This Exhibit A document provides amended specifications for a height adjustable reclining tub to be procured by the State of Idaho for use at the Idaho State Veterans Home in Pocatello, Idaho. The tub must be brand new and the manufacturer's newest model, meeting strict dimensional requirements including a length of 70 to 82 inches, width of 28 to 32 inches, and overall height of 52 to 60 inches, with an access height of 22 to 24 inches to accommodate transfers from standard powered patient lifts. The procurement requires delivery, placement, and installation of the new tub(s), though specific quantities, response deadlines, and award dates are not detailed in this specification document. The tub must operate on 110-volt hard-wired electrical connections and include both panel and hand-held pendant controls for raise/lower, tilt, and air jet functions.
The tub specifications mandate a polished fiberglass or equivalent finish in white or grey with permissible small accent colors, designed to accommodate users weighing up to 450 pounds with a safe working load of 660 pounds including water. Required features include adjustable in-tub water temperature controls, auto-fill capability, air spa/jet functionality, head and back padding, a footrest, and tilt, raise, and lower functions, with water consumption ranging from 24 to 26 gallons at pre-filled level and 58 to 62 gallons at overflow level. The manufacturer must provide standard warranty coverage and arrange warranty service and maintenance capability either onsite or through a qualified local vendor. The Idaho Veterans Services reserves the right to accept minor deviations in dimensions and connections at the discretion of the Maintenance Foreman, provided the tub properly fits the available space. No dealership insignias, reseller plates, or similar markings are permitted on the equipment.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit A Event 1213 - AMENDED
Specifications for Height Adjustable Reclining Tub(s)
The following specifications are a description of a Height Adjustable Reclining Tub, hereinafter referred to as a "Tub(s)". The Tub(s) will be used to provide quality care for the residents of the Idaho State Veterans Home in Pocatello, Idaho.
It is the responsibility of manufacturers to use materials, components, and design practices, which are the best available, and current to industry standards for the type of operating conditions which this type of Tub(s) may be subject to. All component parts of the Tub(s) shall not merely meet the minimum requirements of this specification, but be selected to give maximum performance, service life and safety of Idaho's Veterans.
A Tub(s) offered in compliance with these specifications must be brand new, not used or refurbished, and be the manufacturer's newest model. Accessories must be engineered, designed, or certified by the manufacturer to be compatible with all other components.
The Tub(s) must come with a standard manufacture warranty and have warranty service and future maintenance onsite or with a local vendor that has the ability and qualifications to repair or service the Tub(s).
Minor deviations of the dimensions and connections may be accepted after a review by the Maintenance Foreman for acceptance, as long as the deviations allow the Tub(s) to properly fit in the space available.
If deviations are outside the space available as deemed solely by the Maintenance Foreman, bid may not be considered. IDVS reserves the right to determine minor deviations.
1. Dimensions
1.1 Length – Acceptable overall length may be no shorter than seventy (70") inches and no more than eight-two (82") inches.
1.2 Width – Acceptable overall width may be no less than twenty-eight (28") inches and no more than thirty-two (32") inches.
1.3 Height – Acceptable overall height may be no shorter than fifty-two (52") inches and no taller than sixty (60") inches.
1.4 Access height must be twenty-two (22") to twenty-four (24") inches to accommodate transfer from standard powered patient lifts.
1.5 Seat height, when lowered must be a minimum of twenty-two (22") Inches and a maximum of twenty-four (24") inches.
2. Electrical Requirement
2.1 One hundred and ten (110) volt hard-wired connection
3. Construction
3.1 Finish must be polished fiberglass or equivalent to meet disinfection protocols in the facility.
3.2 Drain must be located in center of foot bed tub floor.
3.3 Plumbing temperature handling: fifty (50°) Fahrenheit – one hundred and twenty-two
(122°) Fahrenheit, accuracy +/- 1.8° Fahrenheit
3.4 Access door on left side of the user in the tub.
3.5 Exterior must be white or grey. Small accent colors are acceptable.
4. Controls
4.1 Must include panel (on unit) and hand-held (pendant) controls.
4.2 Raise/Lower, Tilt, and Air jet control functions must be adjustable on panel and held-held controls.
5. Capacity
5.1 Must accommodate users weighing ≥ four hundred and fifty (450) lbs.
5.2 Safe working load (patient + water) ≥ six hundred and sixty (660) lbs.
5.3 Water consumption at pre-filled/autofill level must be no less than twenty-four (24) gallons and no more than twenty-six (26) gallons.
5.4 Water consumption at overflow level must be no less fifty-eight (58) gallons and no more than sixty-two (62) gallons.
6. Other Features (must include)
6.1 In-tub water temperature adjustable temperature controls
6.2 Auto Fill
6.3 Handicap Accessible
6.4 Air spa/Air jet functionality
6.5 Head and back padding/cushions
6.6 Footrest
6.7 Tilt, Raise, and Lower functions.
7. Miscellaneous
7.1 No dealership, reseller plates, insignias or emulsions adhered to Tub(s).
7.2 Delivery, placement and installation of new Tub(s) are required.