AMSC N/A FSC 6015
METRIC
MIL-PRF-85045/18C
17 June 2014
SUPERSEDING
MIL-PRF-85045/18B
16 September 1999
PERFORMANCE SPECIFICATION SHEET
CABLE, FIBER OPTIC, FOUR FIBERS, ENHANCED PERFORMANCE, CABLE CONFIGURATION TYPE 2
(OFCC), APPLICATION B (SHIPBOARD), CABLE CLASS SM AND MM
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-PRF-85045.
CLASSIFICATION:
Fiber optic cable configuration type: 2 (OFCC)
Fiber optic cable class: MM (graded-index, glass core and glass cladding, multimode)
SM (dispersion-unshifted, glass core and glass cladding, single-mode)
DESIGN AND CONSTRUCTION:
Fiber: Class MM fibers shall be in accordance with MIL-PRF-49291/6.
Class SM fibers shall be in accordance with MIL-PRF-49291/7.
Buffer diameter: 900±50 µm
OFCC: Dimensions and configuration: See figure 1.
FIGURE 1. Optical fiber cable component.
Mass per unit length: <15 kg/km
Short-term minimum bend diameter: Eight times the OFCC outer diameter.
Source: https://assist.dla.mil -- Downloaded: 2014-08-13T13:45Z Check the source to verify that this is the current version before use.
Long-term minimum bend diameter: Sixteen times the OFCC outer diameter.
Tensile loading: >270 N
Dynamic bend tensile load: 90 N minimum
Jacket material: The OFCC jacket shall be composed of a low halogen, low smoke, low toxicity polymer material.
Finished cable:
Dimensions and configuration: See figure 2. Four OFCC units shall be helically laid over the central member with a maximum lay of 25 cm. The minimum outer jacket thickness shall be not less than 1.0 mm (establishes compatibility with termination and penetration devices).
NOTE:
1. OFCC – Optical fiber cable component
FIGURE 2. Four-OFCC fiber optic cable.
Number of fibers: 4 (one per OFCC)
Concentricity: >0.8
Mass per unit length: <100 kg/km
Jacket material: The overall jacket shall be composed of a low halogen, low smoke, low toxicity polymer material.
Short-term minimum bend diameter: Eight times the cable outer diameter. (The short-term minimum bend diameter is to be used in all environmental and mechanical tests which specify a cable minimum bend diameter.)
Long-term minimum bend diameter: Sixteen times the cable outer diameter.
Minimum continuous length: The minimum continuous length of all cables shall be not less than 0.5 km. If lengths less than 0.5 km are specified in the purchase order, a conformance inspection shall be performed on test specimens not less than 0.5 km in length from which the purchase order lengths are cut.
Cable jacket color: Shall be black or blue.
PERFORMANCE REQUIREMENTS:
Optical properties:
Maximum attenuation rate: 4.5 dB/km at 850±20 nm, 2.0 dB/km 1300±20 nm for Class MM fiber.
1.5 dB/km at 1310±20 nm and 1550±20 nm for Class SM fiber.
For cables with radiation cross-linked jackets, the change in attenuation rate measurement may be made up to
30 days after cross-linking of the cable jacket.
Bandwidth: Fiber with a minimum bandwidth of 500 MHz-km at 1300 nm shall be used (multimode cables only). Bandwidth is not specified at 850 nm.
Change in optical transmittance: Measurements shall be made at 1300±20 nm.
Mechanical properties:
Tensile loading and elongation: Applicable, tensile loading >1875 N.
Low temperature flexibility: The exposure temperature shall be -40 °C.
Cyclic flexing: 500 cycles at 25±2 °C and 100 cycles at -28±2 °C. Change in optical transmittance measurements are to be made every 100 cycles for the 500-cycle exposure and every 25 cycles for the 100-cycle exposure. Each change in optical transmittance measurement shall be performed with the test specimen in the same position in the test cycle. The cycling may be halted to perform the change in optical transmittance measurement.
