This document is a request for proposals (RFP) for a roof replacement project located at the Nocona MNT Facility in Nocona, Texas. The project involves the complete removal of an existing built-up roof with asbestos-containing material and insulation system down to the existing metal deck, removal of existing roof skylights, building expansion joint, and existing gutters and downspouts. The new work includes installing metal deck over the skylight openings, a new rigid board insulation system and tapered boards, a new fully adhered high-density cover board, and a new modified bitumen roof system. The project also includes installing a new building roof expansion joint, new perimeter flashings, gutters, and downspouts, as well as providing new concrete splash blocks at each downspout. The estimated cost for the project is $66,425.00, and a bid guaranty/bid bond of $1,000.00 is required. The pre-bid meeting is scheduled for January 3, 2024, at 10:00 AM CT, and bids are due on February 7, 2024, at 1:00 PM CT. The contract will be awarded by the Texas Department of Transportation (TxDOT), and the successful bidder must be registered with TxDOT's Bonfire platform to submit their proposal. The use of Historically Underutilized Businesses (HUBs) is mandated for this project, and a HUB Subcontracting Plan (HSP) must be submitted with the proposal.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
1. WORK SHALL CONFORM TO THE CONSTRUCTION DOCUMENTS &
APPLICABLE BUILDING CODES (INCLUDING FEDERAL & STATE CODES,
ORDINANCES, REGULATIONS, ETC.) CONSTRUCTION DOCUMENTS
INCLUDE DRAWINGS & SPECIFICATIONS PLUS ANY ADDENDA TO THE
AFOREMENTIONED.
2. CONSTRUCTION DOCUMENTS ARE INTENDED TO INCLUDE ITEMS
NECESSARY TO CONVEY DESIGN INTENT OF THE WORK.
MANUFACTURERS' INSTRUCTIONS SHALL BE CONSIDERED AS PART OF
THE SPECIFICATIONS WHETHER INCLUDED OR NOT IN THE
SPECIFICATION MANUAL.
3. PERIODIC SITE VISITS BY OWNER'S REPRESENTATIVE SHALL NOT BE
CONSTRUED AS SUPERVISION OF MEANS, METHODS, TECHNIQUES,
SEQUENCES OR PROCEDURES FOR CONSTRUCTION, NOR IMPLY
RESPONSIBILITY FOR PROVIDING A SAFE PLACE FOR PERFORMANCE
OF WORK BY CONTRACTOR OR CONTRACTOR'S EMPLOYEES, OR
EMPLOYEES OF SUPPLIERS, OR FOR ACCESS, VISITS, USE, WORK,
TRAVEL, OR OCCUPANCY BY ANY PERSON.
4. CONTRACTOR IS RESPONSIBLE FOR CONTINUOUS SECURITY AT
AFFECTED OPENINGS FOR THE DURATION OF THE COSNTRUCTION
CONTRACT. COORDINATE SECURITY STATUS CHANGES W/ DISTRICT
REPRESENTATIVE PRIOR TO IMPLEMENTING CHANGES.
5. CONTRACTOR SHALL:
- VERIFY DIMENSIONS & FIELD CONDITIONS BEFORE PROCEEDING.
- NOTIFY ARCHITECT OF FIELD CONDITIONS REQUIRING DEVIATIONS
FROM CONSTRUCTION DOCUMENTS BEFORE THE CONSTRUCTION
OF ANY MODIFICATION.
- PROVIDE ADEQUATE BRACING & SHORING AS NECESSARY UNTIL
PERMANENT SUPPORTS & STIFFENERS ARE INSTALLED.
- IMMEDIATELY REPAIR OR REPLACE DAMAGED OR DEFECTIVE
WORK TO THE APPROVAL OF (AND AT NO ADDITIONAL COST TO)
THE OWNER
- NOTIFY ARCHITECT & APPROPRIATE INSPECTORS AT CRITICAL
CONSTRUCTION MILESTONES IN ORDER TO OBTAIN NECESSARY
APPROVALS & INSPECTIONS PRIOR TO COMMENCEMENT OF
SUBSEQUENT WORK.
