQ SPMYM326Q1101.pdf PDF
Exhibit A.pdf PDF
Clauses - Full Text Provisions and Clauses 250423.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD FORM 1423-1 (FACSIMILE) PAGE 1 of 3

CONTRACT DATA REQUIREMENTS LIST

245.2X-1766-25 (2 DATA ITEMS)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

C

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

LOCKING RING BILLET

E. CONTRACT/PR NO.

52744403

F. CONTRACTOR

1. DATA ITEM NO.

C001

2. TITLE of DATA ITEM

CERTIFICATE OF COMPLIANCE

3. SUBTITLE

CERTIFICATION OF QUALITY

COMPLIANCE

4. AUTHORITY (DATA Item Description Number)

DI-MISC-81356A

5. CONTRACT REFERENCE

SECTION C.2

6. REQUIRING OFFICE

CODE 245

7. DD 250 REQ

DD

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

One Time

12. DATE OF 1st

SUBMISSION

With Material

14. DISTRIBUTION

a. ADDRESSEE b. COPIES

DRAFT FINAL

8. APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

CODE 133.2 0 1 0

16 REMARKS

1. Technical content as described in the respective contract line item(s).

2. For payment & submission of data refer to clauses 252.232-7006 & 252.232-

7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number.

15. TOTAL 0 1 0

1.DATA ITEM NO.

C002

2 TITLE of DATA ITEM

CERTIFICATION DATA / REPORT

3. SUBTITLE

CHEMICAL & MECHANICAL

CERTIFICATION

4. AUTHORITY

DI-MISC-80678

5. CONTRACT REFERENCE

SECTION C.3

6. REQUIRING OFFICE

CODE 245

7. DD 250 REQ

DD

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

One Time

12. DATE OF 1st

SUBMISSION

With Material

14. DISTRIBUTION

a. ADDRESSEE b. COPIES

DRAFT FINAL

8. APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

CODE 133.2 0 1 0

16 REMARKS

1. Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.

2. Technical content as described in the respective contract line item(s).

3. This certification shall contain the actual test results of all chemical & mechanical test(s) required by the specification

4. The test result(s) shall be quantitative & in the units required by the specification.

5. For payment & submission of data refer to clauses 252.232-7006 & 252.232-

7003 or 52.232-36. Each data item submitted by vendor must be submitted under a separate shipment number.

6. In addition to the certification data requirements specified in DI-MISC-80678, the requirements of the contract section titled, “Marking and Certification requirements for Controlled Industrial Material” apply.

15. TOTAL 0 1 0

0014-0015

SPMYM326Q1101

245.2X-1766-25 (1 DATA ITEM)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

C

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

LOCKING RING BILLET

E. CONTRACT/PR NO.

52744403

F. CONTRACTOR

1 DATA ITEM NO.

C003

2 TITLE of DATA ITEM

TEST/ INSPECTION REPORT

3 SUBTITLE

(HEAT TREATMENT RESULTS)

4 AUTHORITY (DATA Item Description Number)

DI-MISC-80678

5 CONTRACT REFERENCE

SECTION C. 4

6 REQUIRING OFFICE

PURCHASING ACTIVITY

7. DD 250 REQ

DD

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

One Time

12. DATE OF 1st

SUBMISSION

WITH MATERIAL

14. DISTRIBUTION

a. ADDRESSEE b. COPIES

DRAFT FINAL

8 APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

CODE-133.2 0 1 0

16 EMARKS

- 1.Paragraphs 10.2.2, 10.2.3 & 10.4 of DI-MISC-80678 do not apply.

- VENDOR SHALL SUBMIT THEIR RESULTS OF THE HEAT-TREATMENT PER NOTE

7005 OF DWG 7106787 REV-XC & NOTE 7014 OF DWG 7066792/XD.

0 0 0

15. TOTAL 0 1 0

1. DATA ITEM NO.

C004

2 TITLE of DATA ITEM

NDT (UT) PROCEDURE APPROVAL

3 SUBTITLE

(UT) PROCEDURE

4 AUTHORITY (DATA Item Description Number)

UDI-T-23732-B

5 CONTRACT REFERENCE

SECTION C. 5

6 REQUIRING OFFICE

PURCHASING ACTIVITY

7. DD 250 REQ

LT

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

One Time

12. DATE OF 1st

SUBMISSION

PRIOR TO ANY UT

14. DISTRIBUTION

a. ADDRESSEE b. COPIES

DRAFT FINAL

8APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

CODE-135T 0 1 0

16 EMARKS

- PARA # 10.1 OF UDI-T-23732-B DO NOT APPLY.

- VENDOR’S UT PROCEDURE. TO BE VENDOR’S UT PROCEDURE IAW NAVSEA

T9074-AS-GIB-010/271-REV-1 AND NOTE 7006 OF DWG-7106787 REV-XC & NOTE 7033

OF DWG 7066792/XD. ACCEPTANCE CRITERIA TO BE PER NOTE 7006 OF DWG

7106787 REV-XC & NOTE 7033 OF DWG 7066792/XD. SUBMIT PROCEDURES TO

PNSY CODE 135T FOR REVIEW AND APPROVAL PRIOR TO PERFORMING ANY UT.

0 0 0

15. TOTAL 0 1 0

DD FORM 1423-1 (FACSIMILE) PAGE 2 of 3

0016-0017

245.2X-1766-25 (1 DATA ITEM)

A. CONTRACT LINE ITEM NO. B. EXHIBIT

C

C. CATEGORY

TDP X TM ______ OTHER______

D. SYSTEM/ITEM

LOCKING RING BILLET

E. CONTRACT/PR NO.

52744403

F. CONTRACTOR

1 DATA ITEM NO.

C005

2 TITLE of DATA ITEM

TEST/ INSPECTION REPORT

3 SUBTITLE

(UT) RESULTS / REPORT

4 AUTHORITY (DATA Item Description Number)

DI-NDTI-80809B

5 CONTRACT REFERENCE

SECTION C. 6

6 REQUIRING OFFICE

PURCHASING ACTIVITY

7. DD 250 REQ

DD

9. DIST

STATEMENT

REQUIRED

A

10. FREQUENCY

One Time

12. DATE OF 1st

SUBMISSION

With Material

14. DISTRIBUTION

a. ADDRESSEE b. COPIES

DRAFT FINAL

8APP. CODE

N/A

11. AS OF DATE

N/A

13. DATE OF

SUBSEQUENT

SUBMISSION

N/A

REG REPRO

CODE-133.2 0 1 0

16 REMARKS

- PARA #’S 10.2.2, 10.2.3.1, 10.2.4, 10.2.5, 10.2.6.2, 10.2.6.3, 10.2.6.4.2, 10.2.6.5 AND

10.2.6.6 OF DI-NDTI-80809B DO NOT APPLY.

- VENDOR SHALL SUBMIT THEIR UT TEST RESULTS IAW NAVSEA TECH PUB’S

T9074-AS-GIB-010/271 REV-1 & NOTE 7006 OF DWG 7106787 REV-XC & NOTE 7033 OF

DWG 7066792/XD.

0 0 0

15. TOTAL 0 1 0

G. PREPARED BY

JASON LAFLAMME EXT-3032

245.2X

H. DATE

09/13/25

I. APPROVED BY 245.2

9 / 2 2 / 2 0 2 5

X E D W A R D W A L S H

S i g n e d b y : W A L S H . E D W A R D . M . 1 4 1 1 0 4 8 0 3 5

J. DATE

09/22/2025

DD FORM 1423-1 (FACSIMILE) PAGE 3 of 3

File details come from the government source that posted it. Updated .