ESBD_578274_1795118147548_RFB 2026-071 Pricing Form.xlsx
XLSX spreadsheet 16 KB Posted
- Solicitation number
- RFB2026-071
- Issued by
- Loving County, Texas
About this file
This is a pricing form for Request for Bid (RFB) 2026-071 issued by an unspecified state or local government entity. The document serves as a standardized template for vendors to submit pricing quotations for goods or services, though the specific products, services, quantities, and project details are not detailed in the pricing form itself. The form establishes the framework for bidders to present their cost proposals in response to this competitive solicitation, with pricing submissions required by the stated deadline to be considered for award.
The pricing form does not contain information regarding set-asides, incumbent contractors, contract term length, renewal options, funding sources, or specific performance requirements. As a pricing form rather than a comprehensive solicitation document, it functions primarily as a submission template and does not include the detailed scope of work, item specifications, delivery schedules, site visit information, or bidders' conference details that would typically appear in the full RFB package. Prospective bidders would need to reference the complete RFB documentation to understand the full requirements, evaluation criteria, and award timeline for this procurement opportunity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Texas Central Pkwy Drainage
| RFB 2026-071 Pricing Form |
| Texas Central Parkway Drainage Improvements |
| Specification / Detail | Bid Item Description | Total Quantity | Measure | Unit Price | Total Cost | ||
| GENERAL CONDITIONS | |||||||
| 1.1 | 6.4 | MOBILIZATION (MAXIMUM 10%) | 1 | LS | |||
| 1.2 | GP 2.5 | BONDS AND INSURANCE (MAXIMUM 2.5%) | 1 | LS | |||
| 2 | G-4 / G-5 | BETTER STREETS WACO PROJECT DESIGNATION SIGN, INSTALLATION AND REMOVAL | 1 | EA | |||
| 3 | GP.3.6.B | TRENCH SAFETY PLAN | 1 | LS | |||
| DRAINAGE, STREET, AND PAVEMENT MARKINGS | |||||||
| 4 | Detail C803 | CONCRETE LINED CHANNEL | 5,175 | SF | |||
| 5 | SPP 12.7 | EXCAVATABLE FLOW-FILL EXISTING CGMP PIPE STRUCTURES | 100 | CY | |||
| 6 | TxDOT 462 | CONC BOX CULV (6 FT X 4 FT) | |||||
| (INCLUDES EXCAVATABLE FLOWABLE FILL) | 252 | LF | |||||
| 7 | TxDOT 466 | WINGWALL (PW - 1) (HW=8 FT) | 1 | EA | |||
| 8 | TxDOT 466 | WINGWALL (SW - 0) (HW=7 FT) | 1 | EA | |||
| 9 | Detail C803 | SAFETY END TREATMENT | 1 | EA | |||
| 10 | 4.10 / TxDOT 464 | RC PIPE (CL III)(21 IN)(ALL DEPTHS) | 240 | LF | |||
| 11 | Detail C805 | FLUME | 2 | EA | |||
| 12 | Detail C806 | DROP INLET | 1 | EA | |||
| 13 | TxDOT 421 | CONCRETE RIPRAP | 1,340 | SF | |||
| 14 | GP - 3.6.B | TRENCH SAFETY SYSTEM IMPLEMENTATION (DRAINAGE) | 252 | LF | |||
| 15 | 1.1 | PREPARING RIGHT OF WAY (MARS CULVERT & N FLAT CREEK LOCATIONS) | 1 | LS | |||
| 16 | TxDOT 105 | REMOVING STAB BASE & ASPH PAV (11") | 860 | SY | |||
| 17 | TxDOT 110 | EXCAV (ROADWAY & CHANNEL) | 1,070 | CY | |||
| 18 | TxDOT 132 | EMBANK (FNL)(OC)(TY A) | 1,050 | CY | |||
| 19 | TxAPA 341M | 5-INCH HMA (TYPE B) BASE COURSE (64-22) | 1,720 | SY | |||
| 20 | TxAPA 341M | 2-INCH HMA (TYPE C) SURFACE COURSE (64-22) | 860 | SY | |||
| 21 | Detail C805 / | ||||||
| TxDOT 421 | STANDARD CURB AND GUTTER PLACEMENT AND REPLACEMENT | 105 | LF | ||||
| 22 | 5.4/ST-24A & 24B / | ||||||
| TxDOT 421 | STANDARD COMMERCIAL DRIVE APPROACH AND APRON | 2,520 | SF | ||||
| 23 | SPP 12.4 | 3"-6" CLEAN CRUSHED STONE FOR AREAS SUBJECT TO PUMPING OF THE SUBGRADE - 8-INCH THICKNESS | 68 | CY | |||
| 24 | TxDOT 666 / SPP 8.7-001 | REFL PAV MRK TY 1 AND RAIS PAV MRKRS | 1 | LS | |||
| TRAFFIC CONTROL AND EROSION CONTROL | |||||||
| 25 | T-1 / Section 3.3.6.A | TRAFFIC CONTROL IMPLEMENTATION PART A | 1 | LS | |||
| 26 | T-1 / Section 3.3.6.A | TRAFFIC CONTROL IMPLEMENTATION PART B | 1 | LS | |||
| 27 | SPP Section 5 | PORTABLE CHANGEABLE MESSAGE SIGN | 2 | EA | |||
| 28 | 1.10 / WP-1/GP3.6.D | STORM WATER POLLUTION PREVENTION PLAN (1-5 ACRES)(MARS CULVERT & N FLAT CREEK LOCATIONS) | 1 | LS | |||
| 29 | 1.10 / WP-1/GP3.6.D | STORM WATER POLLUTION PREVENTION IMPLEMENTATION (1-5 ACRES)(MARS CULVERT & N FLAT CREEK LOCATIONS) | 1 | LS | |||
| 30 | 1.6 / SPP 12.8.2 | 3" TOPSOIL (IMPORTED) | 4,470 | SY | |||
| 31 | 1.7 / SPP 12.8.3 | BERMUDA SOLID SODDING (PLAN QUANTITY) | 4,470 | SY | |||
| NORTH FLAT CREEK CHANNEL IMPROVEMENTS | |||||||
| 32 | TxDOT 110 | EXCAV (CHANNEL AND REMOVAL OF ALL TREES WITHIN MAIN CHANNEL) | 850 | CY | |||
| TOTAL |
Company Name:
Signature:
&"Arial,Regular"&9T.B.P.E. Registration No. 1046 &"Arial,Regular"&9Page &P of &N
File details come from the government source that posted it. Updated .