- TAKE REASONABLE PRECAUTIONS FOR THE SAFETY OF, AND
PROVIDE REASONABLE PROTECTION TO PREVENT DAMAGE,
INJURY OR LOSS TO:
a) EMPLOYEES & ALL OTHER AFFECTED PERSONS
b) ALL WORK, MATERIALS & EQUIPMENT
c) OTHER PROPERTY AT SITE OR ADJACENT THERETO.
- UPON COMPLETION OF THE WORK, REMOVE MATERIALS, TOOLS &
EQUIPMENT AND LEAVE SITE IN A CONDITION ACCEPTABLE TO
OWNER.
Support Services Division / Facilities Planning & Management
COPYRIGHT 2020 TEXAS DEPTARTMENT OF TRANSPORTATION
150 E. Stassney Lane Austin, Texas 78744-3147 c
VICINITY MAP
INDEX OF DRAWINGS
PROJECT:
Project Manager:
ARCHITECTURE:
G E
N E
R A
T E
D O
N
/5
/2
:3 :3
P
M A u to d e s k D o c s /0
W
F S
X
X X
X -X
X -X
X N
O C
O N
A M
N T
R O
O F
R E
P L C
/N o c o n a R o o f R e p la c e m e n t .r v t
N O
C O
N A
M N
T F
A C
M
N T
B U
IL
D
IN
G
P A
R T
IA
L
R O
O F
R E
P L
A C
E M
E N
T P
R O
J E
C T
N U
M B
E R
-1
-2
-0
PROJECT NUMBER: 03-1859-24-01
DAPHNE HARRIS
(512) 765-3527
DAPHNE.HARRIS@TXDOT.GOV
NOCONA MNT FAC- MNT BUILDING
PARTIAL ROOF REPLACEMENT
R.A. ALFREDO TERRONES
Phone: (512) 317-9486 E-mail: JoseAlfredo.Terrones@TXDOT.GOV
Texas Department of Transportation Support Services Division Facilities Planning & Management 6230 E. Stassney LN, Austin, TX 78744
SITE # 039541
BUILDING # 038070
729 MONTAGUE ST. (S.H.) NOCONA, TX 76255
PROJECT
LOCATION
NORTH
ARCHITECTURAL
A1.01 SITE PLAN
A2.02 PROPOSED ROOF PLAN
A2.03 ROOFING DETAILS
A2.04 ROOFING DETAILS (CONT.)
_GENERAL
G0.00 COVER SHEET
THIS PROJECT INCLUDES THE COMPLETE REMOVAL OF AN EXISTING BUILT-UP ROOF WITH ASBESTOS CONTAINING MATERIAL AND INSULATION SYSTEM DOWN TO EXISTING METAL DECK, REMOVAL OF EXISTING ROOF SKYLIGHTS, BUILDING EXPANSION JOINT AND EXISTING GUTTERS AND
DOWNSPOUTS.
INSTALLING METAL DECK OVER SKYLIGHT'S OPENINGS, INSTALLATION OF NEW RIGID BOARD INSULATION SYSTEM AND NEW TAPERED BOARDS (POLYISOCYANURATE), NEW FULLY ADHERED 1/2" H.D. COVER BOARD, INSTALLATION OF NEW MODIFIED BITUMEN ROOF SYSTEM (COLD APPLIED), BUILDING ROOF EXPANSION JOINT, NEW PERIMETER FLASHINGS, GUTTERS AND DOWNSPOUTS. PROVIDE NEW CONCRETE SPLASH BLOCK AT EACH
DOWNSPOUT.
ROOF REPLACEMENT SCOPE OF WORK: 2,236 SQ. FT.
