Exhibit 2 (Plans).pdf

PDF 5 MB Posted

Attached to
RFQ for Brand Awareness and Brand Assets (PCS# 520200-00817-RFQ)
Solicitation number
S-580501-00008248
Issued by
Lane County, Oregon

About this file

This is a technical drawing/exhibit document prepared by the Oregon Department of Transportation for the Huntington Sand Shed Fencing Project, as part of the Oregon Statewide Imagery Program (OSIP). The document provides detailed plans and specifications for the removal of an existing gate and fence, with replacement of a 32-foot wide gate constructed of Schedule 40 galvanized steel pipe. The project involves removing the existing gate (approximately 32 feet wide consisting of two 16-foot panels hung on 8-inch steel posts) and installing a new gate with specified inset distances of approximately 60 feet on one side and 20 feet minimum on the other side. The drawing includes a gate detail specification sheet noting that all materials shall comply with current Oregon Standard Specifications, and provides technical specifications for the gate construction including 8-inch Schedule 40 galvanized steel pipe with end cap, finished grade chain link fabric, Schedule 40 galvanized steel pipe braces equally spaced with 5-foot embedment and concrete backfill. The new gate is designed to match the existing fence height and include a gate lock and latch mechanism.

No additional pricing, timeline, set-asides, incumbent information, funding sources, or contract terms are specified in this technical drawing document. The document is designated as Sheet 1 of 1 at Not-to-Scale (NTS) and includes a standard disclaimer noting that the selection and use of this standard drawing, while designed in accordance with generally accepted engineering principles and practices, is the sole responsibility of the user and should not be used without first consulting a Registered Professional Engineer.

View the file

Other files

File Type Posted
Procurement Information~19.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Oregon Statewide Imagery Program (OSIP) - Oregon Imagery Framework Implementation Team

OREGON DEPARTMENT OF TRANSPORTATION

Huntington Sand Shep Fencing Project New Gate

File Date

Remove existing fence.

Add new gate and hardware Existing gate is approximately 32 feet wide (two 16 foot panels) hung on 8 inch steel posts.

Inset gate approximately 60 FT on one side and 20 FT minimum on the other

Existing gate see gate detail for post size and embedment details

Remove existing fence and replace with a 32 foot gate

NTS

Latch detail

All materials shall be in accordance with the current Oregon Standard Specifications.

Gate Detail

SIZE FSCM NO DWG NO REV

SCALE NTS SHEET 1 OF 1

All materials shall be in accordance with the current Oregon Standard Specifications.

Gate Detail

SIZE FSCM NO DWG NO REV

SCALE NTS SHEET 1 OF 1

Huntington Sand Shed Gate Detail

The selection and use of this Standard Drawing, while designed in accordance with generally accepted engineering principles and practices, is the sole responsibility of the user and should not be used without first consulting a Registered Professional Engineer.

8 inch Schedule 40 GALV Steel Pipe with end cap

Finished grade chain link fabric

Schedule 40 galv. steel pipe brace (Typ.)

Brace(s) to be equally spaced

5 FT embedment with concrete backfill

32 FT Gate

Match existing fence Hight

Provide gate lock/Latch

TextText

Text

Huntington Sand Shed (1)
gate detail
gate detail.vsdx
Page-1