ESBD_356328_1713201923416_381859-18-24-01-plans.pdf
PDF 4 MB Posted
- Solicitation number
- 381859-18-24-01
- Issued by
- Dallas County, Irving City, Texas
About this file
This document contains structural plans and notes for a Fence & Lighting Installation project at the Dallas Northwest Area Engineer and Maintenance (NW AEM) Facility in Irving, Texas, which is being solicited by the Texas Department of Transportation (TxDOT). The project involves the installation of new perimeter security fencing, a gate with electric operator, electrical infrastructure for perimeter lighting, and electrical service for a future owner-furnished trailer on a 9.6393-acre site. The work is to be performed under a lump sum contract, with the contractor responsible for obtaining all permits, coordinating with utility providers, and ensuring the work complies with applicable codes and regulations. Bids are due by 12:00 PM CT on June 5, 2024, with a public bid reading scheduled for 1:00 PM CT the same day at the TxDOT State Headquarters in Austin, Texas. A mandatory pre-bid meeting is scheduled for April 29, 2024 at 9:00 AM CT at 1424 High Meadows Way in Cedar Hill, Texas, and a mandatory site visit is scheduled for the same date at 11:00 AM CT at the project location.
The estimated cost for the project is $368,000.00, with a bid guarantee or bid bond requirement of $7,000.00. The contract will be awarded by the Texas Transportation Commission, and payment terms include an Early Payment Program option, allowing vendors to determine a discount rate for early payment within 10 business days of invoice acceptance. The solicitation requires the submission of a Historically Underutilized Business (HUB) Subcontracting Plan, which outlines the respondent's intention to subcontract portions of the work and the percentage that will be awarded to HUB vendors.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
04/09/2024
STRUCTURAL NOTES
GENERAL NOTES
1.0 GENERAL
1.1 THIS PROJECT DESIGN IS SITE SPECIFIC AND MAY NOT BE USED FOR
DIFFERENT SITE LOCATIONS.
1.2 THIS PROJECT HAS BEEN DESIGNED AS A PARTIALLY GROUND
SUPPORTED CONCRETE FOUNDATION, AND AS SUCH WILL MOVE WITH THE
SOILS UPON WHICH IT BEARS. THIS DESIGN IS INTENDED TO LIMIT SUCH
MOVEMENT TO WITHIN THE DEFLECTION TOLERANCES SET FORTH IN THE
INTERNATIONAL BUILDING CODE 2021, EDITION IN FORCE AT TIME OF
DESIGN.
1.3 DO NOT SCALE THIS DRAWING. THIS IS A SCHEMATIC PLAN TO BE USED
TO LOCATE AND IDENTIFY STRUCTURAL FOUNDATION ELEMENTS ONLY.
DIMENSIONAL CONTROL IS THE RESPONSIBILITY OF THE BUILDER AND
CONTRACTOR TO FOLLOW THE ARCHITECTURAL, DESIGNER PLANS, OR
EXISTING SITE CONDITIONS. USE THIS PLAN FOR PLACEMENT OF
STRUCTURAL FOUNDATION ELEMENTS ONLY.
1.4 THE BUILDER SHALL VERIFY ALL DIMENSIONS AND SHALL NOTIFY THE
ARCHITECT OR DESIGNER AND THE ENGINEER IN WRITING OF ANY
DISCREPANCY AND FOR DIRECTIONS TO RESOLVE THE DISCREPANCY.
THE ARCHITECTURAL OR DESIGNER PLANS TAKE PRECEDENCE OVER THIS
DRAWING IF ANY NON-STRUCTURAL DIMENSIONAL DISCREPANCY EXISTS.
1.5 THE BUILDER SHALL COORDINATE THIS DRAWING WITH ALL
STRUCTURAL, CIVIL, ELECTRICAL, AND MECHANICAL PLANS FOR ALL
OPENINGS, EMBEDDED ITEMS, DROPS, OFFSETS, SLOPES, ETC. AND SHALL
NOTIFY THE ARCHITECT OR DESIGNER AND THE ENGINEER IN WRITING OF
ANY DISCREPANCY AND FOR DIRECTIONS TO RESOLVE THE DISCREPANCY.