SCOPE OF WORK:
BUILDING SUMMARY: BUILDING CODES:
INTERNATIONAL BUILDING CODE IBC - 2018
INTERNATIONAL ENERGY CONSERVATION CODE IECC - 2018
INTERNATIONAL MECHANICAL CODE IMC - 2018
INTERNATIONAL PLUMBING CODE IPC - 2018
NATIONAL ELECTRIC CODE NEC - 2020
NATIONAL FIRE CODE NFPA 1 - 2018
NATIONAL LIFE SAFETY CODE NFPA 101 - 2018
WICHITA
FALLS
BEAUMONT
PARIS
ATLANTA
BRYAN
BROWNWOOD
AMARILLO
ABILENE
CHILDRESS
FORT
WORTH
CORPUS
CHRISTI
DALLAS
EL PASO
HOUSTON
LAREDO
LUBBOCK
LUFKIN
ODESSA
SAN
ANGELO
SAN
ANTONIO
YOAKUM
WACO
TYLER
PHARR
MONTAGUE COUNTY, TX
WICHITA FALLS DISTRICT (03)
_DEMOLITION
DA2.01 EXISTING ROOF AND DEMOLITION PLAN
Date Signed: 12/06/2023
UP
EXISTING BITUMINUS
ROOFING SYSTEM
TO REMAIN
REMOVE AND
REPLACED BUILDING
EXPANSION JOINT.
REMOVE
EXISTING
BUILT-UP.
REMOVE EXISTING
BUILT-UP GRAVEL
ROOF.
REMOVE EXISTING ROOF
SKYLIGHTS (PATCH OPENING,
SEE GEN. NOTES)
EXISTING BITUMINUS
ROOFING SYSTEM
TO REMAIN
EXISTING BITUMINUS
ROOFING SYSTEM
TO REMAIN
EXISTING VENTS THROUGH
ROOF TO BE REPLACED
REMOVE EXISTING
BUILT-UP GRAVEL ROOF.
REMOVE EXISTING GUTTERS
AND DOWNSPOUTS.
REMOVE EXISTING METAL
TRIMS, FLASHING AND FASCIAS.
REMOVE EXISTING METAL TRIMS,
FLASHING AND FASCIAS.
REMOVE EXISTING METAL TRIMS,
FLASHING AND FASCIAS.
GENERAL DEMOLITION NOTES:
1. ALL ROOFING TO BE DEMOLISHED SHALL BE DISPOSED OF OFF-SITE IN A MANNER APPROVED BY THE FEDERAL, STATE, COUNTY, AND/OR JURISDICTIONAL AUTHORITY. OWNER HAS THE FIRST RIGHT OF
REFUSAL ON ALL DEMOLISHED ITEMS. CONTRACTOR SHALL COORDINATE PROPER HANDLING AND
PROMPT REMOVAL FROM THE JOB SITE OF ALL ITEMS SO AS NOT TO INTERFERE WITH OWNER'S
OPERATION.
2. ALL EXISTING CONSTRUCTION TO BE REMOVED SHALL BE REMOVED CAREFULLY SO AS NOT TO DAMAGE
ANY EXISTING CONSTRUCTION TO REMAIN. CONTRACTOR SHALL REPAIR OR REPLACE EXISTING
CONDITIONS DAMAGED DURING CONSTRUCTION AT NO ADDITIONAL COST.
3. REMOVE EXISTING GRAVEL SURFACING, BUR MEMBRANE DOWN TO EXISTING METAL DECKING
INCLUDING REMOVAL OF EXISTING METAL FLASHINGS.
4. THOROUGHLY INSPECT THE DECK, REMOVE AND REPAIR ANY DAMAGED OR DETERIORATED SUBSTRATE WITH NEW DECKING OF LIKE MATERIAL AND GAUGE. INSTALLED IN ACCORDANCE TO THE S.D.I. AND F.M.
STANDARDS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND ADEQUACY OF HIS AREA OF WORK AND METHODS. CONTRACTOR SHALL ERECT AND MAINTAIN AT ALL TIMES PROPER SAFEGUARDS AND SAFETY BARRIERS AS REQUIRED BY THE CONDITIONS AND PROGRESS OF THE WORK FOR THE PROTECTION OF WORKMEN, OWNER AND OWNER'S PROPERTY AND SHALL POST DANGER WARNINGS AGAINST HAZARDS
CREATED BY THE CONSTRUCTION OPERATIONS.
6. CONTRACTOR TO REMOVE SKYLIGHT, SKYLIGHT COMPONENTS, CURB, CURB COMPONENTS, FRAME AND
FRAME COMPONENTS.
