This document is an Asbestos Inspection Report for the National Fish Hatchery in Edenton, North Carolina, prepared by OBX Environmental Consultants under contract with the U.S. Fish and Wildlife Service.

The report identifies the presence of asbestos-containing materials (ACM) in Buildings 1, 2, and 4 of the hatchery facility, including textured ceiling materials, drywall, floor tiles, and exterior caulking. Sampling and analysis was performed to determine the location and quantity of ACM. The primary ACM concerns are friable materials in the exterior and crawlspace areas of Building 4, and textured ceiling materials in Building 1. The report provides recommendations for proper handling and abatement of the identified ACM prior to any renovations or demolition activities at the site.

This report appears to be related to the federal contract opportunity for Asbestos Abatement at the Edenton National Fish Hatchery, with a solicitation number of 140FC224Q0058, issued by the U.S. Department of the Interior Fish and Wildlife Service.

View the file

Other files

File Type Posted
Provisions_and_Clauses.doc DOC document
Wage_Determination_NC20240065.pdf PDF
Sol_140FC224Q0058.pdf PDF
SOW_Asbestos_Abatement.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Prepared For:

Asbestos Inspection Report

Buildings 1, 2, and 4

National Fish Hatchery, Edenton NC

April 2019

Prepared By:

This page left blank intentionally

ASBESTOS INSPECTION REPORT

National Fish Hatchery 1104 W Queen St, Edenton, NC 27932 Various Buildings

Prepared For:

Department of the Interior US Fish and Wildlife Service

April 2019

OBX Environmental Consultants

508 West Chowan Drive Kill Devil Hills, NC 22339

252-725-5896

ASBESTOS INSPECTION

NATIONAL FISH HATCHERY, EDENTON, NC TABLE OF CONTENTS

OBX ENV i April 2019

EXECUTIVE SUMMARY ...................................................................................II

1. ASBESTOS .......................................................................................... 1-1

1.1 BUILDING 1 .............................................................................................. 1-3

1.1.1 ACM Notes Bldg. 1: .................................................................... 1-4

1.2 BUILDING 2 .............................................................................................. 1-5

1.2.1 ACM Notes: ................................................................................ 1-7

1.3 BUILDING 4 .............................................................................................. 1-7

1.3.1 ACM Notes: ................................................................................ 1-9

1.4 CERTIFICATION ...................................................................................... 1-10

TABLES

TABLE PAGE

Table 1-1 Sample Summary, Building 1............................................................... 1-4 Table 1-2 Sample Summary, Building 2............................................................... 1-5 Table 1-3 Sample Summary, Building 4............................................................... 1-8

APPENDICES

A. Hazmat Inspection Sketches

B. Inspection Photo-Log

C. Laboratory Reports of Analysis

NATIONAL FISH HATCHERY, EDENTON, NC ASBESTOS INSPECTION

OBX ENV ii April 2019

EXECUTIVE SUMMARY

Outer Banks (OBX) Environmental Consultants has prepared this Asbestos

Inspection Report for the use of US Fish and Wildlife staff and engineers to provide information concerning asbestos building materials identified at the US Department of the Interior (USDoI), Fish and Wildlife Service (USFWS) National Fish Hatchery, Edenton NC that may be impacted by work associated with various buildings therein.

The project was conducted under contract between USFWS and OBX as project

#NC01. Work was authorized by Ms. Sonja Mumford, hatchery manager.

This site inspection and assessment was conducted by OBX staff and involved sampling of suspect asbestos containing materials (ACM) at three buildings only. A full National Emission Standard for Hazardous Air Pollutants(NESHAPs), including testing of paint/coatings, and other known potentially hazardous materials (HAZMAT) including Resource Conservation and Recovery Act (RCRA) metals that may be impacted by renovations at the site was not requested nor conducted.

The primary concern for the building appears to be friable ACM identified on the exterior and crawlspace areas of Building 4 (1106 W. Queen) and textured ceiling material on the interior of Building 1 (1102 W. Queen). Other Category I and II non-friable materials are also present in all buildings. The precise means and methods to handle the identified hazardous materials are covered under state and federal laws, separate from this document.

Inspection at the facility was conducted 14 April 2019 which included identification, sample collection and analysis, evaluation of suspect ACM, and estimation of the quantities of ACM present.

Asbestos inspection information is provided in Section 1. Lead inspection information is not provided. Other potentially hazardous material (OPHM) issues are not provided. Site drawings indicating sample locations and information concerning the location of ACM are provided in Appendix A, a reference photo-log is included in

OBX ENV iii April 2019

Appendix B, and the laboratory reports of analysis for all samples collected are provided in Appendix C.

OBX ENV 1-1 April 2019

1. ASBESTOS

There is a well-known link between the inhalation of asbestos fibers and various diseases such as asbestosis, mesothelioma, lung and other cancers. As a result, the

Asbestos Hazard Emergency Response Act (AHERA, 40 CFR Part 763) was enacted. An AHERA inspection requires an accredited inspector to visually inspect and assess the condition of all known or assumed friable asbestos-containing building materials (ACM); to visually inspect non-friable ACM and touch it to determine friability; and to identify homogeneous areas of friable materials. The

National Emission Standards for Hazardous Air Pollutants (NESHAPs) require thorough inspections for asbestos in structures before renovation or demolition.

The intent of this inspection was to provide sufficient information to involved parties that may impact the demolition and renovations of area equipment and to prepare adequate abatement specifications for such. Bulk sampling of suspect ACM was performed. Samples were analyzed utilizing Polarized Light Microscopy (PLM) with dispersion staining (EPA method 600/M4/82/020). The accredited laboratory reports of analysis are provided in Appendix C.

