EXHIBIT-A_P2978-24 John Wetten.Seismic Evaluation Report.pdf

PDF 19 MB Posted

Attached to
A&E Seismic upgrade
Solicitation number
S-P03001-00014695
Issued by
Clackamas County, Garibaldi City, Oregon

About this file

This document is a Structural Seismic Evaluation Report prepared by ZCS Engineering & Architecture for the Gladstone School District 115, focusing on the John Wetten Elementary School Gymnasium located at 250 E Exeter St, Gladstone, OR 97027. The report details a comprehensive seismic assessment of the original 1958 gymnasium building, which is classified as a W2 (Wood Frames, Commercial and Industrial) and URM (Unreinforced Masonry Bearing Walls) structure. The evaluation was conducted using ASCE 41-17 standards to determine the building's seismic performance and identify necessary retrofit measures to meet immediate occupancy and life safety performance levels.

The total project cost is estimated at $2,598,905.00, with $98,905.00 in match funds and $2,500,000.00 requested from the Seismic Rehabilitation Grant Program (SRGP). The cost breakdown includes $1,923,300.00 for construction, $308,900.00 for engineering, $62,700.00 for construction management, and $276,405.00 for contingency. The site is located in a liquefaction hazard area, which significantly impacts the retrofit design and contributes to the higher-than-average construction costs. The evaluation identified multiple structural and nonstructural deficiencies, including inadequate load paths, insufficient wall anchoring, and potential seismic vulnerabilities that require comprehensive retrofitting to ensure the building's safety and resilience during a seismic event.

View the file

Other files

File Type Posted
JWE SRGPENGINEERING SER_RFP.pdf PDF
List of Offerors RFQ S-W912JV25C3003.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit A - Structural Seismic Evaluation Report (including Preliminary Rehabilitation Drawings) prepared by ZCS– John Wetten Elementary School Gym Seismic Rehabilitation

G0.0

COVER SHEET

JOHN WETTEN ELEMENTARY SCHOOL GYM SEISMIC RETROFIT

PRELIMINARY DESIGN

GLADSTONE SCHOOL DISTRICT 115

250 E EXETER STREET

GLADSTONE, OR 97027

STRUCTURAL REPAIRS:

S1. PROVIDE A COMPLETE, WELL-DEFINED LOAD PATH

BY INSTALLING NEW ELEMENTS AND CONNECTIONS

AS NEEDED TO TRANSFER INERTIAL FORCES FROM

ALL ELEMENTS OF THE BUILDING TO THE

FOUNDATION.

- IN-PLANE DIAPHRAGM CONNECTIONS

S2. PROVIDE SEISMIC ISOLATION JOINT TO AVOID

POUNDING OF THE TALLER STRUCTURE INTO THE

LOWER STRUCTURE. PROVIDE ALL NEW GRAVITY

FRAMING AND LATERAL RESISTING ELEMENTS AS

NECESSARY TO PROVIDE BUILDING SEPARATION.

A. CUT BACK (E) 2x ROOF FRAMING TO CREATE A

NEW SEISMIC ISOLATION GAP. PROVIDE ALL

NECESSARY ARCHITECTURAL JOINT CLOSURES.

B. CONSTRUCT A (N) 2x CONVENTIONAL WOOD

STUD SHEAR WALL. PROVIDE ALL NECESSARY

ROOF CONNECTION AND FOUNDATION

CONNECTION HARDWARE.

C. CONSTRUCT A (N) CONTINUOUS GRADE BEAM

TO SUPPORT THE NEW SHEAR WALL. PROVIDE

(N) PILE CAPS AS NECESSARY.

D. CUT BACK (E) FRAMING TO ENLARGE (E) SEISMIC

GAP CREATED DURING THE 1995 CAFETERIA

RENOVATION. ALL (E) BEARING ELEMENTS TO

REMAIN.

E. CONSTRUCT A (N) STEEL MOMENT FRAME TO

SUPPORT THE 1995 CAFETERIA RENOVATION

ROOF TO BE SEPARATED. PROVIDE NEW PILE

CAPS AND INSTALL NEW DEEP FOUNDATIONS TO

SUPPORT THE NEW MOMENT FRAME.

F. INSTALL NEW WOOD DRAG BEAMS TO CONNECT

ROOF DIAPHRAGM TO NEW MOMENT FRAMES.

S3. ANCHOR THE MEZZANINE TO THE

SEISMIC-FORCE-RESISTING ELEMENTS OF THE MAIN

STRUCTURE AND PROVIDE ADDITIONAL VERTICAL

LATERAL RESISTING ELEMENTS.

A. PROVIDE IN-PLANE ATTACHMENTS AT FLOOR

DIAPHRAGM TO MAIN STRUCTURES'

SEISMIC-FORCE-RESISTING ELEMENTS.

B. INSTALL NEW SHEAR WALLS BELOW

MEZZANINE FLOOR.

