This document is a Sources Sought announcement from the Naval Sea Systems Command (NAVSEA) for the USS NEW YORK (LPD 21) FY25 Selected Restricted Availability (SRA). The Navy is conducting market research to determine industry capability and interest in performing pier-side maintenance, repair, and alterations on the USS NEW YORK during the anticipated availability period of 09/01/2025 - 10/09/2026. The anticipated solicitation release date is around 10/21/2024.
The document provides details on the ship's particulars, facility requirements, and anticipated maintenance and modernization work across multiple trades and systems. NAVSEA is especially focused on determining small business capability and interest. Responses are requested by 4PM Local Time on 08/13/2024, and should include company information, past performance, and capability to meet the requirements outlined in the document. The anticipated contract type is firm-fixed price.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Enclosure (1) | Page i
Enclosure (1): Outline of some of the work anticipated to be completed under the expected USS
NEW YORK (LPD 21) FY25 SRA
A. General
a. Competition Area: Coast Wide – East & Gulf Coast
b. Rough Estimate Man-Days (including scope for Temporary Services):
i. Maintenance ~ 65,000
ii. Modernization ~ 5,000
a. Ship Particulars:
i. Length: 684 ft (overall); 661 ft (waterline)
ii. Beam: 105 ft (extreme); 97 ft (waterline)
iii. Draft: 23 ft
iv. Displacement: 24,900 tons (full)
v. Mean Navigable Water depth draft: > 23ft
vi. Air Draft: 157.65ft
vii. Class and type: San Antonio-class amphibious transport dock
b. Facility Particulars:
i. Pier Length: > 684 ft
ii. Electrical: 8000 amps/ 20 Cables /450 volts, 60 hz, 3 ph (UFC 4-150-02 table C-
7)
iii. Potable Water: 9500 GPD (UFC 4-150-02 Table C-4)
iv. Sea Water: 1250 GPM (UFC 4-150-02 Table C-3), 150 PSI measured at the most remote outlet (UFC 4-150-02, Para 3-3.2.1) for firefighting water
v. Sewage: Ability to accommodate and dispose of 10,000 GPD of effluent and
10,000 GPD of waste water
vi. Mean Pier Water depth draft: >33 ft
B. The Availability’s modernization scope will include significant amount of work across multiple trades and spaces. If the Government identifies a requirement, issues a solicitation, and awards a contract, the awarded contractor must be able to provide an integrated production schedule that incorporates anticipated Alteration Installation Teams (AIT), 3rd Party contractors, and Government workload, as well as management of Long Lead Time Material (LLTM) Procurement. Key trades & efforts would include: Structural welding, piping, electrical and ventilation work. Both the Master Ship Repair (MSR) and AIT would execute the structural/Industrial work. Further direction would be provided in the work specifications to define the work split. Some of the anticipated major modernization work is listed below:
AER 83290 D GAYLORD HOOD BOOSTER HEATER MOD
AER 98107 D AHSS TECH REFRESH REPLACEMENT
RME 96896 AN/WSN-7 (V)1, (V)2 REMOVAL OF UNUSED
RME 99401 AN/WSN-7 REMOVAL OF UNUSED/SPARE NTDS
SA 81157 K 08 AUXILIARY SEAWATER SYSTEM
SA 81157 K 09 AUXILIARY SEAWATER SYSTEM
SA 81157 K 10 AUXILIARY SEAWATER SYSTEM
SA 81157 K 11 AUXILIARY SEAWATER SYSTEM