The sample identification system of this report consists of a three-unit sample identification number. For example, 44-01-03 would indicate that the sample was collected from Area 44, homogenous area one, and was the third sample collected [of that homogenous material] during the inspection. These sample numbers match the chain-of-custody, lab reports of analysis, and sample identification numbers on the drawings (Appendix A). No historical sample data was provided or referenced for this project.

Sample result summaries are provided in table format. Note that NAD in the % asbestos column indicates that there was No Asbestos Detected in the sample.

Some sample results in this column may be displayed in this report with a slash between two numbers, (#/#). The first number represents the first material listed

OBX ENV 1-2 April 2019 under the material location/description and the second number represents the second material listed. Sampled materials that contain asbestos are highlighted in bold red and underlined, although none were identified.

The samples are also grouped into homogeneous material/area groups.

Homogeneous materials are suspect materials that are uniform by color, texture, construction/application date and general appearance. Photos are included in the reference photo-log (Appendix B) for assistance in later material identification.

Sample summary tables also distinguish whether materials are considered friable

(able to be crushed or pulverized by hand pressure) or non-friable (not able to be crushed or pulverized by hand pressure) for the purpose of determining the ACM category. The collected samples were at least l cubic centimeter and were placed in a sealed container at the time of collection. Appropriate precautions were taken to prevent exposure to those present in or around the facility during the collection of samples, including wet collection methods.

As previously mentioned, the asbestos NESHAP (40 CFR 61, subpart M) requires a thorough inspection for asbestos in structures before the renovation or demolition of those structures. Materials determined to be ACM (containing greater than 1% asbestos) must also be categorized for removal and demolition purposes. The various categories for ACM are shown in the following chart.

ACM Category (NESHAP)

Categories Typical Material Type Guidance for RACM

Friable ACM Pipe insulation fittings Able to crush with hand pressure

Cat I, Non-friable

Floor coverings, Roofing products, Gaskets

Non-friable materials that have become friable, or Non-friable material that is or will be damaged due to sanding, grinding, cutting, or abrading

Cat II, Non-friable

Cement siding (Transite), Significantly damaged tile

Non-friable material that has a high probability of becoming or has become friable by forces expected to act on the material in the course of renovation or demolition

OBX ENV 1-3 April 2019

Any ACM that is Friable, or Category I and II Non-friable that meets the qualifications to be considered a Regulated Asbestos-Containing Material (RACM), must be removed prior to demolition or disturbance that would break up, dislodge, or similarly destroy the material or preclude access to the material for subsequent removal.

The findings of the asbestos inspection are detailed in the following section, including recommendations for action.

Visual surveys were performed of accessible suspect ACM of three buildings at the site, designated as follows:

Building 1; 1102 W. Queen Street, Edenton NC

Building 2; 1104 W. Queen Street, Edenton NC

Building 4; 1106 W. Queen Street, Edenton NC

Construction dates were unknown, but estimated at pre-1970.

1.1 BUILDING 1

The asbestos survey of identified Five (5) unique homogenous suspect materials.

The homogenous materials identified include:

Textured ceiling material

Drywall material

Joint material

Tan floor tile

Exterior caulking

Bulk sampling was performed on the suspect ACM anticipated to be disturbed during renovations. Sixteen (16) samples were collected for asbestos analysis which included sixteen (16) individual layer analyses. A summary of sample results are provided in Table 1-1. ACM was identified.

OBX ENV 1-4 April 2019

Table 1-1 Sample Summary, Building 1

Sample # Description (level) Asbestos

Friable

1-01-01

1-01-02

1-01-03

1-01-04

1-01-05

Textured ceiling material, office

Textured ceiling material, office 2

Textured ceiling material

Textured ceiling material, kitchen

Textured ceiling material, living room

NAD

<1

YES

YES

N/A

N/A

YES

1-02-01

1-02-02

1-02-03

1-02-04

Drywall with joint material, closet, office 2

Drywall material, closet, wall

Drywall material, wall, kitchen

Drywall material, wall, living room

NAD/ 3

NAD

NAD

NAD

NO

N/A

N/A

N/A

1-03-01

1-03-02

1-03-03

Joint material, wall, office 2

Joint material, wall, closet

Joint material, wall, kitchen

NAD

N/A

NO

NO

1-04-01

1-04-02

Tan floor tile (under carpet and ¾ wood)

Tan floor tile (under carpet and ¾), living room

NO

NO

1-05-01

1-05-02

Exterior caulking, white, window residual

Exterior caulking, white, window residual

NAD

NAD

N/A

N/A

End Table 1-1

1.1.1 ACM Notes Bldg. 1:

HM01: Textured Ceiling Material. This ACM was identified throughout the interior of the structure with the exception of the restroom. Although presently in a non-friable state, disturbance will render this material friable and therefore it is a regulated ACM.

There is approximately 1184 square feet present.

HM03: Joint Material. This ACM, as a composite material with HM02, was identified throughout the interior of the structure on walls and ceiling. Although presently in a non-friable state, disturbance will render may material friable. Renovation will require controls however demolition may occur with the material intact. There is approximately 600 square feet present applied at joints.

HM04: Tan floor tile. This ACM is located under carpeting and plywood sheeting throughout, with the exception of the restroom area. The material is classified as a

Category I non-friable, but removal would require significant demolition and therefore it is a regulated material. There is an estimated 1184 square feet present.

OBX ENV 1-5 April 2019

1.2 BUILDING 2

The asbestos survey of identified seventeen (17) unique homogenous suspect materials. These materials were considered likely to be impacted by planned work.