7. FOR THE REMOVAL OF ASBESTO CONTAINING MATERIAL REFER TO ESPECIFICATION SEECTION 02 82 00
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2023c
Texas of Transportation Department
R
/5
/2
:3 :3
P
M A u to d e s k D o c s /0
W
F S
X
X X
X -X
X -X
X N
O C
O N
A M
N T
R O
O F
R E
P L C
/N o c o n a R o o f R e p la c e m e n t .r v t
DA2.01
P R
O J E
C T
N O
-1
-2
-0
DRAWN BY: DRAFTER
ISSUED: 12/06/2023
N O
C O
N A
M N
T F
A C
- M N
T B
U
IL
D
IN
G P
A R
T
IA
L R
O O
F R
E P
L A
C E
M E
N T
M O N
TA
G U E
S T
(S
.H
N O
C O
N A
T
X
M O N
TA
G U E
C O
U N
T Y
W
IC
H
IT
A F
A L L S
D
IS
T R
IC
T
EXISTING ROOF AND DEMOLITION PLAN
CHECKED BY: Checker
1/8" = 1'-0"
DEMOLITION PLAN
01 02 03 04
05 06 07
NO
RTH
Date Signed:
12/06/2023
ROOFING AREA
TO BE REPLACED
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2023c
Texas of Transportation Department
R
/5
/2
:3 :2
P
M A u to d e s k D o c s /0
W
F S
X
X X
X -X
X -X
X N
O C
O N
A M
N T
R O
O F
R E
P L C
/N o c o n a R o o f R e p la c e m e n t .r v t
A1.01
P R
O J E
C T
N O
-1
-2
-0
DRAWN BY: JR
ISSUED: 12/06/2023
N O
C O
N A
M N
T F
A C
- M N
T B
U
IL
D
IN
G P
A R
T
IA
L R
O O
F R
E P
L A
C E
M E
N T
M O N
TA
G U E
S T
(S
.H
N O
C O
N A
T
X
M O N
TA
G U E
C O
U N
T Y
W
IC
H
IT
A F
A L L S
D
IS
T R
IC
T
SITE PLAN
CHECKED BY: AT
1" = 20'-0"
SITE PLAN
NORTH
A2.03
A2.03
A2.03
A2.035
A2.03
/8
/8
/8
NEW MODIFIED
BITUMINUS ROOFING
SYSTEM
NEW MODIFIED
BITUMINUS ROOFING
SYSTEM
PROVIDE NEW GUTTERS
& DOWNSPOUTS
15' - 10 3/4"
16' - 2 29/128"
DABD
A A
NEW MODIFIED
BITUMINUS ROOF TO
REMAIN
NEW MODIFIED
BITUMINUS ROOF TO
REMAIN
6' - 0" 79' - 3"
EXISTING VTR TO
REMAIN (SEE NOTES)
EXISTING VTR TO
REMAIN (SEE NOTES)
PATCH OPENINGS OF
REMOVED SKYLIGHTS
SEE NOTE 10
EXISTING VTR TO
REMAIN (SEE NOTES)
PROVIDE NEW
EXPASION JOINT
PROVIDE NEW METAL
EDGE AND FASCIA
PROVIDE NEW METAL
EDGE AND FASCIA
LEGEND
DIRECTION OF SLOPE
SKYLIGHT
HEATER FLUE
PLUMBING / ELEC. PIPE
DOWNSPOUT
1/8" / 12"
GENERAL NOTES:
1. ALL DIMENSIONS INCLUDING SPOT ELEVATIONS, AND EXISTING DETAIL SHALL BE FIELD VERIFIED PRIOR TO BIDDING AND ACQUISITION OF MATERIALS. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY EXISTING CONDITIONS FOUND TO BE DIFFERENT THAN INDICATED IN THE CONTRACT DOCUMENTS. THE ARCHITECT SHALL REVIEW THE SITUATION AND INFORM THE
CONTRACTOR AND TXDOT PROJECT MANAGER OF NECESSARY CHANGES, IF ANY.
2. ROOF SLOPE / TAPER SHALL BE 1/8" PER FOOT MINIMUM (U.N.O.) AND SHALL SLOPE TO GUTTER OR ROOF SCUPPER.
3. ROOFING TERMINATIONS, FLASHINGS, TRANSITIONS, AND SCUPPERS SHALL BE IN STRICT ACCORDANCE TO MANUFACTURER'S INSTRUCTIONS AND GUIDELINES.
