Eng. drawing 42-9803_REVA2.pdf
PDF 563 KB Posted
- Solicitation number
- RFP 751 260000002186 2
- Issued by
- Washtenaw County, Brooklyn Village, Michigan
About this file
This is an engineering drawing document for the Michigan Department of Transportation related to the Cadillac Rest Area Digital Sign Replacement project. The drawing, designated as 42-9803_REVA2, provides technical specifications and design details for the digital sign installation at the Cadillac rest area facility. The document serves as a supporting exhibit for the state and local contract opportunity and includes detailed engineering plans necessary for contractors to understand the physical requirements, dimensions, installation points, and technical specifications of the digital sign replacement project. The drawing appears to be a revised version (Revision A2) of the original engineering plan and would be essential reference material for all bidders preparing proposals for this project.
The engineering drawing establishes the technical baseline and construction requirements that all interested contractors must follow when submitting bids and executing work on the Cadillac Rest Area Digital Sign Replacement project. This document ensures standardization across all proposals and provides clarity on the scope of work, allowing contractors to accurately estimate costs, materials, labor requirements, and project timelines based on the specified engineering standards and design parameters outlined in the drawing.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Specifications For Cadillac Rest Area Electronic Sign.docx | DOCX document | |
| Wexford County Prevailing Wages.pdf | ||
| CRA Fire Danger Sign Location Map.docx | DOCX document | |
| RFP 26-2186 - Cadillac Electronic SIgn.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(102)
(REF-37)
DEPTH PER CODE
(68)
(REF-24) CONDUIT
DEPTH PER CODE
1-1/2 GAP
(+/- 1/2)
4(+/-1)
OVERHANG
FOOTING L.-(REF-102)
SIGN WIDTH + 52"
(REF-90) UPPER CONC. LNG.
(WITH STONE ON)
SIGN WIDTH + 40"**
UPPER CONC.
(W/ STONE ON)
STONE DEPTH
TBD (EST. 4)
FOOTING W.
2 OVERHANG
2 OVERHANG
UPPER CONC.
TBD (REF- 82)
UPPER CONC.
TBD (REF-16)
CAP LENGTH
(REF-94)
CAP
(REF-28)
REF-13
TUBE CENTER
REF-33
REF-80
POST HEIGHT
(REF-74)
POST HEIGHT
(REF-51-1/2)
4(+/-1)
3 TUBE HT- MIN.
2 OVERHANG
TO STONE
ITEM PART NO. DWG DESCRIPTION QTY
1 28" W x 68" H SMOKEY SIGN, AL SHEET W/ STICKER 1
2 ANGLE 2" x 2" ANGLE, STEEL (1/8" min) or AL (3/16 min) 2
3 CAP, CONCRETE CAP, 4" W 2% SLOPE(DRAIN) AND 2" OVERHANG ALL SIDES 1
4 CONCRETE-3000psi FOOTING & BASE (EST. 105 CU-FT) 1
5 CONDUIT, 3/4" ID RIGID, LENGTH AS NEEDED 1
6 ENCLOSURE JUNCTION BOX, 4 X 4 (OR LARGER), NEMA 4 1
7 POST, WOOD TREATED WOOD, 4 x 6 by 8 FT LONG 3
8 REBAR REBAR, STEEL # 4; AS NEEDED 5
9 SIGN, ELECTR ELECTRONIC SIGN, 44" H x 50" W (110 lbs.) 1
10 STONE - DECORE OWENS C. VANEER CSV2084; EARTH RIVER ROCK, OR APPROVED 1
11 TAMP RESIST. SCREW, WOOD, PLATED/EXTERIOR 1/4" X 2"L 3
12 TS-06GG36 SCREW, HEX HEAD CAP 3/8-16UN X 4 1/2 GR 5 PLTD 3
13 TS-06GP B NUT, HEX 3/8-16UN GRADE 5 PLATED 3
14 TUBE RECT.-STRUCT STEEL,RECT. TUBE- 6x4 by 7 ga(3/16") APPROX. 60" L 3
15 WOOD SIGN SIGN - PREVENT FOREST FIRES , 6" H x 96" L -APPROX. 1
SIGN,SMOKEY PREVENT W CONCR, 1 SIDED 42-980314-1
KAJ
KAJ
Jun-10-25
0.021
(ITEM# 7) 4x6 PRESS.
TREATED WOOD POSTS,
BOLTED INSIDE STEEL
TUBES (ITEM# 14)
WITH ITEMS#12,13.