The homogenous materials identified include:

Shingle roofing

Roof sealants

Drywall and joint material

Insulation

Carpet adhesive

Sink undercoating

2x2 ceiling tiles

Residual adhesives

Vinyl sheet flooring/ linoleum

Floor tile debris

Caulking material

Bulk sampling was performed on the suspect ACM anticipated to be disturbed during renovations. Forty-four (44) samples were collected for asbestos analysis which included forty-seven (47) individual layer analyses. A summary of sample results are provided in Table 1-2. Asbestos containing materials were identified.

Table 1-2 Sample Summary, Building 2

Sample # Description (level) Asbestos

Friable

2-01-01

2-01-02

Shingle roofing, brown

Shingle roofing, brown

NAD

NAD

N/A

N/A

2-02-01

2-02-02

Roof sealer, gray, chimney

Roof sealer, gray, chimney

NO

NO

2-03-01

2-03-02

Roof sealer, black, 1 ½” pipe

Roof sealer, black, 3” pipe

NAD

NAD

N/A

N/A

2-04-01

2-04-02

Drywall material, wall, east tank room

Drywall material, wall, west tank room

NAD

NAD

N/A

N/A

2-05-01

2-05-02

Joint material, wall, east tank room

Joint material, wall, west tank room

NAD

NAD

N/A

OBX ENV 1-6 April 2019

Table 1-2 Sample Summary, Building 2

Sample # Description (level) Asbestos

Friable

2-06-01

2-06-02

Insulation, white, attic

Insulation, white, attic

NAD

NAD

N/A

N/A

2-07-01

2-07-02

2-07-03

2-07-04

2-07-05

2-07-06

Carpet adhesive, yellow w/black, viewing area

Carpet adhesive, yellow w/black, viewing area

Carpet adhesive, yellow w/black, viewing area

Carpet adhesive, yellow w/black, storeroom

Carpet adhesive, yellow w/black, locker room

Carpet adhesive, yellow w/black

NAD

NAD

NAD

NAD

NAD

N/A

N/A

N/A

N/A

NO

N/A

2-08-01

2-08-02

2-08-03

2-08-04

Drywall material II, wall, viewing area

Drywall material II, wall, viewing area

Drywall material II, wall, addition

Drywall material, exterior restroom

NAD

NAD

NAD

NAD

N/A

N/A

N/A

N/A

2-09-01

2-09-02

2-09-03

2-09-04

Joint material II, wall, viewing area

Joint material II, wall, viewing area

Joint material II, wall, addition

Joint material, exterior restroom

NAD

NAD

NAD

NAD

N/A

N/A

N/A

N/A

2-10-01

2-10-02

Sink undercoating, gray, addition

Sink undercoating, gray, addition

NAD

NAD

N/A

N/A

2-11-01

2-11-02

2x2 ceiling tile, addition

2x2 ceiling tile, addition

NAD

NAD

N/A

N/A

2-12-01

2-12-02

2-12-03

2-12-04

Residual adhesive, brown, locker room

Residual adhesive, brown, hallway

Residual adhesive, brown, doorway

Residual adhesive, brown, office

NAD

NAD

NAD

NAD

N/A

N/A

N/A

N/A

2-13-01

2-13-02

Linoleum/ vinyl sheet flooring, office

Linoleum/ vinyl sheet flooring, office

NAD

NAD

N/A

N/A

2-14-01 Tan floor tile debris w/adhesive, baseboards 5 NO

2-15-01

2-15-02

Floor tile, brown w/adhesive, under [13]

Floor tile, brown w/adhesive, under [13]

2/ 3

2/ 3

NO

NO

2-16-01

2-16-02

2-16-03

Exterior caulking, white, residual window

Exterior caulking, white, residual window

Exterior caulking, white, residual door

NAD

NAD

<1

N/A

N/A

N/A

2-17-01

2-17-02

Exterior stucco, brown

Exterior stucco, brown

NAD

NAD

N/A

End Table 1-2

OBX ENV 1-7 April 2019

1.2.1 ACM Notes:

HM02: Roof sealant, gray. This ACM was identified at the chimney flashing on the roof. The material is non-friable and is anticipated to remain non-friable under most conditions, including demolition. There is around 2 square feet present.

HM07: Carpet Adhesive (residual black mastic). This ACM, likely from originally installed flooring, remains in the locker room area. The material is and will likely remain non-friable under most conditions, including demolition. There is an estimated

30 square feet of this ACM.

HM14: Floor tile debris (trapped at baseboard). This ACM, likely from originally installed flooring, remains in the southwest section of the building (see sketches).

Although the material is damaged, it is considered a Category I non-friable material, with exposure unlikely. There is an estimated 1-2 square feet remaining. However, other materials may be trapped in locations not accessible for viewing or identification.

HM15: Brown floor tile and mastic. This ACM is located under vinyl sheet flooring

[HM13] in a southwest room. The material is classified as a Category I non-friable and therefore it is a regulated material. There is an estimated 71 square feet present.

1.3 BUILDING 4

The asbestos survey of identified thirteen (13) unique homogenous suspect materials. These materials were considered likely to be impacted by planned work.

The homogenous materials identified include:

9” and other Tan floor tile and adhesive

Insulation

12” Grey floor tile and adhesive

Textured ceiling materials

Vapor barrier material

Exterior caulking

Cloth lagging material

Chimney cap material

OBX ENV 1-8 April 2019

Chimney liner material

Roofing sealant

Bulk sampling was performed on the suspect ACM anticipated to be disturbed during renovations. Twenty-nine (29) samples were collected for asbestos analysis which included thirty-seven (37) individual layer analyses. A summary of sample results are provided in Table 1-3. Asbestos containing materials were identified.