4. ROOFING INSULATION TO BE A MINIMUM OF R-25, CONTINUOUS NOT AVERAGE.
5. PER IBC 1504.5 LOW-SLOPE BUILT-UP MOD-BIT OR SINGLE-PLY ROOFING SYSTEM EDGE SECUREMENT (EXCEPT GUTTERS WHERE APPLICABLE) SHALL BE DESIGNED & INSTALLED FOR WIND LOADS IN ACCORDANCE WITH IBC CHAPTER 16 & TESTED FOR RESISTANCE IN ACCORDANCE WITH ANSI/SPRI ES-1 TEST METHODS RE-1,RE-2 & RE-3, EXCEPT V(ult) WIND SPEED SHALL BE
DETERMINED FROM IBC FIGURE 1609A, 1609B OR 1609C AS APPLICABLE.
6. AS REQD BY ANSI/SPRI ES-1, WOOD NAILERS FOR COPINGS & GRAVEL STOPS SHALL BE 1-1/2" MINIMUM THICKNESS & SECURED TO STRUCTURAL COMPONENTS OF THE BUILDING BY FASTENERS SUFFICIENT TO RESIST A VERTICAL LOAD OF 200 LBS/FT OR THE DESIGN LOAD, WHICHEVER IS GREATER. FOR WOOD NAILERS WIDER THAN 6", FASTENERS SHALL BE STAGGERED TO AVOID SPLITTING THE WOOD. EACH WOOD NAILER MEMBER SHALL HAVE AT LEAST 2 FASTENERS. A FASTENER SHALL BE LOCATED APPROX. 4" BUT NOT LESS THAN 3" FROM EACH END OF THE WOOD. ADDITIONAL WOOD MEMBERS, SUCH AS CANT STRIPS, STACKED NAILERS & SLOPED EXT. GRADE A PLYWOOD TOPS SHALL BE FASTENED WITH FASTENERS HAVING SUFFICIENT PULLOUT RESISTANCE PRIOR TO EDGE SYSTEM FAILURE. THESE FASTENERS SHALL BE STAGGERED, SPACED AT 12" O.C. MAX. IN PERIMETER REGIONS & 6" O.C. MAX. IN CORNER REGIONS & SHALL PENETRATE THE BOTTOM WOOD NAILER SUFFICIENTLY TO ACHIEVE DESIGN PULL-OUT RESISTANCE.
7. ALL WOOD LUMBER, PLYWOOD, NAILERS & BLOCKING USED AT ROOF SHALL BE PRESSURE TREATED WITH PRESERVATIVE NOTED "TREATED" THAT COMPLIES WITH SPECIFICATIONS & ROOFING MANUFACTURER'S RECOMMENDATIONS INCLUDING COMPATABILITY WITH ROOFING SYSTEM. ALL FASTENERS FOR TREATED WOOD NAILERS & BLOCKING SHALL BE CORROSION- RESISTANT & CERTIFIED BY THE FASTENER MANUFACTURER FOR USE WITH THE PRESERVATIVE TREATMENT.
8. ALL ROOF TO WALL/CURB FLASHING & PENETRATION FLASHINGS SHALL EXTEND TO 8" MINIMUM HEIGHT ABOVE THE ROOF MEMBRANE U.N.O.
9. CONTRACTOR SHALL REMOVE, PROTECT, AND REINSTALL ALL FASCIA MOUNTED LIGHT FIXTURES, CAMERAS, PRESERVE, PROTECT, AND REINSTALL FOLLOWING CONSTRUCTION.
COORDINATE WITH TXDOT PROJECT MANAGER/REPRESENTATIVE.
10. CONTRACTOR TO INSTALL NEW METAL DECK MATERIAL FROM SUPPORT TO SUPPORT. NEW ROOFING MATERIAL SHALL BE INSTALLED TO MATCH EXISTING. NEW INSULATION AND
WATERPROOF SYSTEM SHALL BE INSTALLED WITH REST OF ROOF.
