ECS ICD Version 2.1_signed.pdf
PDF 878 KB Posted
- Attached to
- 0516-08 - ECS Durbin Assemblies Federal contract opportunity
- Solicitation number
- N0017822RC614
About this file
This document combines a synopsis and solicitation for an Enhanced Collection System (ECS) permanent-alteration cabinet assembly. The Naval Surface Warfare Center Dahlgren Division intends to award a sole source contract to The Durbin Group LLC for one customized ECS Perm-Alt Cabinet Assembly, model number DGM24210. Interested parties may submit a capability statement, proposal, or quotation by July 12, 2022. Award is anticipated by August 8, 2022 and will be made based on lowest price technically acceptable. The order shall be firm fixed price for delivery FOB destination to Dahlgren, Virginia. Simplified acquisition procedures will be used for this non-set aside requirement. Historical data and published pricing should be submitted with proposals.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Detail Specs_MIL-DTL-901E.pdf | ||
| N0017822RC614 (SF 1449).pdf | ||
| Redacted J_A.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Reviewed By:
Zach Mohle/B61 ECS Project Lead zachary.mohle@navy.mil
Enhanced Collection System (ECS) Interconnect Diagram (ICD)
Version 2.1 17 November 2021
Cable Legend
J10
J6
J7 J8 J9
J1 J2 J3 J4 J5
Enhanced Collection System (ECS)
CSER 2
MCE No. 5
CSER 2
pin pin
8‐pin 1G multi‐mode fiber 8‐pin multi‐mode 50u fiber 8‐pin (10GB‐LR) single‐mode 9u fiber pin pin pin pin
J226
J224
J222
J220
J76
J77
Panel Box Radar Room 2
Power Power
Note:
1. ECS ICD for MMSP includes J1‐J9. Spares on MMSP are J13, J14, J15, J16.
2. There will be 2 additional spots for future development (J17 and J18).
3. ECSP & RRP are components of MMSP
4. MCE #5 is part of ALIS Network
110v 30 amps 110v 30 amps
J11 J12
Radar Receiver Processor (RRP) Radar Room 2
Side Lobe B (ECS B2/1,2) Upper Guard B (ECS AB/3,4) Lower Guard B (ECS AB/5,6)
Sum B (ECS B1/1,2) Alpha B (ECS B1/3,4) Beta B (ECS B2/5,6)
Side Lobe A (ECS A2/1,2) Upper Guard A (ECS AB/3,4) Lower Guard A (ECS AB/5,6)
Sum A (ECS A1/1,2) Alpha A (ECS A1/3,4) Beta A (ECS A2/5,6)
Gyro SAN Mount
Core Switch
SPAN
Electronic Command Signals Programmer (ECSP)
Radar Room 2 pin
J105 Time Critical A
Time Critical B
ECS ICD MMSP
This ECS ICD is applicable to DDG 51‐53, 57, 61, 65, 69, 79, 80, 83, 113‐120
Version 2.1 17 November 2021
J105 only has 4 fibers terminated (1, 2, 3, 4).
The other fibers are spares
Pinout Legend
1 (ODD=RX)
2 (EVEN=TX)
ALL CROSSOVER
J16J15J13 J14 J17 J18
FUTURE CONENCTIONS
J10 – Filtered Core Switch VTwin
J11 – Front Serial Data Port SLQ‐32 V6 J12 – Front Serial Data Port SLQ‐32 V7
J6
J7 J8 J9
J1 J2 J3 J4 J5
Enhanced Collection System (ECS)
CSER 2
pin pin pin pin
J109
J110
J306
J307
Panel Box Radar Room 2
Power Power
Note:
1. ECSP & RDP 1 are components of MMSP‐R.
2. MCE #5 and #6 are part of ALIS Network
3. J17 & J18 are spares for future development
110v 30 amps
J11 J12
Radar Data Processor No.1 (RDP 1)
CSER 2
Side Lobe B (ECS‐B/Eth2) Upper Guard B (ECS‐B/Eth5) Lower Guard B (ECS‐B/Eth6)
Sum B (ECS‐B/Eth1) Alpha B (ECS‐B/Eth3) Beta B (ECS‐B/Eth4)
Side Lobe A (ECS‐A/Eth2) Upper Guard A (ECS‐A/Eth5) Lower Guard A (ECS‐A/Eth6)
Sum A (ECS‐A/Eth1) Alpha A (ECS‐A/Eth3) Beta A (ECS‐A/Eth4)
Electronic Command Signals Programmer (ECSP)
Radar Room 2 pin
J124 Time Critical A
Time Critical B pin
J116 pin
J117 pin
J310 pin
J311
1/2 MLG Near / RFP‐A
1/2 MLG Far / RFP‐B
1/2 SLG Near / RFP‐A
1/2 SLG Far / RFP‐B
Cable Legend
8‐pin multi‐mode fiber 8‐pin multi‐mode 50u fiber 8‐pin (10GB‐LR) single‐mode 9u fiber pin
J52
Gyro SAN Mount pin
J52
Core Switch
SPAN
Pinout Legend for MCE
1 (ODD=TX)
2 (EVEN=RX)
Straight Through
MCE #5
CSER 2
MCE #6
CSER 3
Pinout Legend
1 (ODD=RX)
2 (EVEN=TX)
ALL CROSSOVER
J14J13
8324038 ‐ 50uF MM Termini: M29504/14‐4141C
J16J15 J17 J18
ECS ICD MMSP‐R
This ECS ICD is applicable to DDG 82, 85, 87, 89, 90
Version 2.1 17 November 2021
FUTURE CONENCTIONS
J10 – Filtered Core Switch VTwin
J11 – Front Serial Data Port SLQ‐32 V6 J12 – Front Serial Data Port SLQ‐32 V7
M85045/17‐02P Termini: M29504/14‐4141C
J6
J7 J8 J9
J1 J2 J3 J4 J5
Enhanced Collection System (ECS)
CSER 2
pin pin pin pin
J226
J224
J222
J220
Panel Box Radar Room 2
Power Power
Note:
1. ECSP & RRP are components of MMSP 2.MCE #5 and #6 are part of ALIS Network
3. Applicable to DDG‐84 and DDG 86 (TI‐16)
110v 30 amps 110v 30 amps
J11 J12
Radar Receiver Processor (RRP) Radar Room 2
Side Lobe B (ECS‐B/Eth2) Upper Guard B (ECS‐B/Eth5) Lower Guard B (ECS‐B/Eth6)
Sum B (ECS‐B/Eth1) Alpha B (ECS‐B/Eth3) Beta B (ECS‐B/Eth4)
Side Lobe A (ECS‐A/Eth2) Upper Guard A (ECS‐A/Eth5) Lower Guard A (ECS‐A/Eth6)
Sum A (ECS‐A/Eth1) Alpha A (ECS‐A/Eth3) Beta A (ECS‐A/Eth4)
Electronic Command Signals Programmer (ECSP)
Radar Room 2 pin
J105 Time Critical A
Time Critical B
ECS ICD MMSP
This ECS ICD applies to DDG‐84 and DDG 86 (TI‐16)
Version 2.1 17 November 2021
J105 only has 4 fibers terminated (1, 2, 3, 4).
The other fibers are spares
Pinout Legend
1 (ODD=RX)
2 (EVEN=TX)
ALL CROSSOVER
8324038 ‐ 50uF MM Termini: M29504/14‐4141C
MCE #5
CSER 2
pin
J52Gyro SAN Mount pin
J52 Core Switch
SPAN
MCE #6
CSER 3
Pinout Legend
1 (ODD=TX)
2 (EVEN=RX)
Straight Through
J16J15J13 J14 J17 J18
Cable Legend
8‐pin 1G multi‐mode fiber 8‐pin multi‐mode 50u fiber 8‐pin (10GB‐LR) single‐mode 9u fiber
| Signature Page� |
| MMSP V2.1� |
| MMSP-R V2.1� |
| DDG84 & 86 V2.1� |
| Connector Legend MMSP� |
| Connector Legend MMSP-R� |
| 2021-11-19T12:16:29-0500 | |
| MOHLE.ZACHARY.S.1404527386 |
File details come from the government source that posted it. Updated .