ESBD_575578_1794346592129_Attachment B - Construction Drawings.pdf
PDF 2 MB Posted
- Attached to
- Football Stadium Repairs
- Solicitation number
- 734-11092026-KM
- Issued by
- Johnson County, Beaumont City, Texas
About this file
These construction drawings document structural repairs for the Lamar University Football Stadium (Umphrey Stadium) located at 4400 S. Martin Luther King Jr. Parkway in Beaumont, Texas. The project, issued for construction on November 6, 2026, involves comprehensive structural repairs to the West and East stadium stands, including concrete beam and wall repairs, soffit repairs, expansion joint replacements, joint sealant work, corroded steel connection replacement, and handrail cleaning and coating. The architectural and structural design team includes Stantec Architecture Inc. as the architect and Walter P. Moore and Associates Inc. (Martinez Moore Engineers LLC) as the structural engineer. The scope of work encompasses selective demolition of existing stadium seating, structural concrete repairs with shoring, reinforcement augmentation where required, and architectural restoration including painting of repaired concrete surfaces and guard walls with specified finishes such as Natural Linen (SW 9109) and Positive Red (SW 6871) for accent areas.
The project includes a base bid scope and multiple add alternates for expanded painting and coating work. Key technical requirements include installation of temporary shoring prior to concrete repairs, non-destructive evaluation to locate embedded items before cutting or drilling, compliance with the International Existing Building Code 2021 as amended by the City of Beaumont, and adherence to ICRI standards for concrete repair. Concrete repair work must achieve specified cover requirements with reinforcement augmentation tables provided for varying bar loss scenarios. The contractor is responsible for structural stability during construction, disposal of removed materials in compliance with federal and state environmental guidelines, and coordination with the owner regarding salvage and retention of stadium seating components. All work must maintain fire ratings of existing construction, coordinate with owner operations to minimize disruption, and include photo documentation of existing conditions prior to demolition and repair activities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER
LAMAR UNIVERSITY
4400 S MARTIN LUTHER KING JR PKWY
BEAUMONT, TX, 77705
TEL. (409) 880-7011
PROJECT TEAM:
ARCHITECT
STANTEC ARCHITECTURE INC.
1100 LOUISIANA, SUITE ONE,
HOUSTON, TX, 77002
TEL. (713) 548-5700
STRUCTURAL ENGINEER
MARTINEZ MOORE ENGINEERS, LLC
1301 MCKINNEY, SUITE 1100,
HOUSTON, TX 77010
TEL. (832) 779-6142
TRUE
NORTH
TRUE
NORTH
Stantec Project Number:
The professional's seal on the cover sheet represents that the information on the cover sheet is accurate in designer's professional opinion but does not assume professional responsibility for documents sealed by others that are referenced on the cover sheet. All professionals sealing drawings as a part of the design are professionally responsible for their own sealed documents.
LOCATION MAP
VICINITY MAP
Issued/Revision By Appd YYYY.MM.DD
4400 S Martin Luther King Jr Pkwy, Beaumont, TX 77705
ISSUE FOR CONSTRUCTION
NOVEMBER 06, 2026
Lamar University, Football
Stadium Repairs
234601127
STADIUM
1 Issue for Construction Stantec Lamar 2026.11.06
11/06/2026
SYMBOLS
DETAIL NUMBER
SHEET ON WHICH
DETAIL IS SHOWN
DETAIL CALLOUTS
EXTERIOR ELEVATIONS
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS SHOWN
INTERIOR ELEVATIONS
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS SHOWN
BUILDING SECTIONS
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
WALL SECTIONS
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
FLOOR OR ROOF LEVEL NAME
NORTH ARROW
DRAWING REVISION
PROJECT
NORTH
MATCH LINE
A802
A1
A101
1 Ref
1 Ref
R ef
SIM
A909
SIM
A909
A101
1 DEMOLITION SHEET NOTE
GENERAL SHEET NOTE
BREAK LINE
R ef
ALIGN
ROOM NAME
ROOM NAME
AREA NAME
150 SF
AREA TAG
ROOM NUMBER
AREA
1t WINDOW TAG
PARTITION TYPE TAG
DOOR OPENING NUMBER100A10
T/O FLOOR
SPOT ELEVATION
COLUMN GRID NOTATION
EXISTING NEW
CENTERLINE
TRUE
NORTH
N.I.C. OR EXISTING SHADING
INDICATES CHANGE IN ELEVATION
(IN PLAN OR ELEVATION)
Name
Elevation0.00
FLOOR
VERTICAL ELEVATION
2"
DO NOT SCALE DRAWINGS.
USE FIGURED DIMENSIONS ONLY
INFORMATION
TEXT
TEXT LEADER
SD3W
A a
ABBREVIATIONS
# POUND
+/- PLUS OR MINUS (TOLERANCE)
Ø DIAMETER
AFF ABOVE FINISH FLOOR
AVB AIR / VAPOR BARRIER
BC BOTTOM OF CURB
BF BARRIER FREE
B/O BOTTOM OF
BW BOTTOM OF WALL
CF/CI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CFMF COLD FORMED METAL FRAMING
CF/OI CONTRACTOR FURNISHED, OWNER INSTALLED
CJ CONSTRUCTION JOINT / CONTROL JOINT
C/L CENTER LINE
COL COLUMN
CONC CONCRETE
DIA DIAMETER
DIM DIMENSION
DS DOWNSPOUT
DWG DRAWING
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
EQ EQUAL
ETR EXISTING TO REMAIN
EXT EXTERIOR
F/F FACE TO FACE
FFE FINISHED FLOOR ELEVATION
FLR FLOOR
FTG FOOTING
GA GAUGE
HO HOLD OPEN
HP HIGH POINT
HR HOUR
ID INSIDE DIAMETER
INT INTERIOR
JT JOINT
LP LOW POINT
MAX MAXIMUM
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
M/O MASONRY OPENING
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O/C ON CENTER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED, CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED, OWNER INSTALLED
OPP OPPOSITE
R RISERS (STAIRS)
REQ REQUIRED
R/O ROUGH OPENING
SIM SIMILAR
STC SOUND TRANSMISSION CLASS
T TREADS (STAIRS)
TC TOP OF CURB
T/O TOP OF
TBD TO BE DETERMINED
UON UNLESS OTHERWISE NOTED
U/S UNDERSIDE
VIF VERIFY IN FIELD, BY CONTRACTOR
W/ WITH
W/O WITHOUT
WP WORKING POINT
GENERAL NOTES
GENERAL RENOVATION NOTES
1. FIELD VERIFY ALL DIMENSIONS CONCERNING EXISTING AND NEW WORK AND NOTIFY THE ARCHITECT OF
CONDITIONS REQUIRING CHANGES BEFORE PROCEEDING WITH FABRICATION OR INSTALLATION OF
WORK. WHERE CHANGES ARE NECESSARY, THE DRAWINGS SHOW DESIGN INTENT. CONFIRM
CONDITIONS ON DRAWINGS EXPEDITIOUSLY TO MAINTAIN PROJECT SCHEDULE AND PRIOR TO
PROCEEDING WITH THE WORK IN QUESTION AND WITH RELATED WORK.
2. AREAS SHOWN FOR DEMOLITION ARE APPROXIMATE, ACCURATE EDGES TO BE SET BY THE GENERAL
CONTRACTOR IN THE FIELD.
3. REVIEW AND COORDINATE NEW WORK WITH ALL EXISTING CONDITIONS AND ADJACENT WORK. CHANGE
ORDER REQUESTS WILL NOT BE APPROVED FOR CONDITIONS OR CONFLICTS THAT COULD HAVE
REASONABLY BEEN DETERMINED BY THE BIDDER DURING BID, FIELD INSPECTION, OR FOR ANY
CONDITIONS AND/OR CONFLICTS THAT COULD HAVE BEEN COORDINATED BY THE CONTRACTOR AND
SUBCONTRACTORS AFTER AWARD OF CONTRACT. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
ARCHITECT OF DISCREPANCIES AND SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT REGARDING
DESIGN INTENT PRIOR TO PROVIDING BID.
4. PERFORM DISASSEMBLY AND REMOVALS IN A CONTROLLED MANNER; WITHOUT UNNECESSARY CUTS;
WITHOUT DAMAGE TO THE SITE, STRUCTURE OR FEATURES; WITHOUT DAMAGE TO THE MATERIALS OR
CONSTRUCTION TO REMAIN.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSAL OF ALL REMOVED ITEMS IN A SAFE AND
ENVIRONMENTALLY ACCEPTABLE MANNER COMPLYING WITH FEDERAL, STATE, AND LOCAL GUIDELINES
FOR DISPOSING OF MATERIALS.
6. WHERE NEW WORK ADJOINS EXISTING, SUCH NEW WORK SHALL BE PROPERLY INTEGRATED WITH THE
EXISTING TO ENSURE UNIFORM APPEARANCE AND FUNCTION, UNLESS OTHERWISE NOTED.