KEYNOTES:
A. 1/8" PER FOOT TAPERED ISO BOARD OVER RIGID BOARD INSULATION OVER EXIST. METAL DECK.
B. NEW PREFINISHED METAL BOX GUTTER.
C. NEW 4" x 4" PREFINISHED METAL DOWNSPOUT & CONCRETE SPLASH BLOCK.
D. RADIO ANTENNA. CONTRACTOR MUST FOLLOW REQUIRED SAFETY PROCEDURES WHEN WORKING
NEAR ANTENNA. COORDINATE WORK WITH DISTRICT REPRESENTATIVE.
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2023c
Texas of Transportation Department
R
/5
/2
:3 :2
P
M A u to d e s k D o c s /0
W
F S
X
X X
X -X
X -X
X N
O C
O N
A M
N T
R O
O F
R E
P L C
/N o c o n a R o o f R e p la c e m e n t .r v t
A2.02
P R
O J E
C T
N O
-1
-2
-0
DRAWN BY: JR
ISSUED: 12/06/2023
N O
C O
N A
M N
T F
A C
- M N
T B
U
IL
D
IN
G P
A R
T
IA
L R
O O
F R
E P
L A
C E
M E
N T
M O N
TA
G U E
S T
(S
.H
N O
C O
N A
T
X
M O N
TA
G U E
C O
U N
T Y
W
IC
H
IT
A F
A L L S
D
IS
T R
IC
T
PROPOSED ROOF PLAN
CHECKED BY: AT
1/8" = 1'-0"
ROOF PLAN
NO
RTH
NEW EDGE METAL (PROFILE AND SIZE WILL
VARY) SET IN SBS ROOFING CEMENT &
SECURE W/ FASTENERS @ 3" O.C.
STAGGERED.
PRIME & STRIP IN METAL FLANGE WITH 1
LAYER TYPE IV FOLLOWED BY 1 LAYER OF
GRANULED SURFACE MODIFIED BITUMEN
NEW WOOD BLOCKING TO MATCH
THICKNESS OF NEW INSULATION.
NEW CONTINUOUS 22 GA. GALV. CLEAT.
SECURE W/ FASTENERS @ 12" O.C., TYP.
NEW COLD APPLIED GRANULE SURFACED SBS
CAP SHEET INSTALLED OVER TWO COLD-
APPLIED SBS BASE SHEETS
NEW POLYISOCYANURATE INSULATION,
TAPERED INSULATION & COVERBOARD
6 1/8" MIN.
EXISTIN G METAL DECK
M
IN
NEW TWO LAYERS OF
SPECIFIED RIGID INSULATION
& TAPERED INSULATION
6" MIN.
NEW EDGE METAL (PROFILE AND SIZE
WILL VARY) SET IN SBS ROOFING CEMENT
& SECURE W/ FASTENERS @ 3" O.C.
STAGGERED.
PRIME & STRIP IN METAL FLANGE WITH 1
LAYER TYPE IV FOLLOWED BY 1 LAYER OF
GRANULED SURFACE MODIFIED BITUMEN
NEW WOOD BLOCKING TO
MATCH THICKNESS OF
NEW INSULATION.
NEW CONTINUOUS 22 GA.
GALV. CLEAT. SECURE W/
FASTENERS @ 12" O.C., TYP.