S4. PROVIDE DEEP FOUNDATIONS SOLUTIONS. PROVIDE

PILE AND PILE CAPS AS REQUIRED.

S5. INSTALL NEW PLYWOOD SHEATHING ON UPPER HALF

OF EXISTING WALLS TO ENSURE ADEQUATE SHEAR

CAPACITY.

S6. BOLT SHEAR WALL END STUDS TO EXISTING

CONCRETE PILASTERS.

S7. INSTALL NEW PLYWOOD DIAPHRAGM SHEATHING

BELOW THE EXISTING 4x ROOF DECKING.

S8. INSTALL NEW PLYWOOD DIAPHRAGM SHEATHING

BELOW THE EXISTING 4x ROOF DECKING.

S9. INSTALL NEW CONCRETE SHEAR WALLS TO REDUCE

THE SHEAR STRESS IN THE ADJACENT EXISTING

CONCRETE FRAME.

S10. INSTALL NEW CONCRETE SHEAR WALLS TO

REPLACE EXISTING URM WALLS TO MEET FORCE

DEMANDS.

S11. INSTALL NEW OUT-OF-PLANE ANCHORAGE.

S12. INSTALL NEW HARDWARE FOR TRANSFER OF

SEISMIC FORCES FROM DIAPHRAGM TO SHEAR

WALLS.

S13. INSTALL NEW CONCRETE SHEAR WALLS IN-LINE OF

THE EXISTING CONCRETE SHEAR WALLS TO MEET

FORCE DEMAND.

S14. INSTALL NEW CONCRETE SHEAR WALLS TO REDUCE

THE SHEAR WALL ASPECT RATIO.

S15. PROVIDE NEW DRAG ELEMENTS AT REENTRANT

CORNERS.

S16. PROVIDE NEW CONTINUOUS CROSS TIES BETWEEN

DIAPHRAGM CHORDS.

S17. STRENGTHEN EXISTING MASONRY SHEAR WALL

LINES TO MEET SEISMIC FORCE DEMANDS.

A. INSTALL NEW CONCRETE SHEAR WALLS TO

REPLACE EXISTING URM WALLS.

B. INSTALL NEW WOOD FRAMED SHEAR WALLS TO

REPLACE THE EXISTING GYPSUM SHEAR

WALL INFILLS.

S18. REDUCE THE UNSUPPORTED LENGTH OF THE

EXISTING SLENDER URM WALLS.

A. INSTALL NEW STEEL STRONGBACK COLUMNS TO

RESIST OUT-OF-PLANE FORCES.

B. INSTALL NEW STEEL SPANDRELS TO RESIST

OUT-OF-PLANE FORCES.

S19. RETROFIT AND STRENGTHEN BEAMS TO SUPPORT

CODE REQUIRED VERTICAL SEISMIC LOADING.

NON-STRUCTURAL REPAIRS:

N1. REMOVE GLAZING AND REPLACE WITH NEW SAFETY

GLASS WINDOWS SYSTEM.

N2. SEISMICALLY ANCHOR EXISTING CANOPIES TO THE

STRUCTURE.

-OUT-OF-PLANE CONNECTIONS

N3. REMOVE SUSPENDED ITEMS OR ENSURE THAT ITEMS

ARE FREE TO SWING FROM STRUCTURE WITHOUT

DAMAGING THEMSELVES OR ADJOINING

COMPONENTS.

N4. INSTALL BRACING FOR ALL ROUND DUCTS LARGER

THAN 28 IN. IN DIAMETER.

REPAIR KEYNOTES

TRUE/PROJECT

NORTH

*SITE PLAN NOT

TO SCALE

BUILDING KEY PLAN

VICINITY MAP

G0.0 COVER SHEET

S1.1 AREA A FOUNDATION PLAN

S1.2 AREA A MEZZANINE FRAMING PLAN

S2.1 AREA A ROOF FRAMING PLAN

SHEET INDEX

PROJECT

LOCATION

AREA A:

ORIGINAL GYMNASIUM 1958

±9,200 S.F.

IMMEDIATE OCCUPANCY

W2, C2a, & URM

PROJECT NO:

DRAWN:

CHECKED:

DATE:

O N

E

IN

C H

E Q

U

AL

S

FU

LL

S

C

AL

E

GLADSTONE SCHOOL

DISTRICT 115

250 E EXETER STREET,

GLADSTONE, OR 97027

JOHN WETTEN

ELEMENTARY

SCHOOL GYM

SEISMIC RETROFIT

PR

EL

IM

IN

AR

Y

D

ES

IG

N

DEC. 2024

KNT

JRE

P-2978-24

-P

RELIM

IN

ARY-

NOT FOR C

ONSTRUCTIO

N

524 Main Street, Suite 2 Oregon City, OR 97045

503.659.2205

DATE:DESCRIPTION

AREA B:

ORIGINAL CLASSROOM

±16,500 S.F.