7. MAINTAIN FIRE RATINGS OF ADJACENT EXISTING CONSTRUCTION AND SUPPLEMENT WITH TEMPORARY
CONSTRUCTION PARTITIONS MATCHING REQUIRED EXISTING RATINGS.
8. MAINTAIN ACCESS TO PROJECT AREA AND INSTALL TEMPORARY LIFE SAFETY MEASURES AS REQUIRED
BY OWNER AND AHJ.
9. FLOOR ELEVATIONS NOTED ARE TO THE TOP OF CONCRETE SLAB OR DECK UNLESS OTHERWISE NOTED.
10. WHERE EXISTING FINISHES ARE REQUIRED TO BE REMOVED TO INSTALL NEW FINISHES, REMOVE DOWN
TO EXISTING SUBSTRATE AND PREPARE SUBSTRATE TO CREATE A SMOOTH AND LEVEL CONDITION.
PROVIDE CONTRACT FINISHES AS INDICATED ON CONTRACT DOCUMENTS.
11. PATCH HOLES IN EXISTING WALLS, COLUMNS, FLOORS, AND CEILINGS TO REMAIN. MATCH ADJACENT
EXISTING SURFACES AND MATERIALS OR AS REQUIRED TO RECEIVE SCHEDULED NEW FINISHES.
12. PROVIDE TEMPORARY [DUST] BARRIERS AND/OR INFECTION CONTROL PARTITIONS NECESSARY TO
MAINTAIN EXISTING FACILITY OPERATIONS. CONSTRUCTION AND LOCATION OF TEMPORARY BARRIERS
ARE TO BE COORDINATED WITH OWNER PRIOR TO INSTALLATION.
13. UNLESS OTHERWISE NOTED, REMOVE EXISTING UNUSED PROJECTIONS, HANGER, BOLTS, NAILS, BRACKETS, CURTAIN RODS, VALANCES, ETC. FROM EXISTING WALLS AND COLUMNS. PATCH HOLES IN
EXISTING WALLS, COLUMNS, FLOORS, AND CEILINGS TO REMAIN. MATCH ADJACENT EXISTING SURFACES
AND MATERIALS OR AS REQUIRED TO RECEIVE SCHEDULED NEW FINISHES.
14. ALL EXISTING AND NEW PENETRATIONS THROUGH FLOORS, FIRE-RATED OR SMOKE-RATED WALLS, BARRIERS OR PARTITIONS, WITHIN THE AREA OF WORK SHALL BE FILLED AND SEALED WITH APPROVED
FIRE/SMOKE RATED PENETRATION SEALANT SYSTEMS TO MAINTAIN FIRE RATING CONTINUITY OF THE
PENETRATED CONSTRUCTION.
15. WHERE CUTTING AND/OR CHIPPING OF STRUCTURAL SLAB IS REQUIRED, NO REBAR SHALL BE CUT
WITHOUT WRITTEN APPROVAL FROM THE BUILDING OWNER AND THE DESIGNATED STRUCTURAL
ENGINEER. WHERE CORE DRILLING IS REQUIRED, VERIFY EXACT LOCATIONS WITH THE DESIGNATED
STRUCTURAL ENGINEER AND ARCHITECT BEFORE PROCEEDING. ADHERE TO BUILDING REGULATIONS
AND GUIDELINES PRIOR TO CORE DRILLING.
16. PROVIDE ADEQUATE TEMPORARY SUPPORT DURING CUTTING AND PATCHING SO AS TO PREVENT
DAMAGE TO RETAINED OR ADJOINING WORK.
17. CUT THE WORK USING METHODS THAT ARE LEAST LIKELY TO DAMAGE WORK TO BE RETAINED OR
ADJOINING WORK. PATCH WITH DURABLE SEAMS THAT ARE AS INCONSPICUOUS AS POSSIBLE AND THAT
COMPLY WITH SPECIFIED TOLERANCES FOR THE WORK. WHERE NECESSARY, EXTEND FINISH
RESTORATION INTO RETAINED ADJOINING WORK IN A MANNER WHICH WILL ELIMINATE EVIDENCE OF
PATCHING AND REFINISHING.
18. DO NOT DISPOSE OF REMOVED STADIUM SEATING OR ASSOCIATED COMPONENTS UNTIL REVIEWED AND
APPROVED BY OWNER. CONTRACTOR SHALL COORDINATE WITH OWNER TO IDENTIFY ITEMS TO BE
SALVAGED, RETAINED, OR DISPOSED OF. UPON OWNER APPROVAL, LEGALLY DISPOSE OF ITEMS NOT
DESIGNATED FOR SALVAGE.
19. AT ALL EXISTING CONCRETE STRUCTURAL REPAIR LOCATIONS, PATCH AND PREPARE REPAIRED AREAS
FOR PAINTING. PAINT REPAIRED AND PATCHED AREAS TO MATCH EXISTING ADJACENT COLOR, SHEEN, TEXTURE, AND FINISH. CONTRACTOR SHALL VERIFY EXISTING PAINT MATCH AND OBTAIN OWNER
APPROVAL PRIOR TO APPLICATION.
20. THE CONTRACTOR SHALL PROMPTLY DOCUMENT AND NOTIFY THE ARCHITECT OF CONCEALED OR
MATERIALLY DIFFERING CONDITIONS BEFORE DISTURBING THE AFFECTED WORK. ADJUSTMENTS, IF ANY, WILL BE EVALUATED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
21. ALL WORK SHOWN OR INDICATED IN THE CONTRACT DOCUMENTS SHALL BE INCLUDED IN THE BASE BID
UNLESS SPECIFICALLY IDENTIFIED AS AN ADD ALTERNATE. ADD ALTERNATE WORK SHALL BE PRICED
SEPARATELY AS INDICATED.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issue/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Notes
/6 /2
:1
:4
P M
12" = 1'-0"
1< P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
4400 S Martin Luther King Jr Pkwy, Beaumont, TX 77705
DRAWING LIST, STANDARD
ABBREVIATIONS, AND SYMBOLS
Lamar University
Lamar University, Football Stadium Repairs
234601127
G-001
STANTEC ARCHITECTURE INC.
1100 LOUISIANA
SUITE ONE
HOUSTON, TX 77002
Tel: (713) 548-5700 • www.stantec.com
1 Issue for Construction Stantec Lamar 2026.11.06
NO. DRAWING NAME
GENERAL
G-000 COVER SHEET
G-001 DRAWING LIST, STANDARD ABBREVIATIONS, AND SYMBOLS
STRUCTURAL
S-000 GENERAL NOTES
S-100 WEST STANDS FRAMING PLAN - SOFFIT REPAIRS
S-101 EAST STANDS FRAMING PLAN - SOFFIT REPAIRS
S-102 WEST STANDS FRAMING PLAN - TOP
S-103 EAST STANDS FRAMING PLAN - TOP
S-104 PRESS BOX LOWER LEVEL ROOF FRAMING PLAN
S-300 TYPICAL DETAILS
S-301 TYPICAL DETAILS
ARCHITECTURAL SITE
AS-100 SITE PLAN - OVERALL
ARCHITECTURE
A-100 WEST STANDS SOFFITT
A-101 EAST STANDS SOFFITT
A-102 WEST STANDS - FLOOR PLAN
A-103 EAST STANDS - FLOOR PLAN
A-104 CONCOURSE PLAN
DRAWING LIST
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:4
P M
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
COVER SHEET
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
CVR
LAMAR UNIVERSITY - PROVOST UMPHREY STADIUM STRUCTURAL REPAIRS
SHEET LIST
SHEET
NUMBER SHEET NAME
CVR COVER SHEET
S-000 GENERAL NOTES
S-100 WEST STANDS FRAMING PLAN - SOFFIT REPAIRS
S-101 EAST STANDS FRAMING PLAN - SOFFIT REPAIRS
S-102 WEST STANDS FRAMING PLAN - TOP
S-103 EAST STANDS FRAMING PLAN - TOP
S-104 PRESS BOX LOWER LEVEL ROOF FRAMING PLAN
S-300 TYPICAL DETAILS
S-301 TYPICAL DETAILS
PROJECT LOCATION
N
SITE PLAN
4400 S MARTIN LUTHER KING JR PKWY, BEAUMONT, TX 77705
ISSUE FOR CONSTRUCTION RA 2026.11.06
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:4
P M
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
GENERAL NOTES
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
S-000
PART I - DESIGN CRITERIA
A. GENERAL BUILDING CODE
1. THE CONSTRUCTION DOCUMENTS ARE BASED ON THE REQUIREMENTS OF THE
INTERNATIONAL EXISTING BUILDING CODE 2021 AS AMEDED BY THE CITY OF BEUMONT,
TEXAS. DOCUMENTS ARE BASED UPON REPAIRS OF THE EXISTING STRUCTURE.
