Exhibit B Waterhanlding Equipment List.pdf

PDF 441 KB Posted

Attached to
Klamath River Basin WCS, Rx Fire Engines
Solicitation number
12970224R0066
Issued by

About this file

This document appears to be an Exhibit B: Required Water Handling Equipment List for a federal contract opportunity. It details the minimum equipment requirements for a Tactical Water Tender and an Engine, including live hose reels, hoses, nozzles, adapters, tools, communication equipment, personal protective equipment, and other items. The document is related to a federal contract opportunity solicitation for Klamath River Basin WCS, Rx Fire Engines, issued by the U.S. Department of Agriculture Forest Service. The solicitation seeks water handling equipment (engines and tactical water tenders) to support prescribed fire implementation in the Klamath River Basin. The contract resources may be used for various prescribed fire activities, including unit preparation, ignition, holding, mop-up, and patrol. The Prescribed Fire Burn Boss or responsible Government Representative will administer the technical aspects of the contract.

View the file

Other files

File Type Posted
12970224R0066 RFP Q_A_ .pdf PDF
Statement of Work .pdf PDF
Exhibit C Qualfications.pdf PDF
Fire Engines - SOI.pdf PDF
SOL 12970224R0066 .pdf PDF
Exhibit A Pump capabilities.pdf PDF
Project Area Map.pdf PDF
WD 2015-5673 Rev 21.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit B: Required Water Handling Equipment List

TACTICAL WATER TENDER -- MINIMUM EQUIPMENT INVENTORY LIST

Company Name: Vehicle s/n or Unique ID:____________________

ALL resources shall have the following minimum equipment. Additional quantities or items may be carried.

List additional items in the space provided. This inventory list may be requested at any time by the government for inspection purposes.

Equipment Requirement.

Vendors are required to permanently mark their equipment inventory with vendor/company information. Acceptable markings shall be etched or engraved. Painting or marking the equipment with permanent markers is not acceptable. In addition, the vendor is to maintain a complete inventory list, including any extra items they may be carrying.

1 – Live Hose Reel min. 100’ of 1” hose non-collapsible w/3/4” inside diameter

200’ – 1 ½” cotton/synthetic hose NH thread

50’ – 2 ½” cotton/synthetic hose NH thread

20’ Suction hose with screened foot valve

1 – Spanner Wrench, combination 1 ½” to 2 ½ “

1 – Adjustable Hydrant Wrench

1 – Fire Hose Clamp 2 ½”

1 – Nozzles, comb fog/straight stream, 1 ½” NH Female

1 – Nozzle, foam 1 ½ NH

1 – Nozzle, foam ¾ NH

1 – Adapters 1 ½” NPSH Female to 1 ½” NH Male

1 – Adapters 1 ½” NH Female to 1 ½” NPSH Male

2 – Reducers 2 ½” NH Female to 1 ½” NH Male

1 – Reducer, 1 ½” NH female to 1” NPSH Male

1 – Double Male 1 ½” NH

1 – Double Female 1 ½” NH

1 – Gated Wye 1 ½” NH

2 – Shovels, size 0 or 1

2 – Pulaski’s

1 – Handheld Programmable Radio

2 - Fully charged battery packs per radio

Reflective Triangles, bi-directional, set of 3

1 – Fire Extinguisher, 2A 10BC or better

1 – First Aid Kit (5 person)

2 – each Wheel chocks (see Definitions)

1 – Flashlight

10 – Fusee’s (fire starter)

2 – Line Gear (Day Pack)

Discharge Outlets

1 – 2 ½” NH

2 – 1 ½” NH

2 ½” valve at bottom of tank with NH hose threads

Minimum 4” Dump Valve at bottom of tank (min. 34” from ground)

Updated as of: 03/04/2024 04:28 PM UTC Page: 98

Personal Protective Equipment

Nomex shirt/pants (A minimum of two full sets of flame-resistant shirt and pants per firefighter)

1 - Fire Shelter (New generation)

1 - Hardhat

1 – Pair Gloves

1 – Pair Boots

1 - Headlamp

1 – Set Hearing protection

1 – Pair Eye Protection

ENGINE -- MINIMUM EQUIPMENT INVENTORY LIST

Company Name:_________________________ Vehicle s/n or Unique ID:_____________________

ALL resources shall have the following minimum equipment. Additional quantities or items may be carried. List additional items in the space provided. This inventory list may be requested at any time by the government for inspection purposes.

