ESBD_504019_1775484433594_Pressure_transducer_specifications.pdf
PDF 80 KB Posted
- Attached to
- Pressure Transducer
- Solicitation number
- 580-26-IFB-5138
- Issued by
- Travis County, Austin City, Texas
About this file
This is a technical specifications document for a pressure transducer device related to a Texas state or local contract opportunity. The pressure transducer is designed for water-level measurement with a measurement time of less than 1.5 seconds and offers multiple output options including SDI-12 (version 1.3) at 1200 bps and RS-232 at 9600 bps. The device operates within a temperature range of 0 to 60 degrees Celsius with a temperature accuracy of 0.2 degrees Celsius and features a water-level resolution of 0.0035% full-scale range. The sensor is equipped with an overpressure rating of 2 times the pressure range and requires power input between 6 to 18 volts DC, with quiescent power consumption below 50 microamps and active measurement/communication consumption up to 8 milliamps for a one-second measurement cycle, with a maximum of 40 milliamps.
The high-accuracy option for this pressure transducer provides a total error band of 0.05% full-scale range, which accounts for combined errors from nonlinearity, hysteresis, nonrepeatability, and thermal effects across the compensated temperature range per ISA S51.1 standards. The device supports a maximum cable length of approximately 457 meters (1500 feet) when a single SDI-12 sensor is connected to a port. A critical operational warning notes that the sensor could be damaged if encased in frozen ice, which is an important consideration for deployment in certain climates.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_504019_1775484046533_580-26-IFB-5138.pdf | ||
| ESBD_504019_1775484382667_GENERAL TERMS AND CONDITIONS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pressure Transducer Specifications
Measurement Time < 1.5 s
Output Options SDI-12 (version 1.3) 1200 bps; RS-232 9600 bps
Water-Level Resolution 0.0035% FS
Worst-Case Temperature Resolution 0.006°C
Operating Temperature Range 0° to 60°C WARNING: Sensor could be damaged if encased in frozen ice.
Temperature Accuracy ±0.2°C
Overpressure 2 x pressure range
Power Requirements 6 to 18 Vdc
Power Consumption
Quiescent < 50 µA
Measurement/Communication 8 mA (1 s measurement)
Maximum 40 mA
Accuracy
High Accuracy Option
±0.05% full-scale-range TEB
Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.
Physical
Maximum cable length
• ~457 m (1500 ft)
1 SDI-12 sensor connected to a single port
Diameter • <21. 4 mm (0.85 in.)
Ingress Protection • Exceeds IP68
Barometric compensation • Vented cable