Table 1-3 Sample Summary, Building 4

Sample # Description (level) Asbestos

Friable

4-01-01

4-01-02

4-01-03

9” Tan floor tile and adhesive

9” Tan floor tile and adhesive

9” Tan floor tile and adhesive

3/ 3

3/ 2

4/ 2

NO

NO

NO

4-02-01 Insulation, yellow NAD N/A

4-03-01

4-03-02

Insulation, white

Insulation, white

NAD

NAD

N/A

N/A

4-04-01

4-04-02

12” Grey floor tile and adhesive (residual)

12” Grey floor tile and adhesive (residual)

2/ 3

2/ 3

NO

NO

4-05-01

4-05-02

4-05-03

Tan tile and adhesive

Tan tile and adhesive

Tan tile

3/ NAD

3/ NAD

NO

NO

NO

4-06-01

4-06-02

4-06-03

Textured ceiling material

Textured ceiling material

Textured ceiling material

NAD

NAD

NAD

N/A

N/A

N/A

4-07-01

4-07-02

Vapor barrier

Vapor barrier

NAD

NAD

N/A

N/A

4-08-01

4-08-02

Exterior caulking, window, black

Exterior caulking, window, black

NAD

NAD

N/A

N/A

4-09-01

4-09-02

Exterior caulking, white, residual

Exterior caulking, white, residual

NAD

NAD

N/A

N/A

4-10-01

4-10-02

Cloth lagging debris

Cloth lagging debris

YES

YES

4-11-01

4-11-02

Chimney cap, roof

Chimney cap, roof

NO

NO

4-12-01

4-12-02

Roof sealer, grey w/black, chimney

Roof sealant, grey w/black, old vent

NAD

NAD

N/A

N/A

4-13-01

4-13-02

Chimney liner

Chimney liner

YES

YES

End Table 1-3

OBX ENV 1-9 April 2019

1.3.1 ACM Notes:

HM01/ HM05: 9” and other Tan floor tile and mastic. This ACM is located in most areas of the first floor in significantly damaged condition. The material is classified as a Category I non-friable and therefore it is a regulated material. Renovation and or demolition requires control measures to be implemented for removal. There is an estimated 1040 square feet present as indicated on the sketches.

HM04: Grey tile and mastic (residual). This ACM is remnant patches of previous flooring in the northeast room only. The material is classified as a Category I non-friable and therefore it is a regulated material. There is an estimated 11 square feet present in damaged condition.

HM10: Cloth lagging (debris). This ACM is a roll of unutilized expansion joint/ lagging material used on duct systems. The material is a high percentage asbestos material and considered friable which can render fibers airborne if disturbed. . There is an estimated 1 square foot roll (approximately 25’ linear feet) with debris present at the entrance to the crawlspace. Other locations were not identified but may be present yet hidden from viewing.

HM13: Chimney liner material. This ACM is a panel material used as a decorative chimney cover. The material is a high percentage asbestos material. . There is an estimated 12 square feet present in the attic space with an additional 16 square foot exposed on the roof. Disturbance is likely to release asbestos fibers and is therefore a regulated ACM.

HM11: Chimney cap. The chimney top is protected with asbestos cement board panel, a Category II non-friable ACM. Although rigid in its current state, the material can break and may release fibers when broken. There is an estimated 10 square feet present.

OBX ENV 1-10 April 2019

1.4 CERTIFICATION

The AIHA and NVLAP Accredited laboratory selected to analyze the bulk samples for asbestos content by PLM and NIOSH method 7402 methods, equivalent to the

"Interim Method for the Determination of Asbestos in Bulk Insulation Samples”

(Appendix A to Subpart F in 40 CFR Part 763) was:

SANAIR TECHNOLOGIES LABORATORY, INC.

1551 OAKBRIDGE DR, SUITE B

POWHATAN, VA 23139

(804) 897-1177

The inspector who physically surveyed for ACM at the facility and who has received

EPA-approved training as an asbestos inspector and management planner is:

EARL E. ROSS

OBX ENV

NC# 12559

SIGNATURE OF INSPECTOR:

The inspector/ management planner who provided recommendations for ACM at the facility and who has received EPA-approved training as an asbestos inspector and management planner is:

DAVID DOBSON

OBX ENV

NC#20836

SIGNATURE OF MANAGEMENT PLANNER:

The above-signed inspectors certify information contained within this asbestos inspection report is true and correct concerning site conditions at the time of survey only. Every reasonable attempt was made to identify all ACM. However, locations not accessible such as wall interiors may contain materials not yet identified.

