About this file
This document is an addendum to a contract opportunity issued by the Texas Department of Transportation (TxDOT) for the Fuel Stations, Pharr District project located in San Benito and Falfurrias, Texas. The addendum modifies the original project specifications and drawings dated June 10, 2020, and provides responses to questions identified during the request for information (RFI) period. The project ID is 21-470424537 and the estimated cost is $600,000. The pre-bid meeting is scheduled for April 3, 2024, at 1:30 PM CT, and bids are due on May 7, 2024, at 1:00 PM CT. The addendum clarifies that equipment specification sheets will be added to the bid package and that deviations from the design will not be approved during the bid phase.
The contract opportunity requires a bid bond of $12,000 and the use of a Historically Underutilized Business (HUB) Subcontracting Plan. The project is funded by the Texas Department of Transportation and will be awarded by the Texas Transportation Commission. Bidders are cautioned to carefully review the Standard Conditions document for compliance with all requirements, and the Texas Department of Transportation reserves the right to reject any and all proposals.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NO: 1 - issued by the
LOCATION: 1350 EAST HIGHWAY 77
CITY/ST: SAN BENITO, TEXAS 78586
SITE NO.: 219815
BLDG NO.: N/A
ESTIMATED COST:
BID GUARANTY or BID BOND:
PRE-BID DATE, TIME: APRIL 3, 2024 @ 1:30 PM CT
BID DATE, TIME: MAY 7, 2024 @ 1:00 PM CT
BIDS MUST BE RECEIVED BY: NOON (12:00 PM) FOR 1:00 PM READING
Project by the: TEXAS DEPARTMENT OF TRANSPORTATION
SUPPORT SERVICES DIVISION (SSD), FACILITIES PLANNING & MANAGEMENT
6230 EAST STASSNEY LANE, AUSTIN, TEXAS 78744
ADDENDUM NO. 1 IS ATTACHED WITH THIS NOTIFICATION.
Available to download from: Electronic State Business Daily (ESBD) Use Agency 601 for Requisition Number:
TxDOT Plans Online https://www.txdot.gov/business/letting‐bids/plans‐online.html
TxDOT Facilities Letting https://www.txdot.gov/business/suppliers‐vendors/facilities‐projects‐letting.html
NOTE:
NOTICE TO BIDDERS:
ADDENDUM NO. 1
This Addendum forms a part of the Contract Documents and modifies the original Project Specifications and Drawings dated June 10, 2020.
No changes to COST or TIME.
Also included are responses to questions identified during the RFI period.
Total pages to this Addendum including cover pages: 4 construed that each bidder’s proposal is submitted with full knowledge of all modifications and supplemental data specified herein.
INCOMPLETE PROPOSAL PACKAGE 1 (CONTRACT DOCUMENTS) WILL BE REJECTED
RECEIPT OF THIS ADDENDUM IN PROPOSAL PACKAGE 1 (CONTRACT DOCUMENTS), "ADDENDUM ACKNOWLEDGMENT" SHEET
CAMERON
PHARR
FAILURE TO ACKNOWLEDGE RECEIPT OF AN ADDENDUM WILL RESULT IN THE BID NOT BEING READ.
by this Addendum shall remain in effect as a part of the Contract Documents.
$600,000.00 $12,000.00 http://www.txsmartbuy.com/sp
21-470424537
THIS ADDENDUM SHALL BECOME AN OFFICIAL PART OF THE PLANS AND SPECIFICATIONS AND BIDDERS SHALL ACKNOWLEDGE
Contract Documents, this Addendum shall govern and take precedence. Work not specifically deleted, modified, changed or altered at the same time and incorporated therewith. Where provisions of the following supplementary data differ from those of the original This Addendum shall be considered as part of the Contract Documents for the above mentioned project as though it had been issued
Bidders are hereby notified that they shall make any necessary adjustment(s) in their estimates based on this Addendum. It will be
PROJECT ID #:
COUNTY:
DISTRICT:
OFFICIAL DATE OF ADDENDUM:
FUEL STATIONS, PHARR DISTRICT
TEXAS DEPARTMENT OF TRANSPORTATION
21-470424537
April 15, 2024
San Benito AEM & Falfurrias MNT Sub-Sec. – Fuel Stations Pharr District 21, Cameron & Brooks Counties
Project No: 21-470424537 & 21-470424556
Addendum 1
Date: April 12, 2024 Project Name: Fuel Stations, Pharr District Project Location: San Benito AEM, San Benito, TX
Falfurrias MNT Sub-Section, Falfurrias, TX
ADDENDUM NO. 1
This addendum forms a part of the Contract Documents and modifies the original Project Specifications and Drawings published June 10, 2020, as noted below. Acknowledge receipt of the Addendum in the space provided on the bid form. Failure to do so may subject the Bidder to disqualification.
PRE_BID RFI QUESTIONS:
Question 1: Both sites Plans are missing the Equipment Specifications Pages. The Specs call for Dispenser, TxDOT always use Suction Pumps. Specifications also call for the P52 Valve which is indicative of Suction Pumps. Please confirm if Equipment Specifications are available?
Answer 1: Yes, Equipment Sheets will be added to the Set and issued in Addendum 1.
Question 2: Based on San Benito AEM Drawing EF1.1 Keyed Note 2 Stating to feed new FE
Panel, from the 30A 2 Pole Breaker in Panel “21-00355”, it was identified this panel does not exist in the Maintenance Shop Building, but we have identified a Power Panel that can be utilized in the Adjacent Building, which we are proposing to utilize as the Power Panel to feed the new FE Panel, which we are also requesting to move closer to the Adjacent Building. Trench underground to the Maintenance Shop Building then run ATG and Fiberoptic Conduits on the Exterior Building to the ATG Console located in office, and the Voice Data Room at other end of building.
Please advise if Acceptable? Photos below show detail of request. Photos were provided to SSD Contracting.
Answer 2: No. Deviations from or changes to the Design won’t be approved during the Bid
Phase. Contractors should Bid the Set as issued, and any deviations or changes will be addressed during Construction Phase with the Successful Bidder.
Additionally, it has been confirmed that Panel “21-00355” does exist in the location specified. The 30A 2-pole breaker does need to be added as per Bid Plan Set.
REVISIONS ON THE PLANS:
Cover Sheets
ITEM 1 Added Sheet FS2.1 to San Benito Drawing Set.
ITEM 2 Added Sheet FS2.1 to Falfurrias Drawing Set.
File details come from the government source that posted it. Updated .