About this file
This procurement document is a Scope of Work from Cuyahoga County Public Safety & Justice Services (PSJS) for the acquisition of thermal protection equipment for public safety diving operations. The county seeks competitive quotes for twenty-nine (29) complete thermal protection packages, each consisting of one one-piece thermal drysuit undergarment and one compatible thermal diving hood. The equipment is specifically designed for use in cold-water rescue, recovery, and underwater operations, including ice-diving applications, and must be new and unused. The undergarments must feature one-piece, full-body design with high-performance insulation, breathable materials for moisture management, flexibility for unrestricted movement, and compatibility with Viking, Aqualung, White's, or similar contaminated water-rated drysuits. The thermal hoods must be constructed of breathable, flexible thermal insulating materials suitable for cold-water and ice-diving operations while accommodating standard diving masks and regulators. Final sizing distribution will be determined after purchase order award, with the vendor coordinating directly with PSJS to obtain the specific size breakdown. All quotes must include product and item part numbers, and bidders must provide firm unit pricing for all available sizes with no additional charges for sizing variations.
Delivery must be included in the quote price and directed to Fairview Park Fire Department located at 20777 Lorain Road, Fairview Park, Ohio 44126, with the county reserving the right to inspect all items upon delivery and reject any equipment that does not conform to specifications. The manufacturer must provide a minimum one-year warranty against defects in materials and workmanship, with the warranty beginning upon acceptance of the delivered equipment. No specific pricing terms, set-asides, incumbent information, or funding sources are detailed in this procurement document.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Event 7416 - THERMAL DRYSUIT UNDERGARMENTS
PUBLIC SAFETY DIVE OPERATIONS
SCOPE OF PROCUREMENT
Cuyahoga County Public Safety & Justice Services seeks quotes for twenty-nine (29) complete thermal protection packages for public safety diving operations.
Each package shall consist of:
• One (1) one-piece thermal drysuit undergarment.
• One (1) compatible thermal diving hood.
The equipment shall be specifically designed for use beneath a diving drysuit and provide thermal protection during cold-water rescue, recovery, and underwater operations, including ice-diving operations.
All equipment shall be new, unused, and suitable for repeated use in professional public safety diving environments.
ONE-PIECE THERMAL DRYSUIT UNDERGARMENT
The proposed undergarment shall meet or exceed the following minimum requirements:
A. Garment Design and Construction
• One-piece, full-body thermal undergarment designed specifically for use beneath a diving drysuit, providing coverage of the torso, arms, and legs.
• High-performance insulating construction designed for cold-water and ice-diving applications.
• Breathable materials designed to manage moisture and perspiration during extended diving operations.
• Construction shall provide flexibility, comfort, and unrestricted movement.
• Suitable for use under Viking, Aqualung, White’s or similar contaminated water-rated drysuits.
B. Thermal Performance
• Specifically designed, manufacturer-rated, or manufacturer-approved for cold-water and ice-diving operations.
• Provide substantial thermal insulation suitable for extended public safety diving operations.
• Insulation shall maintain thermal performance during normal use and repeated compression beneath a drysuit.
• Garment shall provide effective thermal protection without excessive bulk that restricts mobility or drysuit fit.
• Manufacturer documentation shall be provided demonstrating suitability for cold-water and ice-diving operations.
C. Fit and Functionality
• Full-length front entry zipper or equivalent design allowing convenient donning and removal.
• Design shall minimize garment movement, bunching, or displacement while donning a drysuit.
• Wrist and ankle retention features, or equivalent design, shall maintain proper garment positioning.
• Garment shall accommodate normal diving movements, including swimming, bending, and equipment operation.
• Design shall accommodate standard drysuit accessories and equipment, including P-valve systems where applicable.
COMPATIBLE THERMAL DIVING HOOD
Each undergarment shall be supplied with one (1) compatible thermal hood meeting or exceeding the following requirements:
• Specifically designed for cold-water scuba diving and ice-diving operations.
• Constructed of breathable, flexible thermal insulating materials that provide heat retention and moisture management.
• Designed for use with a diving drysuit and compatible with the proposed thermal undergarment.
• Provide thermal coverage of the head and neck while maintaining proper diving equipment fit.
• Accommodate a standard diving mask and regulator without restricting fit, function, or operation.
• Available in multiple sizes to accommodate different diver head sizes.
• Manufacturer sizing charts and fitting guidance shall be provided.
The hood shall be supplied as part of the complete thermal protection package. A standard neoprene diving hood alone will not satisfy this requirement unless it meets the thermal performance and compatibility requirements specified above.
QUANTITY AND SIZING
Item Quantity
One-piece thermal drysuit undergarment 29
Compatible thermal diving hood 29
Total complete packages 29
Because of differences in sizing profiles, the final distribution of undergarment and hood sizes will be determined following the Purchase Order award. Quote submission must include product/item part number for verification of meeting the noted specifications/capabilities above.
The awarded vendor shall coordinate with PSJS to obtain the final size breakdown before the order is finalized.
Bidders shall provide firm unit pricing for all available sizes. No additional charges shall be assessed for variations in standard garment or hood sizing.
DELIVERY AND ACCEPTANCE
Delivery cost must be included in the quote if the cost will be charged at invoicing. Use the following as delivery location. Any change to this location will remain within Cuyahoga
County;
Fairview Park Fire Department, 20777 Lorain Rd., Fairview Park, OH 44126
The purchasing agency reserves the right to inspect all items upon delivery and reject equipment that does not conform to the specifications or approved bid submission.
WARRANTY
The manufacturer shall provide a minimum one-year warranty against defects in materials and workmanship. The warranty shall begin upon acceptance of the delivered equipment.