B. DEAD LOADS
1. SELF WEIGHT OF THE STRUCTURE.
C. LIVE LOADS
1. 60 PSF - STADIUMS AND ARENAS WITH FIXED SEATS (FASTENED TO THE FLOOR)
D. WIND LOADS
1. DRAWIINGS HEREIN ARE FOR THE REPAIRS OF AN EXISTING STRUCTURE. NO CHANGES TO
THE LATERAL SYSTEM ARE REQUIRED IN ACCORDANCE WITH IEBC 2021
PART II - SHORING
A. GENERAL
1. SHORING DESIGN IN THESE DRAWINGS IS AN INTERIM, TEMPORARY MEASURE
TO PROVIDE SUPPLEMENTAL GRAVITY SUPPORT TO THE AREA AFFECTED BY THE
DAMAGED MEMBERS.
2. THESE DRAWINGS INDICATE SHORING PERFORMANCE REQUIREMENTS FOR
STRUCTURAL REPAIRS AT LAMAR STADIUM AND LOCATION OF SHORING WITHIN
FACILITY. THE DETAILS SHOWN IN THE DRAWINGS ARE CONCEPTUAL IN NATURE TO
INDICATE THE INTENDED MEANS OF SUPPORTING THE INDICATED MEMBERS BY THE
SHORES. THE FINAL DESIGN OF THE SHORING TO MEET THESE REQUIREMENTS SHALL
BE RESPONSIBILITY OF THE SHORING CONTRACTOR AND SHALL BE PERFORMED BY A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS
LOCATED.
3. THE SHORING CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND DESIGN
CALCULATIONS OF THE SHORING TO THE ENGINEER FOR REVIEW AND APPROVAL
BEFORE EXECUTING THE INSTALLATION. THE SHOP DRAWINGS AND CALCULATIONS
SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE
STATE WHERE THE PROJECT IS LOCATED. SHOP DRAWINGS SHALL INCLUDE THE
FOLLOWING ELEMENTS:
a. SHORING POSTS.
b. DETAILS OF ATTACHMENT OF SHORING POSTS TO SUPPORTING
STRUCTURAL MEMBERS.
c. DETAILS OF SHORING POST BASE PLATES.
B. DESIGN CRITERIA
1. SHORING SHALL BE DESIGN FOR A TOTAL SERVICE (UNFACTORED) DEAD LOAD
OF 12 PSF AND SERVICE (UNFACTORED) LIVE LOAD OF 20 PSF WHERE SHORING DETAILING
IS NOT PROVIDED. PROVIDE A MINIMUM SAFETY FACTOR OF 2.0 FOR SHORING DESIGN.
REFER TO DRAWINGS FOR REQUIRED RATED CAPACITIES OF INDIVIDUAL SHORING
ELEMENTS.
2. CONSTRUCTION LOADS (EQUIPMENT, MATERIALS, AND WORKERS) ON THE WORK
AREA SHALL NOT EXCEED 12 PSF.
3. THE AREA BEING SHORED SHALL NOT BE OPEN TO THE PUBLIC DURING
CONSTRUCTION ACTIVITIES.
4. THE REQUIRED RATED CAPACITY OF THE SHORING INDICATED IN THE DRAWINGS SHALL
CONSIDER THE HEIGHT OF THE SHORING UNDER THE MEMBERS BEING SHORED WHEN THE
SHORES ARE EXTENDED IN PLACE.
C. INSTALLATION OF SHORING
1. SHORING SHALL BE PUT IN PLACE PRIOR TO PERFORMING THE REPAIRS
INDICATED IN THE DRAWINGS. SHORING SHALL REMAIN IN PLACE DURING REPAIRS
AND SHALL NOT BE REMOVED UNTIL ALL REPAIRS HAVE BEEN COMPLETED.
2. SHORES SHALL BE INSTALLED SNUG TIGHT ONLY AGAINST THE MEMBER BEING
SHORED. DO NOT RELIEVE LOAD FROM THE EXISTING STRUCTURE.
3. ALL SHORING MUST BE INSTALLED VERTICALLY PLUMB. PROVIDE BRACING
BETWEEN ADJACENT SHORE POSTS/LEGS AS REQUIRED FOR STABILITY. INSTALL
SHORING BRACING PER MANUFACTURER’S SPECIFICATIONS.
4. SHORING SHALL BE LOCATED UNDER THE MEMBERS SHOWN IN THE DRAWINGS
AND POSITIONED SO THAT THE LOAD IS TRANSFERRED DIRECTLY TO THE
SUPPORTING STRUCTURAL MEMBERS INDICATED IN THE DRAWINGS. CONTACT
ENGINEER IF A SHORING CANNOT BE PROVIDED AT A LOCATION INDICATED IN THE
DRAWINGS. IF SUPPORTING MEMBERS ARE PART OF THE FOUNDATION, CONTRACTOR
SHALL FIELD VERIFY THE LOCATION OF THE SUPPORTING FOUNDATION ELEMENTS.
5. SHORING POSTS/LEGS SHALL BE PROVIDED WITH BASE PLATES SO THAT THE
LOAD IS UNIFORMLY DISTRIBUTED OVER AN AREA OF 10 SQUARE FOOT SECTION OF
THE FLOOR SLAB.
6. PROVIDE APPROPRIATE ANCHORAGE AT THE TOP AND BOTTOM OF SHORING
ELEMENTS TO PREVENT OVERTURNING OR TIPPING OVER OF SHORING.
7. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PROTECT EXPOSED
STRUCTURAL FINISHED SURFACES (FLOOR, OVERHEAD SLAB, BEAMS, COLUMNS,
WALLS, ETC.) DURING INSTALLATION OF SHORING.
8. SHORING LAYOUT SHALL MEET SAFETY AND OPERATION REQUIREMENTS OF THE
OWNER.
9. SHORING DETAILS SHOWN IN DRAWINGS ARE CONCEPTUAL ONLY. ACTUAL
SHORING MEMBERS AND CONNECTIONS MAY VARY DEPENDING ON THE SHORING
MANUFACTURER’S PROPRIETARY SYSTEM AVAILABLE.
10. SHORING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
MANUFACTURER’S SPECIFICATIONS.
PART III - NON-DESTRUCTIVE EVALUATION
A. ITEMS EMBEDDED IN CONCRETE STRUCTURES
1. ITEMS EMBEDDED IN CONCRETE STRUCTURES SHALL NOT BE DAMAGED DURING
REPAIR WORK OR INSTALLATION OF NEW MEMBERS REQUIRING POST-INSTALLED
ANCHORS. EMBEDDED ITEMS MAY INCLUDE MILD REINFORCEMENT, PRESTRESSING
REINFORCEMENT, DOWELS, EMBEDDED CONNECTIONS, ELECTRICAL CONDUITS,
PLUMBING, ETC.
2. ITEMS EMBEDDED IN CONCRETE SHALL BE LOCATED BY NON-DESTRUCTIVE
EVALUATION PRIOR TO PERFORMING ANY WORK. CONTRACTOR SHALL MARK ON THE
STRUCTURE THE LOCATION OF EMBEDDED ITEMS AND PROVIDE A REPORT TO THE
ENGINEER.
3. ENGINEER MAY REQUIRE A PARTICULAR NON-DESTRUCTIVE EVALUATION
METHOD FOR THE LOCATION OF EMBEDDED ITEMS.
PART IV - SELECTIVE DEMOLITION
A. RESPONSIBILITY OF THE CONTRACTOR FOR STABILITY OF THE STRUCTURE DURING
DECONSTRUCTION / DEMOLITION
1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL REQUIRED
BRACING DURING DEMOLITION TO MAINTAIN THE STABILITY AND SAFETY OF ALL
STRUCTURAL ELEMENTS DURING THE DEMOLITION PROCESS. CONTRACTOR SHALL
ENGAGE A PROFESSIONAL ENGINEER TO SURVEY CONDITION OF BUILDING TO
DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL
DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF STRUCTURE OR ADJACENT
STRUCTURES DURING SELECTIVE DEMOLITION OPERATIONS.
B. DEFINITIONS
1. REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY
DISPOSE OF THEM OFF-SITE, UNLESS INDICATED TO BE REMOVED AND SALVAGED OR
REMOVED AND REINSTALLED.
2. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND
DELIVER THEM TO OWNER READY FOR REUSE. OWNER TO IDENTIFY ITEMS TO BE
REUSED OR SALVAGED.
3. EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO
BE REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, REMOVED
AND SALVAGED, OR REMOVED AND REINSTALLED.
C. MATERIAL OWNERSHIP
1. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, OR
OTHERWISE INDICATED TO REMAIN OWNER’S PROPERTY, DEMOLISHED MATERIALS
SHALL BECOME CONTRACTOR’S PROPERTY AND SHALL BE REMOVED FROM PROJECT
SITE. THE MATERIALS REMOVED SHALL BE DISPOSED OF IN A PROPER AND LEGAL
MANNER PER FEDERAL/STATE OR LOCAL ORDINANCES.
