EI_011435443.pdf
PDF 100 KB Posted
- Solicitation number
- FA8251-25-DED_Head_Tray
About this file
This document is an Engineering Data Requirements attachment for a Display, Data Entry-Data Entry Display Set with National Stock Number 5895-01-143-5443 and Part Number 16VE173003. The document outlines specific technical requirements for manufacturing the display set, with a focus on Item Unique Identifier (IUID) marking and enhanced bonding specifications. Key technical requirements include using human and machine-readable matrices for labeling, with specific guidelines for label content (CAGE code, Part Number, Serial Number) and minimum lettering/matrix size. The enhanced bonding process mandates replacing all 128 exterior bonds with new gold wire, which is specified as superior to the original aluminum wire due to better conductivity and increased robustness. The document was prepared by Jake Widdison at Hill Air Force Base, with a date of 08/06/25, and emphasizes that any material substitutions require prior approval from the cognizant engineering activity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| -1224_RQR_Section C.pdf | ||
| 011873272.RDL.pdf | ||
| F-16_DED_Head_Tray Sources Sought_25.pdf | ||
| 011811224.RDL.pdf | ||
| -3272_RQR_Section C.pdf | ||
| -5443_RQR_Section C.pdf | ||
| 011435443.RDL.pdf | ||
| EI 5895-01-181-1224WF.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REV: ENGINEERING DATA REQUIREMENTS
(ATTACHMENT “A”)
NOTE: MILITARY SPECIFICATIONS / STANDARDS WILL NOT BE FURNISHED IN THE BID SET.
1. THE FOLLOWING INSTRUCTIONS ARE FURNISHED FOR THE MANUFACTURE OF:
DISPLAY, DATA ENTRY-DATA ENTRY DISPLAY SET
2. PART NUMBER:
16VE173003
3. NATIONAL STOCK NUMBER:
5895-01-143-5443
PREPARED BY:
Jake Widdison
OFFICE SYMBOL:
DATE:
08/06/25
HILL AFB FORM 462 Page 1 of 1
4. THE FOLLOWING SPECIFICATIONS/STANDARDS, ETC., WILL BE USED IN LIEU OF THE DATA INDICATED. THE
SUPERSEDED DATA WILL NOT BE FURNISHED UNLESS SO INDICATED.
5. THE SOURCES/MATERIALS IF LISTED ON THE SPECIFICATION, STANDARDS AND DRAWINGS ARE THE ONLY SOURCES/MATERIALS FOR THOSE ITEMS. ANY SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL BY THE COGNIZANT
ENGINEERING ACTIVITY.
6. IUID (ITEM UNIQUE IDENTIFIER) REQUIREMENTS AND EXPECTATIONS WHICH THE CONTRACTOR MUST ENSURE ARE
COMPLIED WITH.
7. CONTRACTORS DRAWINGS SHALL BE CHANGED OR SUPPLEMENTED BY CONTRACTOR FOR IUID COMPLIANCE.
A. LABEL SHALL CONTAIN ALL DATA ON EXISTING LABEL, (IF EXISTING LABEL IS TO BE REPLACED), ONLY
DELETE EXISTING LABEL WITH GOVERNMENT ENGINEERING PERMISSION.
B. USE HRI (HUMAN READABLE) AND MACHINE READABLE MATRIX. (USAF NOT EQUIPED TO READ BARCODE).
C. IUID MATRIX NEEDS TO BE HIGHLY VISIBLE, IN A LOCATION EASILY ACCESSIBLE.
D. IUID MARKING MUST BE PERMANENT.
E. MIL-STD-130, ANSI/AIM BCII, ISO 15434, ISO 15415, AND ISO 15418
F. IUID MARKING SPECIFICATIONS.
1. MINIMUM 1/8 INCH LETTERING ON HUMAN READABLE TO INCLUDE:
A. CAGE (17V)
B. P/N (1P)
C. SERIAL NUMBER (IS)
2. MINIMUM 1/4 INCH SQUARE ON MACHINE READABLE 2D MATRIX -CONSTRUCT 2 - TO INCLUDE
A. CAGE (17V)
B. P/N (1P)
C. SERIAL NUMBER (IS)
8. ENHANCED BONDING WILL BE PREFORMED ON DISPLAY, DATA ENTRY-DATA ENTRY DISPLAY SET.
A. ENHANCED BONDING REQUIRES THAT THE ENTIRE 128 EXTERIOR BONDS BE REPLACED WITH NEW GOLD WIRE RATHER THAN ONLY SPOT REPAIR OF CURRENT FAILED ROW AND COLUMN BONDS AS IN THE
PREVIOUS REPAIR PRACTICE.
B. THE ORIGINAL BOND WIRE WAS ALUMINUM RATHER THAN GOLD. GOLD WIRE IS REQUIRED FOR THIS
APPLICATION FOR TWO REASONS.
1. GOLD IS A BETTER CONDUCTOR THAN ALUMINUM.
2. GOLD IS LESS BRITTLE THAN ALUMINUM AND IS A MORE ROBUST MATERIAL FOR THIS
APPLICATION.
File details come from the government source that posted it. Updated .