D.2.1.2 -- Equipment Requirement

Vendors are required to permanently mark their equipment inventory with vendor/company information. Acceptable markings shall be etched or engraved. Painting or marking the equipment with permanent markers is not acceptable. In addition, the vendor is to maintain a complete inventory list, including any extra items they may be carrying.

1 – Live Hose Reel w/ minimum of 100’ of 1” hose non-collapsible 3/4” inside Diameter

1 ½” Hose (see table for min. quantity)

1” Hose (see table for min. quantity)

¾” Hose (see table for min. quantity)

20’ Suction hose with screened foot valve

2 – Nozzles, comb fog/straight stream, 1 ½” NH Female

2 – Nozzle, comb fog/straight stream, 1” NPSH Female

2 – Nozzle, Adjustable ¾” Garden Hose

1 – Nozzle, Foam 1 ½ NH

1 – Double Male 1 ½” NH

1 – Double Female 1 ½” NH

1 – Double Male 1” NPSH

1 – Double Female 1” NPSH

2 – Gated Wyes, 1 ½” NH

2 – Gated Wyes 1” NPSH

1 – Gated Wye ¾” Garden Hose

1 – Reducer, 2 ½” NH Female to 1 ½” NH Male

4 – Reducers, 1 ½” NH Female to 1” NPSH Male

1 – Reducer 1” NPSH to ¾” Garden Hose

1 – Adapters 1 ½” NH Female to 1 ½” NPSH Male

1 – Adapters 1 ½” NPSH Female to 1 ½” NH Male

1 – Mop-Up Wand ¾” Receptor w/ ¾” Nozzle Tip

5 – Inline Ball Valves ¾”

3 – Shovels, size “0”

3 – Pulaski’s

1 – Forestry, Fire Hose Clamp

4 – Spanner wrenches, combination (4 wrenches with 1” and 1 ½” on each wrench)

2 ea. – Programmable Radio’s at least one must be handheld with 2 additional batteries & Programming

Cable (Narrow Band Compliant)

2 – Backpack pumps

1 Gallon of drinking water

1 – First Aid Kit (5 person)

1 – Flashlight

10 – Fusee’s (fire starter)

3 – Mill Bastard Files

3 – Line Gear (Day Pack)

Reflective Triangles, bi-directional, set of 3

1 – Fire Extinguisher, 2A 10BC or better

2 – each Wheel chocks (see Definitions)

Updated as of: 03/04/2024 04:28 PM UTC Page: 100

Personal Protective Equipment (for all personnel)

Nomex shirt/pants (A minimum of two full sets of flame-resistant shirt and pants)

1 - Fire Shelter (New generation)

1 - Hardhat

1 – Pair Gloves

1 – Pair Boots

1 - Headlamp

1 – Set Hearing protection

1 – Pair Eye Protection

Discharge Outlets

1 ea. 1 ½” discharge valve full flow, rapid shut off

Pump Accessories (If Pump Powered by Auxiliary Engine)

Wrench, Adjustable 10”

Wrench, Spark Plug (Unless adjustable wrench is suitable)

1 Pliers (Slip Joint)

2 Quarts Crankcase Oil

1 Screwdriver (Standard Blade)

1 Screwdriver (Phillips)

1 Spare Starter Rope (If Required)

1 Grease Gun with Grease

Spark Plugs (Sufficient to replace all plugs on auxiliary pump)

Chainsaw Kit

1 chainsaw with fuel (minimum 3.0 cubic inch (49 cc) engine w/18” bar)

1 Chainsaw Kit Bag or Box to store Compliment

1 Combination Bar/Spark Plug Wrench

1 Spare Spark Plug to fit saw

1 Pint of Spare Engine Oil for Engine Fuel Mixture

1 Pair of Chaps meeting USFS Specification 6170-4F or later, or certified to NFPA 1977

1 Extra Chain to fit Saw-Bar Combo

1 Chain File

1 Felling Axe

1 Felling Wedge

1 OSHA or DOT Approved Fuel Container to hold Chainsaw

Fuel and Guide Bar Oil properly secured on vehicle

2 Sets Ear Plugs