D. QUALITY ASSURANCE
1. DEMOLITION FIRM QUALIFICATIONS: AN EXPERIENCED FIRM THAT HAS
SPECIALIZED IN DEMOLITION WORK SIMILAR IN MATERIAL AND EXTENT TO THAT
INDICATED FOR THIS PROJECT.
2. PROFESSIONAL QUALIFICATIONS OF ENGINEER ENGAGED BY CONTRACTOR:
CURRENT REGISTRATION IN THE STATE WHERE THE PROJECT IS LOCATED.
PART IV - SELECTIVE DEMOLITION (CONTINUED)
4. PHOTO DOCUMENTATION OF EXISTING CONDITIONS OF THE BUILDING AND
ADJOINING PROPERTIES SHALL BE PERFORMED BY CONTRACTOR PRIOR TO
DEMOLITION. PHOTOS SHALL BE SUBMITTED TO OWNER AND ENGINEER OF RECORD.
5. PRE-DEMOLITION CONFERENCE: CONDUCT CONFERENCE AT PROJECT SITE TO
ADDRESS THE FOLLOWING:
a. INSPECT AND DISCUSS CONDITION OF CONSTRUCTION TO BE
SELECTIVELY DEMOLISHED.
b. REVIEW STRUCTURAL LOAD LIMITATIONS OF EXISTING STRUCTURE AS
APPROPRIATE FOR THE PROPOSED MEANS AND METHODS.
c. REVIEW AND FINALIZE SELECTIVE DEMOLITION SCHEDULE AND VERIFY
AVAILABILITY OF MATERIALS, DEMOLITION PERSONNEL, EQUIPMENT, AND
FACILITIES NEEDED TO MAKE PROGRESS AND AVOID DELAYS.
E. PROJECT CONDITIONS
1. CONDUCT SELECTIVE DEMOLITION SO OWNER’S OPERATIONS WILL NOT BE
DISRUPTED. PROVIDE NOT LESS THAN 72-HOUR NOTICE TO OWNER OF ACTIVITIES
THAT WILL AFFECT OWNER’S OPERATIONS.
2. MAINTAIN ACCESS TO EXISTING WALKWAYS, CORRIDORS, AND OTHER
ADJACENT OCCUPIED OR USED FACILITIES. DO NOT CLOSE OR OBSTRUCT WALKWAYS,
CORRIDORS, OR OTHER OCCUPIED OR USED FACILITIES WITHOUT WRITTEN
PERMISSION FROM AUTHORITIES HAVING JURISDICTION.
3. OWNER ASSUMES NO RESPONSIBILITY FOR CONDITION OF AREAS TO BE
SELECTIVELY DEMOLISHED.
a. CONDITIONS EXISTING AT TIME OF INSPECTION FOR BIDDING PURPOSE
WILL BE MAINTAINED BY OWNER AS FAR AS PRACTICAL.
b. BEFORE SELECTIVE DEMOLITION, OWNER WILL REMOVE ITEMS WITHIN
SPACE AS NEEDED.
4. IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE
ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ENGINEER AND OWNER.
THESE MATERIALS SHALL BE REMOVED AS DISPOSED AS APPROVED BY GOVERNING
AGENCY.
5. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE WILL NOT BE
PERMITTED.
6. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN
IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION
OPERATIONS. MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING
SELECTIVE DEMOLITION OPERATIONS.
7. PROTECT ADJACENT PAVING (ASPHALT OR CEMENT ROADWAYS, SEWERS,
ETC.), AND DRAINAGE DITCHES AS NEEDED.
8. ALL AREAS OUTSIDE OF DEMOLITION SCOPE ARE TO BE PROTECTED FROM
DAMAGE BY CONTRACTOR. RESTORE AREAS SUBJECT TO INCIDENTAL DAMAGE TO
THEIR PRE-DEMOLITION CONDITION.
F. UTILITY SERVICES
1. REFER TO DIVISION 01 SECTIONS REGARDING REQUIREMENTS FOR
MAINTAINING EXISTING UTILITIES IN SERVICE AND FOR INTERRUPTIONS OF
EXISTING UTILITIES.
G. PREPARATION
1. DANGEROUS MATERIALS: DRAIN, PURGE, OR OTHERWISE REMOVE, COLLECT,
AND DISPOSE OF CHEMICALS, GASES, EXPLOSIVES, ACIDS, FLAMMABLES, OR OTHER
DANGEROUS MATERIALS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION
OPERATIONS.
a. PROTECT EXISTING SITE IMPROVEMENTS, APPURTENANCES, AND
LANDSCAPING TO REMAIN.
b. ERECT A PLAINLY VISIBLE FENCE AROUND DRIP LINE OF INDIVIDUAL
TREES OR AROUND PERIMETER DRIP LINE OF GROUPS OF TREES TO REMAIN.
2. CONTRACTOR TO MAINTAIN ACCESS TO EXITS AND EXIT STAIRS AT ALL
TIMES. FIRE ALARMS AND SMOKE DETECTION SYSTEM SHALL REMAIN OPERATIONAL
AT ALL TIMES. PROTECT SMOKE DETECTORS AS REQUIRED AND IN CONFORMANCE TO
LOCAL CODES AND LOCAL AUTHORITIES
3. TEMPORARY FACILITIES: PROVIDE TEMPORARY BARRICADES AND OTHER
PROTECTION REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO ADJACENT
BUILDINGS AND FACILITIES TO REMAIN.
a. PROVIDE PROTECTION TO ENSURE SAFE PASSAGE OF PEOPLE AROUND
SELECTIVE DEMOLITION AREA AND TO AND FROM OCCUPIED PORTIONS OF
ADJACENT FACILITIES.
4. CONTRACTOR TO PROVIDE ALL NECESSARY TRAFFIC CONTROL AND PEDESTRIAN
CONTROL MEASURES AS REQUIRED.
5. CONTRACTOR TO COORDINATE WITH OWNER IF ANY REMOVAL OF LANDSCAPE IS
REQUIRED
6. TEMPORARY PARTITIONS: ERECT AND MAINTAIN DUSTPROOF PARTITIONS AND
TEMPORARY ENCLOSURES TO LIMIT DUST AND DIRT MIGRATION AND TO SEPARATE
AREAS FROM FUMES AND NOISE.
7. TEMPORARY SHORING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR
SHORING, BRACING, OR STRUCTURAL SUPPORT TO PRESERVE STABILITY AND TO
PREVENT UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF CONSTRUCTION
BEING DEMOLISHED. STRENGTHEN OR ADD TEMPORARY SUPPORTS WHEN REQUIRED
DURING PROGRESS OF SELECTIVE DEMOLITION.
H. POLLUTION CONTROLS
1. REFER TO DIVISION 01 SPECIFICATION SECTIONS FOR REQUIREMENTS ON
DUST CONTROL, DISPOSAL, AND CLEANING OF DEMOLISHED MATERIAL.
I. EXECUTION OF SELECTIVE DEMOLITION
1. GENERAL: DEMOLISH EXISTING CONSTRUCTION AS INDICATED. USE METHODS
REQUIRED TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING
REGULATIONS AND AS FOLLOWS:
a. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO
REMAIN OR ADJOINING CONSTRUCTION.
b. DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF
FLAMMABLE MATERIALS. AT CONCEALED SPACES VERIFY CONDITION AND
CONTENTS OF HIDDEN SPACE BEFORE STARTING FLAME-CUTTING OPERATIONS.
MAINTAIN FIRE WATCH AND PORTABLE FIRE-SUPPRESSION DEVICES DURING
FLAME-CUTTING OPERATIONS.
c. MAINTAIN ADEQUATE VENTILATION WHEN USING CUTTING TORCHES.
d. REMOVE DECAYED, VERMIN-INFESTED, OR OTHERWISE DANGEROUS OR
UNSUITABLE MATERIALS AND PROMPTLY DISPOSE OF OFF-SITE.
e. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND
MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING WALLS,
SLABS, OR FRAMING.
f. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY.
2. EXISTING FACILITIES: COMPLY WITH OWNER’S REQUIREMENTS FOR USING
AND PROTECTING OTHER BUILDING FACILITIES DURING SELECTIVE DEMOLITION
OPERATIONS.
3. REMOVED AND SALVAGED ITEMS: COMPLY WITH THE FOLLOWING:
a. CLEAN SALVAGED ITEMS.
b. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER.
c. TRANSPORT ITEMS TO OWNER’S STORAGE AREA AS DESIGNATED BY
OWNER.
4. EXISTING ITEMS TO REMAIN: CONTRACTOR TO COORDINATE WITH OWNER
(PRIOR TO BEGINNING WORK) ON ITEMS THAT ARE TO REMAIN AND HENCE BE
PROTECTED DURING THE DEMOLITION PROCESS. WHEN PERMITTED BY OWNER, ITEMS
MAY BE REMOVED TO A SUITABLE AND/OR PROTECTED LOCATION.
