Parameter Detail Requirement Test Method
Low Pressure (Altitude)
Storage Sea level to 50,000 ft @ - 57°C
MIL-STD-810G Method 500.5 Procedure I
Operational Sea level to 40,000 ft @ - 54°C
MIL-STD-810G Method 500.5 Procedure II
Explosive Decompression 8,000 ft to 23,100 feet in 8ms
MIL-STD-810G Method 500.5 Procedure IV
High Temperature extremes
Storage, cyclic +95°C MIL-STD-810G Method 501.5 Procedure I
Operational, cyclic +55°C MIL-STD-810G Method 501.5 Procedure II
Operational, constant +71°C for 30 Minutes MIL-STD-810G Method 501.5 Procedure II
Low Temperature extremes
Storage, cyclic -57°C MIL-STD-810G Method 502.5 Procedure I
Operational, cyclic -40°C MIL-STD-810G Method 502.5 Procedure II
Operational, sea level, constant
-65°C for 120 Minutes MIL-STD-810G Method 502.5 Procedure II, as per F-16
Temperature Shock, from constant -54°C to +71°C at 125°C/Minute
MIL-STD-810G Method 503.5 Procedure I-B
Combined temperature-altitude-humidity
Operational, 10 cycles -40°C to +71°C, Sea level to 60,000 ft
MIL-STD-810G Method 520.3 Procedure III
Humidity Operational and Non-Operational, aggravated cycle
95% ± 4% Humidity, +30°C to +60°C, 10 cycles
MIL-STD-810F Method 507.5 Procedure II
Sand and Dust Operational and Non-Operational, blowing
< 150um dust, 150um to 850um sand
MIL-STD-810G Method 510.5 Procedure I (Dust) Procedure II (Sand)
Rain Operational, Dripping 7 gal/ft2/hr, 40 mph for 30 minutes
MIL-STD-810G Method 506.5 Procedure III
Fungus Non-Operational 7-day growth MIL-STD-810G Method 508.6
Salt Fog Operational and Non-Operational, exposure
Four 24-hour wet/dry cycles
MIL-STD-810G Method 509.5
Explosive Atmosphere
Operational At site and 40,000 ft altitudes
MIL-STD-810G Method 511.5 Procedure I
Acceleration, structural
Limit Loads Performance at ±10.0g applied individually along all 3 axes
MIL-STD-810G Method 513.6 Procedure I
Ultimate Loads
Withstand without structural failure ±15.0g applied individually along all 3 axes
MIL-STD-810F Method 513.6 Procedure II
Crash Landing Remain captive, 40g fore, 20g aft and down, 10g up, 18g left and right
MIL-STD-810F Method 513.6 Procedure III
Shock – Functional
Operational
20g, 11ms nominal, 3 blows each direction, each axis (18 total), terminal peak sawtooth
MIL-STD-810G Method 516.6 Procedure I
Shock – Crash Hazard
Non-Operational 40g, 11ms nominal, 2 blows each direction, each axis (12 total)
MIL-STD-810G Method 516.6, Procedure V
Shock – Bench Handling
Non-Operational 4” drop, 1 drop per edge per face (24 total)
MIL-STD-810G Method 516.6, Procedure VI
Vibration
Operational, Performance, Jet aircraft
30 mins, 0.02 g2/Hz to
0.04 g2/Hz, 15 - 2000 Hz, Overall 4.4Grms
MIL-STD-810G Method 514.6, Procedure I, Category 12, Annex D, Fig 514.6D-I
Non-Operational, Endurance, Jet aircraft
60 mins, 0.04 g2/Hz to
0.06 g2/Hz, 15 - 2000 Hz, Overall 9.2Grms
MIL-STD-810G Method 514.6, Procedure I, Category 12, Annex D, Fig 514.6D-I
Operational, Gunfire Shock
7.5 min sweeps, 5 to 15 g, 66 to 856 Hz
MIL-STD-810G Method 519.6, Procedure III
Operational, UH-60 Main Rotor speeds and blade numbers
4 hours, 0.001g2/Hz to 0.01g2/Hz, 3 to 500 Hz
MIL-STD-810G Method 514.6, Procedure I, Category 14, Annex A & Annex D, Table 514.6D-III
Acoustic Noise Operational 30 mins, 140 dB overall, 50 to 10000 Hz
MIL-STD-810G Method 515.6 Procedure I