TOP VIEW-
REPRESENTATION WITH 50"WIDE SIGN AND 4" DEEP STONE/VANEER
A1 KJ 05/25 INTITIAL RELEASE
A2 KJ 06/25 FIX SIGN SIZE; LENGTH DIMENSION +40 WAS +38"
NOTE: ALL DIMENSIONS GIVEN ARE SUGGESTED FOR
MI-DNR/SMOKEY SIGN STANDARDIZATION AND MUST NOT
SUPERSEDE ANY BUILDING CODE, ZONING, OR
LOCAL REQUIRMENTS.
PART NO: 42-9803
EST WT: LBS
SCALE 0.047
APPROX.
GRADE
(ITEM# 10) OWENS CORNING
"CULTURED STONE VENEER"
CSV2084 EARTH RIVER ROCK OR
APPROVED EQUIV. ALL AROUND
(4 SIDES) UPPER CONCRETE.
ADD CENTER DESIGN (BEAR PAW
PRINT) PER SPEC ON UPPER
CONCRETE W/ STONES.
(ITEM# 9) E.SIGN MOUNTED ON
TWO POSTS (ITEM# 7) WITH TWO
CROSSMEMBERS(ITEM# 2)PROPERLY
ATTACHED PER WEIGHT & REQUIREMENTS.
NOTE: RECT.TUBE SPACING AND POST
HEIGHT TO ACCOMODATE SIGN MOUNTING
REQUIREMENTS.
(ITEM#1) QTY 1-SMOKEY BEAR SIGN
DIMENSIONS: 28" WIDE X 68" HIGH
MOUNT ON WOOD POST (ITEM #7)
WITH 1/4" SCREWS W/TAMPER
RESIST.HEADS(ITEM#11; QTY 3 MIN.)
(ITEM# 15)PREVENT
F.FIRES SIGN CENTERED
TO UPPER CONCRETE.
ATTACH WITH 1/4"
TAMPER RESIST. SCREWS
(ITEM#11; QTY 3 MIN).
(ITEM # 3) CONCRETE CAP
4" TALL W/
2% CROWN TO DRAIN &
2" OVERHANG ALL SIDES
AFTER ADDING STONE/VANEER
(ITEM# 14) RECTAGLE TUBES
STRUCT. GRADE- STEEL4x6,3/16" WALL,x 60"L. FILL WITH DRAIN
STONE /AGGREGATE BELOW POSTS
(ITEM# 7).
(ITEM# 4)
3000 PSI CONCRETE
FOOTING AND UPPER
PORTION
(ITEM #8) STEEL
REBAR(#4) TYING UPPER
CONCRETE AND STEEL
TUBES SECURLY TO
FOOTING (AS REQ.)
(ITEMS# 5, 6) ELECTRICAL CONDUIT
AND JUNCT.BOX (with OUTLETS, SWITCH, CONNECTORS, ETC.) TO WIRING SPEC.
AND ALL APPLICABLE CODES.
(ITEM#2) ANGLES
ATTACHED TO POST
(ITEM #7) AS
NECESSARY FOR E SIGN
WEIGHT AND MOUNTING
APPROX.
GRADE
TUBE (ITEM# 14)TO BE OPEN
ON BOTTOM FOR DRAINAGE
SEE DETAIL A
(ITEMS#5,6)ENCLOSURE,
OUTLETS, SWITCHES,
MOUNT BETWEEN POSTS
HEIGHT AS NEEDED
DETAIL A
SCALE 0.125
DRILL ⌀7/16 THRU
ITEMS# 7,14 FOR
ATTACHING BOLT &
NUT (ITEMS# 12,13)
x3 PLCS
STD. TOL.
DECIMAL:
1 PLACE + - 0.05
2 PLACE + - 0.01
3 PLACE + - 0.005
ANGULAR:
+ - 1 DEG. N0. BY DATE REVISION
P.O. BOX 68 ROSCOMMON, MICHIGAN 48653
TITLE:PROJECT NO.:
SCALE:
DWG.
NO.
DESIGNED:
FOREST, MINERAL AND
FIRE MANAGEMENT
DATE:
DRAWN:
APPROVED:
FOREST FIRE EXPERIMENT STATION
D
SIZE:
FRACTIONAL:
0 TO 6 IN + - 1/32
6 IN AND UP + - 1/16
| Sheet 1 |
| Views |
| new_view_2 |
| right_3 |
| top_11 |
| right_12 |
| A |
File details come from the government source that posted it. Updated .