About this file

This document is a design exhibit for interior and exterior signage at the CCD Boulder Creek Building in Colorado. The exhibit provides detailed specifications and design intent for six signage installations across the project. Interior Signage #01 features back-lit lettering with a back-lit logo, requiring a junction box at the open-to-structure ceiling with blocking provided by the General Contractor and Architect. Exterior Signage #02 and #03 reference approved text from the design documents. Exterior Signage #04 includes back-lit logo and lettering mounted on a solid metal panel with a junction box provided behind the panel, with the signage vendor responsible for blocking and electrical connections. Exterior Signage #05 and #06 both feature back-lit logos and letters, with #06 requiring flush-mount conduit and a junction box from the General Contractor, and blocking provided by the signage vendor as needed.

The document establishes clear responsibility allocations among project stakeholders, with the General Contractor responsible for providing electrical infrastructure including junction boxes and conduit, while the signage vendor assumes responsibility for blocking, mounting, and final electrical connections. All exterior signage text has been approved by CCD. The specifications indicate that back-lit elements are a primary design feature across multiple installations, requiring coordination between the General Contractor's structural and electrical work and the signage vendor's installation and finishing work. No pricing, budget, or contract term information is provided in this design exhibit document.

View the file

Other files

File Type Posted
AHEC-27500-D_CCD_Interior_Exterior Signage_FINAL_TPD_8.3.26.pdf PDF
Exhibit C - Bid Document.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AJohnson12 Text Box OFOI Signage

Interior Signage #01-Refer to 11/A6.13- the logo will be back-lit, but the letters won't. GC will provide junction box at the open to structure ceiling. Architect and GC will provide blocking for this signage.

AJohnson12 Text Box Exterior Signage #02& #03- Refer to 2/A2.10, text has been approved by CCD

AJohnson12 Image

AJohnson12 Text Box Exterior Signage #04- Refer to 1/A2.10, text has been approved by CCD Junction box provided behind metal panel in the general location of the signage (signage mounted on solid metal panel-no perforations). Signage vendor will provide blocking for the signage and connection to electrical. The logo and lettering will be back-lit.

AJohnson12 Image

AJohnson12 Image

AJohnson12 Text Box #02

AJohnson12 Text Box #03

Image

Text Box Exterior Signage #05- Refer to 2/A2.10, Logo and Letters will be back-lit.

AJohnson12 Image

AJohnson12 Image

AJohnson12 Text Box Exterior Signage #06- Refer to 3/A2.10, Logo and Letter will be back-lit. GC to provide flush mount conduit and junction box to general location. Signage vendor will provide blocking if needed.