ESBD_384094_1733516620630_IFB-25-010 Attachment B - Pioneer specs.pdf
PDF 641 KB Posted
- Attached to
- Trash pumps and proportioning devices
- Solicitation number
- IFB-25-010
- Issued by
- Sterling County, Abilene City, Texas
About this file
This is a technical specification document (Attachment B) for IFB-25-010 detailing requirements for a Pioneer Prime Diesel-Driven Trailer Package model PP44S10L71-D2.9L4. The document provides comprehensive specifications for a trailer-mounted pump system featuring a 4" x 4" pump with a maximum flow of 1,520 gpm, powered by a Deutz D2.9L 4-cylinder diesel engine. The system includes a Pioneer Prime priming system with indefinite run-dry capability, extreme flow technology, and environmentally safe priming features. Key operational specifications include a 75-gallon fuel capacity, operating speeds of 1,000-2,200 rpm, and a total weight of 3,000-3,533 lbs.
The specification sheet includes detailed mechanical dimensions, performance curves, and materials of construction. The pump components are constructed with high-grade materials including CA6NM Stainless Steel impeller, 17-4 PH Stainless Steel shaft, and ductile iron components meeting ASTM A536 65-45-12 standards. Optional additions include solar chargers, corner jacks, float switches, hose racks, pressure gauges, and sound-attenuated enclosure. The document includes detailed performance curves showing operational parameters at various speeds and capacities up to 1,800 GPM.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fuel Capacity 75 gal (284 L) Control Panel LOFA CP900 Operating Speed (Min. / Max.) 1,000 / 2,200 rpm Weight (Dry / Wet) 3,000 lbs / 3,533 lbs Instrument Compatibility High/low level floats, transducers Trailer Brakes Electric
Optional Adders 3-watt solar charger, 10-watt solar charger, corner jacks, float switch, hose racks, pressure gauges, sound-attenuated enclosure
Telemetry Ready Options available
FEATURES AND BENEFITS
PUMP SPECIFICATIONS
• Indefinite run-dry capability
• Extreme flow technology
• Environmentally safe priming system: Pioneer Prime
• Auto-start controls
Size 4" x 4" (100 x 100 mm) Impeller Diameter 10" (254 mm) Max Flow 1,520 gpm (345 m³/h) Max Head 155 feet (47 meters) Solids Size 3" (76 mm) Max. Operating Temp. 200 °F (93 °C) Max. Operating Press. 260 psi (1800 kPa)
ENGINE SPECIFICATIONS
FT4 Engine Type Deutz D2.9L, 4-Cylinder Diesel Displacement 177 cu. in. (2.9 l) Fuel Consumption 2.07 gph (7.83 l/h) @ 1800 rpm Continuous HP 36 HP (27 kW) @ 1800 rpm Peak Intermittent HP Rating 49 HP (36.5 kW)
FT4 Specifics (Def or No Def, DOC, SCR, etc.) DOC
Instrument Panel Oil pressure gauge, voltmeter, hourmeter, tachometer
PIONEER PRIME PRIMING SYSTEM
PACKAGE SPECIFICATIONS
MATERIALS OF CONSTRUCTION
Impeller CA6NM Stainless Steel Shaft 17-4 PH Stainless Steel Wear Ring ASTM A48 Class 40 Gray Iron Suction Cover Ductile Iron ASTM A536 65-45-12 Volute Ductile Iron ASTM A536 65-45-12 Brac-Plate/Bracket Ductile Iron ASTM A536 65-45-12 Mechanical Seal Silicon Carbide rotating and Tungsten Carbide stationary
PARTS KITS
Priming System Mechanically driven diaphragm-style vacuum pump
Air Removal Cap. 50 cfm (.02 cms)
Priming Chamber Positive sealing air separation w/stainless steel components
Discharge Check Valve Swing style; ductile iron w/nitrile disc
Run Dry System Oil-lubricated mech. seal allows pump to run completely dry without damage
Mechanical Seal Kit: 372000109 Upper Vacuum Kit: 374000102 Bearing Frame Kit: 37300107 Lower Vacuum Kit: 374000103 Priming Chamber Assembly: 1060015894
IFB-25-010 ATTACHMENT B
Pioneer Prime Diesel-Driven Trailer Package
PP44S10L71-D2.9L4
44S10-PPI-01-D
M9011 10-22pioneerpump.com | 503.266.4115
MECHANICAL DIMENSIONS
PERFORMANCE CURVE
20 HP
5 HP 7.5 HP 10 HP 15 HP
10 FT. (3.0 M)
6 FT. (1.5 M)
14 FT. (4.3 M) NPSHR
18 FT. (5.5 M)
22 FT. (6.7 M)
25 HP
30 HP
40 HP
MCSF
26 FT. (7.9 M)
50 HP
60 HP
0 50 100 150 200 250 300 350 400
TO
TA
L D
Y N
A M
IC
H
E A
D
CAPACITY
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
P er fo rm an ce s sh ow n fo r c le ar w at er a t S .G
. 1 .0 a nd
0°
F (2
1° C
P
P
P io ne er
P rim e' ) c ur ve s in cl ud e ad di tio na l lo ss es fr om th e ch ec k va lv e an d va cu um p um p.
S
C
S ta nd ar d C en tri fu ga l') p um ps h av e no a dd iti on al lo ss es
GPM
M3/HR
FE
E
T
M E
TE
R
S
1800 RPM
1600 RPM
45%
40%
55%
30% 40%
45%
2200 RPM
55%
50%
50%
800 RPM
2000 RPM
1400 RPM
1200 RPM
1000 RPM
60%
60%
58%
58%
30%
Continuous Operation - No Restrictions.
Limited Operation - Consult Engine Specifications.
Restricted Operation - Not Supported.
File details come from the government source that posted it. Updated .