EXHIBIT B-c Woonsocket RI Keying and Signage (1).pdf

PDF 170 KB Posted

Attached to
GSA seeking to lease office space in Woonsocket, Rhode Island
Solicitation number
3RI0123
Issued by

About this file

This is a detailed specifications document (Exhibit B-c) for signage, doors, and keying requirements for an SSA office facility project in Woonsocket, RI dated 12/10/24. The document outlines requirements for brushed chrome signs with black engraved letters, including 18 6"x6" signs for customer service windows and 13 2"x10" signs for various office locations including management offices, supply rooms, and shared spaces.

The document specifies detailed door and hardware requirements for multiple door types including the reception door (with tempered glass and safety film), shared service doors, barrier wall doors, multipurpose room doors, and employee doors. Each door type has specific hardware requirements including heavy weight tamper proof hinges, door closers, card readers, and various security features. The keying system is structured in three tiers: master keys for managers (2 keys with access to all doors), subset 1 for staff (18 keys excluding manager's office and computer room), and subset 2 for guards (2 keys for public entrance and reception to shared services). All keys must be marked "Do Not Duplicate" and are restricted to government personnel only.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT B-c

PROJECT – Woonsocket RI (073) FO 12/10/24 DESCRIPTION Signage/Doors/Keying

ALL SIGNS ARE BRUSHED CHROME WITH ENGRAVED BLACK

LETTERS (none braille).

Signage Details:

18 = 6”X 6” as follows:

• CUSTOMER SERVICE WINDOWS AREA; Number signs at each location (PUBLIC side area, one above the entrance of the interviewing station. EMPLOYEE side, 1 each = above the window).

13 = 2”(H) X 10” (L) as follows:

• District Manager

• Assistant District Manager

• (2) Supply Rooms

• Multipurpose Room

• Training Room

• Computer Room

• (2)Shared Services Room

• (3) Employee Entrance

• (1) Focus Room

• Reception Public Entrance – Provide (2) 1’3” X 1’3” SSA logo on glass with reverse sandblast glass.

Doors & Hardware

• Reception Door - 3/8” tempered glass inset; provide shatter resistant film over glazing; 3 m safety window film; safety 570 or equal.

• Hardware o Heavy weight tamper proof hinges o Door operator o Wall stop o ElectroLynx harness o Door switch o Automatic power assist o Storefront lockset and emergency egress hardware

• Shared Service Doors - One way film looking in

• Hardware o Heavy weight hinges o Door closer o Silencer o Kick plate o Door stop o Gasket o Card readers

• Barrier Wall Doors - One way film looking out in the reception area

• Hardware o Heavy weight hinges o Door closer o Silencer o Kick plate o Door stop o Card reader (reception area side of the door)

• MP Rooms Door

• Hardware o Heavy weight hinges o Silencer o Kick plate o Door stop o Privacy

• DM Door

• Hardware o Heavy weight hinges o Silencer o Door stop o Office lockset o Blind

• Focus Room

• Hardware o Heavy weight hinges o Silencer o Door stop o Office lockset

• IVT Room Door

• Hardware o Heavy weight hinges o Silencer o Door stop o Door closer o Office lockset

• Restroom Doors

• Hardware o Heavy weight hinges o Silencer o Door stop o Door closer

• Supply Rooms

• Hardware o Heavy weight hinges o Silencer o Door stop o Storage lockset

• Computer Room Door

• Hardware o Heavy weight tamper proof hinges o Silencer o Door stop o Door closer o Card reader o Kick plate

• Employee Doors

• Hardware o Heavy weight tamper proof hinges o Silencer o Door stop o Door closer o Card reader o Peep hole

Keying:

Provide keys to areas within SSA space to government personnel only. All keys to the government space shall be marked “Do Not Duplicate”.

o Master – Manager, Assistant Manager - Total of 2 keys All doors within SSA space o Subset 1 – Staff Employees – Total of 18 keys All doors within SSA space EXCEPT the manager’s office and computer room o Subset 2 – Guard - Total of 2 keys

Public entrance, the door from Reception into the Shared Services Room.

File details come from the government source that posted it. Updated .