1.6 SEE SITE PLAN, ARCHITECTURAL PLAN, OR DESIGNER PLAN FOR
ACTUAL TOP-OF- FOUNDATION ELEVATION.
1.7 THIS CONSTRUCTION IS OF A MINOR NATURE AND WILL NOT REQUIRE
SPECIAL INSPECTIONS.
1.8 THE DESIGN AND PROVISION OF ALL TEMPORARY SUPPORTS SUCH AS
GUYS, BRACES, FALSEWORK, SUPPORTS AND ANCHORS FOR SAFETY
LINES, CRIBBING, OR ANY OTHER TEMPORARY ELEMENTS REQUIRED FOR
THE EXECUTION OF THE CONTRACT ARE NOT INCLUDED IN THESE
DRAWINGS AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
TEMPORARY SUPPORTS SHALL NOT RESULT IN THE OVERSTRESS OR
DAMAGE OF THE ELEMENTS TO BE BRACED NOR ANY ELEMENTS USED AS
BRACE SUPPORTS
1.9 PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF TXDOT IS
SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK IS
PROCEEDING IN ACCORDANCE WITH THE STRUCTURAL CONTRACT
DOCUMENTS. THIS LIMITED SITE OBSERVATION IS NOT INTENDED TO BE A
CHECK OF THE QUALITY OR QUANTITY OF THE WORK, BUT RATHER A
PERIODIC CHECK IN AN EFFORT TO INFORM THE OWNER AGAINST
DEFECTS AND DEFICIENCIES IN THE WORK OF THE CONTRACTOR.
2.0 DESIGN DATA AND CRITERIA
2.1 THE PROJECT DESIGN UTILIZED GUIDANCE PROVIDED IN THE 2021 IBC.
2.2 DESIGN PI=31, PROPERTY IN IRVING. APPROXIMATE COORDINATES
32.835062, -96.910810. PRESUMPTIVE BEARING CAPACITY 1500PSF
2.3 STRUCTURAL FOUNDATION DESIGN LOADS:
DEAD LOADS:
LIGHT POLES-1500LBS
SELF WEIGHT OF FOUNDATION
LIVE LOAD:N/A
WIND:
BASIC WIND SPEED:105
EXPOSURE CATEGORY:C
RISK CATEGORY:2
ENCLOSURE CLASSIFICATION: OPEN
INTERNAL PRESSURE COEFFICIENT:NA
SNOW=5PSF
RAIN= IRVING, TEXAS
15 MIN 8.06IN/HR
60 MIN 3.65IN/HR
SEISMIC DESIGN PARAMETERS
RISK CATEGORY 2
SEISMIC IMPORTANCE FACTOR 1
SITE CLASS D -ASSUMED
MAPPED SPECTRAL RESPONSE ACCELERATION SS= 0.098 S1=0.054
SEISMIC DESIGN CATEGORY B
3.0 SITE PREPARATION AND DRAINAGE
3.1 EXISTING ASPHALT, VEGETATION AND ANY EXISTING LOOSE MATERIALS
SHALL BE STRIPPED AND REMOVED FROM THE PROPOSED FOUNDATION
FOOTPRINT AREA.
3.2 TREES WITHIN A DISTANCE TO THE FOUNDATION OF ONE TIMES THE
MATURE TREE HEIGHT MAY DAMAGE THE FOUNDATION. EXISTING AND
NEWLY PLANTED TREES WITHIN ONE TIMES THE MATURE TREE HEIGHT TO
THE FOUNDATION PERIMETER ARE AT THE RISK OF BUILDER AND/OR
OWNER AND MUST HAVE A PROPERLY DESIGNED AND PLACED ROOT
SHIELD (ROOT BARRIER), DESIGNED BY AN ARBORIST OR TREE EXPERT, TO
INHIBIT TREE ROOT GROWTH TOWARD AND UNDER THE FOUNDATION.
3.3 VOIDS (HOLES) CREATED AS A RESULT OF DEMOLITION AND REMOVAL
OF EXISTING STRUCTURES, TREES, AND OTHER EXISTING OBJECTS SHALL
BE FILLED WITH WELL COMPACTED SELECT FILL MATERIAL. THIS IS
USUALLY DONE BY LAYERING THE HOLE WITH SELECT FILL MATERIAL
APPLYING WATER AND COMPACTING EACH LAYER, COMPACTING WITH
HEAVY EARTH MOVING EQUIPMENT OR A HEAVY TRUCK. CONTINUE THIS
PROCESS UNTIL THE HOLE IS FILLED.