NEW COLD APPLIED GRANULE SURFACED
SBS CAP SHEET INSTALLED OVER TWO
COLD-APPLIED SBS BASE SHEETS
NEW POLYISOCYANURATE INSULATION,
TAPERED INSULATION & COVERBOARD
EXISTIN G METAL DECK
M
IN
NEW TWO LAYERS OF
SPECIFIED RIGID INSULATION
& TAPERED INSULATION
NEW ½" COVER BOARD OVER INSULATION
MECHANICALLY FASTENED THROUGH
(ATTACHMENT MUST BE IN ACCORDANCE
WITH WIND UPLIFT REQUIREMENTS)
END VIEW OF EXPANSION JOINT
NEW RETURN MOD. BIT CAP
SHEET AT BOTH ENDS OF
EXPANSION JOINT- TYPICAL
M
IN
NEW FLASHING PER MFR
TERMINATE 6" OC AND 3-
COURSE (NOT SHOWN)
NEW CURB TO CURB
EXPANSION JOINT. ATTACH
WITH GASKETED FASTENERS
AT 12" OC THROUGH VERTICAL
LEG PENETRATING A MIN OF
1.25" INTO THE WOOD NAILER
AND INTO NAILER BENEATH
THE EXPANSION JOINT FLANGE
AT 12" OC
NEW TWO LAYERS OF
SPECIFIED RIGID INSULATION
& TAPERED INSULATION
NEW POLYISOCYANURATE
INSULATION, TAPERED
INSULATION
NEW GRANULE SURFACED
MODIFIED BITUMEN ROOFING
SYSTEM OVER COVER BOARD
EXISTING METAL DECK
NEW ½" COVER BOARD OVER
INSULATION MECHANICALLY
FASTENED THROUGH
(ATTACHMENT MUST BE IN
ACCORDANCE WITH WIND
UPLIFT REQUIREMENTS)
NEW EDGE METAL (PROFILE AND
SIZE WILL VARY) SET IN SBS
ROOFING CEMENT & SECURE W/
FASTENERS @ 3" O.C. STAGGERED.
PRIME & STRIP IN METAL FLANGE
WITH 1 LAYER TYPE IV FOLLOWED
BY 1 LAYER OF GRANULED
SURFACE MODIFIED BITUMEN
NEW WOOD BLOCKING TO MATCH
THICKNESS OF NEW INSULATION, TYP.
NEW COLD APPLIED GRANULE
SURFACED SBS CAP SHEET
INSTALLED OVER TWO COLD
APPLIED SBS BASE SHEETS
NEW POLYISOCYANURATE INSULATION,
TAPERED INSULATION & COVERBOARD
MIN.
6"
NEW EDGE METAL (PROFILE AND SIZE
WILL VARY) SET IN SBS ROOFING
CEMENT & SECURE W/ FASTENERS @
3" O.C. STAGGERED.
PRIME & STRIP IN METAL FLANGE
WITH 1 LAYER TYPE IV FOLLOWED
BY 1 LAYER OF GRANULED
SURFACE MODIFIED BITUMEN
NEW WOOD BLOCKING TO MATCH
THICKNESS OF NEW INSULATION.
NEW CONTINUOUS 22 GA. GALV.
CLEAT. SECURE W/ FASTENERS @
12" O.C., TYP.
NEW COLD APPLIED GRANULE SURFACED SBS
CAP SHEET INSTALLED OVER TWO COLD-
APPLIED SBS BASE SHEETS
NEW POLYISOCYANURATE
INSULATION, TAPERED INSULATION
& COVERBOARD
EXISTIN G
METAL DECK
NEW GRANULE SURFACED
MODIFIED BITUMEN ROOFING
SYSTEM OVER COVER BOARD
NEW WOOD FIBER OR
PERLITE CANT STRIP
FLASHING PER MFR
NEW GALVANIZED METAL
COUNTERFLASHING ANCHORED TO
EXISTING EXTERIOR WALL FASTENED WITH
GASKETED NAIL-IN ANCHORS @ 12" OC.
NEW AP SEALANT @ EXPANSION
JOINT/WALL INTERFACE
NEW POLYISOCYANURATE
INSULATION & COVERBOARD
M
IN
NEW TWO LAYERS OF
SPECIFIED RIGID INSULATION
& TAPERED INSULATION
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2023c
Texas of Transportation Department
R
/6
/2
:5 :2
P
M A u to d e s k D o c s /0
W F
S X
X X
X -X
X -X
X
N
O C
O N
A M
N T
R O
O F
R E
P L
C
/N o c o n a R o o f R e p la c e m e n t
.r v t
A2.03
P R
O J E
C T
N O
-1
-2
-0
DRAWN BY: JR
ISSUED: 12/06/2023
N O
C O
N A
M N
T F
A C
- M N
T B
U
IL
D
IN
G P
A R
T
IA
L R
O O
F R
E P
L A
C E
M E
N T
M O N
TA
G U E
S T
(S
.H
N O
C O
N A
T
X
M O N
TA
G U E
C O
U N
T Y
W
IC
H
IT
A F
A L L S
D
IS
T R
IC
T
ROOFING DETAILS
CHECKED BY: AT
3" = 1'-0"
METAL EDGE W.GUTTER @ BUILDING PERIMETER DET.