5. CONCRETE SLABS-ON-GRADE: SAW-CUT PERIMETER OF AREA TO BE
DEMOLISHED, THEN BREAK UP AND REMOVE.
J. DISPOSAL OF DEMOLISHED MATERIALS
1. GENERAL: PROMPTLY DISPOSE OF DEMOLISHED MATERIALS. DO NOT ALLOW
DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE.
2. BURNING: DO NOT BURN DEMOLISHED MATERIALS.
3. DISPOSAL: TRANSPORT DEMOLISHED MATERIALS OFF OWNER’S PROPERTY AND
LEGALLY DISPOSE OF THEM.
PART V - CONCRETE REPAIRS
A. CONCRETE REPAIR MATERIALS
1. ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS AS SPECIFIED IN
SPECIFICATION SECTION “CONCRETE REPAIR MATERIALS.”
B. HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS
1. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN ANY CONCRETE
POURS UNLESS SHOWN ON THE DRAWINGS. THE ENGINEER SHALL APPROVE ALL
DEVIATIONS OR ADDITIONAL JOINTS IN WRITING.
C. REINFORCING STEEL
1. ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 UNLESS NOTED
OTHERWISE ON THE DRAWINGS OR IN THESE NOTES.
D. REINFORCING STEEL COVERAGE
1. REINFORCING STEEL COVERAGE SHOULD CONFORM TO THE REQUIREMENTS
SPECIFIED ON THE DRAWINGS. COVER SPECIFIED SHALL BE CONSIDERED MINIMUM,
HOWEVER EXISTING REINFORCEMENT MAY HAVE A SMALLER COVER THAN SPECIFIED
IN DRAWING DETAILS. CONCRETE PATCHES CAN BE BUILT UP TO PROVIDE THE
REQUIRED COVER AS LONG AS THE PATCH APPEARANCE IS ACCEPTABLE TO OWNER
AND IT DOES NOT REPRESENT A TRIPPING HAZARD TO PEDESTRIANS OR A BUMP TO
VEHICLES. COVER IN STRUCTURAL MEMBERS NOT SPECIFIED IN THE DETAILS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318 UNLESS SPECIFIED OTHERWISE ON THE
DRAWINGS.
PART VI - STRUCTURAL STEEL
A. ALL STRUCTURAL STEEL SHALL CONFORM TO THE REQUIREMENTS AS SPECIFIED IN
SPECIFICATION SECTION “STEEL FIELD RE-COATING”.
PART VII - SPECIAL INSPECTIONS
A. STATEMENT OF SPECIAL INSPECTIONS
1. SPECIAL INSPECTION IS REQUIRED FOR THE ITEMS LISTED BELOW. REFER
TO GENERAL NOTES PART “STRUCTURAL TESTING AND INSPECTIONS” FOR TYPE AND
EXTENT OF EACH SPECIAL INSPECTION AND TEST. GENERAL NOTES PART
“STRUCTURAL TESTING AND INSPECTIONS” ALSO INDICATES WHETHER CONTINUOUS
OR PERIODIC INSPECTION IS REQUIRED FOR THE ITEMS LISTED ABOVE ADDITIONAL
INFORMATION.
B. THE OWNER’S TESTING AGENCY SHALL PROVIDE SPECIAL INSPECTION SERVICES
IN ACCORDANCE WITH THE REFERENCED BUILDING CODE FOR THE FOLLOWING ITEMS.
1. STEEL CONSTRUCTION:
a. STRUCTURAL STEEL AND BOLTING
b. ALL FIELD WELDING
c. WELDING OF STRUCTURAL STEEL
2. CONCRETE CONSTRUCTION:
a. CONCRETE/GROUTING MATERIALS AND PLACEMENT.
b. POST-INSTALLED ANCHORS
c. REINFORCING STEEL PLACING
PART VIII - SUBMITTALS
A. SUBMITTAL LIST AND SCHEDULE
1. THE CONTRACTOR SHALL PREPARE A DETAILED LIST AND SCHEDULE OF ALL
SUBMITTAL ITEMS TO BE SENT TO THE STRUCTURAL ENGINEER PRIOR TO THE START
OF CONSTRUCTION. THIS LIST SHALL BE UPDATED AND REVISED AND KEPT CURRENT
AS THE JOB PROGRESSES. THE SUBMITTAL LIST SHALL BE ORGANIZED AS SHOWN
BELOW:
a. SHOP DRAWINGS
b. DESIGN CALCULATIONS
c. PRODUCT TECHNICAL DATA
d. PRODUCT MSDS/SDS
e. CERTIFICATES, REPORTS, AND OTHER LITERATURE
B. SUBMITTALS TO BE PROVIDED TO STRUCTURAL ENGINEER
1. PRODUCT SUBMITTALS: IN ADDITION TO THE SUBMITTALS REQUIRED BY THE
PROJECT SPECIFICATIONS, THE FOLLOWING SUBMITTALS SHALL BE PROVIDED:
a. CONCRETE REPAIR MATERIALS.
b. BOLTS, RODS, NUTS, WASHERS AND ASSOCIATED COMPONENTS.
c. EXPANSION JOINT SYSTEM.
d. JOINT SEALANTS (HORIZONTAL, VERTICAL, AND COVE).
e. STRUCTURAL STEEL
2. DEFERRED SUBMITTALS:
a. THE FOLLOWING ITEMS ARE CONSIDERED DEFERRED SUBMITTALS BY THE
REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE:
1) SHORING (S&S, REC)
NOTES:
(S&S) ITEMS MARKED THUS SHALL HAVE THE SHOP DRAWINGS AND
DELEGATED DESIGN SUBMITTALS (INCLUDING CALCULATIONS) SEALED PER
THE PROJECT SPECIFICATIONS BY AN ENGINEER REGISTERED IN THE
STATE WHERE THE PROJECT IS LOCATED.
(REC)ITEMS MARKED THUS SHALL BE SUBMITTED TO ENGINEER FOR
RECORD ONLY AND WILL NOT HAVE THE ENGINEER’S SHOP DRAWING STAMP
AFFIXED.
b. DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO
THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE FORWARDED TO THE
BUILDING OFFICIAL.
c. DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
OFFICIAL.
3. SUBMITTAL REQUIREMENTS:
a. ALL SHOP DRAWINGS MUST BE REVIEWED AND ELECTRONICALLY STAMPED
BY THE CONTRACTOR PRIOR TO SUBMITTAL.
b. CONTRACTOR SHALL PROVIDE THE SUBMITTAL IN ELECTRONIC PORTABLE
DOCUMENT FORMAT (PDF) PER THE SPECIFICATIONS.
c. THE OMISSION FROM THE SHOP DRAWINGS OF ANY MATERIALS REQUIRED
BY THE CONTRACT DOCUMENTS TO BE FURNISHED SHALL NOT RELIEVE THE
CONTRACTOR OF THE RESPONSIBILITY OF FURNISHING AND INSTALLING SUCH
MATERIALS, REGARDLESS OF WHETHER THE SHOP DRAWINGS HAVE BEEN
REVIEWED AND APPROVED.
C. REPRODUCTION
1. THE USE OF ELECTRONIC FILES OR REPRODUCTIONS OF THESE CONTRACT
DOCUMENTS BY ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR, OR
MATERIAL SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFIES
THEIR ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT, AND
OBLIGATES THEMSELVES TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO
ANY ERRORS THAT MAY OCCUR HEREON.
PART IX - MISCELLANEOUS
A. CONTRACT DOCUMENTS
1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL CONTRACT
DOCUMENTS AND LATEST ADDENDA AND TO SUBMIT SUCH DOCUMENTS TO ALL
SUBCONTRACTORS AND MATERIAL SUPPLIERS PRIOR TO THE SUBMITTAL OF SHOP
DRAWINGS, FABRICATION OF ANY STRUCTURAL MEMBERS, AND ERECTION IN THE
FIELD.
2. CONTRACTOR SHALL FULLY AND PROPERLY IMPLEMENT THE ENGINEERING
CONTROLS, WORK PRACTICES, AND RESPIRATORY PROTECTION AGAINST TOXIC AND
HAZARDOUS SUBSTANCES INCLUDING RESPIRABLE CRYSTALLINE SILICA ACCORDING
TO OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, OSHA 1926.1153. WALTER
P MOORE DOES NOT HAVE CONTROL OVER, CHARGE OF, OR RESPONSIBILITY FOR THE
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR
SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, NOR SHALL
WALTER P MOORE BE RESPONSIBLE FOR THE CONTRACTOR’S FAILURE TO PERFORM
THE WORK IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
3. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
REPAIRED STRUCTURE, AND, EXCEPT WHERE SPECIFICALLY SHOWN, DO NOT
INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL
SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, AND SEQUENCE.
