The specifications outline six categories of maintenance equipment with defined quantities and configurations. The primary acquisitions include: 23 CX300 Communication test sets supporting CM-300 VHF/UHF radio testing and certification; 18 RTP5006 Boonton USB Wide Band Power Sensors with Power Analyzer Software for DASR and FAA ASR-11 testing; 11 DATA Scout DS10G-FAAT units for IVSR and NVR communications testing (listed at approximately $7,000 commercially or $8,262.85 through DoD NSN 6625-01-679-9197); 15 Keysight HD304MSO oscilloscopes featuring 14-bit resolution, MegaZoom V ASIC technology, and hardware-based waveform analysis capabilities; 3 R&S®CMA180 Radio Test Sets with specified component configurations including spectrum analyzers, power supplies, transport cases, and 2-year repair and calibration coverage; and 20 TF300 OTDR fiber optic units with Viavi SmartOTDR software, launch cables, and 3-year extended warranty packages. All specified equipment is listed in TB 43-180 (January 2026 edition) and designed to replace obsolete or unsupported legacy test and measurement devices. Recommended builds include calibration certificates, warranty packages, software installations, and comprehensive accessory kits per FAA and DoD standards.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Maintenance Equipment Specifications
1. CX300 Communication test set. Qty 23
a. Supports CM-300 VHF and UHF TX/RX radio PMCS and Certification;
Antenna VHF and UHF PMCS and Certification; ILS PMCS and Certification;
DASR PMCS and Certification; and potential for IVSR PMCS and Certification.
b. Recommended build:
i. TF300 DOD ATG ILS, CX300 CM300_350 Test System with ILS.
Includes CX300, CX300-SCAA, CX300-SVNA, CX300-SSPAR, CX300- ASOL, CX300-SCLC, CX300-ACH, USAF - CM300/350 Kit.
ii. CX300-SILVER-5 CX300-SILVER-5;5 Yr Total HW Warranty + Calibration with Certificate-SILVER-5.
iii. CX300-C9001 CX300-C9001; CX300 Calibration Certificate with test data - ISO 9001.
c. Replaces: IFR 2947A (no longer supported), Aeroflex 3920B (no longer supported), Anritsu MS2034B (no longer supported), URM-213, and many other like TMDE items.
d. TB 43-180 listed = yes, both the CX300 (360 day vendor cal) and Open/Short/Load (ASOL) (Calibration Not Required (CNR)) are listed in January 2026 edition.
2. RTP5006 Boonton USB Wide Band Power Sensor and Boonton Power Analyzer Software. Qty 18
a. Supports: DASR PMCS and Certification, FAA ASR-11 DASR website has authorized procedures for using this new sensor.
b. Recommended build: RTP5006 sensor and Boonton Power Analyzer Software. Boonton Power Analyzer Software to be installed on DASR WX Laptop IAW FAA SRD-ASR11-046.
c. Replaces: Boonton 56318 sensors (prone to failure), Boonton 4500A/B Power meter, Gigatronics Sensor 80350A, Gigatronics 8652A power meter and many other like TMDE items.
d. TB 43-180 listed = yes, RTP5006 (360 day vendor cal) listed in January 2026 edition.
3. DATA Scout DS10G-FAAT. Qty11
a. Supports: IVSR and NVR PMCS and Certification
b. Recommended build: Tempo Communications Model DS10G-FAAT was developed for FAA communication PMCS and certification.
c. Replaces: USM-485 which is obsolete and no Army TMDE TEMOD replacement and many other like TMDE items.
d. TB 43-180 listed = yes, DS10G-FAAT (CNR) listed in January 2026 edition.
e. Cost - ~$7K each commercial or FAA uses NSN 6625-01-679-9197 DoD cost is $8262.85 if FAA sells to Army.
4. The Keysight HD304MSO Qty 15
a. 14-bit resolution and low noise:
i. Delivers 64x more vertical resolution than a standard 8-bit oscilloscope with an industry-leading noise floor of 50 µV rms.
b. MegaZoom V ASIC:
i. This is what powers the massive waveform rate and ensures you catch even the shortest of duration signals of interest.
1. This is critical to catching random issues in COMMS & other critical ATC systems under test.
c. Hardware-Base Features:
i. Waveform plotting
ii. Waveform zoom
iii. Real time zone trigger
iv. Mask testing
v. Bandwidth filters down to 5MHz
vi. Color grading
5. R&S®CMA180 Radio Test Set Qty 3
Nomenclature Model Part # QTY
R&S®CMA180 Basic Assembly PS184, 0.1 MHz to 3 GHz CMA-PS184 1209.9621.02 2
Mechanics for removable Processor CMA-S050C 1173.5000.04 2
Solid State Disk H052R (sel.) CMA-S052R 1173.5100.19 2
Power supply R&S®PSU300, AC, H054B, 110V to 230V,300W CMA-S054B 1173.5151.03 2
OCXO reference oscillator, high performance, H690M (HW opt.) CMA-B690M 1173.5851.14 2
Spectrum analyzer, tracking gen. (SL) CMA-K120 1173.6206.02 2
VoIP Support acc. to EUROCASE ED137 (SL) CMA-K610 1209.7058.02 2
R2CMA180, R&S®Repair Coverage, 2 Years R2CMA180 3596.0975S31 2
C2CMA180, R&S®Manufacturer Calibration Coverage, 2 Years C2CMA180 3596.0975S41 2
Transport case,w hith w heels, telescoping handle, black(acc.) CMA-Z020A 1209.5555.02 2
Display protection cover (acc.) CMA-Z030A 1209.9796.00
2 2
Handset (acc.) CMW-Z50 1208.7602.02 2
600 Ohm set, BNC, 1W (acc.) CMA-Z651A 1209.7170.02 2
6. TF300 OTDR (x2) to replace our non-function Fiber Optic TMDE Qty 20 Includes:
Viavi SMARTOTDR126AP1-SmartOTDR ENTERPRISE-100 Smart Mapper Software EULCADS Replaceable Connector ESCREWDRIVERSENKO Screw Driver SILVER-3 3 Year Total Extended Warranty Testforce LC to ST Launch Cable 20m Testforce LC to LC Launch Cable 20m Cable Pouch