ESBD_482244_1768242260434_HHS0016958_Exhibit C - Pricing Sheet .xlsx
XLSX spreadsheet 24 KB Posted
- Attached to
- Skalar San ++ Continuous Analyzer
- Solicitation number
- HHS0016958
- Issued by
- Travis County, Austin City, Texas
About this file
This is a pricing sheet exhibit (Exhibit C) for a formal Invitation for Bid (IFB No. HHS0016958) issued by the Texas Department of State Health Services (DSHS) for laboratory analytical equipment and components. The procurement requests a comprehensive water analysis system including one random access sampler (SAN++ model), one classic module holder with integrated electronics, one personal computer with monitor, one international keyboard, and multiple analysis modules for detecting cyanide, silicate, nitrate+nitrite, and nitrite in water samples. The bid also includes two dual-channel digital photometer detector heads, flow cells, filters, a pre-dilution step module, and an analyzer start-up kit with accessories. All equipment is to be shipped to the DSHS Lab Warehouse located at 1100 W 49th, Lab Dock L 114 in Austin, Texas. The response due date is January 28, 2026 at 10:30 AM, with an estimated delivery time of 14 days after receipt of order.
All pricing in the exhibit is currently listed as zero dollars, indicating that this is a blank pricing sheet template awaiting vendor submission of costs. The quote terms specify F.O.B. Destination with freight prepaid and included in the total price, or vendors must show exact delivery costs and alternative terms if applicable. No pricing information, set-asides, incumbent contractor details, or funding source information is currently populated in this document, as it represents the pricing structure vendors must complete upon submission of their bids.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit C - One Time Purchase
| EXHIBIT C | |||||||
| PRICING SHEET | |||||||
| Formal IFB No: HHS0016958 | Response Due Date: 01-28-2026 @ 10:30AM | ||||||
| Ship To: | Vendor Details: | ||||||
| DSHS Lab Warehouse | |||||||
| 1100 W 49th; LabDock L 114 | |||||||
| Austin, TX 78756 | |||||||
| Line No. | Class-Item | Part Number | Description | Qty | UOM | Unit Price | Extension |
| 1 | 493-64 | 1100 | SAN++® SAMPLER, RANDOM ACCESS, |
PC Controlled, 100 sampling positions.
Specifications:
• Standard Cup plate Configuration:
- 1 x 50 positions for 3.5 ml or 8.5 ml. sample cups.
- or 1 x 100 positions for 3.5 ml. sample cups. (see option I)
- or dual sample pick-up 2 x 50 positions for 3.5 ml. sample cups. (see option II)
• Single rotary removable sample tray with dustcover
• Sample uptake with single St St sample needle.
• Random access.
• 4 channel build-in rinsing pump for supply of 1 or 2 independent rinsing liquids.
• LED indication for power on/off, busy, error.
• Built-in audiovisual status indication a.o. last sample pick-up indication.
• Requires Skalar FlowAccess® Windows™ software and interface.
• Power consumption: max. 50VA.
• Dimensions (HxDxW) : 22x36x47cm.
• Weight: 6 kg.
| Options: | 1 | EA | $ - 0 | $ - 0 |
| I. 100 sampling positions, requires valve assembly. (21100325) |
II. Dual sample pick-up simultaneously, 2 x 50 sampling positions. Requires second sample needle 1008 or 1017.
III. Alternative cup plate with dustcover for 80 sample positions and 2 separate detachable sections with 5 x 19 ml. positions each for calibration standards, QCS. (21100315) IV. Mixing device for sample stirring during sample pick-up (21100951) Optional Cup plate Configuration:
• 1 x 40 positions for 3.5 ml or 8.5 ml.
sample cups.
• or 1 x 80 positions for 3.5 ml. sample cups. (see option I)
• or dual sample pick-up 2 x 40 positions for 3.5 ml. sample cups. (see option II)
2 493-64 2SAN59000 SAN++® CLASSIC MODULE HOLDER WITH INTEGRATED ELECTRONICS
EXCLUDING PC
Consists of:
• Proportioning pump 2 x 16 channel with 2 x pump deck
• Stainless steel pump rollers 2 x 10
• High precision 24 V DC motor
• Built-in 12 channel high precision air injector with air supply pump, pressure regulator for air segmentation and inlet for supply of external inert segmentation gas
• Module holder with positions for up to five (5) chemistry modules
• Integratable in-line distillation, dialysis and digestion units
• Integrated LCD touchscreen for control of basic analyser functions (pump speed, reactor temperatures etc.)