ASBESTOS INSPECTION APPENDIX A

NATIONAL FISH HATCHERY, EDENTON, NC ASBESTOS SKETCHES

OBX ENV April 2019

APPENDIX A

HAZMAT Inspection Sketches

ASBESTOS INSPECTION APPENDIX A

NATIONAL FISH HATCHERY, EDENTON, NC ASBESTOS SKETCHES

OBX ENV April 2019

工

事

喜

下

意

害

意

へ

葺

葉

音

幸 二 書 写 責 無

し 芝 憲 つ 亨 手 蔓 一

へ

嘗

停

月

購

用

兵

信

轟

き

ふ

う

ノ

プ

二

軍

い

う

姐 義 朝 智 乏

葦

当

Z

嵩 肩 章 持 運

曇 ご 意 志 鎧

嵩 忠 へ 奮 三 三 i

I l

旭 諦 牟 l 封 o

烏

農

蜜

ぐ

く

妄

言

裏

年

を

き

だ

き f l

呈

賞

賀

寅

年

き

し

と

で

素

き

し

と

重

き

き

電

卓

ノ

喜

タ

ブ

鳳同 国早 、Å ∪ 馬

宙

占 g

老

母

基

し

ス

定

ま

さ

し

急

き

烹

ざ

ら

要

録

し

害

こ i

シ

ソ

き

き i

巧

さ

ト

重

富

蜜

で

で

き

ヅ

毒

害 o

蔦

亀

I

華

と

イ

薫

で

ー

子

圭 t

さ

雪

青

く

蔦

書

き t

こ

基

い

た

ま

ご

賞

与 e

書

き

う

轡

さ

烏

軍

書

く

豊

電

ぐ

う

亡 宗 吾 田 口

J 霊 芝 昏 霊 怠

ト S 番 田 令 雲 量 一 汗 出 川 津 川 つ 白 川

馬

忠

照 β l

寄

口

裏

後

お

空 電 折 合 卜 乏

三 三¥¥∴

"ヽ 了 ���¥、, ¥‾ ¥¥、、¥、、、 ���簡 避

、¥¥¥¥、二

画∴㊥ ����∴∴ 1¥ �ミ⑧ ¥∴ �主 しつ こくJ 藍子 三三 三忌

龍 ¥ヾ¥ゝ¥ 紺

と くさ・ く/「. ○○“○○ � ¥ ∴十∴∴∴ ∴¥∴ ��¥∴ ¥、 ¥¥¥、怠 ��¥ ¥¥ �言金 一---一"i-

ゝや、¥¥¥、へ、、ヾ、、 ¥¥、、立¥¥¥、¥÷黒、 ¥

∴¥ 、でも¥今、、、 ¥ ��¥∴¥¥、¥¥?、、¥、 ¥ ���○○ _一〇

、、 ¥、、卜、 ¥¥¥ �� ¥ ヽ 、¥ ¥、 ���。髄: 討 手上 皇くく ¥¥ ��¥:

葵臆漢書臆題 ��“¥

惇¥¥¥もへ¥¥七 三ここ

、¥∴¥、、、二二‾着 旧へ千一、、---一一1--ノ

¥¥¥ �粍¥¥、言 千丁¥、二三十日

薄組∵、¥ ¥臆1 ��しi∴∴= 主 ●●“〇〇〇〇〇 〇l �¥¥¥、、¥、、¥’ �� 告 ∴

置 きl �¥¥了へ ¥二 、/ ∪ ¥¥ ∴;∴ �¥¥¥¥¥∴ヽ¥-÷--一一ぐ∴・ ¥¥¥へ¥“¥ 、¥¥ ¥、ヾ¥¥¥¥¥∴¥(、¥

ヽ勘 ���羊 へ¥¥¥言 〈 ・、¥こく ¥つ 、¥、、∴、、三 、、へ、 ¥、ヾ、¥

三言 ■〇〇〇.“i一一 ���器回書題■ ��、、 轟

¥ ¥〕ゝへ、 聾

うさ ���二二二: 骨 �¥、¥¥∴、¥ ¥¥¥、、 ¥¥音 ヽ しこ」 「二「 一一ノ’ �ノ ¥.」¥

し生 �¥→言、J 〔二二二王」」 小

I 純 漁 礁 厳 酷 部

曇 在 へ 芝 牟 ヒ 〆 高 魚

島 憲 遠 喜 連 一

ーー ーー ーー l・

心 耳 調 印 国 蟄

山 霊 討 喜 恵 も

し 叫 君 言 習 い

専一へ一軒札-

卿叫、細、▲吋調あ、竺㌢‾エーへつやml和、人‾‾亀と§

も 之 一 之 軍 孟 盆 山

罵 言 等 這 宣 一

圃 圏 圏

山 一

ざ

る

雷

撃

警

手

房

事

ま

と

え

さ

き

弓

菟

賓

京

き

享

と

葦 c

き

青

さ

き

ち

亭

ミ

ミ

京

曽

響

貫

重

垂 i

ま

ぐ

〇

で

ら g

き

き

手

を

手

工

圭

子

き

き

三

三

〇

ゴ

ミ

至

呈

雪

な

き

負

号

き

与

へ

I

一

二 l

圭

生

き

く

く

一

徽

事

J

章 l

ま

う

う

ま

き

ま

ま

う

ご

ま

I

ゝ

二

回 j

患

う

一 i

し

し 直 霊 室 い 甘 苦

幸 二 薫 昏 霊 鳥

亡 旧 譜 漢 音 三 軍 雲 二 吐 議 剖 昌 も N

吐 暮 漫

昌

一

へ

さ

き

さ

さ l

言

毒

舌

良

さ

ぢ

轡

J i

青

竜

嵩

さ

き

ま

く

響

き

昌

さ

ら

く

ま

墨

書

清

さ

言

う j

う

ま

電

場

甘

さ

憲

さ

う

ー

ウ i

書

手

尋

つ

善

く

嘉

ヨ

さ

き

種

I

く

く j

弓

子

〇

番

事

案

く

ま

あ

う

つ

ま j

J l

種

雪

書

き i e

事

さ

J

ま i l

軍

椅

ゴ

ミ

〇

〇

〇

く

輸

轟

き

罵

り

ト

番

い

き

い

慶

べ

官

は

一

筆

屈 c

貰

富

ト

ー

ー

菩

巨

竜

入

寮

賀

墓

き

き

重

さ

罵

き

き

を

宣

言

善

言

き

き

雪

害

奪

巨

下

寿

き

つ

待

号

雪

善

さ

I

き

き

き

き

雪

亘 i

ヽ

青

く

き

手

書

で

き

う

う

青

書

主

う

う

定

言

二

雪

し 蓋 重 用 l 十 善 言 善 い

ASBESTOS INSPECTION APPENDIX B

NATIONAL FISH HATCHERY, EDENTON, NC PHOTO LOG

OBX ENV April 2019

APPENDIX B

Inspection Photo-Log

ASBESTOS INSPECTION APPENDIX B

NATIONAL FISH HATCHERY, EDENTON, NC PHOTO LOG

PHOTO-LOG

Asbestos Inspection Report, Buildings 1, 2, and 4

National Fish Hatchery, W. Queen Street, Edenton, NC

Bldg. 1 ACM: Tan floor tile under carpet and plywood (typical).

