ESBD_428078_1749847327862_582-25-08673 Attachment A.pdf
PDF 67 KB Posted
- Attached to
- Replacement Parts State and local contract opportunity
- Solicitation number
- 582-25-08673
- Issued by
- Texas
About this file
This document is Attachment A, Specifications for Repair Parts for Teledyne Air Monitors, issued by the Texas Commission on Environmental Quality (TCEQ). The specification details the required repair parts for maintaining Teledyne air monitoring instruments installed in the TCEQ Air Monitoring Network. The document provides a comprehensive list of 24 specific component types, including valve assemblies, printed circuit boards, photomultiplier tube preamplifiers, pump assemblies, sensor boards, filters, and replacement kits for various Teledyne air monitoring models such as T100, T200, T300, T400, T500, T700, T750, and T800 series.
The specifications are structured to enable precise replacement of critical components when monitoring instruments fail due to extended use. Each listed part includes a specific Teledyne part number or equivalent, ensuring compatibility with different monitoring instrument models. The parts cover a range of functions including valve mechanisms, electrical components, pneumatic sensors, UV lamp drivers, internal pumps, and supplementary accessories like filters and charcoal retainers. The document appears to be part of a procurement process that allows for equivalent parts, providing flexibility in sourcing while maintaining technical specifications for the air monitoring equipment.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| ESBD_428078_1749847286586_RFB 582-25-08673 Fillable Form.pdf | ||
| ESBD_428078_1749847347970_TCEQ RFB Terms and Conditions Final 4-4-2025.pdf | ||
| ESBD_428078_1749847305108_RFB 582-25-08673 Non-Fillable Form.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment A Specifications for Repair Parts for Teledyne Air Monitors
Description: The Texas Commission on Environmental Quality repairs Teledyne air monitoring instruments that have been installed in TCEQ Air Monitoring Network to monitor criteria and other pollutants. When these monitors fail due to extended use, they are returned to the main TCEQ office for maintenance and repair. Numerous parts are required to repair the different models of malfunctioning instruments. These specifications refer to the specific Teledyne parts required for maintenance and repair.
MINIMUM GENERAL SPECIFICATIONS
1. The following components are required for monitor maintenance:
a. Assembly, Prereact valve assembly, for use with T200UP, T200U NOy, and T200U NOx, Teledyne Part Number 024600400 or equivalent
b. Printed Circuit Board, Bench Detector Preamplifier Board Assembly, for use with T750, T750U, T703, T700U, T700, T703U, and T400, Teledyne Part Number 041200000 or equivalent.
c. Photomultiplier tube Preamplifier, SOx, for use in T100, T100H, T101, T102, and T108 Teledyne Part Number 041800400 or equivalent.
d. Photomultiplier tube Preamplifier, NOx ultra, for use in T200U NOx or T200UP, Teledyne Part Number 041800600 or equivalent.
e. PUMP ASSEMBLY WITH 13" LEADS, 12 volts, single head, For T700 and T700U, Teledyne Part Number 047020200 or equivalent.
f. Printed Circuit Board, ultraviolet detector, with OP20, Dual Out, 100, for use with T108, T102, T101, and T100, Teledyne Part Number 050630100 or equivalent.
g. Printed Circuit Board, valve driver, for use with T700U or T700, Teledyne Part Number 054690000 or equivalent.
h. Assembly, Valve with Connection, Volt ampere 59, for use with Teledyne T700U or T700, Teledyne Part Number 055220000 or equivalent.
i. Assembly, valve, volt ampere 59, with diode, 9 inch lead, for use with T100 and T400, Teledyne Part Number 055560100 or equivalent.
j. Assembly, moly valve, volt ampere 59 without diode, 5 inch leads, CN185, for use with T500, T200U Nox/NOy, T500U, Teledyne Part Number 059430200 or equivalent.
k. PRINTED CIRCUIT ASSEMBLY, PNEUMATIC SENSOR BOARD ASSEMBLY, 15PA, 1LPM, (CO/O3) used for T300, T300M, T360, T360M, T400, T802 Teledyne part number 073210400 or equivalent.
l. PRINTED CIRCUIT ASSEMBLY, PNEUMATIC SENSOR BOARD ASSEMBLY, 15A, 15PA, 1LPM, (PA), For T200, T200U, Teledyne Part Number 073210800 or equivalent.
m. Pneumatic Sensor Board assembly (MFC pressures) used for: T700, T700H, T700U, T750, T750U Teledyne part#084210010 or equivalent.
n. Pneumatic sensor board assembly (photometer option) used for: used for T700, T700U, T750, T750U, T703 Teledyne part #084210210 or equivalent.
o. Filter, Disposable Filter Unit, Nylon, 1/4 inch tube, 0.01 micrometer, for use with T100, T200U NOy, T200, T100H, T100U, Teledyne Part Number FL0000003 or equivalent.
p. Assembly & TEST, SPARE PS37, For T700U, T700, T500U, T201, T200U NOy, T200U NOx, T200, T101, T100U, and T100, Teledyne Part # KIT000253 or equivalent.
q. Kit, replacement cooler, for use with T100 and T100U, Teledyne Part Number KIT000095 or equivalent.
r. KIT, UV Lamp Driver, O3 Bench used on: T400, T700, T700U, T703, T703U, 750, 750U Teledyne Part# KIT000290
s. Kit, Pneumatic Sensor Assembly, 15PA, 1 liter per minute, SOx, sealed, for use with T101, T100, and T100U, Teledyne Part Number KIT000369 or equivalent.
t. Internal Pump Assembly, Universal Voltage, 6OC used for: T108, T101, T100, T400, and T102 Teledyne part#077480200 or equivalent.
u. Assembly, Moly guts, Type K, Generation 2, for use with T200U NOy, Teledyne Part Number 047200300
v. Activated Charcoal, 2 bottles at 64 ounces each, for use with T701 and T701H, Teledyne Part Number 005960000
w. Assembly, pump for T640 and T640x, Teledyne Part Number 081410000 or equivalent.
x. Retainer Pad for Charcoal, Large 2 ¼ inch, for use with T701 and T701H, Teledyne Part Number 006900100 or equivalent.
File details come from the government source that posted it. Updated .