Exhibit 2 RD810 Barbed and Woven Wire Fences.pdf

PDF 632 KB Posted

Attached to
software solution that encompasses tour management, and room reservations
Solicitation number
S-15600-00011853
Issued by
Marion County, Oregon

About this file

This file is a standard drawing specification (RD810) for barbed and woven wire fences issued by the Oregon Department of Transportation and referenced in the Oregon Standard Drawings effective December 1, 2024 through May 31, 2025. The document provides detailed technical specifications and design standards for the construction of barbed wire and woven wire fencing systems used in Oregon transportation infrastructure projects. The drawing includes three fence types (Type 1, Type 1-5W, and Type 2) with specifications for wire gauge, post materials, spacing configurations, and gate construction details. Materials must comply with ASTM A-702 and AASHTO M 181 standards, with options for both wood and metal posts depending on project conditions. Wooden stays are required in areas experiencing heavy snowfall or snow drifts exceeding 36 inches. The specifications detail line post spacing, brace configurations, concrete footing requirements, and anchor plate dimensions, with comprehensive dimensional tables provided for post sizes, weights, and structural members.

The document establishes minimum specifications for materials including Douglas Fir, Western Pine, or Hemlock for wooden components and ASTM A-702 steel for metal members. Fence construction varies based on the radius (R) dimension, with different bracing unit requirements applied at intersections with existing fence lines and at gate or corner posts. Ground line wire must include a minimum of four barbed wires or woven wire fabric stapled to posts, with horizontal wires spaced according to fence type specifications. The drawing references related standard drawings including RD820 for fence gate details and incorporates general engineering principles and practices under the responsibility of the selecting engineer. No pricing, budget allocation, or procurement timeline information is contained within this technical specification document, which serves as a reference standard for engineers and contractors implementing fencing projects within Oregon's transportation system.

View the file

Other files

File Type Posted
RFI Reservation Event Management.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RD810

FENCES

BARBED AND WOVEN WIRE

R D

.d g n

13-JAN-2020N/A

J U

L xxxxxxxxxxxx x x x x x xxxxx x x x x x xxxxxx x x xxx x xx x xx x x x x x x x x x x x x xxxxx x x x x x x x x x x x xxxxxxx x x x x x x x xxx xx x x x xx x xxx xxxxx x x x x x x x x x x x x x xxx x x x xx x x x x x x xx xx x x x x x x xx x x x x x x xx

B

C

WIRES

NO. OF

10"

14"

10"

12"

Type 1-5W

Type 1

1 1

SQUARE

SHAPE

a a a a b b

FENCE C SPACING

stake

1"x2"x12"

Lever metal posts)

(See wood or

Gate post from end of locking bar.

post and approx. 5" welded or bolted to gate

" short link coil chain4 line post material)

4'-4" (Metal

End bar Length

3" normal

Gate post

6 gauge thkn. wire loop wood line post material)

Length 4'-4" (Metal or

End bar

6 gauge thkn. wire loop

3" normal m in m in

Ground linewire loop

6 gauge thkn.

line post material) approx.2'-2" (Metal

Locking bar

Fence stays gauge wire2

6 gauge thkn. wire loop

30" (Type 2)

(33' max. for type 2 fence material)

Width as indicated on plan

5'-6" max. 5'-6" max. 5'-6" max.

3 For wooden stays, see Type 1 fence details.

2 For details not shown see fence type.

1 Match adjointing fence type.

Fence material Fence material Fence materialNOTES:

thkn. wire gauge2

Fence stays

4 or 5 barbed wires

2" min.

Ground line

Post

NOTE:

1 5'-6" 5'-6" ta b le b e lo w

F o r s p a c in g s e e for woven wire fabric.

Horizontal wires to be stapled are: single wires and a minimum of 4 wires on the ground.

Hemlock or Western Pine, spaced as shown for wire stays and to rest firmly

Stays to be 2"x2"x52" min. length, sound, untreated Douglas Fir, Western

Wooden Stays to be used in areas of heavy snowfall or snow drifts over 36".

wire fabric

Rectangular woven

832-6-12

Design number details see Type 1 fence

For wooden stays, NOTE:

Recommendation R9-47.

Simplified Practice

U.S. Dept. of Commerce

Post2

"Barbed wire

Ground line

Unit A required at gate post.

fence line at intersection with new fence line.

Either Unit A or Units A & B are required in existing

Over 330

20-330

20 or Less

Types

1-5W &

1, A & B

A

None

FENCE

R

(ft) REQUIRED

UNITS

TABLE 1 (For wood posts)

TABLE 2

TABLE 3

3" to 4"

All Types 660' 16'-6" 7'-6" 6'-6" 4'-4" 3'-2" 2'-2" 7'-8" 9"-22"

ASTM A-7021.33 lb or U-bar

Tee Channel 3"x3"3"Line Post

Brace Rail

Brace or

"2 to 5

"2

Other Post 4" to 7" 5"

4"

5"x5"

4"x4" Tubular

Angle

Tubular

Angle

3.19 lb b

4.1 lb "4

"x2

"x22

" O.D.8

"4

2"x2"x

" +/- O.D.2 min.-max. min. avg.

FENCE

max.

R P min.

L min.

L H min.

D min.

D min.

B min.-max.

X

MEMBER

SMALL END (in)

DIAMETER OF

ROUND

(in) nominal

SIZE

nominal

PER (ft)

WEIGHT

nominal

SIZE

WOOD METAL

Max. taper 1":48".

in each dimension.

Max. allowable size 1" additional

In accordance with ASTM A 702.

In accordance with AASHTO M 181.

corner post unit

End, gate or m in

12"

Brace min.

Concrete footing min.

nom. wt. 0.67 lbs

Anchor plate footing

Concrete

Brace

Line post

Intermediate end post line

Ground

Brace min.

18" min.

min.

2"

D H

L

X

B

P

R

B

X

H

L

D

12"

H D

L

22" round

20" sq. or

22" round

18" sq. or

22" round

20" sq. or

22" round

18" sq. or

2"

2"

8'-3"8'-3"

Wood brace rail steel dowel

"dia. x4"8

Wood post

Brace post thkn. wire

4 stands of 9 gauge

Brace guys Brace post

Brace rail Intermediate end post

3. For cross sectional dimensions of members see Table 3.

2. Line post spacing same as dimension P.

1. For dimensions indicated by letter see Table 2.

NOTES:

1"x2"x12" stake

Lever

8'-3" 8'-3"

R

P

H

L

D

D

L

H

Brace post

D

L

H

UNIT A UNIT B

For units required see Table 1 corner post unit(s)

End, gate or

Brace rail wire

9 gauge thkn.

4 strands of

Brace guy guy at gate posts

Additional brace line

Ground

Line post

21 21 21

GATEWAY

TYPES 1 , & 1-5W

BRACE RAIL CONNECTIONMETAL POSTS

WOOD POSTS

TYPE 2

TYPE 2TYPE 1-5WTYPE 1

7. Add fence grounding as required.

6. See project plans for details not shown.

5. See Std. Dwg. RD820 for fence gates.

4. All concrete shall be commercial grade concrete.

3. For shapes, weights and dimensions of members see Table 3.

2. Line post spacing same as dimension P.

1. For dimensions indicated by letter see Table 2.

GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:

TABLE OF DIMENSIONS

the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2024 - May 31, 2025

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

EXHIBIT 2

File details come from the government source that posted it. Updated .