Bldg. 2 ACM: Roof sealant, chimney

(typical).

Bldg. 1 ACM: Textured ceiling material

(typical).

Bldg. 1 ACM: Joint material.

Bldg. 2 ACM: Black residual mastic under carpet.

Bldg. 2 ACM: Remnant floor tile debris at baseboard.

PHOTO-LOG

Asbestos Inspection Report, Buildings 1, 2, and 4

National Fish Hatchery, W. Queen Street, Edenton, NC

Bldg. 4 ACM: 12” Gray floor tile and adhesive (typical).

Bldg. 4 ACM: Tan floor tile under other

(typical).

Bldg. 2 ACM: Brown floor tile and mastic

(typical).

Bldg. 4 ACM: 9” Tan floor tile and mastic

(typical).

Bldg. 4 ACM: Friable ACM lagging material debris.

Bldg. 4 ACM: Chimney cap with friable cover/ liner material (typical).

ASBESTOS INSPECTION APPENDIX C

NATIONAL FISH HATCHERY, EDENTON, NC LABORATORY REPORTS OF ANALYSIS

OBX ENV April 2019

APPENDIX C

Laboratory Reports of Analysis

ASBESTOS INSPECTION APPENDIX C

NATIONAL FISH HATCHERY, EDENTON, NC LABORATORY REPORTS OF ANALYSIS

Analyst: Moore, Brandi

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1-01-01 / 19017999-001 Textured Ceiling Matl-Popcorn Office

White Non-Fibrous

Homogeneous

3% Other 93% Other 4% Chrysotile

1-01-02 / 19017999-002 Textured Ceiling Matl-Popcorn Office # 2

White Non-Fibrous

Homogeneous

92% Other 8% Chrysotile

1-02-01 / 19017999-003 Drywall Matl, Closet, Office # 2, Joint Compound

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

1-03-01 / 19017999-004 Joint Matl, Wall, Office # 2, Paint

White Non-Fibrous

Heterogeneous

100% Other None Detected

1-04-01 / 19017999-005 FT Under Carpet & 3/4 Floor

Tan Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

1-02-02 / 19017999-006 Drywall Matl. Closet, Wall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

1-03-02 / 19017999-007 Joint Matl, Wall, Closet

White Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

1-01-03 / 19017999-008 Textured Ceiling Matl

White Non-Fibrous

Homogeneous

100% Other None Detected

1-02-03 / 19017999-009 Drywall Matl, Wall, Kitchen

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

1-03-03 / 19017999-010 Joint Matl, Wall, Kitchen

White Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1Project Number:

P.O. Number:

Project Name: CY 19 Phase 3

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 9:51:29 AM

19017999 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

252-261-5891 (H)Phone:

Analyst: Moore, Brandi

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1-01-04 / 19017999-011 Textured Ceiling Matl, Kitchen

White Non-Fibrous

Heterogeneous

100% Other < 1% Chrysotile

1-04-02 / 19017999-012 FT Under Carpet & 3/4 Floor, Living Room

Tan Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

1-01-05 / 19017999-013 Textured Ceiling Matl, Living Room

White Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

1-02-04 / 19017999-014 Drywall Matl., Wall, Living Room

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

1-05-01 / 19017999-015 Ext Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

1-05-02 / 19017999-016 Ext Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

1Project Number:

P.O. Number:

Project Name: CY 19 Phase 3

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 9:51:29 AM

19017999 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Analyst: Childress, Susan

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

2-01-01 / 19017994-001 Shingle Roofing

Brown Non-Fibrous

Heterogeneous

10% Glass 90% Other None Detected

2-01-02 / 19017994-002 Shingle Roofing

Brown Non-Fibrous

Heterogeneous

10% Glass 90% Other None Detected

2-02-01 / 19017994-003 Roof Sealer, Chimney

Grey Non-Fibrous

Homogeneous

94% Other 6% Chrysotile

2-02-02 / 19017994-004 Roof Sealer, Chimney

Grey Non-Fibrous

Homogeneous

94% Other 6% Chrysotile

2-03-01 / 19017994-005 Roof Sealer, 1 1/2" Pipe

Black Non-Fibrous

Homogeneous

10% Cellulose 90% Other None Detected

2-03-02 / 19017994-006 Roof Sealer, 3" Pipe

Black Non-Fibrous

Homogeneous

15% Cellulose 85% Other None Detected

2-04-01 / 19017994-007 Dywall Matl, Wall, Tankroom, East

Off-White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

2-05-01 / 19017994-008 Joint Matl, Wall, Tank Room, East

White Non-Fibrous

Homogeneous

100% Other None Detected

2-06-01 / 19017994-009 Insulation, Attic

White Fibrous

Homogeneous

98% Min. Wool 2% Other None Detected

2-06-02 / 19017994-010 Insulation, Attic

White Fibrous

Homogeneous

98% Min. Wool 2% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

2Project Number:

P.O. Number:

Project Name: CY 19 Phase 2

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 12:42:31 PM

19017994 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

2-07-01 / 19017994-011 Carpet Adh, Viewing Area

Various Non-Fibrous

Heterogeneous

100% Other None Detected

2-08-01 / 19017994-012 Drywall Matl, Wall, Viewing Area, Type 2

Off-White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

2-09-01 / 19017994-013 Joint Matl, Wall, Viewing Area, Type 2

White Non-Fibrous

Homogeneous

100% Other None Detected

2-07-02 / 19017994-014 Carpet Adh, Viewing Area

Various Non-Fibrous

Heterogeneous

2% Cellulose 98% Other None Detected

2-09-02 / 19017994-015 Joint Matl, Wall, Viewing Area, Type 2

White Non-Fibrous

Homogeneous

100% Other None Detected

2-08-02 / 19017994-016 Drywall Matl, Wall, Viewing Area, Type 2

Off-White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

2-07-03 / 19017994-017 Carpet Adh, Viewing Area

Various Non-Fibrous

Heterogeneous

< 1% Synthetic 100% Other None Detected

2-10-01 / 19017994-018 Sink Under Coating, Addition

Grey Non-Fibrous

Homogeneous

10% Cellulose 90% Other None Detected

2-10-02 / 19017994-019 Sink Under Coating, Addition

Grey Non-Fibrous

Homogeneous

10% Cellulose 90% Other None Detected

2-11-01 / 19017994-020 2' Ceiling Tile, Addition

White Fibrous

Homogeneous

55% Cellulose 25% Glass

20% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

2Project Number:

P.O. Number:

Project Name: CY 19 Phase 2

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 12:42:31 PM

19017994 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

2-11-02 / 19017994-021 2' Ceiling Tile, Addition

White Fibrous

Homogeneous

55% Cellulose 25% Glass

20% Other None Detected

2-08-03 / 19017994-022 Drywall Matl, Wall, Addition, Type

White Non-Fibrous

Homogeneous

3% Cellulose 97% Other None Detected

2-09-03 / 19017994-023 Joint Matl, Wall, Addition, Type 2

White Non-Fibrous

Homogeneous

100% Other None Detected

2-04-02 / 19017994-024 Drywall Matl, Wall, Tank Room, West

White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

2-05-02 / 19017994-025 Joint Matl, Wall, Tank Room, West

White Non-Fibrous

Homogeneous

100% Other None Detected

2-07-04 / 19017994-026 Carpet Adh, Storeroom

Various Non-Fibrous

Heterogeneous

100% Other None Detected

2-12-01 / 19017994-027 Residual Adh, Locker Room

Brown Non-Fibrous

Homogeneous

100% Other None Detected

2-07-05 / 19017994-028 Carpet Adh, Locker Room

Various Non-Fibrous

Heterogeneous

97% Other 3% Chrysotile

2-12-02 / 19017994-029 Residual Adh, Hallway

Brown Non-Fibrous

Homogeneous

100% Other None Detected

2-12-03 / 19017994-030 Residual Adh, Doorway

Brown Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

2Project Number:

P.O. Number:

Project Name: CY 19 Phase 2

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 12:42:31 PM

19017994 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

2-07-06 / 19017994-031 Carpet ADH

Various Non-Fibrous

Heterogeneous

6% Glass 94% Other None Detected

2-13-01 / 19017994-032 Linoleum, Newer, Office

Yellow Non-Fibrous

Homogeneous

10% Glass 90% Other None Detected

2-13-02 / 19017994-033 Linoleum, Newer, Office

Yellow Non-Fibrous

Homogeneous

10% Glass 90% Other None Detected

2-14-01 / 19017994-034 FT Debris, W/ Adh, Under Baseboard, Floor Tile

Tan Non-Fibrous

Homogeneous

95% Other 5% Chrysotile

2-14-01 / 19017994-034 FT Debris, W/ Adh, Under Baseboard, Mastic

Black Non-Fibrous

Homogeneous

100% Other < 1% Chrysotile

2-15-01 / 19017994-035 FTW/ Adh, Under (13), Labroom, Floor Tile

Brown Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

2-15-01 / 19017994-035 FTW/ Adh, Under (13), Labroom, Mastic

Black Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

2-15-02 / 19017994-036 FTW/ Adh, Under (13), Labroom, Floor Tile

Brown Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

2-15-02 / 19017994-036 FTW/ Adh, Under (13), Labroom, Mastic

Black Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

2-12-04 / 19017994-037 Residual ADH, Office Door

Brown Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

2Project Number:

P.O. Number:

Project Name: CY 19 Phase 2

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 12:42:31 PM

19017994 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

2-16-01 / 19017994-038 EXT Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

2-16-02 / 19017994-039 EXT Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

2-17-01 / 19017994-040 EXT Stucco

Brown Non-Fibrous

Homogeneous

100% Other None Detected

2-17-02 / 19017994-041 EXT Stucco

Brown Non-Fibrous

Homogeneous

100% Other None Detected

2-08-04 / 19017994-042 Drywall Matl, Ext Restroom

Brown Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

2-09-04 / 19017994-043 Joint Matl, Ext Restroom

White Non-Fibrous

Homogeneous

100% Other None Detected

2-16-03 / 19017994-044 Ext Caulk, Door, Residual

White Non-Fibrous

Homogeneous

100% Other < 1% Chrysotile

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

2Project Number:

P.O. Number:

Project Name: CY 19 Phase 2

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 12:42:31 PM

19017994 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

4-01-01 / 19017989-001 9" FT W/ Adh, Laundry Room, Floor Tile

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-01-01 / 19017989-001 9" FT W/ Adh, Laundry Room, Adhesive

Black Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-02-01 / 19017989-002 Insulation, Crawlspace