4. REFER TO DRAWINGS OF EXISTING FACILITY (OTHER THAN REPAIR
DRAWINGS) FOR COMPLETE INFORMATION INCLUDING: EXPANSION JOINT SYSTEMS,
PREVIOUS REPAIRS PERFORMED IN THE FACILITY, PRESENCE OF POST-TENSIONING,
LOCATION AND SIZE OF STRUCTURAL MEMBERS (BEAMS, COLUMNS, WALLS, ETC.),
SLAB THICKNESS, AND OTHER INFORMATION RELEVANT TO THE PROJECT.
5. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR SPECIFIED ON THE
DRAWINGS OR IN THE SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE
SAME CHARACTER AS SHOWN OR SPECIFIED IN SIMILAR CONDITIONS.
B. EXISTING CONDITIONS
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE
EXISTING BUILDING AT THE JOB SITE AND REPORT ANY DISCREPANCIES FROM
ASSUMED CONDITIONS SHOWN ON THE DRAWINGS TO ENGINEER PRIOR TO THE
FABRICATION AND ERECTION OF ANY MEMBERS. EXISTING DIMENSIONS SHOWN ON
THE DRAWINGS ARE FOR GENERAL REFERENCE ONLY AND SHOULD NOT BE USED FOR
FINAL CONSTRUCTION OR DETAILING.
PART IX - MISCELLANEOUS (CONTINUED)
C. RESPONSIBILITY OF THE CONTRACTOR FOR STABILITY OF THE STRUCTURE DURING
CONSTRUCTION
1. REPAIRS OF STRUCTURAL ELEMENTS OF THE PROJECT HAVE BEEN DESIGNED
BY THE STRUCTURAL ENGINEER TO RESIST THE REQUIRED CODE VERTICAL AND
LATERAL FORCES THAT COULD OCCUR IN THE FINAL REPAIRED STRUCTURE ONLY.
THE ABILITY OF THE STRUCTURAL FRAME TO RESIST THE REQUIRED CODE FORCES
DERIVES FROM THE COMPLETE INSTALLATION OF THE REPAIRS. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL REQUIRED BRACING DURING
CONSTRUCTION TO MAINTAIN THE STABILITY AND SAFETY OF ALL STRUCTURAL
ELEMENTS DURING THE CONSTRUCTION PROCESS UNTIL THE REPAIR WORK IS
COMPLETELY INSTALLED AND ALL DESIGNATED CONCRETE ELEMENTS (IF ANY) HAVE
REACHED A MINIMUM OF 75% OF THEIR DESIGN STRENGTH.
D. RESPONSIBILITY OF THE CONTRACTOR FOR CONSTRUCTION LOADS
1. THE REPAIRS HAVE BEEN DESIGNED FOR THE LOADS IDENTIFIED WITHIN
THESE DRAWINGS THAT ARE ANTICIPATED TO BE APPLIED TO THE STRUCTURE WORK
IS COMPLETED. THE CONTRACTOR SHALL NOT OVERLOAD THE STRUCTURE DURING
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING THE
ADEQUACY OF THE STRUCTURE TO SUPPORT ANY APPLIED CONSTRUCTION LOADS,
INCLUDING THOSE DUE TO CONSTRUCTION VEHICLES OR EQUIPMENT, MATERIAL
HANDLING OR STORAGE, SHORING OR RESHORING, OR ANY OTHER CONSTRUCTION
ACTIVITY. THE CONTRACTOR SHALL SUBMIT CALCULATIONS SIGNED AND SEALED BY
AN ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED VERIFYING
THE ADEQUACY OF THE STRUCTURE FOR ANY PROPOSED CONSTRUCTION LOADS THAT
ARE IN EXCESS OF THE DESIGN LOADS STATED IN THE RECORD DRAWINGS. THE
STRUCTURAL ENGINEER IS NOT RESPONSIBLE TO DESIGN OR CHECK THE STRUCTURE
FOR LOADS APPLIED TO THE STRUCTURE FOR ANY CONSTRUCTION ACTIVITY.
E. CONTRACTOR SUBSTITUTIONS
1. ANY MATERIALS OR PRODUCTS SUBMITTED FOR APPROVAL THAT ARE
DIFFERENT FROM THE MATERIAL OR PRODUCTS SPECIFIED IN THE STRUCTURAL
CONTRACT DOCUMENTS WILL BE CONSIDERED FOR APPROVAL ONLY IF THE FOLLOWING
CRITERIA ARE SATISFIED:
a. A COST SAVINGS TO THE OWNER IS DOCUMENTED AND SUBMITTED WITH
THE REQUEST.
b. THE MATERIAL OR PRODUCT HAS BEEN APPROVED BY THE
INTERNATIONAL CODE COUNCIL (ICC) AND THE ICC REPORT IS SUBMITTED
WITH THE REQUEST.
1) THE ICC ESR THAT IS SUBMITTED MUST REFERENCE THE BUILDING
CODE UNDER WHICH THE PROJECT IS PERMITTED.
2) ICC REPORTS THAT HAVE BEEN DISCONTINUED AT THE TIME OF
PRODUCT INSTALLATION WILL NOT BE ACCEPTED.
2. SUBMITTALS NOT SATISFYING THE ABOVE CRITERIA WILL NOT BE
CONSIDERED.
F. THE STRUCTURAL ENGINEER’S ROLE DURING CONSTRUCTION
1. THE ENGINEER SHALL NOT HAVE CONTROL NOR CHARGE OF, AND SHALL NOT
BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES,
OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH
THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR, OR
ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY
OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
2. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF WALTER P.
MOORE AND ASSOCIATES IS SOLELY FOR THE PURPOSE OF BECOMING GENERALLY
FAMILIAR WITH THE PROGRESS AND QUALITY OF THE WORK COMPLETED AND
DETERMINING, IN GENERAL, IF THE WORK OBSERVED IS BEING PERFORMED IN A
MANNER INDICATING THAT THE WORK, WHEN FULLY COMPLETED, WILL BE IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION
SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY
OR QUANTITY OF THE WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE
OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF THE CONTRACTOR.
G. MAINTENANCE STATEMENT
1. ALL STRUCTURES REQUIRE PERIODIC MAINTENANCE TO EXTEND LIFESPAN AND
TO ENSURE STRUCTURAL INTEGRITY FROM EXPOSURE TO THE ENVIRONMENT. A
PLANNED PROGRAM OF MAINTENANCE SHALL BE ESTABLISHED BY THE BUILDING
OWNER. THIS PROGRAM SHALL INCLUDE ITEMS SUCH AS BUT NOT LIMITED TO
PAINTING OF STRUCTURAL STEEL, PROTECTIVE COATING FOR CONCRETE,
REPLACEMENT OF FAILED SEALANTS, CAULKED JOINTS, EXPANSION JOINTS,
CONTROL JOINTS, REPAIR OF SPALLS AND CRACKS IN CONCRETE, AND PRESSURE
WASHING OF EXPOSED STRUCTURAL ELEMENTS EXPOSED TO A HUMID ENVIRONMENT.
H. CONSTRUCTION SAFEGUARDS
1. CONSTRUCTION SAFEGUARDS GOVERNING SAFETY DURING CONSTRUCTION, THE
PROTECTION OF ADJACENT PUBLIC AND PRIVATE PROPERTIES, PROTECTION OF
BUILDING OCCUPANTS, AND PROTECTION OF PEOPLE ADJACENT TO THE
CONSTRUCTION AREA SHALL BE PER REQUIREMENTS OF THE BUILDING CODE AS
ADOPTED BY THE AUTHORITY HAVING JURISDICTION OVER THE LOCATION OF THE
WORK.
GENERAL STRUCTURAL NOTES
PART X - DRAWING INTERPRETATION
A. DRAWING VIEWS LABELED AS “TYPICAL”
1. PARTIAL PLANS, ELEVATIONS, SECTIONS, DETAILS, OR SCHEDULES LABELED
WITH “TYPICAL” AT THE BEGINNING OF THEIR TITLE SHALL APPLY TO ALL
SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO
THOSE SPECIFICALLY SHOWN. THE APPLICABILITY OF THE CONTENT OF THESE
VIEWS TO LOCATIONS ON THE PLAN CAN BE DETERMINED FROM THE TITLE OF THE
VIEWS. SUCH VIEWS SHALL APPLY WHETHER OR NOT THEY ARE KEYED IN AT EACH
LOCATION. DECISIONS REGARDING APPLICABILITY OF THESE “TYPICAL” VIEWS
SHALL BE DETERMINED BY THE STRUCTURAL ENGINEER.
B. STRUCTURAL ABBREVIATIONS, SYMBOLS, AND NOTATIONS
@ AT
& AND
# NUMBER
Ø ROUND, DIAMETER
' FT
" IN.