SA 81157 K 12 AUXILIARY SEAWATER SYSTEM
SA 81415 K SSDG SEAWATER PIPING UPGRADE
SA 82249 K LPD 17 CLASS UPS REDUCTION
SA 82441 K WDCM GROUPS 5 & 8 CROSS CONNEC
SA 82520 K IHFA STAND-OFF MOD TO LWCA CON
Enclosure (1) | Page ii
SA 84704 K DISCON SW FOR WR GALLEY
SA 84809 K WELL DECK BRIDGE CRANE EYEBOLT
SA 84960 K LPD 17 CLASS V-LINES INCREASE
SA 86222 K NGF BACKFIT PHASE I
SA 86344 K HM&E NETWORK RING IMPLEMENTATION
SA 86554 K LPD17 STERN GATE EMERGENCY RIG
SA 86669 K CIDS (23TV) UPGRADE TO V5.1
SA 87303 K HHD CONTROL SYSTEM UPGRADE
SA 87359 D MOD TO LPD17 WELDING FUME EXH SYS
SA 87447 K INSTALLATION OF MORIAH WIND SY
SA 87889 K SCULLERY RE-DESIGN
SA 88024 D DRAIN FUNNELS FOR F/O VENT AND SAMPLE
SA 88062 K 1MC RE-POWER
SA 88217 D WATERTIGHT DOOR FOR PILOT BOARDING STATION
SA 88565 D JP5 FUEL SIGHT GLASS DRAIN MOD
SA 89408 K WATERTIGHT HATCH CORROSION ISS
SA 90228 D REPLACE OBSOLETE CONTROL PANEL
SA 90486 D CHILLED WATER TOTS VALVE INSTALL
SA 90511 D REPLACE 3 WAY FUEL OIL VALVE
SA 90641 K DEL STR GEAR TEMP SW
SA 91078 K PILOT BOARDING STATION VENTILATION
SA 91515 K VEHICLE STOWAGE AREA SPKRS
SA 91525 K 4JG1 SOUND POWERED MODIFICATION
SA 91633 D FIREMAIN SYSTEM CORD MOD
SA 91993 K SECONDARY ACCESS FOR HELO WORK
SA 92014 K ICOP FULL INFRAS USMC TRANSMITTER
SA 92017 K PREVENTION OF FROZEN DRAIN LINE
SA 92028 K CPS FAN ROOM DECK DRAIN AND FL
SA 92168 K PROVIDE SMALL BOAT FENDER STOW
SA 92223 K NAB TROOP RIFLE STOWAGE
SA 92418 D LPD17-27 VCHT SYSTEM EJECTOR
SA 92516 D LPD CHEMTRON HFP REPLACEMENT
SA 92525 K MF-TDMA MODEM SUPPORT
SA 92735 K NDDS SUSTAINMENT AND OBSOLESCE
SA 92737 K NAVIGATION CRITICAL DISTRIBUTI
SA 92738 K NDDS NAVIGATION DISPLAY UPGRAD
SA 92881 K NMT MODEM SPIRAL 1
SA 93171 D FLIGHT DECK WHEEL STOP
SA 93372 D LPD BOB JETTISON RACK MOD
SA 93501 K 00 BFTT FST AT-SEA CONNECTIVITY
SA 93584 K AIS V1 CYBER HARDENING
SA 94717 K USMC TIER 2 EMBARKABLE SERVERS
SA 94906 K INSTALL LI-ION BATTERY STORAGE
SA 95000 D COMBI-OVEN GAYLORD HOOD REPLACEMENT
SA 95013 D LPD 17 CLASS HANGER BAY LIGHTING
SA 95124 D RELOCATE COMMS CENTER
SA 95138 D SIDE PORT DOOR DOGGING CYLINDER
SA 95214 D FLT DECK SAFETY NET MOD (MSA)
SA 95228 K LPD HM&E CONDITION SYSTEM 2.0
SA 95397 D MK 46 MOD 02 GUNS BARBETTE DRAIN
SA 95656 K CANES HW3
Enclosure (1) | Page iii
SA 95788 D 400 HZ SSFC DISTRO UPGRADE
SA 96491 K X5J SOUND POWERED COMMUNICATION
SA 96492 K P25 HYDRA TECHNOLOGY REFRESH
SA 96646 K ADD CPS DOOR LATCHES
SA 97187 K SSEE INC F SFF (LPD17CL)
SA 97990 K RTSO OWN FORCE MONITORING OFM
SA 98046 K FDR D-EVO SUITE FSX
SA 98418 K HF TERMINAL MOD UPGRADE PC
SA 98419 K BRSE DATA MANAGEMENT HW
EC 86200 SPAWAR PEOC4I NMT AN/WSC-9 EC 005
EC 93335 SPAWAR KMI AN/GYK-72(V) TECH REFRESH
EC 95807 SPAWAR CBSP FLV/ULV UPS EC8
EC 96371 SPAWAR ATIP TERMINAL-DIRECT EC04
EC 96991 SPAWAR GBS GRS 6.1/NUS 3.1/HW PKI
EC 97091 SPAWAR MF-TDMA MODEM SUPPORT (NAVSSI)
EC 98765 SPAWAR NMT EC 09
EC 98814 NAVY CASH SYS NAVY CASH 2.0 HARDWARE, LI, CG
EC 99453 SPAWAR WAMS EC 01
MA 82565 LPD 17 HHD DOG EYEBOLT MOD
MA 87574 BOAT AND CARGO CRANE GENERAL I
MA 89386 MRG VACUUM TUBE MOD
MA 97950 LPD ECDIS HARDWARE UPGR (LI)
OA 87447 SWBD TO SUPT INSTALLATION OF M
OA 92738 SWBD NDDS NAVIGATION DISPLAY
RME 86679 SWAN SWAN REMOVAL