Conducted Emissions
Operational Power Leads, 30 Hz to 10 kHz
MIL-STD-461G CE101
Par 5.4, CE101-4 Curve #2
Operational Power Leads, 10 kHz to 10MHz
MIL-STD-461G CE102
Par 5.5, Fig CE102-1 Basic Curve
Conducted Susceptibility
Operational Power leads, 30Hz to 150 kHz
MIL-STD-461G CS101
Par 5.7, Fig CS101-1 Curve #2
Operational Bulk cable injection, 10 kHz to 200MHz
MIL-STD-461G CS114
Par 5.12, Fig CS114-1 Curve #5
Operational Bulk cable injection, impulse excitation, 30Hz for one minute
MIL-STD-461G CS115
Par 5.13, Fig CS115-1
Operational
Damped sinusoidal transients, cables and power leads, 10kHz to 100MHz, 5 minutes
MIL-STD-461G CS116
Par 5.14, Fig CS116-1 and CS116-2
Radiated Emissions
Operational Magnetic field, 30Hz to 100kHz
MIL-STD-461G RE101
Par 5.17, Fig RE101-1 and Fig
RE101-2
Operational Electric field, 10kHz to 18GHz
MIL-STD-461G RE102
Par 5.18, Fig RE102-3 Fixed wing external and Fixed wing internal < 25m
Radiated Susceptibility
Operational Magnetic field, 30 Hz to 100 kHz
MIL-STD-461G RS101
Par 5.20 Fig RS101-2 Army
Operational Electric field, 2 MHz to 18 GHz
MIL-STD-461G RS103
Par 5.21, Table XI, Aircraft Internal Army
Power Supply
Operational, normal condition
Load measurements, ask for info
MIL-STD-704F Chg1
MIL-HDBK-704-8 LDC-101
Operational, normal condition
Steady state limits, 22 Vdc to 29 Vdc
MIL-STD-704F Chg1
MIL-HDBK-704-8 LDC-102
Tests A, B, C
Operational, normal condition
Voltage distortion spectrum
MIL-STD-704F Chg1 Fig 15
MIL-HDBK-704-8 LDC-103
Tests A thru K
Operational, normal condition
Total ripple MIL-STD-704F Chg1 Fig 15
MIL-HDBK-704-8 LDC-104,
Table LDC104-II
Operational, normal condition
Normal voltage transients, 18Vdc to 29Vdc
MIL-STD-704F Chg1 Fig 13
MIL-HDBK-704-8 LDC-105
Tests AA thru RR
Operational, transfer interrupt
Power interrupt, 50ms, 22Vdc to 29Vdc
MIL-HDBK-704-8 LDC-201
Operational, abnormal condition
Steady state limits, 20.0 Vdc and 31.5Vdc, 30 minutes
MIL-STD-704F Chg1
MIL-HDBK-704-8 LDC-301
Tests A and B
Operational, abnormal condition
Abnormal voltage transients, abnormal condition
MIL-STD-704F Chg1 Fig 14
MIL-HDBK-704-8 LDC-302,
Tests AAA thru NNN, 7 to 50V
Operational, emergency condition
Steady state limits, 18 Vdc to 29 Vdc
MIL-HDBK-704-8 LDC-401
Operational, starting Starting voltage transients, 12 Vdc to 29 Vdc
MIL-STD-704F Chg1
MIL-HDBK-704-8 LDC-501,
Table LDC501-IV
Operational, power failure and automatic recovery
Power failure, from 100ms to 7 seconds
MIL-STD-704F Chg1
MIL-HDBK-704-8 LDC-601
Tests A thru D
Operational, power failure
Phase reversal protection/prevention
MIL-STD-704F Chg1
MIL-HDBK-704-8 LDC-602
Max Power Use
Operational, startup, all ports negotiating link
≤ 56W
Operational, steady-state, all ports on at max speed
≤ 29W
Operational, steady-state, 3 10GbE on at max speed, 4 1GbE ports on at max speed, all other ports on at 100Mbps
≤ 21W
Operational, steady-state, only 16 1GbE ports on at max speed
≤ 19W
Chassis Grounding
Operating
Allow for proper electrical bonding through designated external stub and dedicated pins on connectors
SAE-AS-50881H
Electrical Bonding
Operating
Primary Chassis ground connection for electrical bonding provided by designated external stub
MIL-STD-464C, Paragraph 5.11.3
Mounting For vibration tolerance 4x 10-32 captive screws