(E) EXISTING
(N) NEW
ACI AMERICAN CONCRETE INSTITUTE
AISC AMERICAN INSTITUTE FOR STEEL CONTRUCTION
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
BLDG BUILDING
BOT BOTTOM
CJ CONTROL JOINT
COL COLUMN
CONC CONCRETE
DN DOWN
EA EACH
ELEV ELEVATION
EJ EXPANSION JOINT
EW EACH WAY
EXIST EXISTING
F’C SPECIFIED CONCRETE COMPRESSIVE STRENGTH
FT FT
FV FIELD VERIFY
FY YIELD STRENGTH
FU ULTIMATE STRENGTH
GEN GENERAL
HORZ HORIZONTAL
ICRI INTERNATIONAL CONCRETE REPAIR INSTITUTE
IN INCH
INFO INFORMATION
KIPS 1000 POUNDS FORCE
KSI KIPS PER SQUARE IN.
LBF POUNDS FORCE
MAX MAXIMUM
MIN MINIMUM
MISC MISCELLANEOUS
MSD MATERIAL SAFETY DATA
MSDS MATERIAL SAFETY DATA SHEET
NTS NOT TO SCALE
OC ON CENTER
PLF POUNDS PER LINER FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE IN.
QTY QUANTITY
REINF REINFORCEMENT
REQD REQUIRED
SHT SHEET
SIM SIMILAR
SPA SPACING
STD STANDARD
TI TASK ITEM
TOC TOP OF CONCRETE
TOS TOP OF STEEL, TOP OF SLAB
TYP TYPICAL
VERT VERTICAL
WT WEIGHT
C. STRUCTURAL SYMBOLS
1. TASK ITEMS ARE INDICATED BY:
3. REGULATORY REQUIREMENTS: COMPLY WITH GOVERNING OWNER, LOCAL,
STATE, FEDERAL, AND EPA NOTIFICATIONS AND REGULATIONS BEFORE BEGINNING
SELECTIVE DECONSTRUCTION / DEMOLITION. COMPLY WITH HAULING AND DISPOSAL
REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
A
B
123456789101112131415
333'-5" (FV)
12'-1 15/16" (FV) 15'-0 9/16" (FV) 8'-6" (FV)
27'-2 1/2" (FV) 65'-1" (FV) 148'-10" (FV) PRESS BOX 65'-1" (FV) 27'-2 1/2" (FV)
21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 23'-6 9/16" (FV) 12'-1 15/16" (FV)
8'-6" (FV) 15'-0 9/16" (FV)
/8
(F V
/8
(F
V
/8
(F
V
/2
(F
V
8'-6" (FV)
(F
V
W
A L
L
F V
(F
V
(F
V
(F V
(F
V
(F
V
(F
V
/2
(F
V
R O
W S
(F
V
(F
V
(F
V
/2
(F V
W
A L
L
8'-6 7/8" (FV) 139'-6" (FV) 139'-6" (FV)
74'-5 1/2" (FV) 10'-11" (FV) 63'-6 1/2" (FV)
1.0 5.0
5.0 1.0
1.0
5.0
5.0
1.05.0
1.0
1.0
5.0
2.0A
1.0 4.0
6.5
1.0
5.0
5.0
1.0
5.0
5.0
1.0
1.0
6.5
5.0
5.0 5.0 5.0
2.0B
5.0
5.0
1.0
8/S-301
1.0 1.0
1.0
9.0 5.0 3.0
5.0
1.0
5.0
6.5
S-300
S-300
S-300
TYP
TYP
TYP
NOTE:
1. TAG NUMBER REPRESENT THE TASK ITEM CORRESPONDING TO A REPAIR DETAIL PROCEDURE, SEE BELOW FOR TABLE:
S-301
TASK ITEM
1.0
2.0A
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
7/S-301
4/S-300
5/S-300
9/S-300
8/S-300
10/S-300
12/S-300
14/S-300
3/S-301
ACTION/DETAILED INFORMATION
2/S-300
6.5 17/S-300
(F V
(F
V
R O
W S
(F
V
' 1
(F V
(F V
(F
V
(F V
(F
V
(F
V
R O
W S
(F V
(F
V
(F V
(F
V
R O
W A
(F V
(F
V
(F V
(F V
/1
(F
V
(F
V
(F
V
(F
V
W
A L
L
F V
REFER TO S-104
FOR PRESSBOX
EXPANDED PLAN
S-301
TYPICAL SHORING AT
CANILEVER AREA, REFER
TO
LOAD TABLE - 2 ON 15/S301
FOR SHORING LOADS
AND LOCATIONS
POINT 3
POINT 4
/1
(F
V
2.0B 8/S-301
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:4
P M
3/32" = 1'-0"
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
WEST STANDS FRAMING PLAN - SOFFIT
REPAIRS
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
S-100
NO SCALE1
WEST STANDS FRAMING PLAN - SOFFIT REPAIRS
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
(F V
(F
V
333'-5" (FV)
12'-1 15/16" (FV)15'-0 9/16" (FV)8'-6" (FV)
27'-2 1/2" (FV)279'-0" (FV)27'-2 1/2" (FV)
21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)23'-6 9/16" (FV)12'-1 15/16" (FV)
8'-6" (FV)15'-0 9/16" (FV)
/8
(F V
/8
(F
V
/8
(F
V
/2
(F
V
1'-11 7/16" (FV)
13'-1 1/8" (FV)8'-6" (FV)
(F
V
(F
V
W
A L
L
F V
(F
V
(F
V
(F V
(F
V
(F V
8'-6 7/8" (FV) 84'-10 1/2" (FV) 1" (FV) 54'-6 1/2" (FV) 54'-6 1/2" (FV) 1" (FV) 84'-10 1/2" (FV) 8'-6 7/8" (FV)
296'-1 3/4" (FV)
5.0
1.0
5.0
5.0
1.0
5.0
1.0
5.0
6.5
1.0 1.0
5.0
5.0 3.0
1.0
6.5
5.0
1.0
5.0 5.0
1.0
5.0
1.0 10.0
1.0
5.0
5.0
1.0
10.0
1.0
1.0
1.0
1.0
1.01.0
5.0
S-300
TYP
S-300
TYP
NOTE:
1. TAG NUMBER REPRESENT THE TASK ITEM CORRESPONDING TO A REPAIR DETAIL PROCEDURE, SEE BELOW FOR TABLE:
TASK ITEM
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
7/S-301
4/S-300
5/S-300
9/S-300
8/S-300
10/S-300
12/S-300
14/S-300
3/S-301
ACTION/DETAILED INFORMATION
2/S-300
6.5 17/S-300
(F
V
(F
V
(F
V
(F
V
W
A L
L B
E L
O W
F
V
(F V
(F
V
R O
W S
(F
V
(F
V
(F
V
R O
W S
(F
V
(F
V
(F V
(F
V
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:4
P M
3/32" = 1'-0"
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
EAST STANDS FRAMING PLAN - SOFFIT
REPAIRS
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
S-101
NO SCALE1
EAST STANDS FRAMING PLAN - SOFFIT REPAIRSN
C
D
E
F
123456789101112131415
333'-5" (FV)
12'-1 15/16" (FV) 15'-0 9/16" (FV) 8'-6" (FV)
27'-2 1/2" (FV) 65'-1" (FV) 148'-10" (FV) PRESS BOX 65'-1" (FV) 27'-2 1/2" (FV)
21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 21'-10" (FV) 23'-6 9/16" (FV) 12'-1 15/16" (FV)
8'-6" (FV) 15'-0 9/16" (FV)
8'-6 7/8" (FV) 139'-6" (FV) 139'-6" (FV)
74'-5 1/2" (FV) 10'-11" (FV) 63'-6 1/2" (FV)
3.0
6.0 7.0 5.0
6.0
3.0
6.0
4.0
9.03.0 3.0
3.0
3.0
3.0 3.0
3.0
3.0
3.0
3.03.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
5.0
3.0
5.0
3.0
3.0 5.0 3.03.0
NOTE:
1. TAG NUMBER REPRESENT THE TASK ITEM CORRESPONDING TO A REPAIR DETAIL PROCEDURE, SEE BELOW FOR TABLE:
TASK ITEM
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
7/S-301
4/S-300
5/S-300
9/S-300
8/S-300
10/S-300
12/S-300
14/S-300
3/S-301
ACTION/DETAILED INFORMATION
2/S-300
6.5 17/S-300
(F V
(F
V
R O
W S
(F V
(F
V
(F V
(F
V
(F
V
(F
V
(F
V
(F
V
(F
V
(F V
R O
W A
(F
V
/2
(F
V
(F
V
(F
V
(F
V
(F V
(F V
F V
(F
V
(F
V
W
A L
L
F V
(F V
(F
V
R O
W S
(F V
(F
V
(F
V
(F
V
(F
V
(F
V
W
A L
L
F V
S-300
TYP
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:4
P M
3/32" = 1'-0"
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
WEST STANDS FRAMING PLAN - TOP
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