3.6 THE BUILDER IS RESPONSIBLE FOR CONSTRUCTION OF FINAL SURFACE
DRAINAGE PATTERN TO PREVENT PONDING AND LIMIT SURFACE WATER
INFILTRATION AT THE FOUNDATION PERIMETER. THE ENGINEER IS NOT
RESPONSIBLE FOR FOUNDATION WITH INADEQUATE DRAINAGE AND/OR
GROUND WATER COLLECTION PROXIMATE TO THE FOUNDATION
PERIMETER OR BENEATH THE FOUNDATION.
6.0 FOUNDATION CONSTRUCTION DRILLED SHAFTS
6.1 SHAFT DIAMETERS AND DEPTHS AS INDICATED ARE MINIMUM
ACCEPTABLE SIZES. LARGER SIZES FORMED BY LESS ACCURATE
INSTALLATION MAY REQUIRE ADDITIONAL REINFORCING NOT SHOWN
WHICH SHALL BE DETERMINED BY THE ENGINEER DURING CONSTRUCTION
REVIEW.
6.2 REMOVE FREE WATER FROM HOLES AND ALL OTHER EXCAVATIONS
BEFORE PLACING CONCRETE. CLEAN BOTTOM OF DRILLED HOLE OF
LOOSE SOIL, ROOTS, GRAVEL, AND ALL DEBRIS PRIOR TO PLACING
CONCRETE.
6.3 FORMWORK SHORING SHALL BE DESIGNED IN ACCORDANCE WITH THE
LATEST EDITION OF THE AMERICAN CONCRETE INSTITUTE (ACI) ACI 347,
"STANDARD FOR DESIGN AND PLACEMENT OF CONCRETE FORMWORK",
6.4 ALL CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 302.1R.
6.5 PROPER CURING OF ALL CONCRETE SURFACES SHALL BE PROVIDED BY
THE BUILDER AND IN ACCORDANCE WITH THE LATEST EDITION OF ACI 308,
"STANDARD PRACTICE FOR CURING CONCRETE."
6.6 DO NOT PLACE CONCRETE WHEN TEMPERATURE IS BELOW 40
DEGREES FAHRENHEIT UNLESS COLD WEATHER CONCRETE PROCEDURES
ARE FOLLOWED. CALCIUM CHLORIDE SHALL NOT BE USED. PROVIDE
SPECIAL CARE TO PREVENT HIGH TEMPERATURES DURING HOT WEATHER
CONDITIONS IN FRESH CONCRETE. USE WATER REDUCING SET
RETARDING ADMIXTURES IN SUCH QUANTITIES AS SPECIFICALLY
RECOMMENDED BY THE MANUFACTURER TO ASSURE THE CONCRETE
REMAINS WORKABLE.
6.7 SCHEDULING OF CONCRETE DELIVERY SHALL BE SUCH TO PREVENT
PLACED CONCRETE FROM HARDENING PRIOR TO PLACEMENT OF
ADDITIONAL FRESH CONCRETE. NO HORIZONTAL JOINTS WILL BE
PERMITTED IN THE CONCRETE EXCEPT AS NOTED. THE BUILDER SHALL
CONTACT THE ENGINEER PRIOR TO PLACING ANY CONCRETE IF
CONSTRUCTION JOINTS ARE REQUIRED.
7.0 CONCRETE AND REINFORCING STEEL-DRILLED SHAFTS
7.1 ALL CONCRETE AND REINFORCING STEEL SHALL MEET LATEST EDITION
OF ASTM A615 AND ACI 117 "STANDARD TOLERANCES FOR CONCRETE
CONSTRUCTION AND MATERIALS".