NOT IN SCOPE

AREA C:

MUSIC ROOM ADDITION

±5,250 S.F.

NOT IN SCOPE

AREA D:

LIBRARY AND

CLASSROOM ADDITION

±13,000 S.F.

NOT IN SCOPE

AREA E:

1995 ADDITION

±39,000 S.F.

NOT IN SCOPE

AREA E

AREA A FOUNDATION PLAN

NTS

S1.1

CAMPUS KEY

NTS

S1.1

CAMPUS KEY

NTS

S1.1

AREA C

AREA A

AREA D

AREA B

OUT OF SCOPE

OUT OF SCOPE

S4 TYP.

S4 TYP.

S4 TYP.

S4 TYP.

S2C

S9,S17A

S9,S17A

S18A TYP.

S4 TYP.

S4 TYP. S17B TYP.

S4 TYP.

S2B

S3B

S3B

S4 TYP.

S2C

S2E

S4 TYP.S10, S13, S14

S10, S13, S14

O U

T O

F

SC

O

PE

S2C

S2C

S1.1

AREA A FOUNDATION

PLAN

PROJECT NO:

DRAWN:

CHECKED:

DATE:

O N

E

IN

C H

E Q

U

AL

S

FU

LL

S

C

AL

E

GLADSTONE SCHOOL

DISTRICT 115

250 E EXETER STREET,

GLADSTONE, OR 97027

JOHN WETTEN

ELEMENTARY

SCHOOL GYM

SEISMIC RETROFIT

PR

EL

IM

IN

AR

Y

D

ES

IG

N

DEC. 2024

KNT

JRE

P-2978-24

-P

RELIM

IN

ARY-

NOT FOR C

ONSTRUCTIO

N

524 Main Street, Suite 2 Oregon City, OR 97045

503.659.2205

DATE:DESCRIPTION

CAMPUS KEY

NTS

S1.2

CAMPUS KEY

NTS

S1.2

OUT OF SCOPE

OUT OF SCOPE

AREA A CANOPY FRAMING PLAN

NTS

S1.2

AREA A MEZZANINE FRAMING PLAN

NTS

S1.2

OUT OF SCOPE

S3B TYP.

N2 TYP.

S3A TYP.

S3B TYP.

S11, S16

S3A TYP.

S11, S16

S7, S8

AREA E

AREA C

AREA A

AREA D

AREA B

S1.2

AREA A MEZZANINE

FRAMING PLAN

PROJECT NO:

DRAWN:

CHECKED:

DATE:

O N

E

IN

C H

E Q

U

AL

S

FU

LL

S

C

AL

E

GLADSTONE SCHOOL

DISTRICT 115

250 E EXETER STREET,

GLADSTONE, OR 97027

JOHN WETTEN

ELEMENTARY

SCHOOL GYM

SEISMIC RETROFIT

PR

EL

IM

IN

AR

Y

D

ES

IG

N

DEC. 2024

KNT

JRE

P-2978-24

-P

RELIM

IN

ARY-

NOT FOR C

ONSTRUCTIO

N

524 Main Street, Suite 2 Oregon City, OR 97045

AREA A ROOF FRAMING PLAN

NTS

S2.1

CAMPUS KEY

NTS

S2.1

CAMPUS KEY

NTS

S2.1

S1.2

S1.2

S19

S19

S19

S19 S11 TYP.

S5 TYP.

S7, S8

S1, S12

S11 TYP.

S18B TYP.

S18A

S1 TYP.S2AS2B

S6 TYP.

S2A S2B

S10, S13, S14

S18B TYP.

S18B

S18BS9,S17A

S11 TYP.

S1, S12

S15

S15

S10, S13, S14

S11 TYP.

S5

S1 TYP.

S2C

S1 TYP.

S2A

S7, S8

OUT OF SCOPE

OUT OF SCOPE

AREA E

AREA C

AREA A

AREA D

AREA B

S2A,S2B S9,S17A

O U

T O

F

SC

O

PE

S2B

S2E

S2D

S2F

S2F

S1, S12

S11

S11

S2.1

AREA A ROOF

FRAMING PLAN

PROJECT NO:

DRAWN:

CHECKED:

DATE:

O N

E

IN

C H

E Q

U

AL

S

FU

LL

S

C

AL

E

GLADSTONE SCHOOL

DISTRICT 115

250 E EXETER STREET,

GLADSTONE, OR 97027

JOHN WETTEN

ELEMENTARY

SCHOOL GYM

SEISMIC RETROFIT

PR

EL

IM

IN

AR

Y

D

ES

IG

N

DEC. 2024

KNT

JRE

P-2978-24

-P

RELIM

IN

ARY-

NOT FOR C

ONSTRUCTIO

N

524 Main Street, Suite 2 Oregon City, OR 97045

File details come from the government source that posted it. Updated .