SWD 84291 CALIBRATION MCMS/METBENCH SOFTWARE INSTALL
SWD 86274 DISTANCE SUPPORT PEOEIS NIAPS 3.0.1 NIPR SRF LI
SWD 86898 SPAWAR PEOC4I NTCSS LINUX SWD 005
SWD 87799 MORIAH WIND MWS SW VER. 1.5 ON L CLASS
SWD 90012 SPAWAR SSEE INC F SWD REL CHARLIE
SWD 90017 SPAWAR SSEE INC F SWD REL DELTA
SWD 92735 SPMLPD17 NDDS SUSTAINMENT AND OBSOLESCE
SWD 92737 SPMLPD17 NAVIGATION CRITICAL DISTRIBUTI
SWD 92738 SPMLPD17 NDDS NAVIGATION DISPLAY UPGRAD
SWD 92875 SPAWAR NMT AN/WSC-9 SWD 12
SWD 92920 SPAWAR NTCSS FOOD SVCS MGMT (FSM) SW
SWD 92922 SPAWAR NTCSS ROM V242-03.01.02.XX
SWD 94694 IRRI 2.0.4 IN CANES IRRI 2.0.4/DRRS-N IN CANES
SWD 94887 SPAWAR ATIP SWD 005
SWD 95449 SPAWAR ADNS INC III FS3
SWD 95533 SPAWAR GCCSM V4.1.5.0
SWD 95724 SPAWAR CANES SW5
SWD 95854 SPAWAR AIS V1 CYBER SW UPG
SWD 97011 ECDIS-N/SCALABLE IBS R2 NAVY ECDIS SW VER 1.3 (AMPHIBS)
SWD 97475 SPMLPD17 ECS V5.6 SOFTWARE UPGRADE
SWD 97692 SPAWAR MFOM CRT V540-02.00.39.XX
SWD 98420 SPAWAR BRSE DATA MANAGEMENT SW
SWD 98545 MEDICAL SOFTWARE TMIP-M V4.2.X.X (NON-CARRIERS)
SWD 98836 NAVY CASH SYS NAVY CASH 2.0 SOFTWARE, LI
SWD 99341 NSIPS PEO-EIS NSIPS WEB AFLOAT V1.4.
SWD 99578 SPAWAR CAAS SOFTWARE UPDATE
Enclosure (1) | Page iv
SWD 99678 SPAWAR ATCS AN/KRC-6(V)1 SW
C. The Availability’s maintenance requirements are expected to include the following types of work:
Hull Structure Fuel Oil Service Tank/Auxiliary Fuel Oil Service Tank/JP-5 Tank Preservation and Structural repairs Hull Structure, Bulkheads, Deck, and Platform repairs/modifications Well Deck, Flight Deck, Vehicle Deck repairs/modifications Repair and replacement of watertight doors, hatches, and scuttles
Propulsion Plant Main Propulsion Diesel Engine repairs Main Seawater Cooling Pump overhauls Sea Water/ Central Fresh Water System repair Lube/Fuel Oil Purifiers, pumps, valves and distribution systems repairs Diesel Engine Uptake, Intake and Exhaust Piping/Ducting repairs
Electric Plant and Distribution Equipment Ship’s Service Diesel Generator (SSDG) Engines Fuel Injectors, Jacket Water System and
Aftercooler Maintenance, Air Inlet Shutoff Valve Replacement.
400Hz Solid State Frequency Converter (SSFC) Distribution Upgrade
Command and Surveillance Advanced Enclosed Mast System preservation SLQ-32 Platform preservation
Auxiliary Systems A/C plants compressor replacement Sea Water, Fresh Water, Potable Water and Gray Water system pumps, valves and system repairs VCHT pump and motor replacement Ballast/De-ballast system repairs Crane and Elevator repairs Replacement of insulation and lagging
Outfit and Furnishings Interior/ Exterior Decking Covering and Non Skid Replacement Well Deck Preservation Critical Coat Flight Deck/ Hangar Bay/ Well Deck Non Skid
Armament Cargo/Weapons Elevator repairs
Ship Assembly and Support Services Services would be directly related to availability, location, duration, and man-day determination. Man days can differ by region and whether the availability is performed in a public or private ship repair facility. Services would be predominately driven by availability duration with the exception of cleaning and pumping (tanks and bilges), crane, rigging, and temporary refrigeration services which are more ship-specific.
Key Maintenance Work Items (not all inclusive)
Enclosure (1) | Page 5