This is a technical drawing package from The Texas Department of Criminal Justice (TDCJ) for the fire escape stairway replacement project at the Garza East Unit, Building #634. The drawings include detailed site plans showing the Garza East and Garza West facility layouts, along with specific structural and engineering specifications for the fire escape stairway installation. The drawings detail a straight stair design with top and intermediate landings, measuring 14' - 4-1/2" in height with 23 risers at 7-1/2" each. Technical specifications show bar grating for treads and landing decks, MC12 x 14.3 channel stringers, and stainless steel pipe rails with 1-5/8" O.D. mill finish on both sides.

The drawing set includes foundation details, stairway section views, and connection details between structural elements. Sheet S1 shows foundation plans and sections, Sheet S2 provides stair sections and details, and Sheet S3 contains connection details and additional technical specifications. The drawings are stamped with the Texas state seal and include engineering certification dated 06/24/2024, indicating these are final construction documents ready for contractor bidding and implementation.