Cable twist-bending: 500 cycles at 25±2 °C and 100 cycles at -28±2 °C. Change in optical transmittance measurements are to be made every 100 cycles for the 500-cycle exposure and every 25 cycles for the 100-cycle exposure. Each change in optical transmittance measurement shall be performed with the test specimen in the same position in the test cycle. The cycling may be halted to perform the change in optical transmittance measurement.
Impact: 50 cycles at 25±2 °C and 20 cycles at -40±2 °C. Upon final visual examination at all tested temperatures, there shall be no jacket damage such as splitting or cracking.
Hosing: Both low pressure and hydrostatic pressure are applicable.
Hydrostatic: 7.7 MPa for M85045/18-01P and M85045/18-02P.
Cable scraping resistance: 750 cycles
Cable-to-cable abrasion: 500 cycles
Environmental properties:
Temperature range:
Operating: -28 to 65 °C
Nonoperating: -40 to 70 °C
Storage: -40 to 70 °C
Temperature cycling: Change in optical transmittance measurements may be made periodically. At a minimum, one optical transmittance measurement shall be made over a period of 1 hour at the end of each temperature plateau.
Temperature humidity cycling: Change in optical transmittance measurements may be made periodically. At a minimum, one optical transmittance measurement shall be made at the end of each temperature plateau.
Temperature life (life aging): Applicable, except that the jacket material shall be tested at 175 °C for 4 hours.
Fluid immersion: Exposure to automobile gasoline and tap water are not required and the following test temperatures shall be used for the fluids indicated: fuel oil (98 to 100 °C), turbine fuel (48 to 50 °C), and lubricating oil (98 to 100 °C).
Chemical properties:
Halogen content: <0.2 percent
Cross-link verification: This test is applicable for cables with cross-linked jackets only. The test shall be conducted in accordance with ICEA standard T-28-562 and run at 200 °C. The test shall be in the qualification test sequence using a specimen cut from the sample used in the thermal shock test and in the Group III testing of the
Group C conformance test sequence. The hot creep shall not exceed 100 percent, and the hot creep set shall not exceed 10 percent.
Part or identifying number (PIN) (see table I):
M85045/18-01P (Multimode)
M85045/18-02P (Single-mode)
“P” designates 7.7 Mpa hydrostatic pressure proof cable.
TABLE I. Supersession data.
PIN Superseding
M85045/18-01P M85045/15-01P
M85045/18-01
M85045/18-01N
M85045/18-01T
M85045/18-02P M85045/15-02P
M85045/18-02
M85045/18-02N
M85045/18-02T
Qualification and conformance inspection: See table II.
TABLE II. Qualification and conformance inspection.
Group Qualification inspection
Requirement paragraph
Test paragraph Cable length
1/ 2/
Conformance inspection
I Visual and mechanical inspection
3.4, 3.9, 3.10 4.7.2 3 samples, 0.5 km each 3/
A
Attenuation rate 3.5.1 4.7.4.1 3 samples, 0.5 km each 4/
A
II Crosstalk 3.5.3 4.7.4.3 3 samples, 0.5 km each 4/
Electromagnetic effects
3.7.16 4.7.6.16 1 specimen, 6 m 4/
TABLE II. Qualification and conformance inspection – Continued.