3" = 1'-0"
METAL EDGE @ BUILDING PERIMETER DET.
3" = 1'-0"
EXPASION JOINT DET.
3" = 1'-0"
METAL EDGE @ CANOPY
3" = 1'-0"
WALL FLASHING @ CANOPY
3"
35°
1"
T Y
P
DOWNSPOUT ATTACHED
TO BUILDING STRUCTURE -
TYPICAL
DOWNSPOUT
STRAP
BUILDING
EDGE
TOP OF SIDEWALK OR
BUILDING FOUND.SPLASH BLOCK
EXTEND DOWNSPOUT
PAST BOTTOM OF
OVERHANG AS
DIMENSIONED - TYPICAL
BUILDING OVERHANG
GUTTER PROFILE AS
DIMENSIONED -
TYPICAL
BUILDING
EDGE
DOWNSPOUT ATTACHED
TO BUILDING
STRUCTURE - TYPICAL
DOWNSPOUT
STRAP
½
8"
6'' M
IN
12'-0 " M
AX.
LENG
TH E
ACH P
IE
CE
O F E
DG
E M
ETAL.
NOTE:
CONTINUOUS CLEAT ON FACE
SIDE NOT SHOWN FOR CLARITY.
MIN. 1/2'' GAP
HOT-DIPPED GALV.
FASTENERS 3'' O.C.
STAGGERED
24 Ga. PREFINISHED
METAL JOINT COVER
PLATE SET IN
SEALANT ON EACH
SIDE AND FASTENED
24 Ga. PREFINISHED
METAL FLASHING
WITH DRIP EDGE
SET FRONT OF
GUTTER 1"
LOWER THAN
BACK (MINIMUM)
ENDS
ALTERNATE
CAP DETAIL
SECTION A-A
D
GUTTER
C
E
B
RIVET AND
SOLDER
GRAVEL STOP
CLEAT
COVER PLATE
GRAVEL STOP
A
A
SLOPE
CAP
CONTINUOS
CLEAT
BUTT TYPE GUTTER EXPANSION JOINT
WATER
DAM
COVER PLATE
1'-2 3/8"
3"
1'-0
3"
/8
/8
1'-7 1/4"
/4
4"
4"
9"
½
NOTE: DIMENSION'S MAY
VARY WITH
MANUFACTURER
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2023c
Texas of Transportation Department
R
/5
/2
:3 :2
P
M A u to d e s k D o c s /0
W
F S
X
X X
X -X
X -X
X N
O C
O N
A M
N T
R O
O F
R E
P L C
/N o c o n a R o o f R e p la c e m e n t .r v t
A2.04
P R
O J E
C T
N O
-1
-2
-0
DRAWN BY: JR
ISSUED: 12/06/2023
N O
C O
N A
M N
T F
A C
- M N
T B
U
IL
D
IN
G P
A R
T
IA
L R
O O
F R
E P
L A
C E
M E
N T
M O N
TA
G U E
S T
(S
.H
N O
C O
N A
T
X
M O N
TA
G U E
C O
U N
T Y
W
IC
H
IT
A F
A L L S
D
IS
T R
IC
T
ROOFING DETAILS (CONT.)
CHECKED BY: AT
3" = 1'-0"
DOWNSPOUT BOTTOM DET.
3" = 1'-0"
METAL EDGE @ EXPANSION JOINT DET.
3" = 1'-0"
GUTTER @ EXPANSION JOINT DET.
3" = 1'-0"
CONCRETE SPLASHBLOCK DETAIL
| Sheets |
| A1.01 - SITE PLAN |
| A2.02 - PROPOSED ROOF PLAN |
| A2.03 - ROOFING DETAILS |
| A2.04 - ROOFING DETAILS (CONT.) |
| DA2.01 - EXISTING ROOF AND DEMOLITION PLAN |
| G0.00 - COVER SHEET |