Yellow Fibrous

Homogeneous

95% Glass 2% Cellulose

3% Other None Detected

4-03-01 / 19017989-003 Insulation, Attic

White Fibrous

Homogeneous

98% Min. Wool < 1% Cellulose

2% Other None Detected

4-03-02 / 19017989-004 Insulation, attic

White Fibrous

Homogeneous

98% Min. Wool < 1% Cellulose

2% Other None Detected

4-04-01 / 19017989-005 12" FT W/ Adh, Kitchen Residual, Floor Tile

Grey Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

4-04-01 / 19017989-005 12" FT W/ Adh, Kitchen Residual, Mastic

Black Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-04-02 / 19017989-006 12" FT W/ Adh, Kitchen Residual, Floor Tile

Grey Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

4-04-02 / 19017989-006 12" FT W/ Adh, Kitchen Residual, Mastic

Black Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-05-01 / 19017989-007 FT W/ ADH, Living Room, Under Carpet & 3/4 Floor, Floor Tile

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

4Project Number:

P.O. Number:

Project Name: CY 19 Phase I

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 11:09:34 AM

19017989 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

4-05-01 / 19017989-007 FT W/ ADH, Living Room, Under Carpet & 3/4 Floor, Adhesive

Yellow Non-Fibrous

Homogeneous

100% Other None Detected

4-05-02 / 19017989-008 FT W/ ADH, Living Room, Under Carpet & 3/4 Floor, Floor Tile

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-05-02 / 19017989-008 FT W/ ADH, Living Room, Under Carpet & 3/4 Floor, Adhesive

Yellow Non-Fibrous

Homogeneous

100% Other None Detected

4-06-01 / 19017989-009 Texture Ceiling Matl, Popcorn

White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

4-01-02 / 19017989-010 9" FT W/ ADH, Closet Hallway, Floor Tile

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-01-02 / 19017989-010 9" FT W/ ADH, Closet Hallway, Adhesive

Black Non-Fibrous

Homogeneous

98% Other 2% Chrysotile

4-05-03 / 19017989-011 FT W/ ADH, Bedroom, Under Carpet & 3/4 Floor, Floor Tile

Tan Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

4-05-03 / 19017989-011 FT W/ ADH, Bedroom, Under Carpet & 3/4 Floor, Adhesive

Insufficient Material

4-07-01 / 19017989-012 Vapor Barrier Bedroom

Black Fibrous

Homogeneous

50% Cellulose 50% Other None Detected

4-06-02 / 19017989-013 Textured Ceiling Matl, Popcorn, Bedroom

White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

4Project Number:

P.O. Number:

Project Name: CY 19 Phase I

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 11:09:34 AM

19017989 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

4-07-02 / 19017989-014 Vapor Barrier

Black Fibrous

Homogeneous

50% Cellulose 50% Other None Detected

4-01-03 / 19017989-015 9" FT W/ ADH, Bedroom, Under Carpet & 3/4 Floor, Floor Tile

Tan Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

4-01-03 / 19017989-015 9" FT W/ ADH, Bedroom, Under Carpet & 3/4 Floor, Adhesive

Black Non-Fibrous

Homogeneous

3% Cellulose 95% Other 2% Chrysotile

4-06-03 / 19017989-016 Textured Ceiling Mat'l, Popcorn Bedroom

White Non-Fibrous

Homogeneous

2% Cellulose 98% Other None Detected

4-08-01 / 19017989-017 EXT Caulk, Window

Black Non-Fibrous

Homogeneous

100% Other None Detected

4-09-01 / 19017989-018 EXT Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

4-09-02 / 19017989-019 EXT Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

4-10-01 / 19017989-020 Cloth Lagging, Debris, Crawlspace

White Fibrous

Homogeneous

15% Other 85% Chrysotile

4-10-02 / 19017989-021 Cloth Lagging, Debris, Crawlspace

White Fibrous

Homogeneous

15% Other 85% Chrysotile

4-08-02 / 19017989-022 EXT Caulk, Window

Black Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

4Project Number:

P.O. Number:

Project Name: CY 19 Phase I

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 11:09:34 AM

19017989 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

4-09-03 / 19017989-023 EXT Caulk, Window, Residual

White Non-Fibrous

Homogeneous

100% Other None Detected

4-11-01 / 19017989-024 Chimney Cap, Roof

Black Non-Fibrous

Homogeneous

85% Other 15% Chrysotile

4-11-02 / 19017989-025 Chimney Cap, Roof

Black Non-Fibrous

Homogeneous

85% Other 15% Chrysotile

4-12-01 / 19017989-026 Roof Sealer, Chimney

Various Non-Fibrous

Heterogeneous

10% Cellulose 90% Other None Detected

4-13-01 / 19017989-027 Chimney Liner, Roof

Beige Fibrous

Homogeneous

40% Other 60% Chrysotile

4-13-02 / 19017989-028 Chimney Liner, Roof

Beige Fibrous

Homogeneous

40% Other 60% Chrysotile

4-12-02 / 19017989-029 Roof Sealer, Old Vent

Black Non-Fibrous

Homogeneous

95% Other 5% Chrysotile

Analyst:

Analysis Date: 4/25/2019 Date: 4/25/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

4Project Number:

P.O. Number:

Project Name: CY 19 Phase I

4/14/2019Collected Date:

4/16/2019 9:00:00 AMReceived Date:

4/25/2019 11:09:34 AM

19017989 SanAir ID Number

FINAL REPORT

OBX Environmental Consultants LLCName:

Address: 508 W Chowan St

Kill Devil Hills, NC 27948

Title Page
TOC
Executive Summary
Asbestos Inspection
A Sketches
B Photo Log
C Lab Reports

File details come from the government source that posted it. Updated .