Qualification inspection
Requirement paragraph
Test paragraph
III Temperature cycling
3.7.1 5/
2 samples, 0.5 km each 4/
(1 on reel, 1 off)
C
Temperature humidity cycling
3.7.3 4.7.6.3 2 samples, 0.5 km each 6/
C
Storage temperature
3.7.4 4.7.6.4 2 samples, 0.5 km each 6/
Low temperature flexibility (cold bend)
3.6.3 4.7.5.3 2 specimens, 8 m each 7/
B
Cyclic flexing 3.6.4 4.7.5.4 6 specimens, 5 m each 8/
(2 specimens at each temp)
Crush 3.6.5 4.7.5.5 2 specimens, 5 m each 7/
Cable twist-bend 3.6.6 4.7.5.6 6 specimens, 5 m each 8/
(3 specimens at each temp)
Impact 3.6.8 4.7.5.8 2 specimens, 5 m each 6/
C
Temperature life
(life aging)
5/ 5/ 2 specimens, 300 m each
7/ C
Tensile loading and elongation
3.6.1 4.7.5.1 2 specimens, 150 m each 9/
C
Operating tensile loading
3.6.1.1 4.7.5.1.1 2 specimens, 150 m each 10/
C
Fungus resistance 3.8.4 4.8.4 2 specimens, 0.5 m each 7/
Cable element removability
3.6.18 4.7.5.18 2 specimens, 0.5 m each 7/
C
IV Thermal shock 3.7.2 4.7.6.2 1 specimen, 0.49 km each 4/
(on reel)
Weathering 3.7.8 4.7.6.8 1 specimen, 2 m 11/ and 3 material samples 12/
Fluid immersion 3.7.9 4.7.6.9 1 specimen, 2 m 11/ and 3 material samples 12/ for each specified fluid
C
Paint susceptibility
3.7.15 4.7.6.15 2 specimens, 2 m 13/
Jacket self-adhesion or blocking
3.7.11 4.7.6.11 1 specimen, 30 m 11/
Shock 3.7.13 4.7.6.13 1 specimen, 30 m 11/
Dynamic bend 3.6.2 4.7.5.2 1 specimen, 150 m 14/
B
Hosing: low pressure
3.6.12.1 4.7.5.12.1 1 specimen, 1.5 m 11/
C
Hosing:
hydrostatic
3.6.12.2 4.7.5.12.2 1 specimen, 2 m 11/
C
Qualification inspection
Requirement paragraph
Test paragraph
Radial compression (for application B only)
3.6.7 4.7.5.7 1 specimen, 10 m 11/
Corner bend 3.6.9 4.7.5.9 2 specimens, 5 m 13/
OFCC kink 5/ 5/
2 specimens, 1 m 13/
Cross-link verification
5/ 5/ 2 specimens, 1 m
13/ C
V Dripping 3.6.13 4.7.5.13 1 specimen, 30 cm 11/
Cable jacket tear strength
3.6.14 4.7.5.14 5 flat extruded jacket material strips 15/
Cable jacket material tensile strength and elongation
3.6.15 4.7.5.15 5 specimens 16/
Cable abrasion resistance
3.6.16 4.7.5.16 4 specimens, 2 m 17/
C
Cable shrinkage 3.6.17 4.7.5.17 3 specimens, 0.5 m 13/
C
Durability of identification
3.6.19 4.7.5.19 3 specimens, 2 m each 13/
Flame extinguishing and smoke generation
3.7.12.2 4.7.6.12.2 1 specimen, 50 m 11/
C
Water absorption 3.7.14 4.7.6.14 2 specimens, extruded jacket material strips 16/
VI Acid gas generation
3.8.1 4.8.1 1 specimen, 1 m 18/
C
Halogen content 3.8.2 4.8.2 1 specimen, 1 m 18/
Toxicity index 3.8.3 4.8.3 1 specimen, 1 m 18/
C
Smoke index 3.8.5 4.8.6 1 specimen, 1 m 18/
C
NOTES:
1/
Tolerance on 0.5-km length is ±5 percent, provided that results are normalized to 1 km.
2/
Tolerance on shorter lengths is ±5 percent.
3/
The visual and mechanical inspection shall only be conducted on a 2-m section of each sample.
4/
The same samples as used in the visual and mechanical inspection shall be used.
5/
As stated under the applicable tests in this specification sheet.
6/
The same samples as used in the temperature cycling test shall be used.
7/
A specimen cut from each sample used in the temperature cycling test shall be used.
8/
Three specimens cut from each sample used in the temperature cycling test shall be used.
9/
A specimen cut from each specimen used in the temperature life test shall be used.
10/
The same specimen as used in the tensile loading and elongation test shall be used.
11/
A specimen cut from the specimen used in the thermal shock test shall be used.
12/
Three flat extruded jacket material strips as specified in 4.7.5.15 shall be used in this test.
