ESBD_517847_1779202161267_ATTACHMENT G.4 Mandatory Pricing Schedule.xlsx

XLSX spreadsheet 24 KB Posted

Attached to
Tube Heater Replacements
Solicitation number
TMD26-FMO-0043725
Issued by
Dallas County, Texas

About this file

This is a Mandatory Pricing Schedule attachment for a procurement by the Texas Military Department (TMD) under contract number TMD26-FMO-0043725 for tube heater replacements at Field Maintenance Shop (FMS) 16 located at 1012 Lake Crest Drive, Grand Prairie, Texas 75051. The project involves the removal of three existing Detroit Radiant tube heaters (Model HL50-175N) and installation of eight new Dayton Radiant tube heaters (Model 5VD63A), which will be supplied by TMD. The scope of work encompasses seven distinct line items classified under NIGP Class 910-82 (Wiring and Other Electrical Maintenance and Repair Services), including disconnecting and removing existing heaters and associated components, upgrading gas piping from 1.25 inches to 2 inches, extending 120-volt electrical circuits, installing 60,000 BTUH/24-volt stepdown transformers with control circuits, re-routing thermostat wiring, and restoring all electrical and gas utility services in compliance with local utility provider requirements.

The pricing schedule is presented in a template format with seven job-based line items, each requiring bidders to submit unit prices and extended prices; however, all pricing fields are currently populated with $0, indicating this is a blank template awaiting contractor proposals. Bidders must ensure all proposed items meet the requirements outlined in Section C—Statement of Work and are restricted from modifying any cells other than those highlighted in yellow for data entry, with non-compliance potentially resulting in proposal disqualification. The contract is classified under wiring and electrical maintenance and repair services, with all materials for the new Dayton heaters and related equipment to be supplied by TMD.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pricing Schedule

Texas Military Department
Procurement and Contract Services (P&CS)
TMD26-FMO-0043725 Tube Heater Replacements
ATTACHMENT G.4 Mandatory Pricing Schedule
Company Name:
Company Point Of Contact:
Contact Phone #:
Contact Email:

Items proposed below must meet the Statement of Work described in SECTION C - Statement of Work. Cells highlighted in yellow permit data entry. Please DO NOT add, delete or change any other cells. Doing so may subject your proposal to disqualification.

Line Item Details

Item #NIGP Class and ItemItem Description
QuantatyUnit of Measure (UOM)Estimated Days To Completion AROUnit PriceExtended Price
1910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesThe Texas Military Department (TMD) is seeking competitive Bids from highly qualified Contractors to remove Detroit Radiant tube heaters (Model HL50-175N) and install new Dayton Radiant tube heaters (Model 5VD63A), supplied by TMD.

Located at the Field Maintenance Shop (FMS) 16, 1012 Lake Crest Drive, Grand Prairie, Texas 75051.

Contractor must disconnect electrical and gas service to the existing three (3) Detroit radiant tube heaters (Model HL50-175N).1JOB$0
2910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesContractor must remove three (3) existing Detroit radiant tube heaters (Model HL50-175N), three (3) reflectors, three (3) vent pipes, three (3) flexible gas supply lines, and all of the supports that hold the equipment stated above.1JOB$0
3910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesContractor must remove the existing one and a quarter inch (1.25”) gas piping and install a two-inch (2”) gas piping to the eight (8) new Dayton Radiant tube heaters (Model 5VD63A), supplied by TMD.1JOB$0
4910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesContractor must extend the existing 120 volts circuit to connect to the eight (8) new Dayton Radiant tube heaters (Model 5VD63A), supplied by TMD.1JOB$0
5910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesContractor must install eight (8) new 60,000 British Thermal Units per Hour (BTUH)/24-volt stepdown transformers control circuit and connect to each new Dayton radiant heaters (Model 5VD63A). TMD will supply the eight (8) new Dayton radiant heaters (Model 5VD63A).1JOB$0
6910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesContractor must re-route the Thermostat (T-stat) wiring to accommodate the eight (8) new Dayton Radiant tube heaters (Model 5VD63A), supplied by TMD.1JOB$0
7910 - 82 Wiring and Other Electrical Maintenance and Repair ServicesContractor must restore the electrical and gas utility services and confirm the services are operational in compliance with local utility provider requirements.1JOB$0
Total:$0