S-102
NO SCALE1
WEST STANDS FRAMING PLAN - TOP
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
333'-5" (FV)
12'-1 15/16" (FV)15'-0 9/16" (FV)8'-6" (FV)
27'-2 1/2" (FV)279'-0" (FV)27'-2 1/2" (FV)
21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)21'-10" (FV)23'-6 9/16" (FV)12'-1 15/16" (FV)
8'-6" (FV)15'-0 9/16" (FV)
8'-6 7/8" (FV) 84'-10 1/2" (FV) 1" (FV) 54'-6 1/2" (FV) 54'-6 1/2" (FV) 1" (FV) 84'-10 1/2" (FV) 8'-6 7/8" (FV)
296'-1 3/4" (FV)
3.0
3.0
9.0
3.0 3.0 3.0 3.0
3.0
3.0
3.0
3.0
3.0
3.0 3.0
3.0
3.0
3.0
9.0
3.0
5.0
NOTE:
1. TAG NUMBER REPRESENT THE TASK ITEM CORRESPONDING TO A REPAIR DETAIL PROCEDURE, SEE BELOW FOR TABLE:
TASK ITEM
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
7/S-301
4/S-300
5/S-300
9/S-300
8/S-300
10/S-300
12/S-300
14/S-300
3/S-301
ACTION/DETAILED INFORMATION
2/S-300
6.5 17/S-300
(F
V
(F
V
(F
V
(F
V
(F V
(F
V
R O
W S
(F
V
(F
V
(F
V
R A
W S
(F
V
(F
V
(F V
(F
V
6.0 6.0
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:5
P M
3/32" = 1'-0"
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
EAST STANDS FRAMING PLAN - TOP
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
S-103
NO SCALE1
EAST STANDS FRAMING PLAN - TOPN
10'-11" 10'-3" 10'-0" 10'-0" 10'-0" 15'-0" 15'-0" 15'-0" 10'-0" 20'-0" 10'-3" 10'-11"
/2
149'-0"
/2
4'-0"
8.0 SHORING POST, REF
GENERAL NOTES
/2
/2
NOTE:
1. TAG NUMBER REPRESENT THE TASK ITEM CORRESPONDING TO A REPAIR DETAIL PROCEDURE, SEE BELOW FOR TABLE:
TASK ITEM
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0 9.0
10.0
7/S-301
4/S-300
5/S-300
9/S-300
8/S-300
10/S-300
12/S-300 14/S-300
3/S-301
ACTION/DETAILED INFORMATION
2/S-300
6.5 17/S-300
EXISTING STEEL
FRAMING, TYP
EXISTING
CONCRETE
COLUMN,TYP
CONTRACTOR TO
REFER TO AISC
5TH EDITION FOR
DIMENSIONS OF
EXISTING BEAMS
EXISTING 8B13
EXISTING 8B13 EXISTING 8B13 EXISTING 8B13 EXISTING 8B13 EXISTING 8B13
EXISTING 8B13
EXISTING 8B13
EXISTING 8B13EXISTING 8B13 EXISTING 8WF17 EXISTING 8WF17 EXISTING 8WF17
EXISTING 8WF17EXISTING 8WF17EXISTING 8WF17
C
.4
EXISTING 8B13
EXISTING 8B13 EXISTING 8B13
EXISTING 8B13 EXISTING 8B13 EXISTING 8B13
EXISTING WF31
EXISTING 8B13
EXISTING 8B13
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Title
Client/Project
Client/Project Logo
Issued/Revision By Appd YYYY.MM.DD
A
5 4 3 2 1
B
C
D
E
Revision
Project No. Scale
Drawing No.
Issue Status
Stantec Architecture, Inc.
1100 Louisiana Street, Suite One
Houston, Texas 77002, Tel: 713 871 8484 • www.stantec.com
Walter P Moore and Associates, Inc.
1301 McKinney Street, Suite 1100 Houston, TX 77010 TBPE Firm Registration No. 1856 713.630.7300
11/06/2026
/4 /2
:1
:5
P M
3/16" = 1'-0"
4400 S Martin Luther King Jr Pkwy
Beaumont, TX 77705
PRESS BOX LOWER LEVEL ROOF
FRAMING PLAN
Lamar University
LAMAR UNIVERSITY, FOOTBALL STADIUM
REPAIRS
234601127
S-104
N
NO SCALE1
PRESS BOX LOWER LEVEL ROOF FRAMING PLAN
CANTILEVERCANTILEVER
B B
A A
A
A
A A
ROUGHEN EXISTING
CONCRETE SURFACE
TO CSP 6. REFER TO
SPECIFICATIONS
REMOVE AND REPLACE
CONCRETE WITHIN
SHADED SECTION
SHOWN (TYP.)
CORNER PROFILE TO MATCH
EXISTING CONDITION
REMOVAL LIMITS (TYP.)
GRIND, CHIP, OR SAW CUT
AROUND PATCH PERIMETER
TO AT LEAST 1/2" BEYOND THE
SPALL/DELAMINATION OR UP
TO SOUND CONCRETE. INITIAL
GRINDING OR SAW CUTTING
SHALL BE PERPENDICULAR TO
SURFACE (TYP.)
REINFORCEMENT
LOCATIONS
APPROXIMATE (TYP.)
PROVIDE AUGMENTATION
IF REQUIRED. SEE 2/S-301
& 3/S-301
NOTES:
1. PROTECT EXISTING REINFORCEMENT FROM DAMAGE DURING CHIPPING, GRINDING
OR SAW CUTTING FOR SPALL/DELAMINATION REPAIR.
2. REFER TO SECTION "SURFACE PREPARATION FOR PATCHING" FOR CLEANING AND
COATING ALL EXPOSED REINFORCEMENT.
3. PROVIDE 3/4" CLEARANCE AROUND ALL EXPOSED REINFORCEMENT WHERE
REQUIRED AS SPECIFIED IN SECTION "SURFACE PREPARATION FOR PATCHING."
4. WHERE DIMENSION "A" SHOWN IN DETAIL IS 4" OR LESS, THEN REPAIR ENTIRE WIDTH
OF BEAM.
A
M A
X
VARIES VARIES
FIELD VERIFY
WIDTH OF
EXISTING BEAM
M A
X V
A R
IE
S
VARIES
SEE (NOTE 4) BELOW
SPALL OR
DELAMINATION
(TYP.)
NOTES:
1. PROTECT EXISTING REINFORCEMENT FROM DAMAGE DURING CHIPPING, GRINDING
OR SAW CUTTING FOR SPALL/DELAMINATION REPAIR.
2. REFER TO SECTION "SURFACE PREPARATION FOR PATCHING" FOR CLEANING AND
COATING ALL EXPOSED REINFORCEMENT.
3. PROVIDE 3/4" CLEARANCE AROUND ALL EXPOSED REINFORCEMENT WHERE
REQUIRED AS SPECIFIED IN SECTION "SURFACE PREPARATION FOR PATCHING."
4. PROVIDE SHORING AS SPECIFIED BY ENGINEER PRIOR TO COMMENCEMENT OF
ANY CONCRETE REMOVAL WORK.
5. NEW PATCH SHALL MATCH EXISTING FINISH.
REMOVE AND REPLACE
CONCRETE WITHIN SHADED
SECTION SHOWN
CHIP, GRIND OR SAW CUT AROUND
PATCH PERIMETER FOR AT LEAST
1/2" BEYOND THE
SPALL/DELAMINATION OR UP TO
SOUND CONCRETE. INITIAL
GRINDING OR SAW CUTTING SHALL
BE PERPENDICULAR TO SURFACE
FACE OF WALL
REINFORCEMENT LOCATIONS
APPROXIMATE (TYP.)
PROVIDE AUGMENTATION IF
REQUIRED. SEE 2/S-301
SPALL OR
DELAMINATION (TYP.)
REMOVAL LIMITS, ROUGHEN
EXISTING CONCRETE SURFACE
TO CSP 6. REFER TO
SPECIFICATIONS
INSTALL
PATCH FLUSH
WITH WALL
PAINT AS
REQUIRED
DO NOT OVERCUT CORNERS
SPALL OR DELAMINATION
REMOVAL LIMITS
EXISTING REINFORCEMENT
WALL ELEVATION
SECTION A-A
V A
R
IE
S
2" MAX
SPALL OR
DELAMINATION
EXISTING REINF APPROX.
LOCATIONS (TYP.)
APPROXIMATE EXTENT OF
HORIZONTAL AND VERTICAL
REMOVAL LIMITS
ELEVATION
V A
R
IE
S
NOTES:
1. PROTECT EXISTING REINFORCEMENT FROM DAMAGE DURING CHIPPING, GRINDING
OR SAW CUTTING FOR SPALL/DELAMINATION REPAIR.
2. REFER TO SECTION "SURFACE PREPARATION FOR PATCHING" FOR CLEANING AND
COATING ALL EXPOSED REINFORCEMENT.
3. PROVIDE 3/4" CLEARANCE AROUND ALL EXPOSED REINFORCEMENT WHERE
REQUIRED AS SPECIFIED IN SECTION…