13/
Specimens cut from the specimen used in the thermal shock test shall be used.
14/
A specimen cut from the specimen used in the thermal shock test or one of the specimens used in the tensile loading and elongation test shall be used.
15/
Flat extruded jacket material strips (i.e., strips of flat extruded material with the same composition of the cable jacket and of sufficient dimensions in which dumbbells can be cut) prepared as specified in 4.7.5.14 cited method and obtained from flat extruded material that underwent the thermal shock test shall be used.
16/
Flat extruded jacket material as specified in 4.7.5.15 shall be used in this test.
17/
Specimen cut from the specimen used in the thermal shock test shall be used. Two specimens shall be used for scraping abrasion, and two specimens shall be used in the cable-to-cable abrasion testing.
18/
A specimen cut from one of the samples used in the temperature cycling test or specimen used in the thermal shock test shall be used.
Manufacturers who produce products for both MIL-PRF-85045/17 and this specification sheet, who are qualified under M85045/17-01, and pass the tests and inspections specified in table III are qualified under this specification sheet for M85045/17-01. This qualification by similarity is applicable if the same materials are used in the previously qualified MIL-PRF-85045/17 cable and the cable under test. Testing may be performed on a single length of cable, with a minimum length of 0.5 km.
TABLE III. Qualification and conformance by similarity to M85045/17.
Group Inspection Qualification inspection 1/
Conformance inspection 2/
I Visual and mechanical X A
Attenuation rate X A
III Low temperature flexibility (cold bend) X B
Impact (low temperature only) X C
IV Hosing: low pressure X C
Cable abrasion resistance X C
V Flame extinguishing and smoke generation
X C
TABLE III. Qualification and conformance by similarity to M85045/17 – Continued.
NOTES:
1/
Where manufacturers are qualified for M85045/17-01 and are pursuing qualification for M85045/18-01.
2/
Where manufacturers are qualified for M85045/17-01 and M85045/18-01 and have passed the full conformance inspection (A, B, and C) for M85045/17-01, a partial conformance inspection as specified in table II is permitted for M85045/18-01.
Manufacturers who are qualified under this specification sheet for multimode fiber cable, M85045/18-01, and whose single-mode fiber cable passes the tests and inspections specified in table IV are qualified under this specification sheet for single-mode fiber cable (M85045/18-02). This qualification by similarity is applicable if the only difference between the previously qualified cable and the cable under test is that the optical fiber has been changed from a multimode fiber to a single-mode fiber. Testing may be performed on either one or two lengths of cable, each with a minimum length of 0.5 km. Test order must be observed up to and including the storage temperature test. If only one cable length is used, the thermal shock test shall be performed after the storage temperature test.
TABLE IV. Qualification and conformance by similarity (fiber).
Group Inspection Qualification inspection
M85045/18-02 1/
Conformance inspection
M85045/18-02 2/
I Visual and mechanical X A
Attenuation rate X A
III Temperature cycling X C
Temperature humidity cycling X C
Storage temperature X --
Cyclic flexing X --
Crush X --
Cable twist-bending X C
Impact (low temperature only) X C
Tensile loading and elongation X C
Operating tensile loading X C
IV Thermal shock X --
Dynamic bend X B
NOTES:
1/
Where manufacturers are qualified for M85045/18-01 and are pursuing qualification for M85045/18-02.
2/
Where manufacturers are qualified for M85045/18-01 and M85045/18-02 and have passed the full conformance inspection (A, B, and C) for M85045/18-01, a partial conformance inspection as specified in table III is permitted for M85045/18-02.
Manufacturers who are qualified for M85045/17-01, M85045/17-02, M85045/18-01, and M85045/18-02 and have passed the full conformance inspection (A, B, and C) for M85045/17-01 and partial conformance inspection as specified in table II for M85045/18-01, are considered conforming under this specification sheet for single-mode fiber cable M85045/18-02.
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.
Custodians: Preparing activity:
Army – CR Navy – SH
Navy – SH (Project 6015-2012-015)
Air Force – 85
NASA – NA