• Multi-speed pump (off/standby/analyze/rinse) function controlled via integrated touch screen and/or FlowAccess V3 software
• Automatic pump pulsing during instrument downtime for extended pump tube lifetime
| • Five (5) separate glass waste receptacles selectable per chemistry module | 1 | EA | $ - 0 | $ - 0 |
| • Housing in compliance with CE and CSA regulations |
• Compatible with chemistry application modules of former San+® and San++® models
• Compatible with all current Skalar samplers
• Power consumption 700 VA max
• Software FlowAccessV3 communication by TCP/IP
• Connection to all peripherals via integrated CAN BUS hub
• Multi-zone leak detection functionality as standard
• Voltage: 100-120V / 220-240V
• Left or right installation direction
• Dimensions (h x d x w): 335 x 510 x 837 mm, approx.
• Skalar FlowAccess V3 included for full system control and automatic data acquisition & handling 3 PC* PERSONAL COMPUTER, Desktop model Specifications:
• HP EliteDesk 600 G9
• Processor: Intel Core i5-12500, 3.6GHz 4C 65W
• RAM: 16 GB DDR5-4800
• HD: 512 GB SSD
• Win 11 Pro
• Skalar branded logo
• 2nd network connection
• Screen HP ProDisplay P 201, LED, 24””
• Mouse
• A4 printer type Deskjet, Hewlett Packard Excluding:
| • Keyboard | 1 | EA | $ - 0 | $ - 0 | ||||
| 4 | 90004960* | KEYBOARD INTERNATIONAL | 1 | EA | $ - 0 | $ - 0 | ||
| 5 | M293335.4R | MODULE FOR THE ANALYSIS OF CYANIDE (after manual distillation) |
(According to EPA 335.4) Range:1 - 500 μg CN/liter, water Includes:
| Reactor 40°C. | 1 | EA | $ - 0 | $ - 0 | ||||
| 6 | 6433 | FLOW CELL tube shape, 30mm | 1 | EA | $ - 0 | $ - 0 | ||
| 7 | 6547 | FILTER 570 nm | 1 | EA | $ - 0 | $ - 0 | ||
| 8 | M563052 | MODULE FOR THE ANALYSIS OF SILICATE | ||||||
| Range: 0.1 - 10 mg SiO2/liter, water | 1 | EA | $ - 0 | $ - 0 | ||||
| 9 | 6433 | FLOW CELL tube shape, 30mm | 1 | EA | $ - 0 | $ - 0 | ||
| 10 | 6595 | FILTER 810 nm | 1 | EA | $ - 0 | $ - 0 | ||
| 11 | M461353.2 | MODULE FOR THE ANALYSIS OF NITRATE+NITRITE |
according EPA method 353.2 Range: 0.05 - 10 mg N/liter, water Requires:
Predilution step MP1, item 12 in this quotation
| Includes: Cadmium reduction column and switching valve | 1 | EA | $ - 0 | $ - 0 | ||||
| 12 | MP1 | PRE-DILUTION STEP required for the analysis of Nitrate + Nitrite | 1 | EA | $ - 0 | $ - 0 | ||
| 13 | 6433 | FLOW CELL tube shape, 30mm | 1 | EA | $ - 0 | $ - 0 | ||
| 14 | 6537 | FILTER 520 nm | 1 | EA | $ - 0 | $ - 0 | ||
| 15 | M467353.2 | MODULE FOR THE ANALYSIS OF |
NITRITE (according EPA method 353.2)
| Range: 0.02 - 5 mg N/liter in water | 1 | EA | $ - 0 | $ - 0 | ||||
| 16 | 6401 | FLOW CELL with debubbler 10mm 1.8 mm | 1 | EA | $ - 0 | $ - 0 | ||
| 17 | 6537 | FILTER 520 nm | 1 | EA | $ - 0 | $ - 0 | ||
| 18 | 26200904 | SAN++® DUAL CHANNEL DIGITAL PHOTOMETER DETECTOR HEAD |
Specifications:
• Wavelength selection by insert of interference filters. • Wavelengths range 340 – 1100 nm.
• Accommodation for 2 flow cells of 5 up to 50 mm path length each.
• Software controlled automatic baseline and peak height settings.
• Software controlled lamp-switching on/off.
• 20 bits high-resolution absorption recording.
• Detection range up to 6.5 AU.
| • Signal / noise ratio < 0.0003 AU. | 2 | EA | $ - 0 | $ - 0 |
| 19 | KIT | ACCESSORIES, ANALYZER START- UP |
KIT for installation and initial operation.
Consists of pump tubing, sleeves, sampler
| cups, tool kit and spare part kit. (To be specified on request). | 1 | EA | $ - 0 | $ - 0 | ||||
| Freight | 1 | EA | $ - 0 | $ - 0 | ||||
| Estimated Delivery Time: | Total | $ - 0 | ||||||
| NOTE: Quote F.O.B. Destination Freight Prepaid & Included, otherwise show exact delivery cost and terms. Unless stated otherwise, delivery is considered to be 14 days after receipt of order |