7.2 WHILE SOME SHRINKAGE CRACKING IS TO BE EXPECTED IN THE
CONCRETE, IT HAS BEEN SHOWN TO BE SIGNIFICANTLY REDUCED
THROUGH PROPER CURING PROCEDURES AND PROPER CONTROL OF
ADMIXTURES. ONLY THOSE ADMIXTURES HAVING SPECIFIC WRITTEN
AUTHORIZATION OF THE DESIGN ENGINEER SHALL BE INTRODUCED WITH
THE CONCRETE MIX.
7.3 TESTING SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDER, AND
ANY SUBSTANDARD STRENGTHS SHALL BE REPORTED TO ENGINEER.
7.4 CONCRETE SHALL BE PLACED IN ACCORDANCE WITH LATEST EDITION
OF ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
BUILDINGS".
7.5 CONCRETE COMPRESSIBLE STRENGTH SHALL BE 3000 PSI MINIMUM
STRENGTH AT 28 DAYS.
7.6 CEMENT SHALL BE TYPE 1 (GRAY) PORTLAND. MAXIMUM WATER
CEMENT RATIO SHALL BE 0.5 AND A SLUMP RANGE OF 4 1/2 TO 6 1/2 INCHES
(DRILLED SHAFT). MAX AGGREGATE SIZE SHALL BE 1 1/2INCHES.
CONTRACTOR SHALL SATISFY HIMSELF THAT THE MIX DESIGN IS
ACCEPTABLE FOR ITS INTENDED PURPOSE.
7.7 REINFORCING STEEL SHALL MEET LATEST EDITION OF ASTM A-615,
GRADE 60 DEFORMED BARS. #3 BARS MAY BE GRADE 40.
7.8 WELDED WIRE MESH (WWM) SHALL MEET LATEST EDITION OF ASTM
A-185 OR ASTM A-497. USE FLAT SHEETS ONLY. ALL LAPS TO BE 2 FULL
SQUARES.
7.9 ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED AT 48" O.C. TO
PREVENT VERTICAL AND HORIZONTAL MOVEMENT DURING THE
PLACEMENT OF CONCRETE.
SHAFT DIA.
3" CLR.
3" CLR. CVR.(MIN)
#3 @ 12" O.C.8-#724"
PIER REINFORCING
DIAMETER
SHAFT VERTICAL
BARS
TIES
PIER
DESIGNATION
P1
2-#3 TIES @
3" O.C. BOTTOM
2 - #3 TIES @ 3" O.C. TOP
SEE SCHED.
FOR REINF.
SEE SCHED.
FOR TIE SIZE
T.O. PIER
=2'-6"
B.O. PIER
EL.=10'-0" BELOW FINISHED GRADE
FINISHED SURFACE SEE
SITE LAYOUT (TYP.)
ANCHOR BOLTS TYPES AND GROUT
THICKNESS BY LIGHT POLE PROVIDER.
ANCHOR BOLTS SHALL HAVE MIN. 1'-6"
EMBEDMENT INTO PIER.
NOTE: IF BEDROCK IS ENCOUNTERED
PRIOR TO ACHIEVING THE 10'-0"
DEPTH, CONTRACTOR SHALL
CONTACT ENGINEER FOR DIRECTION
PRIOR TO PROCEEDING
FINISHED GRADE
=0'-0"
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
NOT FOR REGULATORY
APPROVAL, PERMITTING,
OR CONSTRUCTION
SUBMITTAL
/2
/2
:3 :0
A
M C
U s e rs
\A S
T O
N E
\D o w n lo a d s \F
A M
IS
p ro je c ts
\l ig h t p o le b a s e s \S
T R s it e l ig h ti n g .r v t
S0.1
CHECKED BY: BH
ISSUED: FEB 2023
30%
DRAWN BY: AMS
D A
L N
W A
E M
F A
C
IL
IT
Y
F
E N
C E
A N
D L
IG
H
T
IN
G P
P R
O J E
C T
S H
P E
T E
R S
R O
A D
IR
V
IN
G
T E
X A
S
D A
L L
A S
C O
U N
T Y
D A
L L
A S
D
IS
T R
IC
T
P R
O J E
C T
N o
-1
-1
-2
-0
STRUCTURAL LIGHT POLE BASE
04/03/2024
| signed S0.1 str light pole sheet.pdf |
| Sheets |
| S0.1 - STRUCTURAL LIGHT POLE BASE |
File details come from the government source that posted it. Updated .