This document outlines the specifications for four [4] ambient air monitoring shelters to be used by a state or local agency. The shelters must meet specific requirements, including having a 100-amp breaker box or larger, being weatherproof and temperature controlled, having a level roof or roof platform, and being transportable. Three [3] of the shelters must have a floor space of 56 square feet, exterior dimensions of 8 feet by 8 feet, and an interior height of 7.5 feet, while one [1] shelter must have a floor space of 86 square feet, exterior dimensions of 12 feet by 8 feet, and an interior height of 7.5 feet. The shelters must have outward swinging, full-size doors that are lockable, and the roof must be able to withstand harsh winters with heavy snow.
The document does not provide any information about pricing terms, set asides, incumbents, funding requirements or sources, or contract term and renewal options.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications
Ambient Air Monitoring Shelters
Four [4] ambient air monitoring shelters to house and secure regulatory grade ambient air monitoring equipment in accordance with the Code of Federal Regulations. All shelters must have the following features:
Features:
· A 100-amp breaker box or larger.
· Prewired with lights, interior outlets, and two [2] exterior outlets.
· Be weatherproof and temperature controlled and maintain a stable temperature between 68°F and 86°F year-round, with minimally a R15 insulation rating.
· Have a level roof, or level roof platform on which air sampling equipment will permanently reside.
· Shelters with a level roof must have features that protect the roof from damage from being walked on and from the permanent installation of equipment that may weigh up to 100 Ibs.
· Shelters with a roof platform must be at least 5 ft x 7.5 ft for all four [4] shelters.
· Shelter roof must be made of materials that allow the user to drill holes (up to 2 inches) through to the interior for the installation of equipment. The roof materials must also allow for easy sealing around these holes to prevent water intrusion.
· The shelters roofs must be able to withstand harsh winters with heavy snow.
· Have safe and secure roof or roof platform access for routine staff access with removeable OSHA-type guard rails.
· Transportable.
· Outward swinging, full-size door that is lockable.
Three [3] shelters must meet the following specifications:
· Floor space: 56 square feet
· Exterior length: 8 feet
· Exterior width: 8 feet
· Exterior height with guard rails removed: less than 9 feet
· Interior height: 7.5 feet
One [1] shelter must meet the following specifications:
· Floor space: 86 square feet
· Exterior length: 12 feet
· Exterior width: 8 feet
· Exterior height with guard rails removed: less than 9 feet
· Interior height: 7.5 feet